18 seconds Worldwide over 1 in 4 2 – 3 surgical sets ... · 9 medtech 360 trauma market devices,...

2
DO MORE WITH LESS UNIVERSAL SMALL FRAGMENT SYSTEM In general, small bone trauma affects the Shoulder, Clavicle, Elbow, Tibia and Fibula anatomies. Surgical treatment of small bone trauma occurs every 18 seconds Worldwide and represents over 1 in 4 of all bone trauma cases. * Operating room preparation for these cases commonly requires 2 – 3 surgical sets or more. This consumes space on the back table and slows down hospital workflow, creating inefficiencies in trauma care that increases hospital costs and consumes valuable resources. 1,2 DO MORE One core system to support any 2.7mm or 3.5mm implant from our comprehensive portfolio of plating options Ergonomically redesigned instruments simplified for ease of use Streamlined anatomic implant trays couple with core system to support specific procedures Modular case and tray allows flexibility to build different system configurations. System configurable to support exclusively sterile packaged implants REPROCESSING SURGICAL EQUIPMENT LIFTING & TRANSPORTING TIME-DRAIN OF MAINTAINING MANY SETS Staff may spend up to 1 hour per shift searching for equipment 4 Added cost to train staff on many surgical sets 1 EVIDENCE INFOGRAPHIC: SMALL BONE TRAUMA SIMPLIFIED SYSTEM ENABLING YOU TO DO MORE WITH LESS alone can cost a hospital • Existing sets may weigh more than industry recommendations • Lifting many surgical sets may increase risk of injury 5 PER CASE OR MORE >$ 500 INEFFICIENCY CAN LEAD TO SIGNIFICANT HOSPITAL COSTS AND WASTE SOLUTION 1 2 3 O P E R A T I N G R O O M S T O R A G E S T E R I L I Z A T I O N HOSPITAL WORKFLOW CYCLE 1 3 2 WITH LESS Fewer instruments and trays means less overall inventory to manage throughout the workflow

Transcript of 18 seconds Worldwide over 1 in 4 2 – 3 surgical sets ... · 9 medtech 360 trauma market devices,...

Page 1: 18 seconds Worldwide over 1 in 4 2 – 3 surgical sets ... · 9 medtech 360 trauma market devices, 2018; “europe markets for orthopaedic trauma devices, idata Research, 2015; “trauma

DO MORE WITH LESS

U n i v e r s a l s m a l l F r a g m e n t s y s t e m

In general, small bone trauma affects the Shoulder, Clavicle, Elbow,

Tibia and Fibula anatomies.

Surgical treatment of small bone trauma occurs every 18 seconds Worldwide

and represents over 1 in 4 of all bone trauma cases.*

Operating room preparation for these cases commonly requires 2 – 3 surgical sets or more.‡ This consumes space on the back table and slows down hospital

workflow, creating inefficiencies in trauma care that increases hospital costs and

consumes valuable resources.1,2

Do More• One core system to support any 2.7mm or 3.5mm

implant from our comprehensive portfolio of plating options

• ergonomically redesigned instruments simplified for ease of use

• streamlined anatomic implant trays couple with core system to support specific procedures

• modular case and tray allows flexibility to build different system configurations. System configurable to support exclusively sterile packaged implants

reprocessing surgical equipment

lifting & transporting

time-drain of maintaining many sets

• Staff may spend up to 1 hour per shift searching for equipment 4

• added cost to train staff on many surgical sets1

e v i d e n c e i n f o g r a p h i c : S M A L L B O N E T R A U M A

Simplified SyStem enabling you to dO mOre with less

alone can cost a hospital • existing sets may weigh more than industry recommendations ∞

• lifting many surgical sets may increase risk of injury 5per case Or mOre†

>$500

ineFFiciency can lead tO signiFicant hOspital cOsts and waste

s O l U t i O n

1 2 3OPERATING ROOM

STORAGESTERILIZATION

HOSPITALWORKFLOW CYCLE

1 3

2

WITh LESS fewer instruments and trays means less overall inventory to manage throughout the workflow

Page 2: 18 seconds Worldwide over 1 in 4 2 – 3 surgical sets ... · 9 medtech 360 trauma market devices, 2018; “europe markets for orthopaedic trauma devices, idata Research, 2015; “trauma

synthes usa, llc1101 Synthes AvenueMonument, CO 80132

To order (USA): 800-523-0322To order (Canada): 844-243-4321

© DePuy Synthes 2019. All rights reserved. 110317-190326 DSUS 4/19

Manufactured by:

1 delatore p, bourque m, taylor J, ferko n. the value of SKu reduction and standardization initiatives within a hospital system. Value in Health - iSpoR 21st annual internaitonal meeting.2016. pHp206.2 Richardson, d et al., “using lean methodology to decrease Wasted Rn time in Seeking Supplies in emergency departments, “Journal of nursing administration. 44(11):606-611, november 2014.3 menzie a, Vanderkarr m, badin m, bhattacharyya S. impact of distal radius sterile kit on provider budget in the uSa. iSpoR 2018 23rd annual international meeting. a36.4 ford, S. “nurses waste ‘an hour a shift’ finding equipment,” nursing times. 105(5):1, 2009 february.5 Heavy instrument Sets Sheds pounds” oR manager. february 2008. accessed at http://www.ormanager.com/wp-content/uploads/pdfx/oRmVol24no2instrumentSetsShedpounds.pdf6 Chobin, n. “the Real Costs of Surgical instrument training in Sterile processing Revisited”, aoRn J. 2010 aug;92(2):185-937 adrianzen, d. 2014. implementing lean process improvement in the Sterile processing department at the academic medical Center. Worcester, ma: Worcester polytechnic institute.8 uSf Claims matrix_072318_marketing claims validation lab recorded results.pdf9 medtech 360 trauma market devices, 2018; “europe markets for orthopaedic trauma devices, idata Research, 2015; “trauma devices market analysis — asia pacific,“dRg, 2017.10 depuy Synthes internal Sales data 2018.11 depuy Synthes internal litearture Search 2018.12 depuy Synthes earthwards Sterilzation Reference Values 2018.

U n i v e r s a l s m a l l F r a g m e n t s ys t e m

Simplified SyStem enabling you to dO mOre with less

CoStSaVingS

effiCienCy

eaSe of uSe

SuStainable Solution

WoRld ofplatingoptionS

sOlUtiOnBeneFits

cUrrent sOlUtiOns

hospital cost savings †

UPTO

50%

Fewer trays in Operating rOOm

saved in reprocessing cost

per case

$280 $72K per

year

time saved

$

Less storageneeDeD†

sUrgeOns assessing the system believe it will improve consistency and repeatability of operating room support across all small bone trauma8

simplifiedinstrumentation COMPARED TO

ExISTINg SySTEMS

standardized core set

procedure Cost: Solution may limit choice of implant to only premium cost technology

Hospital Cost: $500 or more per procedure to reprocess trauma equipment †

multiple sets require additional effort to coordinate perioperatively

training on multiple systems required

older tray technology requires out- of-tray washing°

Surgical teams must be knowlegeable on multiple systems for all small bone procedures

Variability in set weight to transport equipment∞

56%in Water & energy annually†∞

reduction12first trauma platform to receive earthwards recognition for providing a more environmentally sustainable solution∞

the universal Small fragment System, part of the depuy Synthes plating solutions, is designed for performance and delivers an extensive portfolio. Surgeons continue to trust depuy Synthes to drive innovation for new solutions.

#1glOBal market leader

World-Class products9

30milliOnprocedures10

1200+§

clinical stUdies& published articles11

saFer transpOrt

CoRe Set WeigHt

10kg 22.2lbs

standard & pre-cOntOUred plates

comprehensiveimplant options

with choice of implant to manage costs.

learn more about the earthwards® program at Johnson & Johnson by visiting https://www.jnj.com/innovation

<

• Retrieving fewer sets may mean a faster set up of operating room for trauma

• staff proficient in core set may become faster using the same system across all small fragment procedures6,7

• in-tray washing may eliminate need to reassemble trays after washing°

* based on 2017 worldwide procedure volumes.∞ the universal Small fragment System is an earthwards® recognized product. Reductions are in comparison to the existing depuy Synthes systems and derived using reference sterilization values. earthwards® is the Johnson & Johnson approach for

developing innovative and more sustainable products. ‡ based on internal procedure volumes for 2018.† Calculation takes into account depuy Synthes systems commonly used for each small bone trauma procedure, employs a weighted average of 2.25 sets per procedure, cost to wash a tray is $47.723 and approximately 5 trays are washed per set

on average when accounting for any wire bins that are also holding instruments.° assumes following existing depuy Synthes ifu§ World of plating options metrics shown is representative of all depuy Synthes plating categories, including mini fragment, Small fragment, and large fragment