1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60...
-
Upload
alessandra-voice -
Category
Documents
-
view
234 -
download
8
Transcript of 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60...
![Page 1: 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C.](https://reader037.fdocuments.in/reader037/viewer/2022102705/55177eb35503463e368b5113/html5/thumbnails/1.jpg)
1/66
Rated Speed (m/s)
Load (Kg)
630 680 800 1000 1150 1275 1350 1600 1800 2000
1.00 50m/16F
1.50/1.60 75m/24F
1.75 75m/24F
Duty Table
Max. group control: G8C
GeN2 Regen
![Page 2: 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C.](https://reader037.fdocuments.in/reader037/viewer/2022102705/55177eb35503463e368b5113/html5/thumbnails/2.jpg)
2/66
Shenling Governor Gen2 Machine (MOR)
Controller
NGSOK
AES/AMS
CSB
Regen Drive
Space saving, energy saving, environmental friendly and excellent ride quality
GeN2 Regen
![Page 3: 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C.](https://reader037.fdocuments.in/reader037/viewer/2022102705/55177eb35503463e368b5113/html5/thumbnails/3.jpg)
3/66
OTIS unique technology- Coated Steel Belt (CSB)
20% less in weight while 2-3 times life time
Lubrication free
Size: 30×3 & 60x3
Steel cords: 12 & 24
Cord diameter 1.67mm
Breaking load: 32KN & 64KN
GeN2 Regen
Technology from helicopter (Siko-rsky)
![Page 4: 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C.](https://reader037.fdocuments.in/reader037/viewer/2022102705/55177eb35503463e368b5113/html5/thumbnails/4.jpg)
4/66
CSB makes GeN2 Regen machine much smaller
Diameter of sheave:100mm
Groove:3/5
Brake voltage:24V
Insulation class: F
Diameter of sheave:115mm
Groove:5
Brake voltage:24V
Insulation class: F
Roped Machine
Gen2 Machine
GeN2 Regen
![Page 5: 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C.](https://reader037.fdocuments.in/reader037/viewer/2022102705/55177eb35503463e368b5113/html5/thumbnails/5.jpg)
5/66
CSB monitor (RBI)
– Resistance Based Inspection (RBI) for CSB
– Dynamic inspection of CSB status
– LED indication
– Elevator level at nearest floor when failure inspected
– REM interface
– A component, not a tool
GeN2 Regen CSB Monitor
![Page 6: 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C.](https://reader037.fdocuments.in/reader037/viewer/2022102705/55177eb35503463e368b5113/html5/thumbnails/6.jpg)
6/66
GeN2 Regen OTIS GECB Controller board
Motorola 32 bit CPU with 1M Flash memory.
Rear time failure clinic automatically
CAN BUS 2.0 communication
CE Comply
ESD to avoid jobsite damage
Up to100 floors and 4m/s
ESD: Electro-Static discharge
![Page 7: 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C.](https://reader037.fdocuments.in/reader037/viewer/2022102705/55177eb35503463e368b5113/html5/thumbnails/7.jpg)
7/66
GeN2 Regen ACD2 MRL Controller and Drive
320W x1300H x 160D
Controller
OTIS energy regenerative drive CAN-bus communication Mini E&I Panel
210W x 540H x 90D
E&I Panel Drive
![Page 8: 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C.](https://reader037.fdocuments.in/reader037/viewer/2022102705/55177eb35503463e368b5113/html5/thumbnails/8.jpg)
8/66
OTIS Gen2 Machine
Regenerative system
Energy saving
Up to
Regen
Principle
GeN2 Regen
OTIS Regenerative Drive
+
![Page 9: 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C.](https://reader037.fdocuments.in/reader037/viewer/2022102705/55177eb35503463e368b5113/html5/thumbnails/9.jpg)
9/66
NGSOK Door operator
For Gen2 Regen and also for all other passenger elevators
• PM motor, energy saving
• VVVF controller
• Motor drive directly, no gearbox
• Disc motor, space saving
• Easier for installation
• Max. moving mass: 200kg
• Motor IP: 44
GeN2 Regen
Center Opening 700 800 900 1000 1100 1200
Open Time(s) 2.2 2.3 2.5 2.9 3.3 3.7
Close Time(s) 2.4 2.5 2.7 3.1 3.5 3.9
Re-open Distance(mm)
Open/Close noise(dBA)
Re-open noise(dBA)
100
52 (Peak)
55 (Peak)
Key parameters:
– Side opening is availble OP=900~1300
– Standard opening height:2100/2000
![Page 10: 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C.](https://reader037.fdocuments.in/reader037/viewer/2022102705/55177eb35503463e368b5113/html5/thumbnails/10.jpg)
10/66
GeN2 Regen Safety Components
E3 Qualified
Safety Gear
– Otis US design qualification
– Otis US MFG process control
– Otis US change control
– Reliable
– Durable
– Traceability
Component OTIS E3 Requirements EN81-1 Requirements
Safety Gear 25 freefall and runaway test 4 freefall test
Speed Governor 25 Continuous tripping 20 Continuous tripping
Buffer 100 strike test 6 strike test
Speed governor
Comparison
Oil buffer
![Page 11: 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C.](https://reader037.fdocuments.in/reader037/viewer/2022102705/55177eb35503463e368b5113/html5/thumbnails/11.jpg)
11/66
Excellent Performance Data
System performance Gen2 Regen(Belted, gearless)
Traditional lift(Roped geared)
X- Vibration A95 (mg) ≤ 9 ≤ 11
Y- Vibration A95 (mg) ≤ 9 ≤ 11
Z- Vibration A95 (mg) ≤ 11 ≤ 14
Speed Tolerance (%)(@+10%VRate, +1%fRate, Tmax 40 )℃ +3 +5
Maximum Acceleration( m/s2)(@ start and stop)
1.2 1.2
Maximum Jerk ( m/s3)(@ running)
1.0 1.0
Noise (dB)(@ Machine room)
≤ 72 ≤ 75
Noise (dB)(@ In car, w/o fan, running )
≤ 53 ≤ 53
Level accuracy (mm)(@+7%VRate, +1%fRate, Tmax 40 )℃
Typical: ±3 Max. : ±5
±5
GeN2 Regen