12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

12
12" MAX MAIN TEE OVERHANG, TYP. 48" MAX MAIN TEE SPACING, TYP. 12" MAX BEAM OVERHANG, TYP. *SEE DETAIL A1.1 FOR AVAILABLE BEAM SIZES INTERIOR INSTALLATION 6" BEAM SPACING SHOWN, ACTUAL CAN VARY, TYP. BEAM SPECIFICATIONS SEE DETAIL A1.1 SUSPENSION SPECIFICATIONS SEE DETAIL A1.2 FIXTURE RECOMMENDATIONS SEE DETAILS A1.8 & A1.9 12 GA HANGER WIRE, BY OTHERS, NOT BY CERTAINTEED SEE DETAIL A1.2 48" MAX HANGER WIRE SPACING, TYP. HANGER BRACKET ASSEMBLY SEE DETAIL A1.4 PLENUM ACCESS SEE DETAIL A1.7 15/16" HEAVY DUTY CLASS MAIN TEE PER ASTM C635, BY OTHERS, TYP. 2" 6" TYPICAL SYSTEM SECTION SCALE: 3" = 1'-0" TWO (2) MIN #6 FASTENERS PER BEAM/ HANGER BRACKET, BY OTHERS, TYP. 2" HANGER BRACKET ASSEMBLY 2" X 6" TAVOLA PRIME BEAM* 15/16" HEAVY DUTY CLASS T-GRID PER ASTM C635 BY OTHERS SEE DETAIL A1.2 BEAM SPLICE SEE DETAIL A1.4 BEAM END CAP SEE DETAIL A1.6 5015 Oakbrook Parkway, Suite 100 Norcross, GA 30093 O 800 366 4327 F 770 806 0214 www.certainteed.com/architectural SPECIFICATIONS (unless noted otherwise) MATERIAL: .032" | .040" ALUMINUM FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED WOOD FINISH PERFORATION: NON-PERFORATED | #106 | #115 | #119 OVERALL ISOMETRIC VIEW PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.0 SCALE: AS SHOWN DRAWN BY: CTA ENGINEERING DATE: 6/1/21 These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Transcript of 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

Page 1: 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

12" MAX MAIN TEE

OVERHANG, TYP.

48" MAX MAIN TEE SPACING, TYP.

12" MAX BEAM OVERHANG, TYP.

*SEE DETAIL A1.1 FOR AVAILABLE BEAM SIZESINTERIOR INSTALLATION

6" BEAM SPACING SHOWN,

ACTUAL CAN VARY, TYP.

BEAM SPECIFICATIONSSEE DETAIL A1.1

SUSPENSION SPECIFICATIONSSEE DETAIL A1.2

FIXTURE RECOMMENDATIONSSEE DETAILS A1.8 & A1.9

12 GA HANGER WIRE, BY OTHERS,NOT BY CERTAINTEEDSEE DETAIL A1.2

48" MAX HANGER WIRE SPACING, TYP.

HANGER BRACKETASSEMBLYSEE DETAIL A1.4

PLENUM ACCESSSEE DETAIL A1.7

15/16" HEAVY DUTY CLASS MAIN TEEPER ASTM C635, BY OTHERS, TYP.

2"

6"

TYPICAL SYSTEM SECTIONSCALE: 3" = 1'-0"

TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.

2" HANGER BRACKETASSEMBLY

2" X 6" TAVOLAPRIME BEAM*

15/16" HEAVY DUTY CLASS T-GRIDPER ASTM C635 BY OTHERSSEE DETAIL A1.2

BEAM SPLICESEE DETAIL A1.4

BEAM END CAPSEE DETAIL A1.6

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

OVERALL ISOMETRIC VIEW

PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.0

SCALE: AS SHOWN

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 2: 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

BEAM SIZES

BEAM SIZES ARE DIMENSIONED WIDTH X HEIGHT

PROFILES ARE AVAILABLE IN 1/2" INCREMENTS, CONTACTCERTAINTEED FOR OTHER SIZES

MAX LENGTHS MAY BE PROFILE-SPECIFIC, CONTACT CERTAINTEED

BEAM LENGTHS AVAILABLE IN ±1/4" INCREMENTS, MINIMUMQUANTITIES MAY APPLY

BEAM MATERIAL

.032", .040" ALUMINUM

BEAM FINISHES

PAINTED & POWDER COATED

DECORATED WOOD FINISH (POWDER COATED)

LAMINATED WOOD FINISH (FILM)

PERFORATIONS

STANDARD PERFORATION BORDERS ARE 1/4" NOM.

PERFORATION106

% OPEN16.0%

115 12.0%119 8.0%

1" - 24" WIDTH

TAVOLAPRIME

2" -

6" H

EIGH

T

1", 112", 2" WIDTH

TAVOLATALL

15" M

AX H

EIGH

T

12'-0" MAX BEAM LENGTH

HEIG

HT

BEAM END & SIDE VIEWSCALE: NOT TO SCALE

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

BEAM SPECIFICATIONS

PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.1

SCALE: AS SHOWN

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 3: 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

TYPICAL SECTIONSSCALE: 3" = 1'-0"INTERIOR INSTALLATION

48" MAX MAIN TEE SPACING, TYP.

12" MAX BEAM OVERHANG, TYP.

48" MAX HANGER WIRE SPACING, TYP.

TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.

2" HANGER BRACKET ASSEMBLY

15/16" CROSS TEE 48" O.C. MAXALONG MAIN TEE, TYP.

2" X 6" TAVOLA PRIME BEAMSHOWN, ALL SIZES SIMILAR

TWO (2) MIN #6 FASTENERSPER BEAM/HANGERBRACKET, BY OTHERS, TYP.

12 GA HANGER WIRE BY OTHERS, TYP.

12" MAX MAIN TEE

OVERHANG, TYP.

12 GA HANGER WIRE BY OTHERS, TYP.

6" BEAM SPACING SHOWN,

ACTUAL CAN VARY, TYP.

2" X 6" TAVOLA PRIME BEAMSHOWN, ALL SIZES SIMILAR

15/16" CROSS TEE 48" O.C. MAX ALONGMAIN TEE, BY OTHERS, TYP.

TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.

2" HANGER BRACKET ASSEMBLY

48" MAX MAIN TEE SPACING, TYP.12 GA HANGER WIREBY OTHERS, TYP.

12" MAX BEAMOVERHANG, TYP.

2" X 6" TAVOLA PRIME BEAMSHOWN, ALL SIZES SIMILAR

2" X 6" TAVOLA PRIMEEND CAP

6" BEAM SPACING SHOWN,ACTUAL CAN VARY, TYP.

12" MAX MAIN TEEOVERHANG, TYP. 48" MAX HANGER WIRE SPACING, TYP.

2" HANGER BRACKETASSEMBLY

15/16" CROSS TEE 48" O.C.MAX ALONG MAIN TEE, BYOTHERS, TYP.

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635,BY OTHERS, TYP.

15/16" HEAVY DUTY CLASS MAIN TEEPER ASTM C635, BY OTHERS, TYP.

NOTE:ATTACHMENT TO STRUCTUREDESIGNED AND PROVIDED BY OTHERS,NOT BY CERTAINTEED.

15/16" HEAVY DUTY CLASS MAIN TEEPER ASTM C635, BY OTHERS, TYP.

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

SUSPENSION SPECIFICATIONS

PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.2

SCALE: AS SHOWN

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 4: 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

6" BEAM SPACING SHOWN,

ACTUAL CAN VARY, TYP.

TYPICAL SECTIONSSCALE: 3" = 1'-0"INTERIOR INSTALLATION

48" MAX MAIN TEE SPACING, TYP.

12" MAX BEAM OVERHANG, TYP.

2" X 6" TAVOLA PRIME BEAMSHOWN, ALL SIZES SIMILAR

15/16" CROSS TEE 48" O.C. MAXALONG MAIN TEE, TYP.

TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.

2" HANGER BRACKET/PIVOT ASSEMBLY

12 GA HANGER WIRE BY OTHERS,48" MAX ALONG MAIN TEE, TYP.

SLOPED OR CURVED (SHOWN) 15/16" HEAVY DUTYCLASS MAIN TEE PER ASTM C635, BY OTHERS, TYP.

12 GA HANGER WIRE 48" O.C. MAXALONG MAIN TEE, BY OTHERS, TYP.

15/16" CROSS TEE 48" O.C. MAX ALONGMAIN TEE, BY OTHERS, TYP.

2" HANGER BRACKET/PIVOT ASSEMBLY

MAIN TEE SPLICE &FASTENERS BYOTHERS, TYP.

INDEX MAIN TEE WITH FASTENERFROM BELOW, BY OTHERS, TYP.FASTENER WILL PREVENT PIVOTCLIP FROM SLIDING.

SLOPED OR CURVED 15/16"HEAVY DUTY CLASS MAINTEE PER ASTM C635, BYOTHERS, TYP.

INDEX MAIN TEE WITHFASTENER FROMBELOW, BY OTHERS,TYP. FASTENER WILLPREVENT PIVOT CLIPFROM SLIDING.

12" MAX MAIN TEE

OVERHANG, TYP.

48" MAX MAIN TEE SPACING, TYP.12 GA HANGER WIREBY OTHERS, TYP.

12" MAX BEAMOVERHANG, TYP.

2" X 6" TAVOLA PRIME BEAM SHOWN, ALL SIZES SIMILAR2" X 6" TAVOLA PRIMEEND CAP

TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.

2" HANGER BRACKET/PIVOT ASSEMBLY

INDEX MAIN TEE WITH FASTENERFROM BELOW, BY OTHERS, TYP.

6" BEAM SPACING SHOWN,ACTUAL CAN VARY, TYP.

12" MAX MAIN TEEOVERHANG, TYP.

TWO (2) MIN #6 FASTENERS PERBEAM/HANGER BRACKET, BYOTHERS, TYP.

2" X 6" TAVOLA PRIME BEAMSHOWN, ALL SIZES SIMILAR

11 16

" NO

M.,

VARI

ESAT

SLO

PED

CON

DITI

ON

S

NOTE:ATTACHMENT TO STRUCTUREDESIGNED AND PROVIDED BY OTHERS,NOT BY CERTAINTEED.

15/16" CROSS TEE 48" O.C. MAX ALONGMAIN TEE, BY OTHERS, TYP.

SLOPED OR CURVED 15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635, BY OTHERS, TYP.

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

SUSPENSION SPECIFICATIONS - SLOPED OR CURVED

PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.3

SCALE: AS SHOWN

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 5: 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

1 LIFT HANGER BRACKET ASSEMBLY INTOPOSITION ON MAIN TEE AND SQUEEZE SCISSORCLIP ONTO MAIN TEE WEB.

2 FEED FIRST TAVOLA PRIME BEAM HALFWAYONTO HANGER BRACKET AND SECURE WITHTWO (2) MIN #6 FASTENERS (BY OTHERS).

3 REMOVE LINER FROM DOUBLE-SIDED ADHESIVEON BOTTOM SPLICE PLATE AND SECUREHALFWAY INTO FIRST TAVOLA PRIME BEAM.

FEED SECOND TAVOLA PRIME BEAM ONTOHANGER BRACKET ASSEMBLY AND BOTTOMPLATE. SECURE WITH TWO (2) MIN #6FASTENERS.

NON-SPLICE LOCATIONS: ONLY TWO (2)FASTENERS (1 PER SIDE) ARE REQUIRED ANDBOTTOM PLATE IS OMITTED.

4

1

1

HANGER BRACKETASSEMBLY

SCISSOR CLIP

3

2

4

2-PIECE TAVOLA PRIME BEAMSREQUIRE 2 BOTTOM SPLICEPLATES PER SPLICE CONDITION

CRITICAL: SCISSOR CLIP WILL NOT FUNCTIONPROPERLY IF INSTALLED AT A CROSS TEE.SHIFT CROSS TEE LOCATIONS AS NECESSARY.

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635

BOTTOM SPLICE PLATE WITHFACTORY-ATTACHEDDOUBLE-SIDED ADHESIVE

MIN #6 FASTENERSBY OTHERS, TYP.

*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR

TAVOLA PRIMEBEAM

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

HANGER BRACKET ASSEMBLY INSTALLATION

PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.4

SCALE: NOT TO SCALE

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 6: 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR

2

3

4

BOTTOM SPLICE PLATE WITH FACTORY-ATTACHED DOUBLE-SIDED ADHESIVE

TWIST CLIP

SLOPED OR CURVED 15/16" HEAVY DUTYCLASS MAIN TEE PER ASTM C635

MIN #6 FASTENERSBY OTHERS, TYP.

5

6

1

HANGER BRACKET/PIVOT ASSEMBLY

2 INSERT HANGER BRACKET/PIVOT ASSEMBLYONTO MAIN TEE AND ROTATE TO ENGAGETWIST CLIP.

3 FEED FIRST TAVOLA PRIME BEAM HALFWAYONTO HANGER BRACKET AND SECURE WITHTWO (2) MIN #6 FASTENERS.

4 REMOVE LINER FROM DOUBLE-SIDED ADHESIVEON BOTTOM SPLICE PLATE AND SECUREHALFWAY INTO FIRST TAVOLA PRIME BEAM.

5 FEED SECOND TAVOLA PRIME BEAM ONTOHANGER BRACKET ASSEMBLY AND BOTTOMPLATE AND SECURE WITH TWO (2) MIN #6FASTENERS.

NON-SPLICE LOCATIONS: ONLY TWO (2)FASTENERS (1 PER SIDE) ARE REQUIRED ANDBOTTOM PLATE IS OMITTED.

1 AT SLOPED OR CURVED CONDITIONS, INDEXMAIN TEE WITH FASTENER FROM BELOW.

6 ENSURE TAVOLA BEAM IS PLUM AND TIGHTEN1/4"-20 NYLOCK NUT.

2-PIECE TAVOLA PRIME BEAMSREQUIRE 2 BOTTOM SPLICEPLATES PER SPLICE CONDITION

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

PIVOT CLIP INSTALLATION

PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.5

SCALE: NOT TO SCALE

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 7: 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

1 INSERT END CAP ONTO BEAMEND AND ENSURE CAP INSERTGOES INSIDE OF BEAM

2 SECURE END CAP WITH TWO (2)MIN #6 FASTENERS

METAL END CAP

PAINTED, POWDER COATED, &DECORATED WOOD FINISHES

1

2

INTEGRAL METAL END CAP

PAINTED & POWDER COATED FINISHES

END CAP IS FACTORY-FORMED ANDFACTORY-POP-RIVETED

MAY BE LIMITED BY PROFILE SIZE ANDBEAM LENGTH

*2" X 6" BEAM SHOWN, ALL SIZES SIMILAR

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

END CAP SPECIFICATIONS

PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.6

SCALE: NOT TO SCALE

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 8: 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

48" MAX, TYP.

12" MAX, TYP.

ACCESSIBLE TAVOLA PRIME BEAMSMUST HAVE MIN TWO (2) HANGERBRACKET ASSEMBLIES, TYP.

SQUEEZE SCISSOR CLIP TO RELEASE BEAMASSEMBLY FROM MAIN TEE (USECHANNEL LOCKS IF NEEDED)

FIELD CUT BEAMS TO CREATE ACCESS AREAS.USE END CAPS AT FIELD CUT ENDS ANDCREATE 1/2" GAP BETWEEN END CAPS.

ADD MAIN TEES AS REQUIREDTO SUPPORT FIELD CUT BEAMENDS, TYP.

*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR

15/16" CROSS TEE

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

PLENUM ACCESS

PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.7

SCALE: NOT TO SCALE

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 9: 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR

TYPICAL ISOMETRICSCALE: NOT TO SCALE

47-1/16" CLEAR BETWEEN MAIN TEES (ABOVE BEAMS)

48" MAX MAIN TEE SPACING, TYP.

15/16" HEAVY DUTY CLASS MAINTEE PER ASTM C635*

4" CLEAR BASED ON 6" BEAMSPACING, ACTUAL CAN VARY, TYP.

TOP VIEWSCALE: NOT TO SCALE

4" C

LEAR

BAS

ED O

N6"

BEA

M S

PACI

NG,

ACTU

AL C

AN V

ARY,

TYP

.

'B'

'A'

SECTION 'A'SCALE: 3" = 1'-0"

SECTION 'B'SCALE: 3" = 1'-0"

4" CLEAR BASED ON 6" BEAM

SPACING, ACTUAL CAN VARY, TYP.

2" X 6" TAVOLAPRIME BEAM**

15/16" CROSS TEE 48" O.C. MAXALONG MAIN TEE, TYP.

3" X 48" FIXTURE SHOWN,ALL SIZES SIMILAR

LIGHT FIXTURE INDEPENDENTLY SUPPORTEDIN ACCORDANCE WITH LOCAL BUILDINGCODES & LIGHT FIXTURE MANUFACTURER'SINSTRUCTIONS

15/16" CROSS TEE 48" O.C.MAX ALONG MAIN TEE

3" X 48" FIXTURE SHOWN,ALL SIZES SIMILAR

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635

LIGHT FIXTURE INDEPENDENTLY SUPPORTEDIN ACCORDANCE WITH LOCAL BUILDINGCODES & LIGHT FIXTURE MANUFACTURER'SINSTRUCTIONS

3" X 48" FIXTURE SHOWN,ALL SIZES SIMILAR

2" X 6" TAVOLAPRIME BEAM**

47- 116" CLEAR BETWEEN MAIN TEES (ABOVE BEAMS)

48" MAX MAIN TEE SPACING, TYP.

2" X 6" TAVOLAPRIME BEAM**

48" MAX MAIN TEE SPACING, TYP.

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635

15/16" CROSS TEE 48" O.C.MAX ALONG MAIN TEE

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

TYPICAL FIXTURE

PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.8

SCALE: AS SHOWN

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 10: 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR

48" MAX MAIN TEE SPACING, TYP.

15/16" CROSS TEE 48" O.C. MAXALONG MAIN TEE, TYP.

15/16" HEAVY DUTY CLASS MAINTEE PER ASTM C635*

ADD MAIN TEES (AND HANGER WIRE) AS REQUIREDTO MAINTAIN 12" MAX BEAM OVERHANG, TYP.

ADD END CAPS AT BEAMTERMINATIONS, TYP.

'A'

'B'

6" BEAM SPACING SHOWN,

ACTUAL CAN VARY, TYP.FIELD CUT BEAMS AT FIXTURE, TYP.

12" DIA. FIXTURE SHOWN, BYOTHERS, ALL SHAPES SIMILAR

ADD MAIN TEES (AND HANGER WIRE)AS REQUIRED TO MAINTAIN 12" MAXBEAM OVERHANG, TYP.

ADD END CAPS AT BEAMTERMINATIONS, TYP.

FIELD CUT BEAMS ATFIXTURE, TYP.

CONTINUOUS BEAM BEYOND

12" DIA. FIXTURE SHOWN, BYOTHERS, ALL SHAPES SIMILAR

LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN ACCORDANCEWITH LOCAL BUILDING CODES & LIGHT FIXTUREMANUFACTURER'S INSTRUCTIONS

12 GA HANGER WIREBY OTHERS, TYP.

12" DIA. FIXTURE SHOWN, BYOTHERS, ALL SHAPES SIMILAR

LIGHT FIXTURE INDEPENDENTLY SUPPORTED IN ACCORDANCEWITH LOCAL BUILDING CODES & LIGHT FIXTUREMANUFACTURER'S INSTRUCTIONS

2" X 6" TAVOLA PRIMEEND CAP**

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635

2" X 6" TAVOLAPRIME BEAM**6" BEAM SPACING SHOWN,

ACTUAL CAN VARY, TYP.

2" X 6" TAVOLAPRIME BEAM**

48" MAX MAINTEE SPACING, TYP.12" MAX BEAM OVERHANG, TYP.

TYPICAL ISOMETRICSCALE: NOT TO SCALE

TOP VIEWSCALE: NOT TO SCALE

SECTION 'A'SCALE: 3" = 1'-0"

SECTION 'B'SCALE: 3" = 1'-0"

2" X 6" TAVOLAPRIME BEAM**

15/16" CROSS TEE 48" O.C.MAX ALONG MAIN TEE

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

FIELD CUT BEAM FOR TYPICAL FIXTURE

PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.9

SCALE: AS SHOWN

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 11: 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

1 FEED TOP CORNER BRACKET ASSEMBLY INTOFACTORY-MITERED BEAM AND ALIGN POPRIVET HOLES

2 SECURE TOP CORNER BRACKET ASSEMBLYWITH FOUR (4) 1/8" POP RIVETS

3 USE DOUBLE-SIDED ADHESIVE TO SECUREBOTTOM CORNER BRACKET INTO BEAM

4 FEED SECOND BEAM INTO BRACKETS ANDSECURE WITH FOUR (4) 1/8" POP RIVETS

5 LIFT CORNER ASSEMBLY INTO POSITIONAND ON MAIN TEE AND SQUEEZE SCISSORCLIP ONTO MAIN TEE WEB.

VIEW FROM BELOWSCALE: NOT TO SCALE

90° S

HOW

N,

ACTU

AL C

AN V

ARY

6" BEAM SPACING SHOWN,

ACTUAL CAN VARY, TYP.

FACTORY-MITERED2" X 6" TAVOLABEAMS**

*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR

2

5

3

CORNER BRACKET INSTALLATION

EIGHT (8) 1/8" POP RIVETS REQUIREDAT TOP CORNER BRACKET, BYOTHERS, TYP.

TOP CORNER BRACKETASSEMBLY

BOTTOM CORNERBRACKET

4

1

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

CORNER CONDITIONS

PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.10

SCALE: NOT TO SCALE

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 12: 12 MAX MAIN TEE OVERHANG, TYP. 48 MAX HANGER WIRE …

LATERAL BRACING: BRACE WITH HANGER WIRES AND STRUTS PER ASTM E-580 AND IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS.

(4) #12 GAUGE WIRES SPLAYED 90° FROM EACH OTHER AT ANGLE NOT EXCEEDING 45° FROMPLANE OF CEILING. A STRUT FASTENED TO MAIN RUNNER SHALL BE EXTENDED TO ANDFASTENED TO STRUCTURE ABOVE. SPLAYED WIRE AND STRUT BRACING TO BE PLACED NOTMORE THAN 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 6 FEETFROM EACH WALL.

INTERIOR INSTALLATION

W

1/2" X 1-1/2" 16 GACRC BY OTHERS

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635

BAC CLIP SECURED WITH FOUR (4) #8X 1/2" HEX HEAD SELF-DRILLINGSCREWS, BY OTHERS

2" X 6" TAVOLA PRIME BEAMSHOWN, ALL SIZES SIMILAR

TYPICAL SECTION AT MAIN TEESCALE: FULL

SPLAYED 12 GA HANGERWIRE, BY OTHERS, TYP.

N 45°

45°

45°

E

45°

S

FOUR (4) #8 X 1/2" HEX HEADSELF-DRILLING SCREWS, BYOTHERS, TYP.

BAC CLIP

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635

1/2" X 1-1/2" 16 GA CRC BYOTHERS (HANGER WIREOMITTED FOR CLARITY)

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

SEISMIC SPECIFICATIONS

PROJECT: TAVOLA PRIME & TAVOLA TALL PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-PRIME&TAVOLA-TALL-A1.11

SCALE: AS SHOWN

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.