    Loss of signal (LOS) Check line

    Transmitter Signal (TF) Replace unit

    Transmitter degraded (TD) Replace unit when possible (laser degrade)

    Loss of frame (LOF) Check line (alignment problems due to l ine error)

    AIS Check connected equipment

    Excessive BER (EBER) Check line (excessive line BER)

    Degraded Signal (DS) Check line (line signal degrade)

    Loss of Pointer (LOP) Check line

    Payload Mismatch (PLM) Configuration error

    Far End Received Failure(FERF)

    Check farend equipment

    Server Signal Failure (SSF)Check all the TU path. Alarm indicates AIS signal received onthe TU

    Frequency offset (DRIFT) Check reference and connection between it and the equipment

    Loss of timing source (LOSS) Check reference and connection between it and the equipment

    Resource Isolation Check connection between NE and Craft Terminal

    Communication SubsystemIsolation (CSF) Check Communication configuration (LAPD)

    Unequipped (U)

    Referred to Signal LabelConfiguration error

    Unconfigured EquipmentPresent (UEP)

    Unit inserted but not declared

    Internal Communication Prob-lem

    Reset NE. If persists substitute EQUICO/SYNTH1N/SYNTH4 unitaccording to the NE type.

    URU Underlying Resource

    UnavailableInsert the board

    PM_AS PerformanceMonitoring Alarm Synthesis

    Check path / line section interested to the indication.

    CPECommunication protocol

    error

    Check MSP protocol (architecture type, switch fail)

    LOMF Loss Of MultiFrame Check payload structure

  • 7/22/2019 1660SM Alarms

    2/6

    Allrightsreserved.

    Passingonand

    copyingofthis

    document,useandcommunication

    ofitscontents

    notpermittedwithoutwrittenauthoriza

    tionfromA

    lcatel.

    ED

    1AA000140004(9007)A4ALICE04.1

    0

    29

    02

    SC.4:NE MAINTENANCE

    /3AL 81412 AA AA

    82

    82

    MAINTENANCE

    PROBABLE CAUSE

    NAME AND/OR ACRONYM

    OF DISPLAYED ALARM

    AUXP Check farend equipment

    Remote Node Transmission

    error (RNTE)Check farend equipment

    Table 7. Boards alarms

    NAME AND

    ACRONYM

    OF DISPLAYED

    ALARM

    BOARD

    ACRONYM MAINTENANCE

    Unit missing

    (RUM)

    A2S1

    A21E1

    A3E3A3T3

    A4ES1

    AFOX

    ETHATX

    ETHMB

    GETHAG

    HPROT

    Insert missing unit

    Unit Problem

    (RUP)

    L41

    L41N

    L42

    L42N

    M4E1

    M1E3

    M1T3

    P3E3/T3

    P4ES1N

    P4S1

    Replace unit

    Unit type mismatch

    (RUTM)

    P4S1N

    P21E1

    P21E1N

    P21E1NM4

    P63E1

    P63E1N

    P63E1NM4

    S41S41N

    SERVICE

    Insert right unit (unit inserted into a slot set with another type ofunit)

    Unit Problem

    (RUP)EQUICO Replace unit

  • 7/22/2019 1660SM Alarms

    3/6

    Allrightsreserved.

    Passingonand

    copyingofthis

    document,useandcommunication

    ofitscontents

    notpermittedwithoutwrittenauthoriza

    tionfromA

    lcatel.

    ED

    1AA000140004(9007)A4ALICE04.1

    0

    30

    02

    SC.4:NE MAINTENANCE

    /3AL 81412 AA AA

    82

    82

    MAINTENANCEBOARD

    ACRONYM

    NAME AND

    ACRONYM

    OF DISPLAYED

    ALARM

    Unit missing

    (RUM) Insert missing unit

    Unit Problem

    (RUP)Replace unit

    Unit type mismatch

    (RUTM) PR16

    Insert right unit (unit inserted into a slot set with another type ofunit)

    Power Problem

    (POP)Replace unit

    Pump failure

    (PF)Replace unit

    Enclosure Door Open

    (EDO)

    Check that the protection cover in front of the unit has been cor-

    rectly placed.

    Unit missing

    (RUM) Insert missing unit

    Unit Problem

    (RUP)Replace unit

    Unit type mismatch

    (RUTM)

    BST15

    BST17

    Insert right unit (unit inserted into a slot set with another type ofunit)

    Pump failure

    (PF)Replace unit

    Enclosure Door Open

    (EDO)

    Check that the protection cover in front of the unit has been cor-

    rectly placed.

    Unit missing

    (RUM) Insert missing unit

    Unit Problem

    (RUP)Replace unit

    Unit type mismatch

    (RUTM)

    GETHMB Insert right unit (unit inserted into a slot set with another type of

    unit)

    Internal

    communication

    problem

    (ICP)

    Internal dialogue problem in the unit. It indicates a temporary con-

    dition which will be restored. If the condition persists it is due to a

    unit hardware failure: in this case it will activate the RUP alarm

  • 7/22/2019 1660SM Alarms

    4/6

    Allrightsreserved.

    Passingonand

    copyingofthis

    document,useandcommunication

    ofitscontents

    notpermittedwithoutwrittenauthoriza

    tionfromA

    lcatel.

    ED

    1AA000140004(9007)A4ALICE04.1

    0

    31

    02

    SC.4:NE MAINTENANCE

    /3AL 81412 AA AA

    82

    82

    MAINTENANCEBOARD

    ACRONYM

    NAME AND

    ACRONYM

    OF DISPLAYED

    ALARM

    Unit missing

    (RUM)Insert missing unit

    Unit Problem

    (RUP)

    MATRIXMATRIXN

    PREAS1PReplace unit

    Unit type mismatch

    (RUTM)

    PREA1GBE

    PREA4ETH

    ATM8X8

    Insert right unit (unit inserted into a slot set with another type of

    unit)

    Version Mismatch ATM4X4

    SYNTH1Update software version by means of SW download

    Internal

    communication

    problem

    (ICP)

    SYNTH1N

    SYNTH4Internal dialogue problem in the unit. It indicates a temporary con-

    dition which will be restored. If the condition persists it is due to a

    unit hardware failure: in this case it will activate the RUP alarm

    Unit missing

    (RUM)S161

    S161NInsert missing unit

    Unit Problem

    (RUP)

    S161ND

    L161 Replace unit

    Unit type mismatch

    (RUTM)

    161

    L161ND

    L162

    Insert right unit (unit inserted into a slot set with another type of

    unit)

    High Laser

    Temperature

    (HLT)

    L162N

    L162ND

    I161ND

    Replace unit

    Cooling Fans Failure

    (CFF)Check the fan units and substitute the faulty one

    Unit missing

    (RUM)

    FAN

    Insert missing unit

  • 7/22/2019 1660SM Alarms

    5/6

    Allrightsreserved.

    Passingonand

    copyingofthis

    document,useandcommunication

    ofitscontents

    notpermittedwithoutwrittenauthoriza

    tionfromA

    lcatel.

    ED

    1AA000140004(9007)A4ALICE04.1

    0

    32

    02

    SC.4:NE MAINTENANCE

    /3AL 81412 AA AA

    82

    82

    MAINTENANCEBOARD

    ACRONYM

    NAME AND

    ACRONYM

    OF DISPLAYED

    ALARM

    Unit missing

    (RUM)Insert missing unit

    Unit Problem

    (RUP)Replace unit

    Unit type mismatch

    (RUTM)

    Insert right unit (unit inserted into a slot set with another type of

    unit)

    LAN problem

    (LAN)

    CONGIThis alarm type is present only on 1650SMC or 1660sm.

    Check LAN interconnection or substitute CONGI unit

    Battery Failure

    (BF)

    According to the CONGI slot check the station battery.

    (Battery A or Battery B)

    Fuse Failure

    (FF) Substitute the fuse on the CONGI unit.

    Unit missing

    (RUM)Insert missing unit

    Unit Problem

    (RUP)Replace unit

    Unit type mismatch

    (RUTM)SERGI

    Insert right unit (unit inserted into a slot set with another type of

    unit)

    Battery Failure

    (BF)Check the Station Battery connected to the unit

    Fuse Failure

    (FF)Substitute the fuse on the CONGI unit.

  • 7/22/2019 1660SM Alarms

    6/6

    Allrightsreserved.

    Passingonand

    copyingofthis

    document,useandcommunication

    ofitscontents

    notpermittedwithoutwrittenauthoriza

    tionfromA

    lcatel.

    ED

    1AA000140004(9007)A4ALICE04.1

    0

    33

    02

    SC.4:NE MAINTENANCE

    /3AL 81412 AA AA

    82

    82

    Table 8. Module alarm

    Unconfigured

    Equipment Present

    (UEP)

    ICMI

    IS1.1

    IL1.1

    IL1.2

    MM1IS4.1

    IL4.1

    IL4.2

    SMOPT

    1000BSX

    1000BLX

    OHI

    OLIN

    OHMM

    OLMM

    Unit inserted but not configured