12.09.25 NK Acoustic field measurements MT- · PDF filemetal-Profile (Knauf CW), e = 625 mm;...

9
Acoustic performance tests on CLT Field measurements at the MT-Hotel Location: MT-Hotel (Incoming Center Murtal) Hauptstraße 242 AT - 8740 Zeltweg Performed by: Schallschutz im Holzbau SSIH Dipl. Ing. (FH) Hans-Peter Buschbacher Scheuchenstulstraße 11 D-83024 Rosenheim E-Mail: [email protected] Customer: Stora Enso WP Bad St. Leonhard GmbH Wisperndorf 4 9462 Bad St. Leonhard Austria Date of testing: 24.05.2012 The tests were performed according to following international standards: airbourne sound: DIN EN ISO 140-4: 1998-12 Field measurements of airborne sound insulation between rooms. Rating according to DIN EN ISO 717-1 : 2006-11 impaced sound: DIN EN ISO 140-7 : 1998-12 Field measurements of impact sound insulation of floors Rating according to DIN EN ISO 717-2 : 2006-11 Note: The results of field measurements are usually lower than the laboratory measured values. The difference between the results is due to flanking transmission on site.

Transcript of 12.09.25 NK Acoustic field measurements MT- · PDF filemetal-Profile (Knauf CW), e = 625 mm;...

Page 1: 12.09.25 NK Acoustic field measurements MT- · PDF filemetal-Profile (Knauf CW), e = 625 mm; filled with 50 mm mineral wool (free-standing) insulation stripe (between metal-profiles

Acoustic performance tests on CLT

Field measurements at the MT-Hotel

Location: MT-Hotel (Incoming Center Murtal) Hauptstraße 242 AT - 8740 Zeltweg Performed by: Schallschutz im Holzbau SSIH Dipl. Ing. (FH) Hans-Peter Buschbacher Scheuchenstulstraße 11 D-83024 Rosenheim E-Mail: [email protected] Customer: Stora Enso WP Bad St. Leonhard GmbH Wisperndorf 4 9462 Bad St. Leonhard Austria Date of testing: 24.05.2012 The tests were performed according to following international standards: airbourne sound: DIN EN ISO 140-4: 1998-12 Field measurements of airborne sound insulation between

rooms. Rating according to DIN EN ISO 717-1 : 2006-11 impaced sound: DIN EN ISO 140-7 : 1998-12

Field measurements of impact sound insulation of floors Rating according to DIN EN ISO 717-2 : 2006-11

Note: The results of field measurements are usually lower than the laboratory measured values. The difference between the results is due to flanking transmission on site.

Page 2: 12.09.25 NK Acoustic field measurements MT- · PDF filemetal-Profile (Knauf CW), e = 625 mm; filled with 50 mm mineral wool (free-standing) insulation stripe (between metal-profiles

Object description

location: Zeltweg – Austria

client: Fritz Mayer & Tieber Busreisen

architect: KLMS Architekten, Gleisdorf

planning of the timber construction:

ZMP GmbH, Grambach

assembly of the timber construction:

Zimmerei ALPE GmbH, Fohnsdorf

Type of construction:

cellar and ground floor in reinforced concrete,

1st and 2nd floor in Stora Enso CLT (Cross laminated timber)

quantity of CLT: 450 m³

opening: May 2012

Click the link to see a fast motion video of the erection:

http://www.youtube.com/watch?v=e9wLbbEWpFM (Source: ZMP)

(Source: MT-Hotel GmbH)

Page 3: 12.09.25 NK Acoustic field measurements MT- · PDF filemetal-Profile (Knauf CW), e = 625 mm; filled with 50 mm mineral wool (free-standing) insulation stripe (between metal-profiles

Ceilings:

Second floor

First floor

Connection node: external wall – ceiling – partition wall (visible CLT)

Connection node: corridor wall (cladded) – ceiling - partition wall (with drying line)

Bearing support: with elastic intermediate layer (Sylomer Typ M) on the upper side.

Wall anchoring: with sound insulated mounting brackets on the upper side.

Source-

room

Receive-

room

Source- room

Receive- room

Page 4: 12.09.25 NK Acoustic field measurements MT- · PDF filemetal-Profile (Knauf CW), e = 625 mm; filled with 50 mm mineral wool (free-standing) insulation stripe (between metal-profiles

Floor 1:

CLT 165mm

Building components:

10 mm

60 mm

--

30 mm

50 mm

--

165 mm 3 mm

70 mm

12,5 mm

carpet

cement screed

plastic separation layer

impact sound absorbing subflooring (Isover TDPT 25; s´ = 19 MN/m³)

gravel fill, loos filling

trickling protection

StoraEnso CLT, 5 Layers

insulation stripe

nonius suspension for CD 60x27 Universal Bracket,

the space between is filled with 50mm mineral wool

gypsum plasterboard

Weighted Standardized Level Difference: DnTw (C;Ctr): 63 (-3;-9) dB (Source: report 2012-05-24-0012-L)

Weighted Standardized Impact Sound Pressure Level: L´nT,w (CI): 35 (6) dB (Source: report 2012-05-24-0012-T)

Page 5: 12.09.25 NK Acoustic field measurements MT- · PDF filemetal-Profile (Knauf CW), e = 625 mm; filled with 50 mm mineral wool (free-standing) insulation stripe (between metal-profiles

Floor 2:

CLT 223mm

Building components:

10 mm

60 mm

--

30 mm

50 mm

--

223 mm 3 mm

70 mm

12,5 mm

carpet

cement screed

plastic separation layer

impact sound absorbing subflooring (Isover TDPT 25; s´ = 19 MN/m³)

gravel fill, loos filling

trickling protection

StoraEnso CLT, 7 Layers

insulation stripe

nonius suspension for CD 60x27 Universal Bracket,

the space between is filled with 50mm mineral wool

gypsum plasterboard

Weighted Standardized Level Difference: DnTw (C;Ctr): 62 (-3;-9) dB (Source: report 2012-05-24-0149-L)

Weighted Standardized Impact Sound Pressure Level: L´nT,w (CI): 39 (7) dB (Source: report 2012-05-24-0149-T)

Page 6: 12.09.25 NK Acoustic field measurements MT- · PDF filemetal-Profile (Knauf CW), e = 625 mm; filled with 50 mm mineral wool (free-standing) insulation stripe (between metal-profiles

Walls:

Second floor

Connection node: external wall – ceiling – partition wall (visible CLT)

Connection node: corridor wall (cladded) – ceiling - partition wall (with drying line)

Bearing support: with elastic intermediate layer (Sylomer Typ M) on the upper side.

Wall anchoring: with sound insulated mounting brackets on the upper side.

Receive-

room Source-

room

dfdffs

Receive- room

Receive- room

Source-

room

Wall

1

Wall

2

Wall

3

Page 7: 12.09.25 NK Acoustic field measurements MT- · PDF filemetal-Profile (Knauf CW), e = 625 mm; filled with 50 mm mineral wool (free-standing) insulation stripe (between metal-profiles

Wall 1: Compartment wall – drying line

Building components:

12,5 mm

12,5 mm

50 mm

5 mm

97 mm

20 mm

5 mm

97 mm

5 mm

50 mm

12,5 mm

12,5 mm

gypsum plasterboard

gypsum plasterboard

metal-Profile (Knauf CW), e = 625 mm; filled with 50 mm mineral wool (free-standing)

insulation stripe (between metal-profiles and CLT)

StoraEnso CLT 97 C3s

Sound absorbing insulation material, (Knauf TPT, s´= 40 MN/m³)

space

StoraEnso CLT, 3 Layers

insulation stripe (between metal-profiles and CLT)

Metal-Profile (Knauf CW), e = 625 mm; filled with 50 mm mineral wool (free-standing)

gypsum plasterboard

gypsum plasterboard

+ app. 870 mm high, veneer wall panelling (on both sides, unknown composition)

Weighted Standardized Level Difference: DnTw (C;Ctr): 55 (-4;-10) dB (Source: report 2012-05-24-0028)

Page 8: 12.09.25 NK Acoustic field measurements MT- · PDF filemetal-Profile (Knauf CW), e = 625 mm; filled with 50 mm mineral wool (free-standing) insulation stripe (between metal-profiles

Wall 2: Compartment wall – visible CLT

Building components:

97 mm

12,5 mm

30 mm

30 mm

5 mm

97 mm

StoraEnso CLT, 3 Layers

gypsum plasterboard

sound absorbing insulation material, (Knauf TPT, s´= 40 MN/m³)

sound absorbing insulation material, (Knauf TPT, s´= 40 MN/m³)

space

StoraEnso CLT, 3 Layers

+ app. 870 mm high, veneer wall panelling (on both sides, unknown composition)

Weighted Standardized Level Difference: DnTw (C;Ctr): 61 (-3;-10) dB (Source: report 2012-05-24-0032)

Page 9: 12.09.25 NK Acoustic field measurements MT- · PDF filemetal-Profile (Knauf CW), e = 625 mm; filled with 50 mm mineral wool (free-standing) insulation stripe (between metal-profiles

Wall 3: Compartment wall - corridor wall

Building components:

12,5 mm

12,5 mm

50 mm

5 mm

97 mm

12,5 mm

gypsum plasterboard (corridor)

gypsum plasterboard

Metal-Profile (Knauf CW), e = 625 mm; filled with 50 mm mineral wool (free-standing)

insulation stripe (between metal-profiles and CLT)

StoraEnsoCLT, 3 Layers

gypsum plasterboard (room)

+ app. 870 mm high, veneer wall panelling (on one side, unknown composition)

Weighted Standardized Level Difference: DnTw (C;Ctr): 60 (-2;-8) dB (Source: report 2012-05-24-0170)

NK 2012.09.25