Glazing Systems Compatible with 3M VHB Structural Glazing Tape
111 K Street, NE - LoopNetimages2.loopnet.com/d2/PHC2dVxE5t5tgeGSjN5MOB1FadwNCAqNpP-J7ZlIjHg/...•...
Transcript of 111 K Street, NE - LoopNetimages2.loopnet.com/d2/PHC2dVxE5t5tgeGSjN5MOB1FadwNCAqNpP-J7ZlIjHg/...•...
Building Features• 9-foot ceilings• A 3,000 square-foot conference center• Stunning Rooftop Terrace•Underground parking• Lobby attendant during business hours• Fitness center and showers•Designed to a LEED Platinum standard
Adam [email protected]
111KStreet,NEWashington,D.C.
FullFloorAvailabilities|5th,6thand11thFloors8,980SFEach
LEASING OPPORTUNITIES: 202.513.6700
GROU
ND F
LOOR
LOB
BY/R
ETAI
L
K STRE ET
LOADING DOCK
PARKING RAMP
LOBBY
RETAIL
RETAIL
FIRS
T ST
REET
PARK
ING
LEVE
L 2
K STRE ET
FIRS
T ST
REET
TYPI
CAL
FLOO
R PL
AN
K STRE ET
FIRS
T ST
REET
TEST
FIT
No
1 TY
PICA
L FL
OOR
PLAN
K STRE ET
FIRS
T ST
REET
TEST
FIT
No
2 TY
PICA
L FL
OOR
PLAN
K STRE ET
FIRS
T ST
REET
BUILDING SIZETOTAL AREA:
90,000 gross square feetNUMBER OF FLOORS:
11TYPICAL FLOOR PLATE:
8,980 rentable square feet BUILDING STRUCTURESTRUCTURAL SYSTEM:
Cast-in-place reinforced concreteSTRUCTURAL CAPACITY:
80 lbs/sf live load, 20 lbs/sf dead loadCOLUMN SPACING:
30'TYPICAL SLAB TO SLAB:
11'-4"
FINISHED CEILING HEIGHTTYPICAL FLOORS:
9'-0"MAIN LOBBY: 24'-0"
ELEVATORSNUMBER: Two passenger, one of which may be used as a “swing” service cab
Both elevators serve the parking garageCAPACITY: 3,500 lbs.SPEED: 350 feet per minute
PARKINGLEVELS: 2SPACES: 44
SECURITYACCESS SYSTEM:
Perimeter and Elevator key-card access controlON-SITE PERSONNEL:
Security Guard/Concierge during business hours
LIFE SAFETY SYSTEMSSPRINKLER SYSTEM:
Fully sprinklered buildingFIRE ALARM SYSTEM:
ADA compliant building fire detection and alarm system and public address system, UL-approved addressable fire management/alarm system compliant with all applicable code requirements
AMENITIES • Ground-floor Retail • Conference Center at second floor • Rooftop Terrace with dramatic 270 degree views, including to the U.S. Capitol Building • Near the New York Avenue Red Line MetroRail station, adjacent to Union Station which is served by the Metro Red Line, Amtrak and MARC & VRE commuter rail lines, and located on the Metropolitan Branch Bicycle Trail • Bicycle storage and locker / shower facilities for cyclists and runners • Fitness facility
GREEN FEATURES • Curtainwall all around allows unrestricted access to daylight and views • Location near public and alternative transportation routes • Bicycle commuter facilities provided • Storm water management plan, including a green roof, to reduce runoff • Water conserving plumbing fixtures to reduce water usage • Efficient mechanical equipment, high performance curtainwall and building systems management to reduce energy consumption • A portion of electricity may be purchased from “green” sources • Many building materials will have high recycled content and will be sourced locally
EXTERIOR MATERIALS • Clear low-E insulated glazing in custom aluminum curtainwall, with sound attenuation provided at the east façade on floors 3, 4 & 5 • Painted architectural metal panels
INTERIOR MATERIALSMAIN LOBBY:
• Floor – Honed Marble • Walls – Double-height wood feature wall, lacquered panels, etched patterned glass, stone base and stainless steel reveals & accents • Doors – Ultra narrow stile stainless steel with clear glazing • Ceiling – Large luminescent panels with down lights in stainless steel accent strips, accent and wall-wash lights in soffitsMAIN ELEVATOR LOBBY:
• Floor – Honed Marble • Walls – Back-painted glass, lacquered panels, stone base and stainless steel reveals & accents • Ceiling – floating gypsum board ceiling plane with accent down lights and cove wall-wash lighting
PROJECT TEAMDEVELOPER: J Street DevelopmentARCHITECT:
GenslerSTRUCTURAL ENGINEER:
KCEMEP ENGINEER:
TOLK
BU
ILD
ING
SP
ECIF
ICA
TIO
NS