15. Calibration
-
Upload
onur-altuntas -
Category
Documents
-
view
220 -
download
0
Transcript of 15. Calibration
-
7/29/2019 15. Calibration
1/3
Copyright 2004, TWI Ltd
World Centre for Materials Joining Technology
TWICSWIP 3.1
WIS 5WELDING INSPECTION
CALIBRATION
-
7/29/2019 15. Calibration
2/3
Copyright 2004, TWI Ltd
World Centre for Materials Joining Technology
Calibration/Validation
BS 7570: 1992 Covers the calibration andvalidation of welding equipment.
Grade 1 (general purpose equipment) all
parameters should be +/- 10%.
Grade 2 (Automatic or automated equipment)parameters should be +/- 2.5% for current
and +/- 5% for all other parameters.
-
7/29/2019 15. Calibration
3/3
Copyright 2004, TWI Ltd
World Centre for Materials Joining Technology
Calibration/Validation
Calibration can only be done on equipment with
meters or gauges as theses can be adjusted.
Validation can be done on equipment with and*without meters or gauges.
Oil fill transformers etc.
All equipment can be Validated but not all equipment
can be Calibrated.