14S002R2_PC

9
DRAFT MALAYSIAN 14S002R2 STANDARD STAGE : PUBLIC COMMENT (40.20) DATE : 01/09/2014 - 31/10/2014 Ballasts for tubular fluorescent lamps - Part 2: Performance (Watt loss) requirements (Second revision) OFFICER/SUPPORT STAFF: (NIM / ija) ICS: 29.140.30 Descriptors: ballast, tubular, fluorescent, lamp, performance, watt loss © Copyright DEPARTMENT OF STANDARDS MALAYSIA For Public Comment

description

code

Transcript of 14S002R2_PC

  • DRAFT MALAYSIAN 14S002R2

    STANDARD STAGE : PUBLIC COMMENT (40.20)

    DATE : 01/09/2014 - 31/10/2014

    Ballasts for tubular fluorescent lamps - Part 2: Performance (Watt loss) requirements (Second revision)

    OFFICER/SUPPORT STAFF: (NIM / ija)

    ICS: 29.140.30 Descriptors: ballast, tubular, fluorescent, lamp, performance, watt loss

    Copyright

    DEPARTMENT OF STANDARDS MALAYSIA

    For P

    ublic

    Comm

    ent

  • 14S002R2

    STANDARDS MALAYSIA 2014 - All rights reserved i

    Contents

    Page Committee representation .......................................................................................................... ii Foreword .................................................................................................................................... iii 1 Scope ............................................................................................................................. 1 2 Normative references .................................................................................................... 1 3 General notes on tests .................................................................................................. 1 4 Marking .......................................................................................................................... 2 5 Watt loss ........................................................................................................................ 2 Annex A Watt loss test ........................................................................................................... 3

    For P

    ublic

    Comm

    ent

  • 14S002R2

    STANDARDS MALAYSIA 2014 - All rights reserved ii

    Committee representation The Industry Standards Committee on Electrical and Electronics Equipments and Accessories (ISC S) under whose authority this Malaysian Standard was developed, comprises representatives from the following organisations: Atomic Energy Licensing Board Department of Standards Malaysia Federation of Malaysian Manufacturers Jabatan Kerja Raya Malaysia Malaysian Association of Standards Users Malaysian Cable Manufacturers Association Malaysian Electrical Appliances and Distributors Association Malaysian Green Technology Corporation Ministry of Domestic Trade, Co-operatives and Consumerism Ministry of International Trade and Industry Multimedia University SIRIM Berhad (Secretariat) SIRIM QAS International Sdn Bhd Suruhanjaya Komunikasi dan Multimedia Malaysia Suruhanjaya Tenaga Tenaga Nasional Berhad The Electrical and Electronics Association of Malaysia Universiti Teknologi Malaysia Universiti Tenaga Nasional The Technical Committee on Lighting, Lamps and Accessories which developed this Malaysian Standard consists of representatives from the following organisations: Association of Consulting Engineers Malaysia Federation of Malaysian Manufacturers Jabatan Kerja Raya Malaysia Malaysia Green Building Confederation SIRIM Berhad (Secretariat) SIRIM QAS International Sdn Bhd (Product Certification and Inspection Department) SIRIM QAS International Sdn Bhd (Testing Services Department) Suruhanjaya Tenaga The Electrical and Electronics Association of Malaysia The Institution of Engineers, Malaysia

    For P

    ublic

    Comm

    ent

  • 14S002R2

    STANDARDS MALAYSIA 2014 - All rights reserved iii

    Foreword This Malaysian Standard was developed by a Technical Committee on Lighting, Lamps and Accessories under the authority of the Industry Standards Committee on Electrical and Electronics Equipments and Accessories. Major modifications in this revision are as follows: a) the title has been changed to Ballasts for tubular fluorescent lamps - Part 2: Performance

    (Watt loss) requirements; b) the scope has been changed as in clause 1; c) subclauses 3.1, 3.2, 4.1 and 4.2 have been deleted; d) clauses 5, 6, 7, 8, 9, 10, 11, 12 and 13 have been deleted; and e) Annexes A, B, C and D have been deleted. This Malaysian Standard cancels and replaces, MS 141:Part 2:1993, Specification for ballasts for tubular fluorescent lamps - Part 2: Performance requirements (First revision). Compliance with a Malaysian Standard does not of itself confer immunity from legal obligations.

    For P

    ublic

    Comm

    ent

  • 14S002R2

    STANDARDS MALAYSIA 2014 - All rights reserved 1

    Ballasts for tubular fluorescent lamps - Part 2: Performance (Watt loss) requirements

    1 Scope This Malaysian Standard specifies performance requirements for ballasts loss excluding resistance types, for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with tubular fluorescent lamps with pre-heated cathodes operated with or without a starter or starting device and having rated wattages, dimensions and characteristics as specified in MS IEC 60081 and MS IEC 60901.

    2 Normative references The following referenced documents are indispensable for the application of this standard. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. MS IEC 60081, Double-capped fluorescent lamps - Performance specifications MS IEC 60901, Single-capped fluorescent lamps - Performance specifications MS IEC 60921, Ballasts for tubular fluorescent lamps - Performance requirements MS IEC 61000-3-2, Electromagnetic compatibility (EMC) - Part 3-2: Limits - limits for harmonic current emissions (Equipment input current 16 A per phase) MS IEC 61347-1, Lamp controlgear - Part 1: General and safety requirements MS IEC 61347-2-8, Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps

    3 General notes on tests 3.1 One specimen shall be submitted to all tests. 3.2 In general all tests are made on each type of ballast or, where a range of similar ballasts is involved, for each rated wattage in the range or on a representative selection from the range as agreed with the manufacturer. 3.3 The test conditions specified in Annex A of MS IEC 60921, is applied together with the requirements of clause 5. 3.4 All ballasts specified in this standard shall comply with the requirements of MS IEC 61347-2-8, MS IEC 60921 and MS IEC 61000-3-2.

    For P

    ublic

    Comm

    ent

  • 14S002R2

    STANDARDS MALAYSIA 2014 - All rights reserved 2

    4 Marking Watt loss shall be marked either on the ballast or be made available in the manufacturers catalogue or the like.

    5 Watt loss The watt loss, when determined by the test method in Annex A, shall not exceed the marked value by more than 10 %, except where a tolerance of less than 10% is marked, in which case, this value shall be used to determine compliance.

    For P

    ublic

    Comm

    ent

  • 14S002R2

    STANDARDS MALAYSIA 2014 - All rights reserved 3

    Annex A (normative)

    Watt loss test

    A.1 The circuit shown in Figures A.1 shall be used for the determination of watt loss.

    A.2 The watt loss is determined by subtracting the lamp power from the total power consumed.

    A.3 Test method A.3.1 General The sequence described below shall be followed. A.3.2 Reference lamp stability (see clause A.1.4 of MS IEC 60921). With the stabilised power on, position the selector switch #1 and selector switch #2 at position #1. Allow the lamp to stabilise. After the lamp has stabilised move selector switch #2 to position #2. Record the readings for the followings: a) lamp voltage; b) lamp current; and c) lamp power. Check immediately that the readings obtained are the characteristics of a reference lamp. A.3.3 Measurement of lamp power Position selector switch #1 to position #2 and record the readings for the following: a) lamp voltage; b) lamp current; and c) lamp power. A.3.4 Measurement of total power consumed Position selector switch #2 to position #2 and record the readings for the total power consumed.

    For P

    ublic

    Comm

    ent

  • Figure A.1. Test circuit for determination of watt loss

    14

    S00

    2R

    2

    4

    ST

    AN

    DA

    RD

    S M

    ALA

    YS

    IA 2

    014 - A

    ll rights

    reserv

    ed

    For P

    ublic

    Comm

    ent

  • STANDARDS MALAYSIA 2014 - All rights reserved

    Acknowledgements Members of Technical Committee on Lighting, Lamps and Accessories Ir Haizan Hussein (Chairman) Jabatan Kerja Raya Malaysia Ms Nor Iratul Munirah Mazani (Secretary) SIRIM Berhad Ir Ahmad Rashidi Zainudin Association of Consulting Engineers

    Malaysia Mr Lim Kim Poi Federation of Malaysian Manufacturers Ir Looi Hip Peu Malaysia Green Building Confederation Mr Muhammad Nazif Zakaria SIRIM QAS International Sdn Bhd

    (Product Certification and Inspection Department)

    Mr Mohd Azmeer Ahmad SIRIM QAS International Sdn Bhd (Testing Services Department)

    Ir Francis Xavier Jacob Suruhanjaya Tenaga Mr Siew Choon Thye The Electrical and Electronics Association

    of Malaysia

    Ir Lim Kim Ten/Ir Lee Kok Chong The Institution of Engineers, Malaysia

    For P

    ublic

    Comm

    ent