15kV - 38kV Recloser Polymer Insulated Type · The Joongwon Recloser is designed to meet increasing...
Transcript of 15kV - 38kV Recloser Polymer Insulated Type · The Joongwon Recloser is designed to meet increasing...
15kV - 38kV RecloserPolymer Insulated Type
www.joongwon.co.kr
Type of Recloser : JWREC -6A
ISO9001 ISO14001
tdCopyrightⒸ 2015 JOONGWON Corporation All rights reserved
Rev. 2015/ 1 /REC
Features
- Proven design rated for 10,000 full load operations
- Hydrophobic Cyloaliphatic Epoxy (HCEP) insulation provides industry leading reliability
- Air insulation for an environmentally friendly design
- Minimal maintenance required for the high voltage unit
- Web Human Machine Interface (web HMI) software for field configuration
- Remote Communication : MODBUS, DNP3.0, DNP3.0 over TCP/IP, IEC 60870-5-101, IEC 60870-5-104 over TCP/IP
Introduction
The Joongwon Recloser is designed to meet increasing requirement of the electric utility industry,
providing a safe, maintenance free, long life, economical device to perform fault current interrupting
and reclosing on overhead distribution lines. The Joongwon Recloser is applicable to 12(max.15)kV, 24(max.27)kV,
36(max.38)kV power distribution systems and substation. It can be operated manually(if applicable) or
electrically via controller with FTU and should be mounted to the pole and substation mounting base.
Recloser Design
• Magnetic actuator : 10,000 full load operations
• Vacuum interrupters : Lasting quality with 10,000 full load operations
• Pole assembly
- UV protected for environmental durability
- Molded design reduces risk of tampering
• HCEP insulating material
- The Recloser insulating material is Hydrophobic Cycloaliphatic Epoxy(HCEP).
Hydrophobic means resistant to water. This capability is advantageous because it prevents
water from developing completely wetted, resistively conductive surfaces on outdoor insulation.
Front View Of Recloser
LIFTING LUG
CLOSING
HANDLE
BUSHING
TERMINAL
RECEPTACLE
GROUND
CONNECTORTRIP HANDLE
Rear View Of Recloser
tdCopyrightⒸ 2015 JOONGWON Corporation All rights reserved
12.5 / 16
15kV - 38kV Polymer Insulated Outdoor Vacuum Recloserfor Distribution Automation
Ratings and technical data
ITEM
POWER FREQUENCY WITHSTAND VOLTAGE
RATED SYSTEM VOLTAGE 12 (max. 15)
RATED CONTINUOUS CURRENT
RATED INTERRUPTING CURRENT 12.5 / 16
DRY (1 MIN.) 50 60
WET (10 SEC.)
LIGHTNING IMPULSE WITHSTAND VOLTAGE 150110
RATED FREQUENCY
PHASE SPACING 320
EXTERNAL CREEP DISTANCE, H2-GROUND
320
1 486 1 486
Note : According to the user’s demand, Joongwon can supply Recloser with different ratings not indicated above.
RATINGS
24 (max. 27) kV
630 A
kA
kV
45 50 kV
kV
50 / 60 Hz
mm
mm
EXTERNAL CREEP DISTANCE, H1-H2 1 344 mm
MIN. EXTERNAL STRIKE DISTANCE
MIN. INTERRUPTING TIME
MAX. CLOSING TIME
284 284 mm
sec
sec
INSULATING MATERIAL
AMBIENT TEMPERATURE
HUMIDITY
ALTITUDE
DEGREE OF PROTECTION
MECHANICAL ENDURANCE
RATED CONTROL VOLTAGE
WEIGHT (BODY)
WEIGHT (CONTROLLER)
RATED STANDARD OPERATION DUTY
10,000 times
AC 110 - 220 V / DC 24 V
120
40
O - 0.3s - CO - 1s - CO - 1s - CO - lockout
kg
kg
Epoxy
m
-25 to 70 °C
≤100
≤ 2,000
IP X 8
%
Ratings
36 (max. 38)
12.5 / 16
70
170
394
1 502
60
1 376
448
1 344
0.050
0.070
APPLIED STANDARD IEC 62271-111, ANSI C37.60 & KEPCO spec.
150 230
tdCopyrightⒸ 2015 JOONGWON Corporation All rights reserved
ENVIRONMENTAL
PROGRAMMABLE FROM 1 TO 4
1-600SEC IN 1SEC STEPS
AMBIENT TEMPERATURE RANGE
OUTDOOR (HUMIDITY)
INSULATION TEST VOLTAGE
DEGREE OF PROTECTION
IMPULSE VOLTAGE WITHSTAND
INTERFERENCE TEST WITHSTAND
RADIO FREQUENCY INTERFERENCE
GENERAL PROTECTION ( CT RATIO 1000 : 1 A)
PHASE TIME OVERCURRENT
PHASE INSTANTANEOUS OVER CURRENT
GROUND INSTANTANEOUS OVER CURRENT
GROUND TIME OVER CURRENT
SENSITIVE EARTH FAULT
PHASE AND GROUND TIME CURVE
RECLOSER
RECLOSER TIMES
RECLOSING ( DEAD ) TIMES
RESET (RECLAIM) TIME
METERING ( AT RATED VOLTAGE AND CURRENT )
CURRENT
VOLTAGE
WATT HOURS
VARS HOURS
DEMANDS
POWER FACTOR
FREQUENCY
RECORDING
WAVEFORM CAPTURE
SYSTEM EVENT
DIAGNOSTIC EVENT
LOAD PROFILE
COUNTER TRIP, FAULT, SYSTEM RESTART, PQM
±1%
±2.5%
±5%
±3%
±0.05%
±3%
±0.05Hz
LAST 32 EVENTS WITH 20 cycles & 128 SAMPLES
LAST 2048 EVENTS
LAST 512 EVENTS
LAST 1024 EVENTS, 42 DAYS / 60 Min. (5,10,15,20,30,60 Min INTERVAL)
1st RECLOSER : 0.3-600SEC IN 0.01SEC STEPS.
2nd RECLOSER : 1.0-600SEC IN 0.01SEC STEPS.
3rd RECLOSER : 1.0-600SEC IN 0.01SEC STEPS.
4th RECLOSER : 1.0-600SEC IN 0.01SEC STEPS.
IEEE C37.112, IEC 60225-3, USER PROGRAMMABLE CURVE 37
CT RATIO X (0.0025 ̴ 0.160), (2.5 ̴ 160A)
CT RATIO X (1.00 ̴ 20.00), (1000 ̴ 20000A)
CT RATIO X (0.0025 ̴ 0.80), (2.5 ̴ 800A)
CT RATIO X (1.00 ̴ 20.00), (1000 ̴ 20000A)
CT RATIO X (0.005 ̴ 1.60), (5 ̴ 1600A)
IEC 255-22-3 CLASS III, ANSI C37.90.2
SWC ANSI C37.90.1, IEC 61000-4-4
6 kV PEAK, 1.5/50µs, ANSI C62.45, IEC61000-4-5
2 kV 50/60Hz, ONE MINUTE
IP65.
100%
STORAGE -40°C TO +85°C, OPERATION -25°C TO +70°C
727-9 , Wonsi-dong, Danwon-gu, Ansan-si, Gyeonggi-do, Korea
Tel :82-31-492-686 〜3 4 / 82-31-492-6866(DIR.)Fax:82-31-492-2620 http//www.joongwon.co.krE-mail:[email protected]
JOONGWON CO. Ltd.
Recloser controlRATINGS
PHASE A,B,C
LAST 100 EVENTS
50 or 60 Hz
15kV - 38kV Polymer Insulated Outdoor Vacuum Recloser for Distribution Automation
RATED FREQUENCY
CONTROL VOLTAGE AC 110 - 220 V / DC 24 V
RECLOSER WEAR
PQM