Jennmar Australia Clip Up Service Hanger Clip Up Service Hanger.
12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …
Transcript of 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …
12" MAX MAIN TEE
OVERHANG, TYP.
48" MAX MAIN TEE SPACING, TYP.
12" MAX BEAM OVERHANG, TYP.
*SEE DETAIL A1.1 FOR AVAILABLE BEAM SIZESINTERIOR INSTALLATION
6" BEAM SPACING SHOWN,
ACTUAL CAN VARY, TYP.
BEAM SPECIFICATIONSSEE DETAIL A1.1
SUSPENSION SPECIFICATIONSSEE DETAIL A1.2
FIXTURE RECOMMENDATIONSSEE DETAILS A1.8 & A1.9
12 GA HANGER WIRE, BY OTHERS,NOT BY CERTAINTEEDSEE DETAIL A1.2
48" MAX HANGER WIRE SPACING, TYP.
HANGER BRACKETASSEMBLYSEE DETAIL A1.4
PLENUM ACCESSSEE DETAIL A1.7
15/16" HEAVY DUTY CLASS MAIN TEEPER ASTM C635, BY OTHERS, TYP.
2"
6"
TYPICAL SYSTEM SECTIONSCALE: 3" = 1'-0"
TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.
2" HANGER BRACKETASSEMBLY
2" X 6" TAVOLAPRIME BEAM*
15/16" HEAVY DUTY CLASS T-GRIDPER ASTM C635 BY OTHERSSEE DETAIL A1.2
BEAM SPLICESEE DETAIL A1.4
BEAM END CAPSEE DETAIL A1.6
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
OVERALL ISOMETRIC VIEW
PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.0
SCALE: AS SHOWN
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
BEAM SIZES
BEAM SIZES ARE DIMENSIONED WIDTH X HEIGHT
PROFILES ARE AVAILABLE IN 1/2" INCREMENTS, CONTACTCERTAINTEED FOR OTHER SIZES
MAX LENGTHS MAY BE PROFILE-SPECIFIC, CONTACT CERTAINTEED
BEAM LENGTHS AVAILABLE IN ±1/4" INCREMENTS, MINIMUMQUANTITIES MAY APPLY
BEAM MATERIAL
.032", .040" ALUMINUM
BEAM FINISHES
PAINTED & POWDER COATED
DECORATED WOOD FINISH (POWDER COATED)
LAMINATED WOOD FINISH (FILM)
PERFORATIONS
STANDARD PERFORATION BORDERS ARE 1/4" NOM.
PERFORATION106
% OPEN16.0%
115 12.0%119 8.0%
1" - 24" WIDTH
TAVOLAPRIME
2" -
6" H
EIGH
T
1", 112", 2" WIDTH
TAVOLATALL
15" M
AX H
EIGH
T
12'-0" MAX BEAM LENGTH
HEIG
HT
BEAM END & SIDE VIEWSCALE: NOT TO SCALE
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
BEAM SPECIFICATIONS
PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.1
SCALE: AS SHOWN
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
TYPICAL SECTIONSSCALE: 3" = 1'-0"INTERIOR INSTALLATION
48" MAX MAIN TEE SPACING, TYP.
12" MAX BEAM OVERHANG, TYP.
48" MAX HANGER WIRE SPACING, TYP.
TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.
2" HANGER BRACKET ASSEMBLY
15/16" CROSS TEE 48" O.C. MAXALONG MAIN TEE, TYP.
2" X 6" TAVOLA PRIME BEAMSHOWN, ALL SIZES SIMILAR
TWO (2) MIN #6 FASTENERSPER BEAM/HANGERBRACKET, BY OTHERS, TYP.
12 GA HANGER WIRE BY OTHERS, TYP.
12" MAX MAIN TEE
OVERHANG, TYP.
12 GA HANGER WIRE BY OTHERS, TYP.
6" BEAM SPACING SHOWN,
ACTUAL CAN VARY, TYP.
2" X 6" TAVOLA PRIME BEAMSHOWN, ALL SIZES SIMILAR
15/16" CROSS TEE 48" O.C. MAX ALONGMAIN TEE, BY OTHERS, TYP.
TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.
2" HANGER BRACKET ASSEMBLY
48" MAX MAIN TEE SPACING, TYP.12 GA HANGER WIREBY OTHERS, TYP.
12" MAX BEAMOVERHANG, TYP.
2" X 6" TAVOLA PRIME BEAMSHOWN, ALL SIZES SIMILAR
2" X 6" TAVOLA PRIMEEND CAP
6" BEAM SPACING SHOWN,ACTUAL CAN VARY, TYP.
12" MAX MAIN TEEOVERHANG, TYP. 48" MAX HANGER WIRE SPACING, TYP.
2" HANGER BRACKETASSEMBLY
15/16" CROSS TEE 48" O.C.MAX ALONG MAIN TEE, BYOTHERS, TYP.
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635,BY OTHERS, TYP.
15/16" HEAVY DUTY CLASS MAIN TEEPER ASTM C635, BY OTHERS, TYP.
NOTE:ATTACHMENT TO STRUCTUREDESIGNED AND PROVIDED BY OTHERS,NOT BY CERTAINTEED.
15/16" HEAVY DUTY CLASS MAIN TEEPER ASTM C635, BY OTHERS, TYP.
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
SUSPENSION SPECIFICATIONS
PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.2
SCALE: AS SHOWN
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
6" BEAM SPACING SHOWN,
ACTUAL CAN VARY, TYP.
TYPICAL SECTIONSSCALE: 3" = 1'-0"INTERIOR INSTALLATION
48" MAX MAIN TEE SPACING, TYP.
12" MAX BEAM OVERHANG, TYP.
2" X 6" TAVOLA PRIME BEAMSHOWN, ALL SIZES SIMILAR
15/16" CROSS TEE 48" O.C. MAXALONG MAIN TEE, TYP.
TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.
2" HANGER BRACKET/PIVOT ASSEMBLY
12 GA HANGER WIRE BY OTHERS,48" MAX ALONG MAIN TEE, TYP.
SLOPED OR CURVED (SHOWN) 15/16" HEAVY DUTYCLASS MAIN TEE PER ASTM C635, BY OTHERS, TYP.
12 GA HANGER WIRE 48" O.C. MAXALONG MAIN TEE, BY OTHERS, TYP.
15/16" CROSS TEE 48" O.C. MAX ALONGMAIN TEE, BY OTHERS, TYP.
2" HANGER BRACKET/PIVOT ASSEMBLY
MAIN TEE SPLICE &FASTENERS BYOTHERS, TYP.
INDEX MAIN TEE WITH FASTENERFROM BELOW, BY OTHERS, TYP.FASTENER WILL PREVENT PIVOTCLIP FROM SLIDING.
SLOPED OR CURVED 15/16"HEAVY DUTY CLASS MAINTEE PER ASTM C635, BYOTHERS, TYP.
INDEX MAIN TEE WITHFASTENER FROMBELOW, BY OTHERS,TYP. FASTENER WILLPREVENT PIVOT CLIPFROM SLIDING.
12" MAX MAIN TEE
OVERHANG, TYP.
48" MAX MAIN TEE SPACING, TYP.12 GA HANGER WIREBY OTHERS, TYP.
12" MAX BEAMOVERHANG, TYP.
2" X 6" TAVOLA PRIME BEAM SHOWN, ALL SIZES SIMILAR2" X 6" TAVOLA PRIMEEND CAP
TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.
2" HANGER BRACKET/PIVOT ASSEMBLY
INDEX MAIN TEE WITH FASTENERFROM BELOW, BY OTHERS, TYP.
6" BEAM SPACING SHOWN,ACTUAL CAN VARY, TYP.
12" MAX MAIN TEEOVERHANG, TYP.
TWO (2) MIN #6 FASTENERS PERBEAM/HANGER BRACKET, BYOTHERS, TYP.
2" X 6" TAVOLA PRIME BEAMSHOWN, ALL SIZES SIMILAR
11 16
" NO
M.,
VARI
ESAT
SLO
PED
CON
DITI
ON
S
NOTE:ATTACHMENT TO STRUCTUREDESIGNED AND PROVIDED BY OTHERS,NOT BY CERTAINTEED.
15/16" CROSS TEE 48" O.C. MAX ALONGMAIN TEE, BY OTHERS, TYP.
SLOPED OR CURVED 15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635, BY OTHERS, TYP.
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
SUSPENSION SPECIFICATIONS - SLOPED OR CURVED
PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.3
SCALE: AS SHOWN
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
1 LIFT HANGER BRACKET ASSEMBLY INTOPOSITION ON MAIN TEE AND SQUEEZE SCISSORCLIP ONTO MAIN TEE WEB.
2 FEED FIRST TAVOLA PRIME BEAM HALFWAYONTO HANGER BRACKET AND SECURE WITHTWO (2) MIN #6 FASTENERS (BY OTHERS).
3 REMOVE LINER FROM DOUBLE-SIDED ADHESIVEON BOTTOM SPLICE PLATE AND SECUREHALFWAY INTO FIRST TAVOLA PRIME BEAM.
FEED SECOND TAVOLA PRIME BEAM ONTOHANGER BRACKET ASSEMBLY AND BOTTOMPLATE. SECURE WITH TWO (2) MIN #6FASTENERS.
NON-SPLICE LOCATIONS: ONLY TWO (2)FASTENERS (1 PER SIDE) ARE REQUIRED ANDBOTTOM PLATE IS OMITTED.
4
1
1
HANGER BRACKETASSEMBLY
SCISSOR CLIP
3
2
4
2-PIECE TAVOLA PRIME BEAMSREQUIRE 2 BOTTOM SPLICEPLATES PER SPLICE CONDITION
CRITICAL: SCISSOR CLIP WILL NOT FUNCTIONPROPERLY IF INSTALLED AT A CROSS TEE.SHIFT CROSS TEE LOCATIONS AS NECESSARY.
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635
BOTTOM SPLICE PLATE WITHFACTORY-ATTACHEDDOUBLE-SIDED ADHESIVE
MIN #6 FASTENERSBY OTHERS, TYP.
*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR
TAVOLA PRIMEBEAM
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
HANGER BRACKET ASSEMBLY INSTALLATION
PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.4
SCALE: NOT TO SCALE
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR
2
3
4
BOTTOM SPLICE PLATE WITH FACTORY-ATTACHED DOUBLE-SIDED ADHESIVE
TWIST CLIP
SLOPED OR CURVED 15/16" HEAVY DUTYCLASS MAIN TEE PER ASTM C635
MIN #6 FASTENERSBY OTHERS, TYP.
5
6
1
HANGER BRACKET/PIVOT ASSEMBLY
2 INSERT HANGER BRACKET/PIVOT ASSEMBLYONTO MAIN TEE AND ROTATE TO ENGAGETWIST CLIP.
3 FEED FIRST TAVOLA PRIME BEAM HALFWAYONTO HANGER BRACKET AND SECURE WITHTWO (2) MIN #6 FASTENERS.
4 REMOVE LINER FROM DOUBLE-SIDED ADHESIVEON BOTTOM SPLICE PLATE AND SECUREHALFWAY INTO FIRST TAVOLA PRIME BEAM.
5 FEED SECOND TAVOLA PRIME BEAM ONTOHANGER BRACKET ASSEMBLY AND BOTTOMPLATE AND SECURE WITH TWO (2) MIN #6FASTENERS.
NON-SPLICE LOCATIONS: ONLY TWO (2)FASTENERS (1 PER SIDE) ARE REQUIRED ANDBOTTOM PLATE IS OMITTED.
1 AT SLOPED OR CURVED CONDITIONS, INDEXMAIN TEE WITH FASTENER FROM BELOW.
6 ENSURE TAVOLA BEAM IS PLUM AND TIGHTEN1/4"-20 NYLOCK NUT.
2-PIECE TAVOLA PRIME BEAMSREQUIRE 2 BOTTOM SPLICEPLATES PER SPLICE CONDITION
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
PIVOT CLIP INSTALLATION
PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.5
SCALE: NOT TO SCALE
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
1 INSERT END CAP ONTO BEAMEND AND ENSURE CAP INSERTGOES INSIDE OF BEAM
2 SECURE END CAP WITH TWO (2)MIN #6 FASTENERS
METAL END CAP
PAINTED, POWDER COATED, &DECORATED WOOD FINISHES
1
2
INTEGRAL METAL END CAP
PAINTED & POWDER COATED FINISHES
END CAP IS FACTORY-FORMED ANDFACTORY-POP-RIVETED
MAY BE LIMITED BY PROFILE SIZE ANDBEAM LENGTH
*2" X 6" BEAM SHOWN, ALL SIZES SIMILAR
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
END CAP SPECIFICATIONS
PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.6
SCALE: NOT TO SCALE
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
48" MAX, TYP.
12" MAX, TYP.
ACCESSIBLE TAVOLA PRIME BEAMSMUST HAVE MIN TWO (2) HANGERBRACKET ASSEMBLIES, TYP.
SQUEEZE SCISSOR CLIP TO RELEASE BEAMASSEMBLY FROM MAIN TEE (USECHANNEL LOCKS IF NEEDED)
FIELD CUT BEAMS TO CREATE ACCESS AREAS.USE END CAPS AT FIELD CUT ENDS ANDCREATE 1/2" GAP BETWEEN END CAPS.
ADD MAIN TEES AS REQUIREDTO SUPPORT FIELD CUT BEAMENDS, TYP.
*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR
15/16" CROSS TEE
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
PLENUM ACCESS
PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.7
SCALE: NOT TO SCALE
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR
TYPICAL ISOMETRICSCALE: NOT TO SCALE
47-1/16" CLEAR BETWEEN MAIN TEES (ABOVE BEAMS)
48" MAX MAIN TEE SPACING, TYP.
15/16" HEAVY DUTY CLASS MAINTEE PER ASTM C635*
4" CLEAR BASED ON 6" BEAMSPACING, ACTUAL CAN VARY, TYP.
TOP VIEWSCALE: NOT TO SCALE
4" C
LEAR
BAS
ED O
N6"
BEA
M S
PACI
NG,
ACTU
AL C
AN V
ARY,
TYP
.
'B'
'A'
SECTION 'A'SCALE: 3" = 1'-0"
SECTION 'B'SCALE: 3" = 1'-0"
4" CLEAR BASED ON 6" BEAM
SPACING, ACTUAL CAN VARY, TYP.
2" X 6" TAVOLAPRIME BEAM**
15/16" CROSS TEE 48" O.C. MAXALONG MAIN TEE, TYP.
3" X 48" FIXTURE SHOWN,ALL SIZES SIMILAR
LIGHT FIXTURE INDEPENDENTLY SUPPORTEDIN ACCORDANCE WITH LOCAL BUILDINGCODES & LIGHT FIXTURE MANUFACTURER'SINSTRUCTIONS
15/16" CROSS TEE 48" O.C.MAX ALONG MAIN TEE
3" X 48" FIXTURE SHOWN,ALL SIZES SIMILAR
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635
LIGHT FIXTURE INDEPENDENTLY SUPPORTEDIN ACCORDANCE WITH LOCAL BUILDINGCODES & LIGHT FIXTURE MANUFACTURER'SINSTRUCTIONS
3" X 48" FIXTURE SHOWN,ALL SIZES SIMILAR
2" X 6" TAVOLAPRIME BEAM**
47- 116" CLEAR BETWEEN MAIN TEES (ABOVE BEAMS)
48" MAX MAIN TEE SPACING, TYP.
2" X 6" TAVOLAPRIME BEAM**
48" MAX MAIN TEE SPACING, TYP.
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635
15/16" CROSS TEE 48" O.C.MAX ALONG MAIN TEE
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
TYPICAL FIXTURE
PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.8
SCALE: AS SHOWN
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR
48" MAX MAIN TEE SPACING, TYP.
15/16" CROSS TEE 48" O.C. MAXALONG MAIN TEE, TYP.
15/16" HEAVY DUTY CLASS MAINTEE PER ASTM C635*
ADD MAIN TEES (AND HANGER WIRE) AS REQUIREDTO MAINTAIN 12" MAX BEAM OVERHANG, TYP.
ADD END CAPS AT BEAMTERMINATIONS, TYP.
'A'
'B'
6" BEAM SPACING SHOWN,
ACTUAL CAN VARY, TYP.FIELD CUT BEAMS AT FIXTURE, TYP.
12" DIA. FIXTURE SHOWN, BYOTHERS, ALL SHAPES SIMILAR
ADD MAIN TEES (AND HANGER WIRE)AS REQUIRED TO MAINTAIN 12" MAXBEAM OVERHANG, TYP.
ADD END CAPS AT BEAMTERMINATIONS, TYP.
FIELD CUT BEAMS ATFIXTURE, TYP.
CONTINUOUS BEAM BEYOND
12" DIA. FIXTURE SHOWN, BYOTHERS, ALL SHAPES SIMILAR
LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN ACCORDANCEWITH LOCAL BUILDING CODES & LIGHT FIXTUREMANUFACTURER'S INSTRUCTIONS
12 GA HANGER WIREBY OTHERS, TYP.
12" DIA. FIXTURE SHOWN, BYOTHERS, ALL SHAPES SIMILAR
LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN ACCORDANCEWITH LOCAL BUILDING CODES & LIGHT FIXTUREMANUFACTURER'S INSTRUCTIONS
2" X 6" TAVOLA PRIMEEND CAP**
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635
2" X 6" TAVOLAPRIME BEAM**6" BEAM SPACING SHOWN,
ACTUAL CAN VARY, TYP.
2" X 6" TAVOLAPRIME BEAM**
48" MAX MAINTEE SPACING, TYP.12" MAX BEAM OVERHANG, TYP.
TYPICAL ISOMETRICSCALE: NOT TO SCALE
TOP VIEWSCALE: NOT TO SCALE
SECTION 'A'SCALE: 3" = 1'-0"
SECTION 'B'SCALE: 3" = 1'-0"
2" X 6" TAVOLAPRIME BEAM**
15/16" CROSS TEE 48" O.C.MAX ALONG MAIN TEE
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
FIELD CUT BEAM FOR TYPICAL FIXTURE
PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.9
SCALE: AS SHOWN
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
1 FEED TOP CORNER BRACKET ASSEMBLY INTOFACTORY-MITERED BEAM AND ALIGN POPRIVET HOLES
2 SECURE TOP CORNER BRACKET ASSEMBLYWITH FOUR (4) 1/8" POP RIVETS
3 USE DOUBLE-SIDED ADHESIVE TO SECUREBOTTOM CORNER BRACKET INTO BEAM
4 FEED SECOND BEAM INTO BRACKETS ANDSECURE WITH FOUR (4) 1/8" POP RIVETS
5 LIFT CORNER ASSEMBLY INTO POSITIONAND ON MAIN TEE AND SQUEEZE SCISSORCLIP ONTO MAIN TEE WEB.
VIEW FROM BELOWSCALE: NOT TO SCALE
90° S
HOW
N,
ACTU
AL C
AN V
ARY
6" BEAM SPACING SHOWN,
ACTUAL CAN VARY, TYP.
FACTORY-MITERED2" X 6" TAVOLABEAMS**
*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR
2
5
3
CORNER BRACKET INSTALLATION
EIGHT (8) 1/8" POP RIVETS REQUIREDAT TOP CORNER BRACKET, BYOTHERS, TYP.
TOP CORNER BRACKETASSEMBLY
BOTTOM CORNERBRACKET
4
1
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
CORNER CONDITIONS
PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.10
SCALE: NOT TO SCALE
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
LATERAL BRACING: BRACE WITH HANGER WIRES AND STRUTS PER ASTM E-580 AND IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS.
(4) #12 GAUGE WIRES SPLAYED 90° FROM EACH OTHER AT ANGLE NOT EXCEEDING 45° FROMPLANE OF CEILING. A STRUT FASTENED TO MAIN RUNNER SHALL BE EXTENDED TO ANDFASTENED TO STRUCTURE ABOVE. SPLAYED WIRE AND STRUT BRACING TO BE PLACED NOTMORE THAN 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 6 FEETFROM EACH WALL.
INTERIOR INSTALLATION
W
1/2" X 1-1/2" 16 GACRC BY OTHERS
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635
BAC CLIP SECURED WITH FOUR (4) #8X 1/2" HEX HEAD SELF-DRILLINGSCREWS, BY OTHERS
2" X 6" TAVOLA PRIME BEAMSHOWN, ALL SIZES SIMILAR
TYPICAL SECTION AT MAIN TEESCALE: FULL
SPLAYED 12 GA HANGERWIRE, BY OTHERS, TYP.
N 45°
45°
45°
E
45°
S
FOUR (4) #8 X 1/2" HEX HEADSELF-DRILLING SCREWS, BYOTHERS, TYP.
BAC CLIP
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635
1/2" X 1-1/2" 16 GA CRC BYOTHERS (HANGER WIREOMITTED FOR CLARITY)
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
SEISMIC SPECIFICATIONS
PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.11
SCALE: AS SHOWN
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.