11c6661a374f23a5f703e9dd0b735372
-
Upload
leda-security-products-pty-ltd -
Category
Documents
-
view
215 -
download
1
description
Transcript of 11c6661a374f23a5f703e9dd0b735372
![Page 1: 11c6661a374f23a5f703e9dd0b735372](https://reader035.fdocuments.in/reader035/viewer/2022073121/568bd8c31a28ab2034a48ec6/html5/thumbnails/1.jpg)
✆ 1 3 0 0 7 8 0 4 5 0
Titan 300NB
Titan 200NBMaterial Steel – 200NB (219.1) x 4.8mm pipe Stainless Steel – 200NB (219.0) x 3.76mm pipeFinish Steel - Electrostatically powder coated or hot dipped galvanised Stainless steel – Linished or electro-polished
Material Steel – 300NB (323.9) x 6.4mm pipe Stainless Steel – 200NB (323.4) x 4.57mm pipeFinish Steel - Electrostatically powder coated or hot dipped galvanised Stainless steel – Linished or electro-polished
Supplied with galvanised pre-punched mounting plates to take 2, 4, 6 & 8 standard mounting enclosures.
Supplied with galvanised pre-punched mounting plates to take 2, 4, 6 & 8 standard mounting enclosures.
Double DoorSteel
TPB120BStainless Steel
STPB120B
1115
1115
Single doorSteel
TPB103BStainless Steel
STPB103B
electrical service
TypicalBaseplate
444
340
TypicalBaseplate
Single doorSteel
TPB30BStainless Steel
STPB30B
electrical servicewater service
Optional use as secure power & water service provideror water only
Wateraccess
Poweraccess
Poweraccess
Wateraccess
Double DoorSteel
TPB230BStainless Steel
STPB230B
TypicalSide View
TypicalSide View
275
385
24
540
275
385
24
540
Leda power bollards are designed for use with Clipsal 56 Series switch gear. Electrical installation must be carried out by a licensed electrical contractor to comply with SAA wiring rules (AS3000) and any additional requirements of statutory authorities.
www.ledasecur i ty.com.au128
I ndu s t r ia l R ange > Power D i s t r i bu t ion
![Page 2: 11c6661a374f23a5f703e9dd0b735372](https://reader035.fdocuments.in/reader035/viewer/2022073121/568bd8c31a28ab2034a48ec6/html5/thumbnails/2.jpg)
✆ 1 3 0 0 7 8 0 4 5 0
Titan 400Material 3mm mild steel sheet / 3mm Grade 304 stainless steel sheet
Finish Galvanised / electro polished
1115 820
400
200
1092
SteelTPB40B
Stainless SteelSTPB40B
400
Side ViewFront View
Titan 600Material 600NB (610) x 6.35mm steel pipe/ Grade 304 stainless steel pipe
Finish Galvanised / electro polished
1115
SteelTPB60B
Stainless SteelSTPB60B
30 gap for cables
Drainageholes
30 gap for hose
Wateraccess
Poweraccess
3°
550Opening
Side ViewFront View Rear View610
350Opening
820Electrical
200150
520Water
3 point security T-lock
Intro 2
Designer 8
Stainless 12
Aluminium 30
Timber 34
Pre-cast 38
Steel 46
Plastic 56
Lighting 60
Security 72
Designing 74
Impact Rating 78
Installation 80
Products 84
Retractable 108
HVM Bollards 110
VAC Bollards 118
Industrial 122
Bollards 124
Power 128
Card Readers 132
General 139
Accessories 142
Code Index 149
www.ledasecur i ty.com.au 129
I n du s t r i a lB o l l a r d s
Indu s t r ia l R ange > Power D i s t r i bu t ion
![Page 3: 11c6661a374f23a5f703e9dd0b735372](https://reader035.fdocuments.in/reader035/viewer/2022073121/568bd8c31a28ab2034a48ec6/html5/thumbnails/3.jpg)
✆ 1 3 0 0 7 8 0 4 5 0
Titan THB Series
Hinged
500
6751175
Designed for use with Clipsal 56 Series switch gear. Electrical installation must be carried out by a licensed electrical contractor to comply with SAA wiring rules (AS3000) and any additional requirements of statutory authorities.
Pavement Surface
Pavement Surface
Extra heavy dutycast iron lid
Load Class E400AS 3996
Semi automaticpower assist operation,
using a mechanical key
Extra heavy dutycast iron lid
Load Class E400AS 3996
Semi automaticpower assist operation,
using a mechanical key
Concreteinfill on lid
Concreteinfill on lid
Solidcast iron lid
THB800Top View
820
Side View
Side View
985
450
535
520
THB600Top View
THB600
THB800
700
480
Mounted flush with the ground,the lid hinges into a vertical position to allow access and connection to power, telecommunications, water and air.
Mounted flush with the ground,the lid hinges into a vertical position to allow access and connection to power, telecommunications, water and air.
www.ledasecur i ty.com.au130
I ndu s t r ia l R ange > Power D i s t r i bu t ion
![Page 4: 11c6661a374f23a5f703e9dd0b735372](https://reader035.fdocuments.in/reader035/viewer/2022073121/568bd8c31a28ab2034a48ec6/html5/thumbnails/4.jpg)
✆ 1 3 0 0 7 8 0 4 5 0
Titan TV Series
Vertical
940
600
940
600
1020
x
Pavement Surface
370
Front View Front View Front View
TV400Top View
TV300Top View
500
TV800Top View
500
370 440 500
Designed for use with Clipsal 56 Series switch gear. Electrical installation must be carried out by a licensed electrical contractor to comply with SAA wiring rules (AS3000) and any additional requirements of statutory authorities.
Cast iron lidLoad Class D250
AS 3996
Semi automaticpower assist operation,
using a mechanical key
Up to 4 outlets Up to 8 outletsUp to 3 outlets
Accommodatessingle or 3 phase power, telecommunications, water or air.
TV400TV300 TV800
Retracts flushto the pavement.
Intro 2
Designer 8
Stainless 12
Aluminium 30
Timber 34
Pre-cast 38
Steel 46
Plastic 56
Lighting 60
Security 72
Designing 74
Impact Rating 78
Installation 80
Products 84
Retractable 108
HVM Bollards 110
VAC Bollards 118
Industrial 122
Bollards 124
Power 128
Card Readers 132
General 139
Accessories 142
Code Index 149
www.ledasecur i ty.com.au 131
I n du s t r i a lB o l l a r d s
Indu s t r ia l R ange > Power D i s t r i bu t ion