    Dear Melco Customer,

    If you own a M elco EM T 10/12T multi-head machine, DO NO T attempt to upgrade your current

    machine M CPS software with this version. This MCPS software upgrade is ONLY designatedfor the EMB 10/6T multi-head machine.

    You may have a newer version of software already installed, or you may need a hardware

    upgrade before you can install this software successfully (e.g. EM B 10/6T requires EPRO M s with

    software version 1.2 for head nodes and 1.1 for bed node).

    This M CPS release consists of two (2) installation disks which include the following versions of the

    program and RSA files:

    M CPS program version 1.24

    RSA (EM B 10/6T) version 1.23

    To check which M CPS program and RSA versions are currently running on your machine, perform

    the following simple procedure:

    1. In the M CPS Control Panel screen, click the A dvanced button.

    2. The Program Version and RSA version numbers are identif ied in the upper left area of the

    A dvanced screen which is now showing.

    Important!

    This document contains information about M elco C ontrol Panel Software, Release 2001-10. This

    information may not be included in the machine operation manual. Please read these release

    notes carefully before installing software on your machine. Thank You.

    Release Notes forMelco Control Panel Software

    Release 2001-10

    Document Part Number 13348 Rev.G

    July, 2001

  • 7/28/2019 13348g

    2/5

    2 of 5 M elco Embroidery Systems

    Enhancements and Fixes With Release 2000-19:

    1. Design Q ueue added to the Control panel.

    2. Dual hoop and sash frame operations are enabled.

    3. A spontanious error was appearing that stated Bed Node Not Responding at the end of a

    design. This has been corrected.

    4. M achine is operable with less than 6 heads O N when a head with a defective jump stitch or

    takeup lever motor is turned O FF.

    5. A n error message is generated for an invalid color change encoder detection (see New

    M essages with this release, #108).

    6. To prevent false error message reporting, fault detecting is now disabled when E-Stop function

    is engaged.

    7. Backstitching that previously may have occurred outside some small lettering, now remains

    within the body of the letters.

    8. To eliminate undesirable and unnecessary error message reporting while embroidering, the

    color change direction encoder is disabled during embroidery.

    Enhancements and Fixes With Release 2000-50:

    1. A dded feature to check the size of data log file. If the file size exceeds 4M B a dialog will

    appear that suggests that the user purge old logfile records. A button is available to take the

    user directly to the Purge Record dialog.

    2. Limited the statistic error message report to 3000 entries to prevent system crash.

    3. A dded " Save" button to the error report dialog. A llows user to save error messages to a text

    file.

    4. Changed error query to eliminate non-critical errors and messages from the report.

    5. Changed the maintenance step through dialogs to prevent user from inadvertently clicking

    outside the dialog and locking up the system.

    6. Fixed maintenance timer problem.

    7. A dditional start data validation added to database record purging.

    8. Fixed security problem that forced users to login twice if security was enabled.

    9. Removed machine type configuration program, now now it sets automatically.

  • 7/28/2019 13348g

    3/5

    13348, Rev G 3 of 5

    Enhancements and Fixes With Release 2001-10:

    1. Fixed a problem with large designs failing to trace properly.

    2. Fixed a problem concerning three files not being installed properly.

    Installation Options:

    A s with many things, there is more than one way to accomplish a task. The same is true with

    installing updated embroidery machine software. A lthough M elco recommends the first

    installation option, we realize you may want to use the alternate second option. Refer to the

    attached pages for the two installation options available for reinstalling this updated M CPS

    software release. Then use whichever method is most comfortable to you.

    Installation Option #1

    Install new M CPS software without removing the previous version from the Start U p G roup - Thisis M elcos recommendation.

    1. Exit M CPS, restart windows without starting M CPS.

    2. Insert Disk #1 of the M CPS software.

    3. Click Start at the bottom left of the Windows screen.

    4. Select Run and type a:setup.

    5. Click O K and follow the on-screen instructions:

    Welcome - click NextSoftware License A greement - read carefully, then click Yes (or No)

    Select C omponents: check Program files, check RSA fi les - click Next

    Insert Disk #2 when prompted - click O K

    (If an error message appears asking if you want to replace

    file BC450RTL.DLL , click NO . This file does not need to be replaced.)

    M CPS icon to appear on desktop - click Yes

    6. Remove disk.#2

    Restart the computer - click Yes, click O K

    Note: If your machine is networked, you should enable ethernet in the MCPS Configprogram before running MCPS.

  • 7/28/2019 13348g

    4/5

    4 of 5 M elco Embroidery Systems

    Installation Option #2

    Remove current version of M CPS software from the the Start Up G roup before installing the new

    software.

    Remove MCPS from Start Up Group

    1. Click Start at the bottom left of the Windows screen.

    2. Select Settings and then Task Bar and Start M enu.

    3. Click the Start M enus Program tab.

    4. Click the Remove button and locate the Start Up folder.

    5. O pen the Start up folder and highlight M CPS.

    6. Click Remove, and click on Yes to any dialog asking if you are sure.

    7. Click C lose, then OK to return to the Windows desktop.

    Install new MCPS software

    1. Insert Disk #1 of the M CPS software

    2. Click Start at the bottom left of the Windows screen.

    3. Select Run and type a:setup.

    4. C lick O K and follow the on-screen instructions:

    Welcome - click Next

    Software License A greement - read carefully, then click Yes (or No)

    Select C omponents: check Program files, check RSA fi les - click Next

    Insert Disk #2 when prompted - click O K

    M CPS icon to appear on desktop - click Yes

    5. Remove disk.#2

    Restart the computer - click Yes, click O K

    6. Click Start at the bottom left of the Windows screen.

    7. Select Programs / M elco Apps / M CPSConfig.

    8. Choose machine type and click O K .

    Note: If your machine is networked, you should enable ethernet in the MCPSConfigprogram before running MCPS.

  • 7/28/2019 13348g

    5/5

    13348, Rev G 5 of 5

    Enabling Spider Hoops

    If you have purchased the double spider hoops along with the Sash Frame O ption for your EM B

    10/6 T peripheral, you will need to enable the double spider hoops in M CPS.

    To enable the double spider hoops in M CPS perform the following steps:

    1. Start Windows Explorer from the Start/Programs menu.

    2. Click on the Windows folder under Drive C .

    3. Locate and double click on the file mcps.ini, this will open the file in Notepad.

    4. Under the line [M ode] add a line with the text Spiders = 1 .

    5. Save the file, then close Notepad and Windows Explorer.

    6. Restart M CPS, the double spider hoops will be available in the Hoop List on the Control Panel.

    Note: You can also refer to your machine Operators Manual for assistance on enablingspider hoops.