15. Calibration

download 15. Calibration

of 3

Transcript of 15. Calibration

  • 7/29/2019 15. Calibration

    1/3

    Copyright 2004, TWI Ltd

    World Centre for Materials Joining Technology

    TWICSWIP 3.1

    WIS 5WELDING INSPECTION

    CALIBRATION

  • 7/29/2019 15. Calibration

    2/3

    Copyright 2004, TWI Ltd

    World Centre for Materials Joining Technology

    Calibration/Validation

    BS 7570: 1992 Covers the calibration andvalidation of welding equipment.

    Grade 1 (general purpose equipment) all

    parameters should be +/- 10%.

    Grade 2 (Automatic or automated equipment)parameters should be +/- 2.5% for current

    and +/- 5% for all other parameters.

  • 7/29/2019 15. Calibration

    3/3

    Copyright 2004, TWI Ltd

    World Centre for Materials Joining Technology

    Calibration/Validation

    Calibration can only be done on equipment with

    meters or gauges as theses can be adjusted.

    Validation can be done on equipment with and*without meters or gauges.

    Oil fill transformers etc.

    All equipment can be Validated but not all equipment

    can be Calibrated.