13AB How to Get Started with VIO Server Planning and Best...
Transcript of 13AB How to Get Started with VIO Server Planning and Best...
![Page 1: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/1.jpg)
1
© 2016, 2017 IBM Corporation
Cognitive Systems
Session ID:
Agenda Key:
33CO How to Get Started with VIO Server Planning and Best PracticesGary Konicek ([email protected])IBM Lab Services
170294
33CO
© 2016, 2017 IBM Corporation
Cognitive Systems
2
Agenda
• VIOS General Planning References
• Installation Planning
• Virtual Storage / Tape Planning
• Virtual Network Planning
• Miscellaneous Tips
– Multipath Driver Considerations
– POWER8 Considerations
– HMC Considerations
![Page 2: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/2.jpg)
2
© 2016, 2017 IBM Corporation
Cognitive Systems
3
Where Do I Start with Planning & Installing VIOS
• IBM PowerVM Getting Started Guide– http://www.redbooks.ibm.com/redpieces/abstracts/redp4815.html
• IBM PowerVM Virtualization Introduction and Configuration– http://www.redbooks.ibm.com/redpieces/abstracts/sg247940.html
• PowerVM Managing and Monitoring– http://www.redbooks.ibm.com/redpieces/abstracts/sg247590.html
• IBM PowerVM Best Practices– http://www.redbooks.ibm.com/abstracts/sg248062.html
• VIOS Manual (POWER8) – Knowledge Center– http://public.dhe.ibm.com/systems/power/docs/hw/p8/p8hb1.pdf
© 2016, 2017 IBM Corporation
Cognitive Systems
4
Where Do I Start with Planning & Installing VIOS
• IBM Power Systems HMC Implementation and Usage Guide– http://www.redbooks.ibm.com/abstracts/sg247491.html?Open
– Version 7 and Classic focus
• IBM Power Systems HMC Implementation and Usage Guide– http://www.redbooks.ibm.com/abstracts/sg248334.html?Open
– Version 8 and Classic and Enhanced+ interface
• IBM i Virtualization and Open Storage white paper (2014)– http://IBM i Virtualization
![Page 3: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/3.jpg)
3
© 2016, 2017 IBM Corporation
Cognitive Systems
5
IBM i Virtualization Support Overview
• Note: Supported functions continue to evolve Review website
https://www.ibm.com/developerworks/community/wikis/home/wiki/IBM%20i%20Technology%20Updates/page/IBM%20i%20Virtualization%20Summary
© 2016, 2017 IBM Corporation
Cognitive Systems
VIOS Installation Planning
6
![Page 4: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/4.jpg)
4
© 2016, 2017 IBM Corporation
Cognitive Systems
7
What are you going to virtualize & how
• Processors, storage, memory, network, all of these or subset
• Which VIO functions to use
– Active memory sharing, shared storage pools, etc
• Storage virtualization – Internal storage, external storage (SAN), tape storage, N_Port ID (NPIV), virtual scsi (VSCSI)
• Number of VIO servers – 1, 2, 3, 4 or more per system
– Pair for production, pair for dev/test
– Pair for Ethernet, pair for SAN storage
• Boot VIO from internal disk or external storage
© 2016, 2017 IBM Corporation
Cognitive Systems
8
VIOS Sizing
• Recommended Minimum– 0.5 to 1.0 cores and 6-8 GB of memory, but depends on several factors
Storage/ethernet throughput, number of virtual adapters, number of cores hosted, etc.
• VIOS Sizing References– PowerVM Best Practices – Chapter 1.3
• http://www.redbooks.ibm.com/abstracts/sg248062.html• Disregard the comment about starting with 1.5 cores for vSCSI with IBM i
– VIOS Manual on Knowledge Center• http://public.dhe.ibm.com/systems/power/docs/hw/p8/p8hb1.pdf
• IBM Workload Estimator can be used to size VIOS– Use Collection Services data to input I/Os and throughput for storage and networking– Allocates 0.1 cores for the redundant VIOS
• Use VIOS Advisor, topas, or nmon to track utilization and make adjustments as needed
![Page 5: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/5.jpg)
5
© 2016, 2017 IBM Corporation
Cognitive Systems
9
VIOS Installation Planning – Install Disks
• When installing VIOS on internal disk– Order at least two disks per VIOS and use mirroring for protection– Must be seen as 512-byte sector disk. If install disk is not found, will need to reformat
using AIX Diagnostic CD• Download at
http://www14.software.ibm.com/webapp/set2/sas/f/diags/home.html• Load this CD and activate partition• Navigate menu options to reformat the disks or create RAID array• Shut down LPAR and then install with VIOS media
• When installing VIOS on external disk– Protect LUNs on the storage server– Use 512-byte sector LUNs for VIOS (AIX, pseries, etc.)– VIOS requires minimum of 30GB but use larger LUNs to store fixes, management
tools, optical media library, etc.• 70 – 100 GB LUNs are a common size for VIOS
© 2016, 2017 IBM Corporation
Cognitive Systems
10
Dual-VIOS Considerations on Internal Disk
• If dual VIOS will be implemented and you want to install both in a single system unit or CEC, order the Power Server with a split backplane
– Each VIOS must own a disk adapter for its OS
– Split backplane provides two disk adapters (one for each VIOS)
– BUT one adapter also owns the DVD
Disk DrivesAdapter Adapter
DVD
![Page 6: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/6.jpg)
6
© 2016, 2017 IBM Corporation
Cognitive Systems
11
Installing Second VIOS
• So if VIOS1 owns the DVD, how do you install VIOS2?
• Several options
– Use the install option on the HMC to install from:
• HMC image repository
• HMC’s DVD
– Requires external IP address for the HMC and the VIOS LPAR
• Use a NIM Server if you have one
– Swap the disk drives after installing VIOS1. Then install VIOS2 using the DVD on the Power System.
© 2016, 2017 IBM Corporation
Cognitive Systems
12
Installing second VIOS - External Storage
• If installing VIOS on SAN Storage, one approach is to build the second VIOS by using storage copy functions to create a copy of the first VIOS
• In addition to changing the host name and IP address, each VIOS needs it’s own unique RMC ID to ensure the HMC can access the second VIOS using RMC
• Follow these steps to generate a new RMC node id and restart the RMC subsystem– $ oem_setup_env
– # /usr/bin/odmdelete -o CuAt -q 'attribute=node_uuid‘
– # /usr/sbin/rsct/bin/mknodeid –f
– # /usr/sbin/rsct/install/bin/recfgct
![Page 7: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/7.jpg)
7
© 2016, 2017 IBM Corporation
Cognitive Systems
13
Network Requirements for VIOS
• Each VIOS needs an IP address on the external network
• The IP address needs to be in a subnet that allows access to the external IP address of the HMC
• Ensure your network team activates the IP addresses on the network switch ports
• Ensure one ethernet port for each VIOS is cabled to the ethernet switch(es)
© 2016, 2017 IBM Corporation
Cognitive Systems
Virtual Storage and Tape Planning for IBM i LPARs
14
![Page 8: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/8.jpg)
8
© 2016, 2017 IBM Corporation
Cognitive Systems
15
Planning for Virtualization of Internal Disk to IBM i Client LPARs
• If you plan to protect the disks by building RAID-5 or RAID-6 arrays in VIOS– Order IBM i drives– Can reuse drives that were previously owned by an IBM i LPAR– If AIX drives were ordered, reformat to 528-byte sectors using SAS RAID Array Manager in AIX
• Reformat could take a long time so plan for it!
• If you plan to protect the disks by mirroring on IBM i– Order AIX drives– If IBM drives were ordered or reusing i drives, reformat to 512 byte sectors using SAS RAID
Array Manager in AIX– Use RAID-0 on VIOS
• In all cases, you will lose up to 1/9th of the storage PLUS protection for RAID or mirroring
© 2016, 2017 IBM Corporation
Cognitive Systems
16
Planning for Virtualization of External Storage to IBM i Client LPARs
• Storage Volumes do not have to be the size of a physical disk on the storage server– But the number of volumes is important for IBM i workloads
• More volumes typically result in better I/O performance
• All volumes in an IBM i LPAR should be the same size
• Recommended minimum number of LUNs per IBM i LPAR = 6
• Consider storage usage for 512 to 520-byte sector conversion – Results in 1/9th of storage used for IBM i tag bytes when virtualizing storage from V7000/V3700, XIV, etc.– Exception: Not an issue with DS8000 LUNs which are 520-byte sector for IBM i
• When using vSCSI, assign physical volumes to IBM i LPARs
• Use Disk Magic tool to size proper number of storage volumes, physical disks, storage controllers, etc.
![Page 9: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/9.jpg)
9
© 2016, 2017 IBM Corporation
Cognitive Systems
17
EMC
IBM i
FCPVIOS
FC HBAs
VIOS
FC HBAs
DS8000
• All storage subsystems* and internal storage
supported
• Storage assigned to VIOS first, then virtualized
to IBM i
• Some storage subsystems and some FC tape libraries
supported
• Storage mapped directly to Virtual FC adapter in IBM
i, which uses N_Port on FC adapter in VIOS
NPIV
IBM i
VIOS
FC HBAs
XIV
generic scsi disk
generic scsi disk
DS3500
VIOS
FC HBAs
SAN
SCSI
VSCSI
* See following charts for list of IBM supported storage devices
V7000
DS8000
SAN
V7000
© 2016, 2017 IBM Corporation
Cognitive Systems
18
Requirements for NPIV with VIOS and IBM i Client
Partitions
• Must use 8 Gb or 16 Gb fiber channel adapters on the Power System and assign to VIOS partitions
• Must use a fiber channel switch to connect Power System and Storage Server
• Fiber Channel switch must be NPIV-capable
• Storage Server must support NPIV as an attachment between VIOS and IBM i
![Page 10: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/10.jpg)
10
© 2016, 2017 IBM Corporation
Cognitive Systems
19
IBM Storage system support
• Type of support may vary (i.e.)– NPIV or VSCSI
– Direct or via SAN switch
• Storage supported varies – see IBM System Storage Interoperability Center http://www-03.ibm.com/systems/support/storage/ssic/interoperability.wss
• IBM i POWER External Storage Support Matrix – Quick reference document
– http://www.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/PRS4563
© 2016, 2017 IBM Corporation
Cognitive Systems
20
IBM Storage System Interoperability Center• Example from website
![Page 11: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/11.jpg)
11
© 2016, 2017 IBM Corporation
Cognitive Systems
21
IBM i POWER External Storage Support Matrix – POWER8 Example
© 2016, 2017 IBM Corporation
Cognitive Systems
22
Redundant VIOS Support–Enables utilization of redundant VIOS partitions with 1 set of storage LUNs
–Improves availability of virtualized environment
–Each VIOS needs their own unique storage adapters
–External SAN Storage required
• Internal disk is controlled by a single host or server
Power Hypervisor
VIOS VIOS
![Page 12: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/12.jpg)
12
© 2016, 2017 IBM Corporation
Cognitive Systems
23
Protection Options
VIOS
VIO Client VIO Client
VIOS VIOS
M
MMirror
VIOS
Multi-path
VIOS
Multi-path
VIO Client
MPIO
Internal Storage Internal Storage SAN-Attached Storage
© 2016, 2017 IBM Corporation
Cognitive Systems
SAN Switch
NPIV Disk Configuration
SAN Switches
IBM i LPARs
fcs0 C2-T1
fcs1C2-T2
VIOS 1
VIOS 2
31
41
52
62
32
42
51
61
fcs2C5-T1
fcs3C5-T2
A
B
SAN Switch
LPAR462
61
SAN Switch
LPAR352
51
SAN Switch
LPAR242
41
SAN Switch
LPAR132
31
Virtual Physical
Virtual Physical
C0xx00
C0xx02
C0xx04
C0xx06
C0xx08
C0xx0a
C0xx0c
C0xx0e
LPAR2 Disk
LPAR1 Disk
LPAR3 Disk
LPAR4 Disk24
![Page 13: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/13.jpg)
13
© 2016, 2017 IBM Corporation
Cognitive Systems
25
Planning for Tape Devices with VIOS and IBM i
https://www.ibm.com/developerworks/community/wikis/home/wiki/IBM Removable Media on IBM i
© 2016, 2017 IBM Corporation
Cognitive Systems
SAN Switch
NPIV Tape Configuration
Tape F
Tape E
Tape D
Tape C
Tape B
Tape A
SAN Switches
IBM i LPARs
fcs4C4-T1
fcs5C4-T2
VIOS 1
VIOS 2
81
83
86
88
82
84
85
87
fcs4C6-T1
fcs5C6-T2
A
B
SAN Switch
LPAR488
87
SAN Switch
LPAR386
85
SAN Switch
LPAR284
83
SAN Switch
LPAR182
81
Control Path 1
Control Path 2
Virtual Physical
Virtual Physical
C0xx20
C0xx22
C0xx24
C0xx26
C0xx28
C0xx2a
C0xx2c
C0xx2e
26
![Page 14: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/14.jpg)
14
© 2016, 2017 IBM Corporation
Cognitive Systems
Virtual Network Planning
27
© 2016, 2017 IBM Corporation
Cognitive Systems
28
Network Virtualization Design Guidelines• Shared ethernet adapters can be built using one physical ethernet port or an
aggregated link comprised of multiple physical ports
VIOS IBM i
Client
Hyp
erv
isor
Switch
PV
ID =
15
PV
ID =
15
CMNx
Virt 1GbEnt 2
Virt
Ent 0
Phy
Ent 1
Phy
Ent3
SEA
VIOS IBM i
Client
Ent4
SEA
Hyp
erv
isor
Switch
PV
ID =
15
PV
ID =
15
Ent 3
Aggr
CMNx
Virt1GbEnt 2
Virt
Ent 0
Phy
Ent 1
Phy
![Page 15: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/15.jpg)
15
© 2016, 2017 IBM Corporation
Cognitive Systems
29
Network Virtualization Design Guidelines (cont.)
• Simple Design for IBM i client LPARs:– One shared ethernet adapter per network subnet per VIOS– i.e., SEA #1 for 123.123.111.xxx and SEA #2 for 123.123.222.xxx
• More Complex Design for IBM i client LPARs– Split a single shared ethernet adapter over multiple network subnets using VLANs – Network switch must be aware of and configured for each VLAN– By default, IBM i doesn’t recognize VLAN tags so PVID in IBM i virtual adapter needs to match a secondary VLAN in
the VIOS virtual adapter
• Recommend using a separate port for management of VIOS itself and other ports for client LPARs
• Duplicate the above requirements for each VIOS
• Use Performance Tools TCP/IP report to identify bandwidth requirements
© 2016, 2017 IBM Corporation
Cognitive Systems
30
Example: Network Bandwidth Planning
VIOS1
ent0
C10-T1
ent1
C10-T2
ent2
C10-T3
ent3
C10-T4
VIOS2
ent0
C11-T1
ent1
C11-T2
ent2
C11-T3
ent3
C11-T4
1Gb Management Port
3Gb Link Virtualized
to IBM i LPARs
Primary
1Gb Management Port
3Gb Link Virtualized
to IBM i LPARs
Failover
VIOS1
ent0
C10-T1
ent1
C10-T2
ent2
C10-T3
ent3
C10-T4
VIOS2
ent0
C11-T1
ent1
C11-T2
ent2
C11-T3
ent3
C11-T4
1Gb Management Port
2Gb Link Virtualized
to IBM i LPARs
Primary
1Gb Management Port
2Gb Link Virtualized
to IBM i LPARs
Failover
Single Subnet
1Gb Link Virtualized
to IBM i LPARs
Failover
1Gb Link Virtualized
to IBM i LPARs
Primary
Two Subnets
![Page 16: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/16.jpg)
16
© 2016, 2017 IBM Corporation
Cognitive Systems
31
Example: Network Bandwidth Planning - Continued
VIOS1
ent0
C10-T1
ent1
C10-T2
ent2
C10-T3
ent3
C10-T4
VIOS2
ent0
C11-T1
ent1
C11-T2
ent2
C11-T3
ent3
C11-T4
1Gb Management Port
6Gb Link Virtualized
to IBM i LPARs
Primary
1Gb Management Port
6Gb Link Virtualized
to IBM i LPARs
Failover
VIOS1
ent0
C10-T1
ent1
C10-T2
ent2
C10-T3
ent3
C10-T4
VIOS2
ent0
C11-T1
ent1
C11-T2
ent2
C11-T3
ent3
C11-T4
1Gb Management Port
4Gb Link Virtualized
to IBM i LPARs
Primary
1Gb Management Port
4Gb Link Virtualized
to IBM i LPARs
Failover
Single Subnet
2Gb Link Virtualized
to IBM i LPARs
Failover
2Gb Link Virtualized
to IBM i LPARs
Primary
Two Subnets
ent0
C6-T1
ent1
C6-T2
ent2
C6-T3
ent3
C6-T4
ent0
C6-T1
ent1
C6-T2
ent2
C6-T3
ent3
C6-T4
ent0
C12-T1
ent1
C12-T2
ent2
C12-T3
ent3
C12-T4
ent0
C12-T1
ent1
C12-T2
ent2
C12-T3
ent3
C12-T4
© 2016, 2017 IBM Corporation
Cognitive Systems
Miscellaneous Tips
32
![Page 17: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/17.jpg)
17
© 2016, 2017 IBM Corporation
Cognitive Systems
33
Multipath Device Driver Considerations
• For IBM SAN storage, Subsystem Device Driver Path Control Module (SDDPCM) multi-pathing software can be installed on each VIOS
– Provides load balancing and redundancy support
– Replaces the built in multipath support
– SDDPCM Support Matrix
• http://www.ibm.com/support/docview.wss?rs=540&context=ST52G7&dc=DA400&uid=ssg1S7001350
– Not needed in VIOS for IBM i support
• When using non-IBM SAN storage, you may need to install the vendor’s multipath device drivers
– Contact vendor for requirements
© 2016, 2017 IBM Corporation
Cognitive Systems
34
SDDPCM Download Info• http://www-01.ibm.com/support/docview.wss?uid=ssg1S4000201• SDDPCM User’s Guide also located on this page• Google ‘SDDPCM Download’ for latest version info
• See Chapter 3 of SDDPCM User’s Guide• Might need to update SDDPCM host attachment code and fibre channel firmware
first• Install SDDPCM driver• If updating earlier versions, might need to delete earlier version first – read user’s
guide
![Page 18: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/18.jpg)
18
© 2016, 2017 IBM Corporation
Cognitive Systems
35
POWER8 Considerations
• New E870C and E880C systems do not have disk in the system units so VIOS install disks need to be in EXP24S I/O drawer
• IBM recommendation for Dual-VIOS on E870C/E880C:
– http://www.redbooks.ibm.com/redpieces/abstracts/redp5137.html
– Section 2.10.2 recommends 4 PCIe SAS Adapters (FC 5901) – two for each VIOS
© 2016, 2017 IBM Corporation
Cognitive Systems
36
HMC Considerations
• HMC provides simple browser interfaces to configure VIOS, virtual storage and virtual networking
• Recommend using at least V7.7.5 to get most of the virtual management support
– Recommend at least V7.7.7 for remote install
– VIOS is shipped with V8 on new HMCs, but you can upload VIOS image to older HMCs at V7.7.7
• V8.8.2 or later provides two interfaces – Classic and Enhanced
– Can change interfaces at log in
– Enhanced version is a new template based interface
![Page 19: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/19.jpg)
19
#COMMONS17www.common.org
Don’t Forget Your Session Surveys
• Sign in to the Online Session Guide (www.common.org/sessions)
• Go to your personal schedule
• Click on the session that you attended
• Click on the Feedback Survey button located above the abstract
Completing session surveys helps us plan future programming and provides feedback used in speaker awards. Thank you for your participation.
© 2016, 2017 IBM Corporation
Cognitive Systems
https://facebook.com/IBMPowerSystems
https://twitter.com/IBMPowerSystems
https://www.linkedin.com/company/ibm-power-systems
IBM Power Systems Official Channels:
http://www.youtube.com/c/ibmpowersystems
https://www.ibm.com/blogs/systems/topics/servers/power-
systems/
Power Systems Social Media
![Page 20: 13AB How to Get Started with VIO Server Planning and Best Practicesschd.ws/hosted_files/commons17/63/33CO VIOS Planni… · · 2017-05-081 © 2016, 2017 IBM Corporation Cognitive](https://reader031.fdocuments.in/reader031/viewer/2022021818/5aaa6f777f8b9a9a188e35cd/html5/thumbnails/20.jpg)
20
© 2016, 2017 IBM Corporation
Cognitive Systems
39
More to Follow:
Blogs to Follow More to Follow Hashtags To Use
• IBM Systems Magazine You and I (Steve Will)
• IBM Systems Magazine i-Can (Dawn May)
• IBM Systems Magazine: iDevelop (Jon Paris and
Susan Gantner)
• IBM Systems Magazine: iTalk with Tuohy
• Aaron Bartell Blog
• Steve Pitcher Blog
• Trevor Perry Blog
• IBM DB2 for i (Mike Cain)
• IBM DB2 Web Query for i (Doug Mack)
• Modern-i-zation (Tim Rowe)
@IBMSystems@COMMONug
@IBMChampions@IBMSystemsISVs
@LinuxIBMMag@OpenPOWERorg
@AIXMag@IBMiMag
@ITJungleNews@SAPonIBMi@SiDforIBMi
@IBMAIXeSupp@IBMAIXdoc
#PowerSystems
#IBMi
#IBMAIX
#POWER8
#LinuxonPower
#OpenPOWER
#HANAonPower
#ITinfrastructure
#OpenSource
#HybridCloud
#BigData