    Model G4AQuick ResponseConcealedAutomatic Sprinkler

    Bulletin 154 Rev.F

    Approvals & Listings

    1. Underwriters Labortories, Inc. (UL)-Quick Response

    2. Underwriters Laboratories of Canada (ULC)-Quick Response

    3. Factory Mutual Research Corp. (FM)-Standard Response

    Light Hazard Occupanicies-No Limitations

    Ordinary Hazard OccupanciesGroups 1 & 2 Wet Systems Only

    4. NYC MEA 258-93-E - Quick Response

    U.S. Patent number 4,880,063.

    ApplicationThe Reliable Model G4A

    Concealer is the most versatilequick response concealed sprin-kler available. It provides the bestform of fire protection whileoffering an attractive appearanceand (13mm) of cover adjust-ment for ease of installation. Thesmall diameter cover plate as-sembly is easily attached andblendsinto theceiling,concealingthe most dependable fire protec-tion available, an automaticsprinkler system.

    The Model G4A Concealer is designed for use whereaesthetic appearance is important. Offices, hospitals, motelsand restaurants are but a few ofthe applicationswhere itcanbe

    used. It isavailableindifferentorifice sizesallowingthedesigneto optimize system performance, thereby achieving a verefficient installation.

    TheModel G4A Concealer is a UL Listed Quick ResponseConcealed sprinkler intended for usein accordancewith NFPA13. FM Approves this sprinkler as a standard responseconcealed sprinkler intended for use in accordance with FMLossPrevention Data Sheet 2-8N.

    Product DescriptionTheReliable Model G4AConcealer

    uses a proven quick re

    sponsefusible elementina standard style sprinkler framewith adrop-down deflector. This assembly is recessed into the ceilingand concealed by a flat cover plate assembly. The threadedengagement provides (13mm) of coveradjustment. Theflacover plate is attached to the skirt using either 135F (57C) o165F (74C) ordinary temperature classification solder.

    Whenthe ceilingtemperature rises,thesolder holding theflacover plate melts, the flat cover plate released thus exposingthe sprinkler inside to the rising ambient temperature.

    The subsequent fusing of the element opens the waterwayand causes the deflector to distribute the water. Any secureengagement between the cover plate and cup will assure thathe drop-down deflector is properly located below the ceiling

    The Reliable Automatic Sprinkler Co., Inc. , 103 Fairview Park Drive, Elmsford, New York 10523

    The Concealer

    UL Quick ResponseFM Standard ResponseConcealed Sprinkler With a (13mm) or 1 (38mm) Adjustment

    Features1. Cover plate attachment with 12 (13mm)

    assembly adjustment.2. Smooth aesthetic ceiling profile.3. Factory installed protective cap.4. Available in brass, chrome or black

    plated and white painted finishes.5. Ordinary temperature rating.6. Multiple orifices for design flexibility.

  • 8/3/2019 154 G4A Concealed - Quick Response

    2/2

    InstallationDo not install the G4A Concealer

    in ceilings which have

    positive pressure in the space above. Cuta25 8 inch (67mm)diameter hole is cut in the ceiling,the

    sprinkler is easily installed with the Model G4 Wrench. Thewrench has drive tangs which insert into the cup slots.When installinga sprinkler the wrench is first positioned intothe sprinkler/cup assembly until the wrench tangs engagethe drive slots in the top of the cup (there are two sets ofdrive slots in the cup). The sprinkler is then tightened intothepipefitting. Wheninsertingorremoving thewrench fromthesprinkler/cupassembly, care shouldbe takentopreventdamage to the sprinkler. DO NOT WRENCH ON ANYOTHER PART OF THE SPRINKLER/CUP ASSEMBLY.Install the cover plate by hand turning the cover in theclockwise direction until it is tight against the ceiling.

    A protective cap is provided to protect the drop-down sprinklerdeflector from damage which could occur during constructionbefore the cover plate is installed. The cap is factory installedinside the sprinkler cup. Remove cap to install sprinkler, thenre-install cap until the cover plate is installed.

    MaintenanceThe Model G4A Concealer

    should be inspected quarterlyand the sprinkler system maintained in accordance with NFPA25. Donotclean sprinklers withsoap and water, ammonia or any

    other cleaning fluids. Remove any sprinkler that has beenpainted (other than factory applied) or damaged in any way. Astock of spare sprinklers should be maintained to allow quickreplacement of damaged or operated sprinklers. Prior toinstallation, sprinklers should be maintained in the originalcartons and packaging to minimize the potential for damage tosprinklers thatwouldcause improperoperationor non-operation.

    Ordering Information1. Sprinkler Model2. Nominal Orifice3. Flat Cover Plate

    Assembly Finish4. Inlet Type

    Temperature Rating

    Classification SprinklerCoverPlate

    Max. AmbientTemp.

    Ordinary 165F/74C 135F/57C 100F/38C

    Intermediate 212F/100C 165F/74C 150F/66C

    Technical Data

    Sprinkler InletTotal

    AdjustmentNominal

    OrificeNominal K Factor

    Thread ApprovalsSprinkler

    Identifcation (SIN)US Metric

    Non Adjustable (13mm) (15mm) 5.6 80 NPT (R) 1,2,3,4 R5415

    Non Adjustable (13mm) 7 16 (11mm) 4.2 60 NPT (R) 1,2,4 R5413

    Non Adjustable (13mm) 3 8 (10mm) 2.8 40 NPT (R) 1,2,3,4 R5411

    Adjustable 1 (38mm) (15mm) 5.6 80 1 NPT Male or Female 1,2,4 R5418

    Adjustable 1

    (38mm)7

    16

    (11mm) 4.2 60 1

    NPT Male or Female 1,2,4 R5413Adjustable 1 (38mm) 3 8 (10mm) 2.8 40 1 NPT Male or Female 1,2,4 R5412

    Model G4 SprinklerWrench

    UL Listing CategorySprinklers, Automatic andOpenQuick Response Sprinkler

    UL Guide NumberVNIV

    Standard Finishes

    BronzeChromeWhite Paint

    Special ApplicationFinishes

    Bright BrassBlack PlatingBlack PaintOff WhiteSatin Chrome

    Cover Plate Finishes(1)

    (1)Other finishes and colors areavailable on special order.Consult factory for details.

    Fig.1 - NPT Non-Adjustable Inlet Fig. 2 - 1 NPT Male-Adjustable Inlet Fig. 3 - 1 NPT Female-Adjustable Inlet

    Theequipment presented in thisbulletin is to be installed in accordance withthe latestpublished Standards of theNational Fire Protection Association,Factory MutualResearch Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.Productsmanufactured and distributedby Reliable havebeen protectinglife and property for over80 years, andare installed andservicedby the mosthighly qualifiedand reputable sprinkler contractors located throughout the United States, Canada and foreign countries.