1102340000_CAT4-5_C_EN

58
C PLC Interfaces H-, R- and S-System C.1 Contents PLC Interfaces H-, R- and S-System Universal precabling for PLCs C.2 Selection guide C.5 Direct inputs/outputs for digital cards C.20 Opto-decoupled inputs for digital cards C.38 Relay outputs for digital cards C.42 Input / output for analogue cards C.54 PLC Interfaces

description

Input / output for analogue cards C.54 Direct inputs/outputs for digital cards C.20 Opto-decoupled inputs for digital cards C.38 C PLC Interfaces H-, R- and S-System Contents PLC Interfaces C.1

Transcript of 1102340000_CAT4-5_C_EN

Page 1: 1102340000_CAT4-5_C_EN

C

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C.1

Contents

PLC Interfaces

H-, R- and S-System

Universal precabling for PLCs C.2

Selection guide C.5

Direct inputs/outputs for digital cards C.20

Opto-decoupled inputs for digital cards C.38

Relay outputs for digital cards C.42

Input / output for analogue cards C.54

PLC Interfaces

Page 2: 1102340000_CAT4-5_C_EN

C

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C.2

The complexity of machines and installa-tions in industry, processing or building isgiving rise to ever-increasing cablingcosts. The traditional wire to wire cablingbetween the PLC and the inputs/outputsis very expensive during installation andcommissioning. The PLC interface systemoffers the user an easy and quick-to-installsolution for wiring the inputs and outputsof the SIEMENS SIMATIC® S7.

Special front adapters replace the usualscrewed connectors used for the I/Ocards of the PLC. The signals from thePLC are sent to the active or passivecomponents by means of a prefabricatedlead fitted with a 20-pole female connec-tor.

Wire to wire cabling

Most PLC I/O cards use two types ofconnection:

• screw,

• tension clamp.

In each case, the signals are connectedindividually to each connection compo-nent.

Disadvantages of wire to wire cabling:

• high assembly costs,

• risk of error increasing with the numberof wires connected,

• large amount of space taken up in the cabinet,

• high installation costs,

• a lot of time taken up in preparing andlaying the wires,

• a large amount of time taken up in pro-ducing wiring diagrams and drawings.

Wiring interface system

The basic idea is that the PLC’s I/O cardsare connected to the active or passive I/Omodules using prefabricated cables. Frontadapters are directly plugged into thePLC’s I/O cards. The adapter internallyconverts the PLC-specific connectors to an HE connector for ribbon cable (in accor-dance with IEC 603-1/ DIN 41651). The active or passive I/O modules can thus beused independently of the type of PLC.

The wiring interface system has the follo-wing advantages over wire to wire cabling:

• minimum wiring costs,

• reduced installation time,

• the commissioning and the productionof wiring drawings is simplified.

The family of PLC interface modules al-lows the inputs/outputs for main PLC manufacturers to be quickly and easilyconnected.

PLC interface systems

PLC

PLC

Universal precabling for PLCs

Page 3: 1102340000_CAT4-5_C_EN

C

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C.3

Advantages of the system:

• Quick

– reduced design times,

– time saved during installation,

– reduced commissioning and trouble-shooting times,

– reduced on-site wiring times thanks tothe prefabricated cables.

• Reliable

– no wiring errors,

– clear wiring in the cabinet (cable systeminstead of individual wires),

– labelling corresponding to that of thePLC,

– additional individual labelling.

• Flexible

– many input/output modules (about 40possibilities),

– variable cable lengths,

– modularity of all components,

– configuration of 1 x 4 bytes and 2 x 2bytes without distributor,

– option to mix functions by byte at theI/Os,

– extensions possible without any problem,

– flexibility thanks to the ease in exchanging input/output interfaces.

• Takes up only a small amount ofspace

– more space in the cable ducts,

– narrow modules,

– no terminal block.

PLC interface systems

Inp

uts

Out

put

s

Universal precabling for PLCs

Input:1x1 Byte8 Signals

Input :1x1 Byte8 Signals

Input :1x1 Byte8 Signals

Input :1x1 Byte8 Signals

Output:1x1 Byte8 Signals

Output:1x1 Byte8 Signals

Output:1x1 Byte8 Signals

Output:1x1 Byte8 Signals

Page 4: 1102340000_CAT4-5_C_EN

C.4

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

Relay outputs – System H

Direct inputs – System R

Thanks to its industrial connector, system R enables the connection of input

signals to a higher voltage of up to 160 V or 250 V.

It is characterised by:

� connector type RSV 1.6 (250 V DC 8 A)

� precabling to PLC – 0.25 mm2 (LIYY)

� input/output interface module boards for digital signals 8, 16, 32-channel

System H ...

… screw or tension clamp, standard or compact

Weidmüller universal precabling for PLCs

Weidmüller’s system H was developed for all PLC types and can be adapted

to suit all situations. Particularly economic, it is characterised by:

� Connector type HE, 10/20 pins, fully protected:extruded-insulation cable, polarised, secure connection

� precabling to PLC – 0.25 mm2 (LIYY)

� connection type selection: screw or tension clamp

� new compact modules, reducing the size of the cabinet

� Input/output of interface modules boards for digital signals: 4, 8, 12, 16 and 32-channel

Universal precabling for PLCs

System R …

… with the RSV 1.6 industrial connector

Analog input/outputs – System S

The sub-d metallic housing is ideal for the transmission of analogue signals:

� Connector sub-d female 15, 25, 37 poles

� Precabling to PLC – 0.25 mm2 shielded (LYC)

� Input/output interface module boards with PE.

System S …

… with shielded Sub-D connector

C

Page 5: 1102340000_CAT4-5_C_EN

C.5

C

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

* The suffix xxx in the order number shows the length of the cable in dm. the standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 4.00 m (040) - 5.00 m (050).

Note: it is also possible to use the catalogue type of the cable.

In this case the suffix xxxx of the catalogue type shows the length of the cable in cm. The standard lengths are: 1.00 m (0100) – 1.50 m (0150) – 2.00 m (0200) - 3.00 m (0300) – 4.00 m (0400) – 5.00 m (0500)

�PLC Siemens - S7-300

6ES7 321-1BH01 / 1BH81-0AA0

6ES7 321-1BL00 / 1BL80-0AA0

6ES7 321-1BP00-0AA0

6ES7 321-1EH01-0AA0

6ES7 321-1BH50-0AA0

6ES7 321-7BH00 / 7BH80-0AB0

6ES7 321-1FF01 / 1FF81-0AA0

6ES7 321-1EL00-0AA0

6ES7 321-1CH80-0AA0

6ES7 321-7RD00-0AB0

6ES7 322-1BH01 / 1BH81-0AA0

6ES7 322-1BL00-0AA0

6ES7 322-1BP00-0AA0

6ES7 321-1BP50-0AA0

6ES7 322-1EH01-0AA0

6ES7 322-1BF01-0AA0

6ES7 322-1FF01 / 1FF81-0AA0

6ES7 322-1HF01-0AA0

6ES7 322-8BF00-0AB0

6ES7 322-1HH00-0AA0

6ES7 322-1EL00-0AA0

6ES7 322-1HF10 / 1HF80-0AA0

6ES7 322-1CF80-0AA0

6ES7 322-5SD00-0AB0

6ES7 322-5RD00-0AB0

6ES7 323-1BH00 / 1BH80-0AA0

6ES7 323-1BL00-0AA0

6ES7 312-5BD00-0AB0 (312C)

6ES7 313-6CE00-0AB0 (313C-2DP)

6ES7 313-6BE00-0AB0 (313C-2PtP)

6ES7 313-5BE00-0AB0 (313C)

6ES7 314-6CF00-0AB0 (314C-2DP)

6ES7 314-6BF00-0AB0 (314C-2PtP)

6ES7 331-7KF01-0AB0

6ES7 331-7NF00-0AB0

6ES7 331-7RD00-0AB0

6ES7 331-7RD00-0AB0

6ES7 331-7SF00-0AB0

6ES7 331-7PF00-0AB0

6ES7 331-7KB01 / 7KB81-0AB0

6ES7 332-5HD01-0AB0

6ES7 332-5HD01-0AB0

6ES7 332-5HB01 / 5HB81-0AB0

6ES7 332-5HB01 / 5HB81-0AB0

6ES7 332-7ND00-0AB0

6ES7 332-7ND00-0AB0

6ES7 332-5RD00-0AB0

6ES7 332-5HF00-0AB0

6ES7 334-0KE00-0AB0

6ES7 335-7HG01-0AB0

6ES7 334-0CE01-0AA0

7789234xxx

7789236xxx

7789247XXX

7789212xxx

7789234xxx

7789210xxx

7789219xxx

7789215xxx

7789211xxx

7789234xxx

7789234xxx

7789236xxx

7789246XXX

7789246XXX

7789211xxx

7789239xxx

7789219xxx

7789220xxx

7789239xxx

7789214xxx

7789211xxx

7789190xxx

7789191xxx

7789192xxx

7789192xxx

7789237xxx

7789236xxx

7789221xxx

7789222xxx

7789222xxx

7789222xxx

7789223xxx

7789222xxx

7789223xxx

7789222xxx

7789223xxx

7789229xxx

7789231xxx

7789193xxx

7789194xxx

7789229xxx

7789230xxx

7789224xxx

7789228xxx

7789227xxx

7789228xxx

7789227xxx

7789228xxx

7789227xxx

7789195xxx

7789233xxx

7789196xxx

7789226xxx

7789225xxx

7789293xxx

7789293xxx

7789293xxx

7789293xxx

7789293xxx

7789293xxx

1

1

2

1

1

1

1

1

1

1

1

1

2

2

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

1

1

2

2

16-channel - H B)

32-channel - H A, B)

32-channel - H A, B)

16-channel - R

16-channel - H

16-channel - R

8-channel - R

32-channel - R

16-channel - R

16-channel - H

16-channel - R

8-channel - R

16-channel - R D)

16-channel - R

16-channel - R

16-channel - R D)

8-channel - R

8-channel - H

8-channel - H

8-channel - H

16-channel - H

12-channel - H E)

16-channel - H

16-channel - H

16-channel - H

8-channel - H

16-channel - H

8-channel - H

16-channel - H

8-channel - H

1

1

1

1

1

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

16-channel B)

16-channel B)

)

16-channel

1

2

2

1

16-channel C)

32-channel A, C)

32-channel A, C)

32-channel A, C)

8-channel

8-channel

8-channel

16-channel

8-channel E)

16-channel

16-channel

16-channel

16-channel

16-channel

1

1

1

1

1

1

1

1

1

1

1

1

8-channel P

8-channel P

8-channel P

8-channel

16-channel

4-channel

4-channel

8-channel

8-channel

4-channel

4-channel

4-channel

4-channel

4-channel

4-channel

4-channel

4-channel

8-channel

8-channel

16-channel

16-channel

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Selection guide

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example: Cable 2 metres in length: Order number: 7789236020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

E) Two channels unused

* All I/O signals with same common.

* Addional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

Manufacturer order number Type Type Type TypeOrder No. Order No.

I/O cards

PLC Cables Interfaces

Standard SITOP ConnectionDigital Direct

I/Os

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty QtyQty

Dig

ital

inp

utD

igit

al o

utp

utA

nal.

Inp

utA

nal.

Out

put

Dig

ital

I/O

Ana

l.I/

OD

igit

al a

ndA

nal.

I/O

C.6

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

V L 9445530000 RS 8ES-D-L H/V C.21

V 9441540000 (*) RS8ES-DP RSV1,6/V C.21

V L 9445630000 RS 12ES-D-L H/V C.22

C V 9445700000 RS 16ES H/V C.23

C V L 9445710000 RS 16ES-L H/V C.23

Z 9447700000 (*) RS 16ES H/Z C.23

Z L 9447710000 RS 16ES-L H/Z C.23

V L I 9445810000 RS 16ES-S-I-L H/V C.23

C V 9445720000 RS 16ES-D H/V C.24

C V L 9445730000 RS 16ES-D-L H/V C.24

Z L 9447730000 RS 16ES-D-L H/Z C.24

C V L I 9445750000 RS 16ES-D-I-L H/V C.24

Z L I 9447750000 (*) RS 16ES-D-I-L H/Z C.24

V F 9445820000 RS 16ES-D-F H/V C.25

C V 9445760000 RS 16ES-T H/V C.25

C V L 9445770000 RS 16ES-T-L H/V C.25

Z L 9447770000 RS 16ES-T-L H/Z C.25

V 9441500000 RS16ES RSV1,6/V C.26

V I 9441860000 RS16ES-I RSV1,6/V C.26

V 9441700000 RS16ES-DP RSV1,6/V C.27

V F 9441560000 RS16ES-DP/F RSV1,6/V C.27

V I 9441600000 (*) RS16E-3E/I RSV1,6/V C.28

C V 9445900000 RS 32ES H/V C.29

C V L 9445910000 RS 32ES-L H/V C.29

Z 9447900000 (*) RS 32ES H/Z C.29

Z L 9447910000 RS 32ES-L H/Z C.29

V L I 9445870000 RS 32ES-S-I-L H/V C.30

C V L 9445930000 RS 32ES-D-L H/V C.31

Z L 9447930000 RS 32ES-D-L H/Z C.31

C V L I 9445950000 RS 32ES-D-I-L H/V C.32

Z L I 9447950000 (*) RS 32ES-D-I-L H/Z C.32

V F 9445980000 RS 32ES-D-F H/V C.33

C V 9445960000 RS 32ES-T H/V C.34

C V L 9445970000 RS 32ES-T-L H/V C.34

Z L 9447970000 RS 32ES-T-L H/Z C.34

V 9441510000 RS32ES RSV1,6/V C.35

V I 9441870000 RS32ES-I RSV1,6/V C.35

V 9441710000 RS32ES-DP RSV1,6/V C.36

V F 9441570000 (*) RS32ES-DP/F RSV1,6/V C.36

V I 9441610000 RS32E-3E/I RSV1,6/V C.37

Note: Preferably articles in bold (*) under demand

No. of channels

Type of wiring

1 LED per chan.

Discon-nectable

FuseCompact version

Connection

Screw Tension c.

H or R System

Type

Order No. PageType

Functionalities Modules

8chan-nels

H System

H System

2-wire

1-wire

1-wire

2-wire

2-wire

3-wire

3-wire

2-wire

2-wire

H System

1-wire

3-wire

2-wire

H System

R System

R System

1-wire

2-wire

3-wire

R System

12chan.

16chan-nels

32chan-nels

Module overview - Direct inputs/outputs for digital cards

C.20

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Select the PLC card from the correspon-ding table

Example:• PLC: Siemens S7-300• Card: 6ES7 321-1BL00 / 1BL80-0AA0

Look up the order number for the cable and the quantity to be ordered

Example:• Cable order number 7789236xxx* - Qty 1* see the note at the bottom of the page

Refer to the page whose number isgiven at the top of the column

Example:• Please refer to page C.20 Direct inputs/outputs

for digital cards

Select the module order number in the family defined at stage 3

Example:• Module order number 944595 – Qty. 1

32-channel module, 2-wire cabling, compact, version with Led, interruptible

• Technical characteristics, page C.32

PLC Siemens - S7-300

6ES7 321-1BH01 / 1BH81-0AA0

6ES7 321-1BL00 / 1BL80-0AA0

6ES7 321-1BP00-0AA0

6ES7 321-1EH01-0AA0

6ES7 321-1BH50-0AA0

6ES7 321-7BH00 / 7BH80-0AB0

7789234xxx

7789236xxx

7789247XXX

7789212xxx

7789234xxx

7789210xxx

7789293xxx

7789293xxx

7789293xxx

1

1

2

1

1

1

1

2

1

16-channel - H B)

32-channel - H A, B)

32-channel - H A, B)

16-channel - R

16-channel - H

16-channel - R

1

1

1

1

1

16-channel B)

16-channel B)

)

1

2

2

Manufacturer order number Type TypeOrder No. Order No.

I/O cards

PLC Cables Interfaces

Standard SITOP ConnectionDigital Direct

I/Os

- see page C.20 - - see page C.38 - - se

Digital opto-decoupled input

D

Qty Qty QtyQty

ital

inp

ut

H-,

R-

and

S-S

yste

m

V F 9441560000 RS16ES-DP/F RSV1,6/V C.27

V I 9441600000 (*) RS16E-3E/I RSV1,6/V C.28

C V 9445900000 RS 32ES H/V C.29

C V L 9445910000 RS 32ES-L H/V C.29

Z 9447900000 (*) RS 32ES H/Z C.29

Z L 9447910000 RS 32ES-L H/Z C.29

V L I 9445870000 RS 32ES-S-I-L H/V C.30

C V L 9445930000 RS 32ES-D-L H/V C.31

Z L 9447930000 RS 32ES-D-L H/Z C.31

C V L I 9445950000 RS 32ES-D-I-L H/V C.32

Z L I 9447950000 (*) RS 32ES-D-I-L H/Z C.32

V F 9445980000 RS 32ES-D-F H/V C.33

C V 9445960000 RS 32ES-T H/V C.34

C V L 9445970000 RS 32ES-T-L H/V C.34

Z L 9447970000 RS 32ES-T-L H/Z C.34

V 9441510000 RS32ES RSV1,6/V C.35

V I 9441870000 RS32ES-I RSV1,6/V C.35

V 9441710000 RS32ES-DP RSV1 6/V C 36

3-wire

1-wire

3-wire

2-wire

H System

1-wire

32chan-nels

Using the selection guide

Selection guide

Look up the exact module family and the quantity to be ordered

Example:• 32-channel system H - Qty. 1

or• 16-channel opto-decoupled system H - Qty. 2

Page 6: 1102340000_CAT4-5_C_EN

PLC Siemens - S7-300

6ES7 321-1BH01 / 1BH81-0AA0

6ES7 321-1BL00 / 1BL80-0AA0

6ES7 321-1BP00-0AA0

6ES7 321-1EH01-0AA0

6ES7 321-1BH50-0AA0

6ES7 321-7BH00 / 7BH80-0AB0

6ES7 321-1FF01 / 1FF81-0AA0

6ES7 321-1EL00-0AA0

6ES7 321-1CH80-0AA0

6ES7 321-7RD00-0AB0

6ES7 322-1BH01 / 1BH81-0AA0

6ES7 322-1BL00-0AA0

6ES7 322-1BP00-0AA0

6ES7 321-1BP50-0AA0

6ES7 322-1EH01-0AA0

6ES7 322-1BF01-0AA0

6ES7 322-1FF01 / 1FF81-0AA0

6ES7 322-1HF01-0AA0

6ES7 322-8BF00-0AB0

6ES7 322-1HH00-0AA0

6ES7 322-1EL00-0AA0

6ES7 322-1HF10 / 1HF80-0AA0

6ES7 322-1CF80-0AA0

6ES7 322-5SD00-0AB0

6ES7 322-5RD00-0AB0

6ES7 323-1BH00 / 1BH80-0AA0

6ES7 323-1BL00-0AA0

6ES7 312-5BD00-0AB0 (312C)

6ES7 313-6CE00-0AB0 (313C-2DP)

6ES7 313-6BE00-0AB0 (313C-2PtP)

6ES7 313-5BE00-0AB0 (313C)

6ES7 314-6CF00-0AB0 (314C-2DP)

6ES7 314-6BF00-0AB0 (314C-2PtP)

6ES7 331-7KF01 / 7KF02-0AB0

6ES7 331-7NF00-0AB0

6ES7 331-7RD00-0AB0

6ES7 331-7RD00-0AB0

6ES7 331-7SF00-0AB0

6ES7 331-7PF00-0AB0

6ES7 331-7KB01 / 7KB81-0AB0

6ES7 332-5HD01-0AB0

6ES7 332-5HD01-0AB0

6ES7 332-5HB01 / 5HB81-0AB0

6ES7 332-5HB01 / 5HB81-0AB0

6ES7 332-7ND00-0AB0

6ES7 332-7ND00-0AB0

6ES7 332-5RD00-0AB0

6ES7 332-5HF00-0AB0

6ES7 334-0KE00-0AB0

6ES7 335-7HG01-0AB0

6ES7 334-0CE01-0AA0

7789234xxx

7789236xxx

7789247xxx

7789212xxx

7789234xxx

7789210xxx

7789219xxx

7789215xxx

7789211xxx

7789234xxx

7789234xxx

7789236xxx

7789246xxx

7789246xxx

7789211xxx

7789239xxx

7789219xxx

7789220xxx

7789239xxx

7789214xxx

7789211xxx

7789190xxx

7789191xxx

7789192xxx

7789192xxx

7789237xxx

7789236xxx

7789221xxx

7789222xxx

7789222xxx

7789222xxx

7789223xxx

7789222xxx

7789223xxx

7789222xxx

7789223xxx

7789229xxx

7789231xxx

7789193xxx

7789194xxx

7789229xxx

7789230xxx

7789224xxx

7789228xxx

7789227xxx

7789228xxx

7789227xxx

7789228xxx

7789227xxx

7789195xxx

7789233xxx

7789196xxx

7789226xxx

7789225xxx

7789293xxx

7789293xxx

7789293xxx

7789293xxx

7789293xxx

7789293xxx

1

1

2

1

1

1

1

1

1

1

1

1

2

2

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

1

1

2

2

16-channel - H B)

32-channel - H A, B)

32-channel - H A, B)

16-channel - R

16-channel - H

16-channel - R

8-channel - R

32-channel - R

16-channel - R

16-channel - H

16-channel - R

8-channel - R

16-channel - R D)

16-channel - R

16-channel - R

16-channel - R D)

8-channel - R

8-channel - H

8-channel - H

8-channel - H

16-channel - H

12-channel - H E)

16-channel - H

16-channel - H

16-channel - H

8-channel - H

16-channel - H

8-channel - H

16-channel - H

8-channel - H

1

1

2

1

1

1

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

16-channel B)

16-channel B)

)

16-channel

1

2

1

16-channel C)

32-channel A, C)

32-channel A, C)

32-channel A, C)

8-channel

8-channel

8-channel

16-channel

8-channel E)

16-channel

16-channel

16-channel

16-channel

16-channel

1

1

1

1

1

1

1

1

1

1

1

1

8-channel P

8-channel P

8-channel P

8-channel

16-channel

4-channel

4-channel

8-channel

8-channel

4-channel

4-channel

4-channel

4-channel

4-channel

4-channel

4-channel

4-channel

8-channel

8-channel

16-channel

16-channel

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Selection guide

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example: Cable 2 metres in length: Order number: 7789236020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

E) Two channels unused

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

Manufacturer order number Type Type Type TypeOrder No. Order No.

I/O cards

PLC Cables Interfaces

Standard SITOP ConnectionDigital Direct

I/Os

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty QtyQty

Dig

ital

inp

utD

igit

al o

utp

utA

nal.

Inp

utA

nal.

Out

put

Dig

ital

I/O

Ana

l.I/

OD

igit

al a

ndA

nal.

I/O

C.6

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 7: 1102340000_CAT4-5_C_EN

1

1

1

1

1

1

1

7789292xxx

7789278xxx

7789273xxx

7789278xxx

7789290xxx

7789273xxx

7789291xxx

7789292xxx

7789283xxx

7789273xxx

7789270xxx

7789291xxx

7789292xxx

7789287xxx

7789286xxx

7789285xxx

7789285xxx

7789284xxx

7789284xxx

7789288xxx

7789293xxx

7789293xxx

PLC Siemens - S7-400

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789292020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

6ES7 421-1BL00-0AA0

6ES7 421-1EL00-0AA0

6ES7 421-1FH00-0AA0

6ES7 421-7DH00-0AB0

6ES7 421-7BH00-0AB0

6ES7 421-1FH20-0AA0

6ES7 422-1BH10-0AA0

6ES7 422-1BL00-0AA0

6ES7 422-1FF00-0AA0

6ES7 422-1FH00-0AA0

6ES7 422-1HH00-0AA0

6ES7 422-5EH10-0AB0

6ES7 422-7BL00-0AB0

6ES7 431-1KF00-0AB0

6ES7 431-1KF00-0AB0

6ES7 431-1KF10-0AB0

6ES7 431-1KF20-0AB0

6ES7 431-7QH00-0AB0

6ES7 431-0HH00-0AB0

6ES7 432-1HF00-0AB0

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

32-channel - H A, B)

32-channel - R

16-channel - R D)

32-channel - R

16-channel - H

16-channel - R

8-channel - R

16-channel - R

32-channel - R

1

1

1

1

1

1

1

1

1

16-channel B) 2

16-channel C)

32-channel C)

16-channel C, F)

32-channel A,C)

1

1

1

1

8-channel

8-channel

8-channel

8-channel

16-channel

16-channel

8-channel

Selection guide

Manufacturer order number

I/O cards

PLC

Ana

l. In

put

Dig

ital

inp

utD

igit

al o

utp

utA

nal.

O

Order No. Order No.

Cables

Standard SITOP Connection

Qty Qty

C.7

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Type Type Type Type

InterfacesDigital Direct

I/OsAnal.

input/outputDigital opto-

decoupled inputDigital relay

output

Qty Qty QtyQty

Page 8: 1102340000_CAT4-5_C_EN

PLC Télémécanique - Micro

TSX DEZ 12D2

TSX DEZ 08A4

TSX DEZ 12D2K

TSX DEZ 08A5

TSX DEZ 32D2

TSX DSZ 04T22

TSX DSZ 08T2

TSX DSZ 08R5

TSX DSZ 08T2K

TSX DSZ 32T2

TSX DSZ 32R5

TSX DMZ 28DT

TSX DMZ 28DR

TSX DMZ 28AR

TSX DMZ 64DTK (*)

TSX DMZ 28DTK

TSX DMZ 16DTK

TSX 37-22 (integrated)

TSX AEZ 801

TSX AEZ 802

TSX AEZ 414

TSX 37-22 (integrated)

TSX ASZ 401

TSX ASZ 200

1

1

1

1

1

1

1

1

1

1

1

1

1

1

4

2

1

1

1

1

1

1

1

1

12-channel - H B)

8-channel - R

12-channel - H B)

8-channel - R

32-channel - H A, B)

16-channel - R D)

32-channel - R D)

16-channel - H B)

16-channel - R D)

16-channel - R D)

32-channel - H A, B)

16-channel - H B)

16-channel - H

1

1

1

1

1

1

1

1

2

2

1

1

1

16-channel B, E)

16-channel B, E)

16-channel B)

16-channel B)

16-channel B)

16-channel B)

1

1

2

1

2

1

8-channel C)

8-channel C)

8-channel C)

32-channel A, C)

12-channel C)

32-channel A, C)

12-channel C)

1

1

1

1

1

1

1

9 channels M

8-channel

8-channel

4-channel

9 channels M

4-channel

4-channel

1

1

1

1

1

1

1

Dig

ital

inp

utD

igit

al o

utp

utA

nal.

Inp

utA

nal.

Out

put

Dig

ital

Inp

ut/O

utp

ut

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789301020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

E) Four channels unused

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

Selection guide

7789312xxx

7789307xxx

7789301xxx

7789307xxx

7789314xxx

7789312xxx

7789312xxx

7789308xxx

7789301xxx

7789314xxx

7789330xxx

7789313xxx

7789331xxx

7789331xxx

7789301xxx

7789301xxx

7789301xxx

7789257xxx

7789311xxx

7789311xxx

7789309xxx

7789257xxx

7789310xxx

7789310xxx

Manufacturer order number Type Type Type TypeOrder No.

I/O cards

PLC Cables Interfaces

StandardDigital directinput/output

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty Qty

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

C.8

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 9: 1102340000_CAT4-5_C_EN

1

1

1

1

1

2

1

1

1

PLC Télémécanique - Premium

7789322xxx

7789322xxx

7789322xxx

7789315xxx

7789315xxx

7789315xxx

7789315xxx

7789301xxx

7789301xxx

7789301xxx

7789322xxx

7789317xxx

7789322xxx

7789317xxx

7789322xxx

7789316xxx

7789316xxx

7789318xxx

7789318xxx

7789316xxx

7789316xxx

7789301xxx

7789301xxx

7789320xxx

7789319xxx

7789259xxx

7789259xxx

7789261xxx

7789259xxx

7789320xxx

7789321xxx

7789259xxx

TSX DEY 08D2

TSX DEY 16D2

TSX DEY 16D3

TSX DEY 16A2 (1)

TSX DEY 16A3

TSX DEY 16A4

TSX DEY 16A5

TSX DEY 16FK (*)

TSX DEY 32D2K (*)

TSX DEY 64D2K (*)

TSX DSY 08T2

TSX DSY 08T22

TSX DSY 16T2

TSX DSY 08T31

TSX DSY 16T3

TSX DSY 08R5

TSX DSY 16R5

TSX DSY 08R5A

TSX DSY 08R4D

TSX DSY 08S5

TSX DSY 16S4

TSX DSY 32T2K (*)

TSX DSY 64T2K (*)

TSX AEY 414

TSX AEY 414

TSX AEY 420

TSX AEY 800

TSX AEY 810

TSX AEY 1600

TSX ASY 410

TSX ASY 410

TSX ASY 800

1

1

1

1

1

1

1

1

2

4

1

1

1

1

1

1

1

1

1

1

1

2

4

1

1

1

1

1

2

1

1

1

8-channel - H

16-channel - H B)

16-channel - H B, G)

16-channel - R

16-channel - R

16-channel - R

16-channel - R D)

16-channel - H B)

32-channel - H A, B)

32-channel - H A, B)

8-channel - R

8-channel - R

16-channel - H G)

16-channel - R D)

16-channel - R D)

16-channel - R D)

16-channel - R

16-channel - R D)

16-channel - R

1

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

16-channel B)

16-channel B)

16-channel B)

16-channel B)

16-channel B)

1

1

1

1

1

1

1

1

2

4

8-channel C)

16-channel C)

32-channel A,C)

32-channel A,C)

1

1

1

2

4-channel

8-channel

8-channel P

8-channel P

8-channel P

8-channel P

4-channel

4-channel

8-channel P

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789301020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

G) Only use modules without LED

1) Use in ac mode

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

Selection guide

Manufacturer order number

I/O cards

PLC

Dig

ital

inp

utD

igit

al o

utp

utA

nal.

Inp

utA

nal.

Out

put

Order No.

Cables

Standard

Qty

C.9

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Type Type Type Type

InterfacesDigital directinput/output

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty

Page 10: 1102340000_CAT4-5_C_EN

PLC Télémécanique - Twido

TWD DDI 8DT

TWD DDI 16DT

TWD DDI 16DK (1)

TWD DDI 32DK (1)

TWD DDO 8UT

TWD DDO 8TT

TWD DDO 16UK

TWD DDO 16TK

TWD DDO 32UK

TWD DDO 32TK

TWD DRA 8RT

TWD DRA 16RT

TWD LMDA 20DTK (1)

TWD LMDA 20DUK (1)

TWD LMDA 20DTR

TWD LMDA 40DTK (1)

TWD LMDA 40DUK (1)

TWD AMI 2HT

TWD AMO 1HT

TWD AMM 3HT

TWD ALM 3LT

1

1

1

2

1

1

1

1

2

2

1

1

1

1

1

1

2

2

1

1

1

1

8-channel - H

16-channel - H B)

16-channel - H B)

32-channel - H A, B)

8-channel - H

16-channel - H

32-channel - H A)

8-channel - R

16-channel - R D)

12-channel - H B)

12-channel - H B)

8-channel - H

12-channel - H B)

16-channel - R D)

12-channel - H B)

12-channel - H

8-channel - H

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

2

16-channel B)

16-channel B)

16-channel B)

16-channel B)

16-channel B)

16-channel B)

16-channel B)

1

1

2

1

1

1

2

8-channel C)

16-channel C)

32-channel A,C)

8-channel C)

8-channel C)

1

1

1

1

2

4-channel

4-channel

4-channel

4-channel

1

1

1

1

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789100020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

1) Use in positive logic

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

Selection guide

7789100xxx

7789100xxx

7789328xxx

7789328xxx

7789100xxx

7789100xxx

7789328xxx

7789329xxx

7789328xxx

7789329xxx

7789108xxx

7789104xxx

7789327xxx

7789326xxx

7789100xxx

7789104xxx

7789327xxx

7789326xxx

7789250xxx

7789250xxx

7789250xxx

7789250xxx

Manufacturer order number

I/O cards

PLC

Dig

ital

in

put

Dig

ital

out

put

Dig

ital

I/O

Ana

l. I/

O

Order No.

Cables

Standard

Qty

C.10

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Type Type Type Type

InterfacesDigital directinput/output

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty

Page 11: 1102340000_CAT4-5_C_EN

PLC Télémécanique - Quantum

140 DAI 540 00

140 DAI 540 00

140 DAI 553 00

140 DAI 740 00

140 DAI 740 00

140 DAI 340 00

140 DAI 340 00

140 DAI 353 00

140 DAI 440 00

140 DAI 440 00

140 DAI 453 00

140 DDI 841 00

140 DDI 853 00

140 DDI 353 00

140 DDI 364 00

140 DAO 840 00

140 DAO 840 00

140 DAO 842 10

140 DDO 353 00

140 DDO 843 00

140 DDO 364 00

140 DRA 840 00

140 DDM 390 00

140 ACI 030 00

140 ACI 030 00

140 AVI 030 00

140 AVI 030 00

140 ARI 030 10

140 ACI 040 00

140 AII 330 00

140 ACO 020 00

140 ACO 130 00

140 AIO 330 00

1

1

1

1

1

1

1

1

1

1

1

1

1

1

6

1

1

1

1

1

6

1

1

32-channel - R

16-channel - R

32-channel - R

32-channel - R D)

16-channel - R D)

32-channel - R

16-channel - R

32-channel - R

32-channel - R

16-channel - R

32-channel - R

16-channel - H B)

32-channel - H A, B)

32-channel - H A, B)

32-channel - H A, B)

32-channel - R D)

16-channel - R D)

16-channel - R D)

32-channel - R D)

16-channel - H B)

1

1

1

1

1

1

1

1

1

1

1

1

1

1

3

1

1

1

1

1

16-channel B)

16-channel B)

16-channel B)

16-channel B)

16-channel B)

1

2

2

6

1

32-channel A, C)

16-channel C, F)

32-channel A, C)

8-channel C)

1

1

3

1

8-channel

8-channel

8-channel

8-channel

8-channel

16-channel

8-channel

4-channel

8-channel

8-channel

1

1

1

1

1

1

1

1

1

1

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789301020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

Selection guide

7789118xxx

7789110xxx

7789118xxx

7789118xxx

7789110xxx

7789118xxx

7789110xxx

7789118xxx

7789118xxx

7789110xxx

7789118xxx

7789119xxx

7789121xxx

7789121xxx

7789301xxx

7789118xxx

7789112xxx

7789113xxx

7789121xxx

7789120xxx

7789301xxx

7789118xxx

7789133xxx

7789125xxx

7789134xxx

7789125xxx

7789134xxx

7789135xxx

7789123xxx

7789136xxx

7789124xxx

7789126xxx

7789137xxx

Manufacturer order number

I/O cards

PLC

Dig

ital

inp

utD

igit

al o

utp

utA

nal.

Inp

utA

nal.

Out

put

Dig

.I/

O

Order No.

Cables

Standard

Qty

C.11

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Type Type Type Type

InterfacesDigital directinput/output

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty

Page 12: 1102340000_CAT4-5_C_EN

PLC Télémécanique - M340

BMX DDI 1602

BMX DDI 1603

BMX DDI 3202K

BMX DDI 6402K

BMX DAI 1602 (1)

BMX DAI 1602 (2)

BMX DAI 1603

BMX DAI 1604

BMX DAO 1605

BMX DDO 1602

BMX DDO 1612

BMX DDO 3202K

BMX DDO 6402K

BMX DRA 0805

BMX DRA 1605

BMX DDM 16025

BMX DDM 16022

BMX DDM 3202K

BMX AMI 0410 (3)

BMX AMI 0410 (4)

BMX ART 0414

BMX ART 0814

BMX AMO 0210

BMX AMM 0600 (3)

BMX AMM 0600 (4)

1

1

1

2

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

2

1

1

1

16 channels-H (B)

16 channels-R

32 channels-H (A) (B)

32 channels-H (A) (B)

16 channels-H (B)

16 channels-R

16 channels-R

16 channels-R

16 channels-R (D) (K)

16 channels-R (D)

16 channels-R (D)

8 channels-H

8 channels-R (D)

8 channels-H

16 channels-H

1

1

1

2

1

1

1

1

1

1

1

1

1

2

2

16 channels-H (B)

16 channels-H (B)

16 channels-H (B)

16 channels-H (B)

1

2

4

1

16 channels (C)

16 channels (C)

16 channels (C)

16 channels (C)

1

1

2

4

4 channels

4 channels

16 channels

16 channels

4 channels

4 channels

4 channels

1

1

1

2

1

1

1

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789236020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

K) Each interface have one common

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

(1) use in 24 VDC, negative logic

(2) use in 24 VAC

(3) Use this cable for voltage signals.

(4) Use this cable for current signals.

Selection guide

7789380xxx

7789382xxx

7789387xxx

7789387xxx

7789630xxx

7789382xxx

7789382xxx

7789382xxx

7789383xxx

7789380xxx

7789380xxx

7789387xxx

7789387xxx

7789633xxx

7789384xxx

7789635xxx

7789386xxx

7789387xxx

7789637xxx

7789638xxx

7789639xxx

7789639xxx

7789640xxx

7789628xxx

7789629xxx

Manufacturer order number

I/O cards

PLC

Dig

ital

inp

utD

igit

al o

utp

utA

nal.

Inp

utA

nal.

I/O

Dig

ital

I/O

Order No.

Cables

Standard

Qty

Ana

l. O

C.12

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Type Type Type Type

InterfacesDigital directinput/output

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty

Page 13: 1102340000_CAT4-5_C_EN

PLC Rockwell - SLC 500

1746 - IB32

1746 - IV32

1746 - IB16

1746 - IC16

1746 - IN16

1746 - ITB16

1746 - ITV16

1746 - IV16

1746 - IB8

1746 - IV8

1746 - OB32

1746 - OV32

1746 - OB16

1746 - OB16E

1746 - OBP16

1746 - OG16

1746 - OV16

1746 - OVP16

1746 - OW16

1746 - OB8

1746 - OBP8

1746 - OV8

1746 - OW8

1746 - OX8

1746 - OW4

1746 - NI8

1746 - NI4

1746 - NO4V

1746 - NO4I

1746 - NIO4V

1746 - NIO4I

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

32-channel - H A, B)

32-channel - H A)

16-channel - H

16-channel - H

16-channel - H

16-channel - H

16-channel - H

16-channel - H

8-channel - H

8-channel - H

32-channel - H A)

16-channel - H

16-channel - H

16-channel - H

8-channel - H

16-channel - H F)

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

16-channel B) 2

32-channel A, C)

16-channel C)

16-channel C)

16-channel C)

16-channel C, F)

8-channel C)

8-channel C)

8-channel C, F)

8-channel C, F)

1

1

1

1

1

1

1

1

1

8-channel

4-channel

4-channel

4-channel

4-channel

4-channel

1

1

1

1

1

1

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789005020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

7789005xxx

7789670xxx

7789001xxx

7789001xxx

7789001xxx

7789001xxx

7789000xxx

7789000xxx

7789100xxx

7789100xxx

7789006xxx

7789006xxx

7789003xxx

7789003xxx

7789003xxx

7789003xxx

7789003xxx

7789003xxx

7789002xxx

7789100xxx

7789100xxx

7789100xxx

7789100xxx

7789100xxx

7789100xxx

7789011xxx

7789008xxx

7789010xxx

7789010xxx

7789009xxx

7789009xxx

Manufacturer order number

I/O cards

PLC

Selection guide

Dig

ital

inp

utD

igit

al o

utp

utA

nal.

IA

nal.

OA

nal.

I/O

Order No.

Cables

Standard

Qty

C.13

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Type Type Type Type

InterfacesDigital directinput/output

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty

Page 14: 1102340000_CAT4-5_C_EN

Selection guide

PLC Rockwell - Compact Logix

1769 - IA8I

1769 - IM12

1769 - IA16

1769 - IQ16

1769 - IQ16F

1769 - IQ32

1769 - OA8

1769 - OB8

1769 - OW8

1769 - OW8I

1769 - OA16

1769 - OB16

1769 - OB16P

1769 - OV16

1769 - OW16

1769 - OB32

1769 - IQ6XOW4

1769 - IF4

1769 - IF4I

1769 - IF8

1769 - OF2

1769 - OF4CI

1769 - OF8V

1769 - OF8C

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

16-channel - R

16-channel - R

16-channel - R

16-channel - H

16-channel - H

16-channel - H

8-channel - R

8-channel - R

16-channel - R

16-channel - R

16-channel - H

16-channel - R

16-channel - R

1

1

1

1

1

2

1

1

1

1

1

1

1

8-channel C)

16-channel C)

16-channel C)

16-channel C)

1

1

1

2

4-channel

4-channel

4-channel

4-channel

8-channel

8-channel

4-channel

4-channel

8-channel

8-channel

1

1

1

1

1

1

1

1

1

1

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789019020

Notes concerning the use of interface modules:

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

7789016xxx

7789025xxx

7789025xxx

7789019xxx

7789019xxx

7789019xxx

7789017xxx

7789015xxx

7789017xxx

7789016xxx

7789024xxx

7789018xxx

7789018xxx

7789018xxx

7789024xxx

7789018xxx

7789014xxx

7789026xxx

7789046xxx

7789027xxx

7789047xxx

7789028xxx

7789045xxx

7789029xxx

7789043xxx

7789044xxx

7789044xxx

Manufacturer order number

I/O cards

PLC

Dig

ital

inp

utD

igit

al o

utp

utA

nal.

Inp

utA

nal.

Out

put

Dig

.I/

O

Order No.

Cables

Standard

Qty

C.14

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Type Type Type Type

InterfacesDigital directinput/output

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty

Page 15: 1102340000_CAT4-5_C_EN

PLC Rockwell - Control Logix

1756-IA16

1756-IA16I

1756-IA8D

1756 - IB16

1756-IB16D

1756-IB16I

1756-IB32

1756 - IC16

1756-IH16I

1756-IM16I

1756 - IN16

1756 - OA16

1756-OA16I

1756 - OA8

1756-OA8D

1756-OA8E

1756-OB16D

1756 - OB16E

1756-OB16I

1756 - OB32

1756 - OB8

1756-OB8EI

1756-OC8

1756-OH8I

1756-ON8

1756-OW16I

1756-OX8I

1756-IF6I

1756-IF6I

1756-IF16

1756 - IF8

1756 - IF8

1756-IR6I

1756-OF4

1756-OF4

1756-OF6VI

1756-OF6CI

1756-OF8

1756-OF8

1756-OV16E

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

16-channel - R

32-channel - R

8-channel - R

16-channel - H B)

16-channel - H B)

16-channel - H B)

32-channel - H A, B)

16-channel - R

32-channel - R

32-channel - R D)

16-channel - R

16-channel - R D)

32-channel - R D)

8-channel - R

8-channel - R

8-channel - R

16-channel - R

16-channel - R

8-channel - R

32-channel - R D)

16-channel - R D)

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

16-channel B)

16-channel B)

16-channel B)

16-channel B)

1

1

1

2

16-channel C)

16-channel C)

16-channel C)

32-channel A, C)

8-channel C)

8-channel C)

1

1

1

1

1

1

8-channel

8-channel

16-channel

8-channel

8-channel

8-channel

4-channel

4-channel

8-channel

8-channel

8-channel

8-channel

16-channel

1

1

1

1

1

1

1

1

1

1

1

1

1

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789031020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

Selection guide

7789031xxx

7789030xxx

7789048xxx

7789039xxx

7789049xxx

7789049xxx

7789041xxx

7789031xxx

7789030xxx

7789030xxx

7789031xxx

7789056xxx

7789030xxx

7789057xxx

7789048xxx

7789048xxx

7789040xxx

7789058xxx

7789059xxx

7789042xxx

7789151xxx

7789152xxx

7789153xxx

7789154xxx

7789057xxx

7789030xxx

7789155xxx

7789156xxx

7789157xxx

7789032xxx

7789035xxx

7789036xxx

7789158xxx

7789033xxx

7789034xxx

7789157xxx

7789159xxx

7789037xxx

7789038xxx

7789165xxx

Manufacturer order number

I/O cards

PLC

Dig

ital

inp

utD

igit

al o

utp

utA

nal.

IA

nal.

O

Order No.

Cables

Standard

Qty

C.15

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Type Type Type Type

InterfacesDigital directinput/output

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty

Page 16: 1102340000_CAT4-5_C_EN

PLC Fanuc 90-30 and Alspa 8035

7789064xxx

7789064xxx

7789061xxx

7789067xxx

7789067xxx

7789634xxx

7789067xxx

7789067xxx

7789067xxx

7789067xxx

7789067xxx

7789066xxx

7789066xxx

7789063xxx

7789063xxx

7789069xxx

7789069xxx

7789068xxx

7789068xxx

7789068xxx

7789068xxx

7789068xxx

7789066xxx

7789066xxx

7789076xxx

7789075xxx

7789072xxx

7789072xxx

7789073xxx

7789073xxx

7789074xxx

IC693MDL230

IC693MDL231

IC693MDL240

IC693MDL241

IC693MDL630

IC693MDL632

IC693MDL634

IC693MDL640

IC693MDL643

IC693MDL645

IC693MDL646

IC693MDL654

IC693MDL655

IC693MDL310

IC693MDL340

IC693MDL730

IC693MDL731

IC693MDL732

IC693MDL733

IC693MDL740

IC693MDL741

IC693MDL742

IC693MDL752

IC693MDL753

IC693ALG220

IC693ALG221

IC693ALG222

IC693ALG223

IC693ALG390

IC693ALG391

IC693ALG442

1

1

1

1

1

1

1

1

1

1

1

2

2

1

1

1

1

1

1

1

1

1

2

2

1

1

1

1

1

1

1

16-channel - R

16-channel - R D)

16-channel - R

16-channel - H B, H)

8-channel - H

8-channel - R

8-channel - H H)

16-channel - H B)

16-channel - H B)

16-channel - H B, H)

16-channel - H B, H)

32-channel - H A, B, H)

32-channel - H A, B, H)

16-channel - R

16-channel - R

8-channel - H

8-channel - H

16-channel - H

32-channel - H A)

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

16-channel B, H)

16-channel B)

16-channel B)

16-channel B, H)

16-channel B, H)

16-channel B, H)

16-channel B, H)

1

1

1

1

1

2

2

8-channel C, F)

8-channel C, F)

16-channel C, F)

16-channel C, F)

32-channel A, C)

1

1

1

1

1

4-channel

4-channel

8-channel

8-channel

8-channel

8-channel

16-channel

1

1

1

1

1

1

1

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789067020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)

H) Use the PLC I/O card in positive logic only

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

Selection guide

Manufacturer order number

I/O cards

PLC

Dig

ital

inp

utD

igit

al o

utp

utA

nal.

In-

put

Ana

l. O

Ana

l. I

/O

Order No.

Cables

Standard

Qty

C.16

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Type Type Type Type

InterfacesDigital directinput/output

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty

Page 17: 1102340000_CAT4-5_C_EN

PLC OMRON CQM1

ID211

ID212

ID213

IA121

IA221

OC221

OC222

OD211

OD212

OD213

OD214

OA221

AD041

DA021

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

16-channel B, H)

16-channel B, H)

1

2

32-channel A, C)

16-channel C)

1

1

8-channel J)

4-channel J)

1

1

16-channel - H

16-channel - H B), H)

32-channel - H B, H)

8-channel - R

8-channel - R

8-channel - R

16-channel - R

8-channel - H

16-channel - H

8-channel - R

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789143020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

H) Only for positive logic, for negative logic invert the polarity of the source on the interface.

J) The PLC connector is not included. The wires of the cable are free and equiped with ferrules.

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

Selection guide

7789646xxx

7789647xxx

7789370xxx

7789652xxx

7789652xxx

7789653xxx

7789654xxx

7789653xxx

7789655xxx

7789372xxx

7789655xxx

7789656xxx

7789252xxx

7789250xxx

Manufacturer order number

I/O cards

PLC

Dig

ital

inp

utD

igit

al o

utp

utA

nal.

IA

nal.

O

Order No.

Cables

Standard

Qty

C.17

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Type Type Type Type

InterfacesDigital directinput/output

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty

Page 18: 1102340000_CAT4-5_C_EN

ID211

ID001

ID002

IA121

IA122

IM211

ID212

IA122-V

IA222-V

IM212

ID216

ID217

OC221

OC224-V

OC223

OD214

OD411

OD213

OA221

OC222-V

OD217

OD211

OA222-V

OC225

OD212

7789100xxx

7789100xxx

7789100xxx

7789108xxx

7789104xxx

7789108xxx

7789100xxx

7789104xxx

7789104xxx

7789100xxx

7789370xxx

7789370xxx

7789108xxx

7789104xxx

7789108xxx

7789100xxx

7789100xxx

7789100xxx

7789108xxx

7789104xxx

7789100xxx

7789100xxx

7789104xxx

7789104xxx

7789100xxx

PLC OMRON C200H

1

1

1

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

1

1

8-channel - H J)

8-channel - H J)

8-channel - H J)

8-channel - R J)

16-channel - R J)

8-channel - H J)

16-channel - H B, J)

16-channel - R J)

16-channel - R J)

16-channel - H B, J)

32-channel - H A, B, H)

32-channel - H A, B, H)

8-channel - R J)

16-channel - R J)

8-channel - R J)

8-channel - H J)

8-channel - H J)

8-channel - R J)

16-channel - R J)

12-channel - H J)

16-channel - R J)

16-channel - R J)

16-channel - H J)

1

1

1

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

1

1

16-channel B, J)

16-channel B, J)

16-channel B)

16-channel B)

1

1

2

4

8-channel C, J)

12-channel C, J)

1

1

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789142020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

H) Only for positive logic, for negative logic invert the polarity of the source on the interface.

J) The PLC connector is not included. The wires of the cable are free and equiped with forks.

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

Selection guide

Manufacturer order number

I/O cards

PLC

Dig

ital

inp

utD

igit

al o

utp

ut

Order No.

Cables

Standard

Qty

C.18

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Type Type Type Type

InterfacesDigital directinput/output

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty

Page 19: 1102340000_CAT4-5_C_EN

ID211

ID231

ID232

ID261

ID262

IA111

IA201

OC201

OC211

OD201

OD202

OD211

OD212

OD231

OD232

OD233

OD261

OD263

OA201

Dig

ital

inp

utD

igit

al o

utp

ut

7789645xxx

7789370xxx

7789371xxx

7789370xxx

7789371xxx

7789664xxx

7789648xxx

7789649xxx

7789664xxx

7789650xxx

7789650xxx

7789651xxx

7789651xxx

7789372xxx

7789373xxx

7789373xxx

7789372xxx

7789373xxx

7789648xxx

PLC OMRON CJ1W

1

1

1

2

2

1

1

1

1

1

1

1

1

1

1

1

2

2

1

16-channel - H B, H)

32-channel - H A, B, H)

32-channel - H A, B, H)

32-channel - H A, B, H)

32-channel - H A, B, H)

16-channel - R

8-channel - R

16-channel - R

16-channel - R

8-channel - H

32-channel - H A)

32-channel - H A)

32-channel - H A)

8-channel - R

1

1

1

2

2

1

1

1

1

1

1

2

2

1

16-channel B)

16-channel B)

16-channel B)

16-channel B)

16-channel B)

1

2

2

4

4

8-channel C)

16-channel C)

16-channel C)

32-channel A, C)

32-channel A, C)

1

1

1

1

1

Notes concerning cable lengths:

The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)

Example:

Cable 2 metres in length: Order number: 7789100020

Notes concerning the use of interface modules:

A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules

B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module

C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules

D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)

H) Only for positive logic, for negative logic invert the polarity of the source on the interface.

* All I/O signals with same common.

* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com

Selection guide

Manufacturer order number

I/O cards

PLC

Order No.

Cables

Standard

Qty

C.19

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -

Type Type Type Type

InterfacesDigital directinput/output

Anal. input/output

Digital opto-decoupled input

Digital relayoutput

Qty Qty Qty Qty

Page 20: 1102340000_CAT4-5_C_EN

V L 9445530000 RS 8ES-D-L H/V C.21

V 9441540000 (*) RS8ES-DP RSV1,6/V C.21

V L 9445630000 RS 12ES-D-L H/V C.22

C V 9445700000 RS 16ES H/V C.23

C V L 9445710000 RS 16ES-L H/V C.23

Z 9447700000 (*) RS 16ES H/Z C.23

Z L 9447710000 RS 16ES-L H/Z C.23

V L I 9445810000 RS 16ES-S-I-L H/V C.23

C V 9445720000 RS 16ES-D H/V C.24

C V L 9445730000 RS 16ES-D-L H/V C.24

Z L 9447730000 RS 16ES-D-L H/Z C.24

C V L I 9445750000 RS 16ES-D-I-L H/V C.24

Z L I 9447750000 (*) RS 16ES-D-I-L H/Z C.24

V F 9445820000 RS 16ES-D-F H/V C.25

C V 9445760000 RS 16ES-T H/V C.25

C V L 9445770000 RS 16ES-T-L H/V C.25

Z L 9447770000 RS 16ES-T-L H/Z C.25

V 9441500000 RS16ES RSV1,6/V C.26

V I 9441860000 RS16ES-I RSV1,6/V C.26

V 9441700000 RS16ES-DP RSV1,6/V C.27

V F 9441560000 RS16ES-DP/F RSV1,6/V C.27

V I 9441600000 (*) RS16E-3E/I RSV1,6/V C.28

C V 9445900000 RS 32ES H/V C.29

C V L 9445910000 RS 32ES-L H/V C.29

Z 9447900000 (*) RS 32ES H/Z C.29

Z L 9447910000 RS 32ES-L H/Z C.29

V L I 9445870000 RS 32ES-S-I-L H/V C.30

C V L 9445930000 RS 32ES-D-L H/V C.31

Z L 9447930000 RS 32ES-D-L H/Z C.31

C V L I 9445950000 RS 32ES-D-I-L H/V C.32

Z L I 9447950000 (*) RS 32ES-D-I-L H/Z C.32

V F 9445980000 RS 32ES-D-F H/V C.33

C V 9445960000 RS 32ES-T H/V C.34

C V L 9445970000 RS 32ES-T-L H/V C.34

Z L 9447970000 RS 32ES-T-L H/Z C.34

V 9441510000 RS32ES RSV1,6/V C.35

V I 9441870000 RS32ES-I RSV1,6/V C.35

V 9441710000 RS32ES-DP RSV1,6/V C.36

V F 9441570000 (*) RS32ES-DP/F RSV1,6/V C.36

V I 9441610000 RS32E-3E/I RSV1,6/V C.37

Note: Preferably articles in bold (*) under demand

No. of channels

Type of wiring

1 LED per chan.

Discon-nectable

FuseCompact version

Connection

Screw Tension c.

H or R System

Type

Order No. PageType

Functionalities Modules

8chan-nels

H System

H System

2-wire

1-wire

1-wire

2-wire

2-wire

3-wire

3-wire

2-wire

2-wire

H System

1-wire

3-wire

2-wire

H System

R System

R System

1-wire

2-wire

3-wire

R System

12chan.

16chan-nels

32chan-nels

Module overview - Direct inputs/outputs for digital cards

C.20

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 21: 1102340000_CAT4-5_C_EN

Direct inputs/outputs for digital cards

For 8-channel digital I/O cardsH System and R System

RS ES-D - 8-channel RS ES-DP - 8-channel

H-System – 2-wire (common + or –)Version: screw connection

R-System – 2-wire (common + or –)Version: screw connection

Screw connection without LED

Screw connection with LED

Tension clamp connection without LED

Tension clamp connection with LED

Note

Dimensions

Ordering data

--

+F+

18

20

1719

0.0 1

0.1 2

0.2 3

0.3 4

80.7

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

C

-

+C

C

Shu

nt

Connector H

E10/20 poles

B

C

A

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

24 V DC ± 10%

1 A (*)

3 A

Green

+ or – selectable with a jumper

3 A

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

74 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

RSV 1.6 connector – 12 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

250 V max

1 A (*)

3 A

+ or – selectable with a jumper

3 A

max 250 V

2 A

3.15 A

250 V AC

III

2

1.7 KV DC

-25…50 ºC

-40…60 ºC

68 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Type Order No.

RS 8ES-D-L H/V 9445530000

Type Order No.

RS8ES-DP RSV1,6/V 9441540000 (1)

(1) on demand

C.21

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 22: 1102340000_CAT4-5_C_EN

Direct inputs/outputs for digital cards

For 12-channel digital I/O cardsSystem H

RS ES-D - 12-channel

H-System – 2-wire (common + or –)Version: screw connection

Screw connection without LED

Screw connection with LED

Tension clamp connection without LED

Tension clamp connection with LED

Note

Dimensions

Ordering data

--

+F+

18

20

1719

0.0 1

0.1 2

0.2 3

0.3 4

121.3

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

C

-

+C

C

Shu

nt

Connector H

E10/20 poles

B

C

A

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

24 V DC ± 10%

1 A (*)

3 A

Green

+ or – selectable with a jumper

3 A

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

95 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

Type Order No.

RS 12ES-D-L H/V 9445630000

C.22

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 23: 1102340000_CAT4-5_C_EN

Direct inputs/outputs for digital cards

For 16-channel digital I/O cardsSystem H

RS ES-S - 16-channel RS ES-S-I - 16 disconnectable channels

Screw connection without LED

Screw connection with LED

Tension clamp connection without LED

Tension clamp connection with LED

Note

Dimensions

Ordering data

--

+F+

18

20

1719

0.0 1

0.1 2

0.2 3

0.3 4

161.7

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

Connector H

E10/20 poles

B

C

A

--

+F+

18

20

1719

0.0 1

0.1 2

0.2 3

0.3 4

161.7

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

Connector H

E10/20 poles

Disconnectableconnector

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

C version mm

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)

≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)

1 A (*)

3 A

Green (versions with LED)

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

81 x 87.5 x 72

46 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

24 V DC ± 10%

1 A (*)

3 A

Yes - each channel

Green

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

110 x 87.5 x72

(*) Observe the max. permissible current for the common wires

C

Type Order No.

RS 16ES H/V C C 9445700000

RS 16ES-L H/V C C 9445710000

RS 16ES H/Z 9447700000 (1)

RS 16ES-L H/Z 9447710000

C : compact version(1) on demand

Type Order No.

RS 16ES-S-I-L H/V 9445810000

C.23

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 24: 1102340000_CAT4-5_C_EN

CC

Direct inputs/outputs for digital cards

For 16-channel digital I/O cardsSystem H

RS ES-D - 16-channel RS ES-D-I - 16 disconnectable channels

H-System – 2-wire (common + or –)Versions: screw / tension clamp connection - compact

H-System – 2-wire (common + or –)Versions: screw / tension clamp connection - compact

Screw connection without LED

Screw connection with LED

Tension clamp connection without LED

Tension clamp connection with LED

Note

Dimensions

Ordering data

--

+F+

18

20

1719

0.0 1

0.1 2

0.2 3

0.3 4

161.7

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

C

-

+C

C

Shu

nt

Connector H

E10/20 poles

B

C

A--

+F+

18

20

1719

0.0 1

0.1 2

0.2 3

0.3 4

161.7

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

C

-

+C

C

Shu

nt

Disconnectableconnector

Connector H

E10/20 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

C version mm

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)

≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)

1 A (*)

3 A

Green (versions with LED)

+ or – selectable with a jumper

3 A

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

117 x 87.5 x 72

87 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)

24 V DC ± 10%

1 A (*)

3 A

Yes - each channel

Green

+ or – selectable with a jumper

3 A

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

119 x 87.5 x 72

90 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Type Order No.

RS 16ES-D H/V C C 9445720000

RS 16ES-D-L H/V C C 9445730000

RS 16ES-D-L H/Z 9447730000

C : compact version

Type Order No.

RS 16ES-D-I-L H/V C C 9445750000

RS 16ES-D-I-L H/Z 9447750000 (1)

C : compact version(1) on demand

C.24

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 25: 1102340000_CAT4-5_C_EN

C

Direct inputs/outputs for digital cards

For 16-channel digital I/O cardsSystem H

RS ES-D-F - 16-channel with fuse RS ES-T - 16-channel

H-System – 2-wire (common + or –)Version: screw connection

H System – 3-wire (common + and –)Versions: screw / tension clamp connection - compact

Screw connection without LED

Screw connection with LED

Tension clamp connection without LED

Tension clamp connection with LED

Note

Dimensions

Ordering data

--

+F+

18

20

1719

0.0 1

0.1 2

0.2 3

0.3 4

161.7

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

C

-

+C

C

Shu

nt

FUS

FUS

FUS

FUS

FUS

Connector H

E10/20 poles

B

C

A

--

+F+

18

20

1719

0.0 1

0.1 2

0.2 3

0.3 4

161.7

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

+

+

+

+

+

-

-

-

-

+F

Connector H

E10/20 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

C version mm

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

≤ 25V AC 50 V DC

1 A (*)

3 A

0.5 A fuse on each channel

+ or – selectable with a jumper

3 A

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

122 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)

≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)

1 A (*)

3 A

Green (versions with LED)

+ and –

3 A

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

110 x 87.5 x72

90 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Type Order No.

RS 16ES-D-F H/V 9445820000

Type Order No.

RS 16ES-T H/V C 9445760000

RS 16ES-T-L H/V C 9445770000

RS 16ES-T-L H/Z 9447770000

C : compact version

C.25

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 26: 1102340000_CAT4-5_C_EN

For 16-channel digital I/O cardsSystem R

RS ES - 16-channel RS ES-I – 16 disconnectable channels

System R – 1-wire cablingVersion: screw connection

System R – 1-wire cablingVersion: screw connection

Direct inputs/outputs for digital cards

Screw connection without LED

Screw connection with LED

Note

Dimensions

Ordering data

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

RSV 1.6 connector - 24 pole

0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)

max 150 V UC

1 A (*)

3 A

max 150 V

2 A

< 150 V AC

III

2

1.1 KV DC

-25…50 ºC

-40…60 ºC

97 x 87.5 x 68

(*) Observe the max. permissible current for the common wires

Technical data

RSV 1.6 connector - 24 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

250 V max

1 A (*)

3 A

Yes - each channel

max 250 V

2 A

3.15 A

250 V AC

III

2

1.7 KV DC

-25…50 ºC

-40…60 ºC

127 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Type Order No.

RS16ES RSV1,6/V 9441500000

Type Order No.

RS16ES-I RSV1,6/V 9441860000

C.26

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 27: 1102340000_CAT4-5_C_EN

For 16-channel digital I/O cardsSystem R

RS ES-DP - 16-channel RS ES-DP/F - 16-channel with fuse

R-System – 2-wire (common + or –)Version: screw connection

R-System – 2-wire (common + or –)Version: screw connection

Direct inputs/outputs for digital cards

Screw connection without LED

Screw connection with LED

Note

Dimensions

Ordering data

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

RSV 1.6 connector - 24 pole

0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)

max 150 V UC

1 A (*)

3 A

+ or – selectable with a jumper

3 A

max 150 V UC

2 A

3.15 A

< 150 V AC

III

2

1.1 KV DC

-25…50 ºC

-40…60 ºC

123 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

RSV 1.6 connector - 24 pole

0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)

max 150 V UC

1 A (*)

3 A

1 A fuse on each channel

+ or – selectable with a jumper

3 A

max 150 V UC

2 A

3.15 A

< 150 V AC

III

2

1.1 KV DC

-25…50 ºC

-40…60 ºC

123 x 109 x 72

(*) Observe the max. permissible current for the common wires

Type Order No.

RS16ES-DP RSV1,6/V 9441700000

Type Order No.

RS16ES-DP/F RSV1,6/V 9441560000

C.27

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 28: 1102340000_CAT4-5_C_EN

For 16-channel digital I/O cardsSystem R

RS ES-3 E/I - 16 disconnectable channels

R System – 3-wire (common + and –)Version: screw connection

Direct inputs/outputs for digital cards

Screw connection without LED

Screw connection with LED

Note

Dimensions

Ordering data

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

RSV 1.6 connector - 24 pole

0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)

max 150 V UC

1 A (*)

3 A

Yes - each channel

+ and –

3 A

max 150 V UC

3.15 A

< 150 V AC

III

2

1.1 KV DC

-25…50 ºC

-40…60 ºC

116 x 109 x 84

(*) Observe the max. permissible current for the common wires

Technical data

Type Order No.

RS16E-3E/I RSV1,6/V 9441600000 (1)

(1) on demand

C.28

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 29: 1102340000_CAT4-5_C_EN

For 32-channel digital I/O cardsSystem H

RS ES-S - 32-channel RS ES-S - 32-channel

H System – 1-wireVersion: screw connection - compact

H System – 1-wireVersion: tension clamp

C

Direct inputs/outputs for digital cards

Screw connection without LED

Screw connection with LED

Tension clamp connection without LED

Tension clamp connection with LED

Note

Dimensions

Ordering data

--

+F+

1820

1719

0.0 1

0.1 2

161.7I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

1820

1719

I/O P

CB

Con

nect

or

2.0 1

2.1 2

163.7

Connector (1) H

E10/20 poles C

onnector (2) HE

10/20 polesB

C

A

--

+F+

1820

1719

0.0 1

0.1 2

161.7I/O P

CB

Con

nect

orS

uppl

y V

olta

ge 1

FUS

I/O P

CB

Con

nect

or

2.0 1

2.1 2

163.7

--

+F+

1820

1719

Sup

ply

Vol

tage

2FUS

Connector (1) H

E10/20 poles C

onnector (2) HE

10/20 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C C version mm

Length A x width B x height C mm

Note

2 x HE 10 connectors - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

≤ 25V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)

1 A (*)

3 A

Green (version with LED)

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

90 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

2 x HE 10 connectors - 20 pole

0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)

≤ 25V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)

1 A (*)

3 A

Green (version with LED)

2 x 24 V DC / LED yellow (for each 16-channel block)

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

145 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Type Order No.

RS 32ES H/V C 9445900000

RS 32ES-L H/V C 9445910000

C : compact version

Type Order No.

RS 32ES H/Z 9447900000 (1)

RS 32ES-L H/Z 9447910000

(1) on demand

C.29

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 30: 1102340000_CAT4-5_C_EN

For 32-channel digital I/O cardsSystem H

RS ES-S-I - 32 disconnectable channels

H System – 1-wireVersion: screw connecion

Direct inputs/outputs for digital cards

Screw connection without LED

Screw connection with LED

Tension clamp connection without LED

Tension clamp connection with LED

Note

Dimensions

Ordering data

--

+F+

1820

1719

0.0 1

0.1 2

161.7I/O P

CB

Con

nect

orS

uppl

y V

olta

ge 1

FUS

I/O P

CB

Con

nect

or

2.0 1

2.1 2

163.7

--

+F+

1820

1719

Sup

ply

Vol

tage

2

FUS

Connector (1) H

E10/20 poles C

onnector (2) HE

10/20 poles

Disconnectableconnector

B

C

A

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

2 x HE 10 connectors - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

24 V DC ± 10%

1 A (*)

3 A

Yes - each channel

Green

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

220 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

Type Order No.

RS 32ES-S-I-L H/V 9445870000

C.30

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 31: 1102340000_CAT4-5_C_EN

For 32-channel digital I/O cardsSystem H

RS ES-D - 32-channel RS ES-D - 32-channel

H-System – 2-wire (common + or –)Version: screw connection - compact

H-System – 2-wire (common + or –)Version: tension clamp

C

Direct inputs/outputs for digital cards

Screw connection without LED

Screw connection with LED

Tension clamp connection without LED

Tension clamp connection with LED

Note

Dimensions

Ordering data

--

+F+

1820

1719

0.0 1

0.1 2

161.7I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

-

+C

C

Shu

nt

1820

1719

I/O P

CB

Con

nect

or

2.0 1

2.1 2

163.7

C

C

C

Connector (1) H

E10/20 poles C

onnector (2) HE

10/20 polesB

C

A

--

+F+

1820

1719

0.0 1

0.1 2

161.7I/O P

CB

Con

nect

orS

uppl

y V

olta

ge 1

FUS

C

C

C

-

+C

C

Shu

nt

I/O P

CB

Con

nect

or

2.0 1

2.1 2

163.7

C

C

C

--

+F+

1820

1719

Sup

ply

Vol

tage

2

FUS

-

+C

C

Shu

nt

Connector (1) H

E10/20 poles C

onnector (2) HE

10/20 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C C version mm

Length A x width B x height C mm

Note

2 x HE 10 connectors - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

24 V DC ± 10%

1 A (*)

3 A

Green

+ or – selectable with a jumper

3 A

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

170 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

2 x HE 10 connectors - 20 pole

0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)

24 V DC ± 10%

1 A (*)

3 A

Green

+ or – selectable with a jumper

3 A

2 x 24 V DC / LED yellow (for each 16-channel block)

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

230 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Type Order No.

RS 32ES-D-L H/V C 9445930000

C : compact version

Type Order No.

RS 32ES-D-L D/Z 9447930000

C.31

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 32: 1102340000_CAT4-5_C_EN

For 32-channel digital I/O cardsSystem H

RS ES-D-I - 32 disconnectable channels RS ES-D-I - 32 disconnectable channels

H-System – 2-wire (common + or –)Version: screw connection - compact

H-System – 2-wire (common + or –)Version: tension clamp

C

Direct inputs/outputs for digital cards

Screw connection without LED

Screw connection with LED

Tension clamp connection without LED

Tension clamp connection with LED

Note

Dimensions

Ordering data

--

+F+

1820

1719

0.0 1

0.1 2

161.7I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

-

+C

C

Shu

nt

1820

1719

I/O P

CB

Con

nect

or

2.0 1

2.1 2

163.7

C

C

C

Connector (1) H

E10/20 poles C

onnector (2) HE

10/20 polesDisconnectable

connectorB

C

A

--

+F+

1820

1719

0.0 1

0.1 2

161.7I/O P

CB

Con

nect

orS

uppl

y V

olta

ge 1

FUS

C

C

C

-

+C

C

Shu

nt

I/O P

CB

Con

nect

or

2.0 1

2.1 2

163.7

C

C

C

--

+F+

1820

1719

Sup

ply

Vol

tage

2

FUS

-

+C

C

Shu

nt

Connector (1) H

E10/20 poles C

onnector (2) HE

10/20 poles

Disconnectableconnector

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C C version mm

Length A x width B x height C mm

Note

2 x HE 10 connectors - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

24 V DC ± 10%

1 A (*)

3 A

Yes - each channel

Green

+ or – selectable with a jumper

3 A

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

170 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

2 x HE 10 connectors - 20 pole

0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)

24 V DC ± 10%

1 A (*)

3 A

Yes - each channel

Green

+ or – selectable with a jumper

3 A

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

230 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Type Order No.

RS 32ES-D-I-L H/V C 9445950000

C : compact version

Type Order No.

RS 32ES-D-I-L H/Z 9447950000 (1)

(1) on demand

C.32

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 33: 1102340000_CAT4-5_C_EN

For 32-channel digital I/O cardsSystem H

RS ES-D-F - 32-channel with fuse

H-System – 2-wire (common + or –)Version: screw connection

Direct inputs/outputs for digital cards

Screw connection without LED

Screw connection with LED

Tension clamp connection without LED

Tension clamp connection with LED

Note

Dimensions

Ordering data

--

+F+

1820

1719

0.0 1

0.1 2

161.7I/O P

CB

Con

nect

orS

uppl

y V

olta

ge 1

FUS

C

C

C

-

+C

C

Shu

nt

I/O P

CB

Con

nect

or

2.0 1

2.1 2

163.7

C

C

C

--

+F+

1820

1719

Sup

ply

Vol

tage

2

FUS

-

+C

C

Shu

ntFUS

FUS

FUS

FUS

FUS

FUS

Connector (1) H

E10/20 poles C

onnector (2) HE

10/20 polesB

C

A

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

2 x HE 10 connectors - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

≤ 25 V AC 50 V DC

1 A (*)

3 A

0.5 A fuse on each channel

+ or – selectable with a jumper

3 A

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

248 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

Type Order No.

RS 32ES-D-F H/V 9445980000

C.33

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 34: 1102340000_CAT4-5_C_EN

For 32-channel digital I/O cardsSystem H

RS ES-T - 32-channel RS ES-T - 32-channel

H System – 3-wire (common + and –)Version: screw connection - compact

H System – 3-wire (common + and –)Version: tension clamp

C

Direct inputs/outputs for digital cards

Screw connection without LED

Screw connection with LED

Tension clamp connection without LED

Tension clamp connection with LED

Note

Dimensions

Ordering data

+F

1820

1719

0.0 1

0.1 2

161.7

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

1820

1719

I/O P

CB

Con

nect

or

2.0 1

2.1 2

163.7

--

+

+

+

+

+

-

-

-

+F

+

+

+

-

-

-

Connector (1) H

E10/20 poles C

onnector (2) HE

10/20 polesB

C

A

+F

1820

1719

0.0 1

0.1 2

161.7I/O P

CB

Con

nect

orS

uppl

y V

olta

ge 1

FUS

I/O P

CB

Con

nect

or

2.0 1

2.1 2

163.7

--

+

+

+

+

+

-

-

-

+F

+

+

+

-

-

-

+F

1820

1719

Sup

ply

Vol

tage

2FUS

--

++

+F

Connector (1) H

E10/20 poles

Connector (2) H

E10/20 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C C version mm

Length A x width B x height C mm

Note

2 x HE 10 connectors - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)

1 A (*)

3 A

Green (versions with LED)

+ and –

3 A

24 V DC / LED yellow

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

176 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

2 x HE 10 connectors - 20 pole

0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)

24 V DC ± 10%

1 A (*)

3 A

Green

+ and –

3 A

2 x 24 V DC / LED yellow (for each 16-channel block)

2 A

3.15 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

221 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Type Order No.

RS 32ES-T H/V C 9445960000

RS 32ES-T-L H/V C 9445970000

C : compact version

Type Order No.

RS 16ES-T-L H/Z 9447970000

C.34

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 35: 1102340000_CAT4-5_C_EN

For 32-channel digital I/O cardsSystem R

RS ES - 32-channel RS ES-I – 32 disconnectable channels

System R – 1-wire cablingVersion: screw connection

System R – 1-wire cablingVersion: screw connection

Direct inputs/outputs for digital cards

Screw connection without LED

Screw connection with LED

Note

Dimensions

Ordering data

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

RSV 1.6 connector - 36 pole

0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)

max 150 V UC

1 A (*)

3 A

max 150 V UC

2 A

< 150 V AC

III

2

1.1 KV DC

-25…50 ºC

-40…60 ºC

148 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

RSV 1.6 connector - 36 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

250 V max

1 A (*)

3 A

Yes - each channel

max 250 V

2 A

3.15 A

250 V AC

III

2

1.7 KV DC

-25…50 ºC

-40…60 ºC

188 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Type Order No.

RS32ES RSV1,6/V 9441510000

Type Order No.

RS32ES-I RSV1,6/V 9441870000

C.35

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 36: 1102340000_CAT4-5_C_EN

For 32-channel digital I/O cardsSystem R

RS ES-DP - 32-channel RS ES-DP/F - 32-channel with fuse

R-System – 2-wire (common + or –)Version: screw connection

R-System – 2-wire (common + or –)Version: screw connection

Direct inputs/outputs for digital cards

Screw connection without LED

Screw connection with LED

Note

Dimensions

Ordering data

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

RSV 1.6 connector - 36 pole

0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)

max 150 V UC

1 A (*)

3 A

+ or – selectable with a jumper

3 A

max 150 V UC

2 A

3.15 A

< 150 V AC

III

2

1.1 KV DC

-25…50 ºC

-40…60 ºC

200 x 87.5 x 72

(*) Observe the max. permissible current for the common wires

Technical data

RSV 1.6 connector - 36 pole

0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)

max 150 V UC

1 A (*)

3 A

1 A fuse on each channel

+ or – selectable with a jumper

3 A

max 150 V UC

2 A

3.15 A

< 150 V AC

III

2

1.1 KV DC

-25…50 ºC

-40…60 ºC

200 x 109 x 84

(*) Observe the max. permissible current for the common wires

Type Order No.

RS32ES-DP RSV1,6/V 9441710000

Type Order No.

RS32ES-DP/F RSV1,6/V 9441570000 (1)

(1) on demand

C.36

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 37: 1102340000_CAT4-5_C_EN

For 32-channel digital I/O cardsSystem R

RS ES-3 E/I - 32 disconnectable channels

R System – 3-wire (common + and –)Version: screw connection

Direct inputs/outputs for digital cards

Screw connection without LED

Screw connection with LED

Note

Dimensions

Ordering data

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Operating voltage

Max. current per channel

Max. total current

Fuse per channel

Disconnection per channel

LED status indication per channel

Polarity distribution

Max. current of joint potential

PLC card supply voltage / LED voltage status

PLC card supply current

PLC card supply current fuse

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

RSV 1.6 connector - 36 pole

0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)

max 150 V UC

1 A (*)

3 A

Yes - each channel

+ and –

3 A

max 150 V UC

2 A

3.15 A

< 150 V AC

III

2

1.1 KV DC

-25…50 ºC

-40…60 ºC

188 x 109 x 84

(*) Observe the max. permissible current for the common wires

Technical data

Type Order No.

RS32E-3E/I RSV1,6/V 9441610000

C.37

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 38: 1102340000_CAT4-5_C_EN

C V L O 9446900000 RS16E-OD 24-48V H/V C.39

C V L O 9446910000 (*) RS16E-OD 115 H/V C.40

C V L O 9446920000 (*) RS16E-OD 230V H/V C.40

Note: Preferably articles in bold (*) on demand

1 LED per chan.

Pluggableoptocoupler

Compact version

Connection

Screw Tension c.

Type

Order No. PageType

Functionalities Modules

16chan-nels

H System 2-wire

No. of channels

Type of wiring

H or R System

Module overview – Opto-decoupled inputs/outputs for digital cards

C.38

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 39: 1102340000_CAT4-5_C_EN

Pow

er supply

1

E1

Inpu

t PC

B C

onne

ctor

R

C1 C2

C1F

8

E8 RC1F

--

+

18

20

1719

Supply V

oltage

FUS

9

E9 R

C3 C4

C3F

16

E16 RC3F

+

FU

SF

US

Connector H

E10/20 poles

DimensionsSystem H – Pluggable optocouplersVersion: screw connection

For 16-channel digital cards RSE OD – 16-channel

A

C

BC

Opto-decoupled inputs for digital cards

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Operating Voltage

Input current AC

Input current DC

Switching voltage AC

Switching voltage DC

Max. switching current/voltage

Optocoupler polarisation voltage

Continuous current per optocoupler

Fuse (optocoupler power supply)

I/O card max. supply current

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C C version mm

Note

24-48 V version

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

24…48 V UC

9…21 mA AC

7…16 mA DC

20 V AC

19 V DC

100 mA / 48 V–

24 up to 48 V DC

100 mA

1 A

2 A

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

148 x 109 x 72

(*) Observe the max. permissible current for the common wires

Type Order No.

RS16E-OD 24-48V H/V C 9446900000

C : compact version

Technical data

Ordering data

AccessoriesNote Optocoupler - 4061180000

C.39

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 40: 1102340000_CAT4-5_C_EN

Opto-decoupled inputs for digital cards

1

E1

Inpu

t PC

B C

onne

ctor

R

C1 C2

C1F

8

E8 RC1F

--

+

18

20

1719

Supply V

oltage

FUS

9

E9 R

C3 C4

C3F

16

E16 RC3F

+

FU

SF

US

Connector H

E10/20 poles

DimensionsSystem H – Pluggable optocouplersVersion: screw connection

For 16-channel digital cards RSE OD – 16-channel

A

C

BC

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Operating Voltage

Input current AC

Input current DC

Switching voltage AC

Switching voltage DC

Max. switching current/voltage

Optocoupler polarisation voltage

Continuous current per optocoupler

Fuse (optocoupler power supply)

I/O card max. supply current

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C C version mm

Note

115 V version

230 V version

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

115 V UC / 230 V AC

7 mA AC / 7 mA AC

7 mA DC / –

80 V AC / 150 V AC

75 V DC / –

100 mA / 48 V–

24 up to 48 V DC

100 mA

1 A

2 A

250 V AC

III

2

1.2 KVrms

-25…40 ºC

-40…60 ºC

148 x 109 x 72

(*) Observe the max. permissible current for the common wires

Type Order No.

RS16E-OD 115 H/V C 9446910000 (1)

RS16E-DO 230V H/V C 9446920000 (1)

C : compact version(1) on demand

Technical data

Ordering data

AccessoriesNote Optocoupler - 4061180000

C.40

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 41: 1102340000_CAT4-5_C_EN

C.41

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 42: 1102340000_CAT4-5_C_EN

C V 1CO 9445000000 RSM8C-1CO H/V C.43

C Z 1CO 9447000000 RSM8C-1CO H/Z C.43

C V 1CO 9445060000 (*) RSM12C-1CO H/V C.44

V 1CO 9444610000 RSM16-NV/1CO 24V (-/+) C.45

Z 1CO 9444660000 RSM16-NZ/1CO 24V (-/+) C.45

C V 1CO 9445100000 RSM16C-1CO H/V C.46

C Z 1CO 9447100000 RSM16C-1CO H/Z C.46

C V 1CO 1079390000 (*) RSM16 SLIM-1CO H/V C.47

C V 1CO 1094970000 (*) RSM16 SLIM-1CO H/V SOCKET C.47

V 2CO 9445160000 RSM16-2CO H/V C.48

C Z 2CO 9447160000 RSM16-2CO H/Z C.48

V 1CO P 9445140000 RSM16-1CO-Fo H/V C.49

V 1CO F 9445120000 RSM16-1CO-Fu H/V C.50

Z 1CO F 9447120000 RSM16-1CO-Fu H/Z C.50

V 1NO E 9445180000 RSM16 1T/Solen. ctrl 24V DC H/V C.51

C V 1CO 1108470000 (*) RSM32C-1CO 24VDC H/V C.52

C Z 1CO 9447200000 RSM32C-1CO H/Z C.52

V 1CO F 9445220000 RSM32-1CO-Fu H/V C.53

Note: Preferably articles in bold (*) on demand

8chan.

H System

H System

No. of channels

Type of contact

FuseForce

functionSolen. ctrl.Compact

version

Connection

Screw Tension c.

H or R System

Type

Order No. PageType

Functionalities Modules

H System

H System

12chan.

16chan-nels

32chan-nels

Module overview - Relay outputs for digital cards

C.42

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 43: 1102340000_CAT4-5_C_EN

--

+F+

18

20

1719

Sup

ply

Vol

tage

FUS

1

2

3

8

Relay 1

Relay 2

Relay 3

Relay 8

11

14

12

21

24

22

31

34

32

81

84

82

Out

put P

CB

Con

nect

or

Connector H

E10/20 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Coil rated voltage

Coil rated current/power

Coil status indicator

PLC card supply current fuse

I/O card max. supply current

Output data

Contact configuration

Max. switching power/voltage

Relay type

Max. continuous/inrush current

Contact material

Fuse (contact)

Mechanical service life

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

Screw connection

Tension clamp connection

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)

24 V ±10%

17 mA / 0.4 W

LED green

3.15 A

2 A

1CO

3000 VA / 250 V AC

16 A version

5 A/16 A

AgNi 90/10

30 x 106 operations

250 V AC

III

2

1.2 KVrms

-25…40 ºC

-40…60 ºC

110 x 109 x 68

(*) No main-circuits

Type Order No.

RSM8C-1CO H/V 9445000000

RSM8C-1CO H/Z 9447000000

Technical data

Ordering data

AccessoriesNote

Dimensions

For 8-channel digital output cards RSM-C – 8-channel

Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000

H System – 1CO relayVersions: screw / tension clamp

A

C

B

Relay outputs for digital cards

C.43

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 44: 1102340000_CAT4-5_C_EN

HE

10 20-pole connector

--

+F+

18

20

1719

Sup

ply

Vol

tage

FUS

1

2

3

12

Relay 1

Relay 2

Relay 3

Relay 12

11

14

12

21

24

22

31

34

32

121

124

122

Out

put P

CB

Con

nect

or

Connector H

E10/20 poles

Screw connection

Tension clamp connection

Note

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Coil rated voltage

Coil rated current/power

Coil status indicator

PLC card supply current fuse

I/O card max. supply current

Output data

Contact configuration

Max. switching power/voltage

Relay type

Max. continuous/inrush current

Contact material

Fuse (contact)

Mechanical service life

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

24 V ±10%

17 mA / 0.4 W

LED green

3.15 A

2 A

1CO

3000 VA / 250 V AC

16 A version

5 A/16 A

AgNi 90/10

30 x 106 operations

250 V AC

III

2

1.2 KVrms

-25…40 ºC

-40…60 ºC

147 x 109 x 68

(*) No main-circuits

Type Order No.

RSM12C-1CO H/V 9445060000

Technical data

Ordering data

AccessoriesNote

Dimensions

For 12-channel digital output cards RSM-C – 12-channel

Relay RCL314024 - 869326000 Static relay ODC - 8576340000Static relay OAC - 8576370000

H System – 1CO relayVersion: screw connection

A

C

B

Relay outputs for digital cards

C.44

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 45: 1102340000_CAT4-5_C_EN

COM

U

18

20

1719

Sup

ply

Vol

tage

1

2

3

16

Relay 1

Relay 2

Relay 3

Relay 16

11

14

12

21

24

22

31

34

32

161

164

162

Out

put P

CB

Con

nect

or

Input PC

B C

onnector

E1

E2

E3

E16

Connector H

E10/20 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Coil rated voltage

Coil rated current/power

Coil status indicator

PLC card supply current fuse

I/O card max. supply current

Output data

Contact configuration

Max. switching power/voltage

Relay type

Max. continuous/inrush current

Contact material

Fuse (contact)

Mechanical service life

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

Screw connection

Tension clamp connection

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)

24 V ±10%

22 mA / 0.5 W

LED green

2 A

1CO

3000 VA / 250 V AC

16 A version

5 A/16 A

AgNi 90/10

30 x 106 operations

250 V AC

III

2

1.2KVrms

-25…40 ºC

-40…60 ºC

267 x 87.5 x 68

(*) No main-circuits

Type Order No.

RSM16-NV/1CO 24V (-/+) 9444610000

RSM16-NZ/1CO 24V (-/+) 9444660000

Technical data

Ordering data

AccessoriesNote

Dimensions

For 16-channel digital output cards RSM-S – 16-channel

Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000

1CO relayVersions: screw / tension clamp

A

C

B

Relay outputs for digital cards

C.45

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 46: 1102340000_CAT4-5_C_EN

--

+F+

18

20

1719

Sup

ply

Vol

tage

FUS

1

2

3

16

Relay 1

Relay 2

Relay 3

Relay 16

11

14

12

21

24

22

31

34

32

161

164

162

Out

put P

CB

Con

nect

or

Connector H

E10/20 poles

Screw connection

Tension clamp connection

Note

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Coil rated voltage

Coil rated current/power

Coil status indicator

PLC card supply current fuse

I/O card max. supply current

Output data

Contact configuration

Max. switching power/voltage

Relay type

Max. continuous/inrush current

Contact material

Fuse (contact)

Mechanical service life

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)

24 V ±10%

17 mA / 0.4 W

LED green

3.15 A

2 A

1CO

3000 VA / 250 V AC

16 A version

5 A/16 A

AgNi 90/10

30 x 106 operations

250 V AC

III

2

1.2 KVrms

-25…40 ºC

-40…60 ºC

185 x 109 x 68

(*) No main-circuits

Type Order No.

RSM16C-1CO H/V 9445100000

RSM16C-1CO H/Z 9447100000

Technical data

Ordering data

AccessoriesNote

Dimensions

For 16-channel digital output cards RSM-C – 16-channel

Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000

H System – 1CO relayVersions: screw / tension clamp

A

C

B

Relay outputs for digital cards

C.46

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 47: 1102340000_CAT4-5_C_EN

-

+

18

20

1719

Sup

ply

Vol

tage

1

2

3

16

Relay 1

Relay 2

Relay 3

Relay 16

11

14

12

21

24

22

31

34

32

161

164

162

Out

put P

CB

Con

nect

or

Connector H

E10/20 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Coil rated voltage

Coil rated current/power

Coil status indicator

PLC card supply current fuse

I/O card max. supply current

Output data

Contact configuration

Max. switching power/voltage

Relay type

Max. continuous/inrush current

Contact material

Fuse (contact)

Mechanical service life

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C C version mm

Note

Equipped with 1 CO relay screw connection

Empty slot, screw connection

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)

24 V ±10%

8 mA / 0.2 W

LED green

2 A

1CO

1500 VA / 250 V AC

6 A version

4 A/6 A

AgSnO2

5 x 106 operations

250 V AC

III

2

1.2 KVrms

-25…40 ºC

-40…60 ºC

111 x 87.5 x 85

(*) No main-circuits

Type Order No.

RSM16 SLIM-1CO H/V C 1079390000 (1)

RSM16 SLIM-1CO H/V SOCKET C 1094970000 (1)

C : compact version(1) on demand

Technical data

Ordering data

AccessoriesNote

Dimensions

For 16-channel digital output cards RSM SLIM – 16-channel

1CO relay - 4061590000Optocoupler ODC 24V/2A - 4061190000

H System – with 1CO relay / empty socketVersion: screw connection - compact

A

C

BC

Relay outputs for digital cards

C.47

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 48: 1102340000_CAT4-5_C_EN

--

+F+

18

20

1719

Sup

ply

Vol

tage

FUS

1

2

3

16

Relay 1

Relay 2

Relay 3

Relay 16

121

124

122

221

224

222

331

334

332

1621

1624

1622

Out

put P

CB

Con

nect

or

111

114

112

211

214

212

311

314

312

1611

1614

1612

Connector H

E10/20 poles

Screw connection

Tension clamp connection

Note

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Coil rated voltage

Coil rated current/power

Coil status indicator

PLC card supply current fuse

I/O card max. supply current

Output data

Contact configuration

Max. switching power/voltage

Relay type

Max. continuous/inrush current

Contact material

Fuse (contact)

Mechanical service life

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)

24 V ±10%

17 mA / 0.4 W

LED green

3.15 A

2 A

2CO

2000 VA / 250 V AC

2x8 A version

4 A/8 A

AgNi 90/10

30 x 106 switching cycles

250 V AC

III

2

1.2 KVrms

-25…40 ºC

-40…60 ºC

263 x 109 x 75

(*) No main-circuits

Type Order No.

RSM16-2CO H/V 9445160000

RSM16-2CO H/Z 9447160000

Technical data

Ordering data

AccessoriesNote

Dimensions

For 16-channel digital output cards RSM-2CO – 16-channel

2CO Relay - 4058570000

System H – 2CO relayVersions: screw / tension clamp

A

C

B

Relay outputs for digital cards

C.48

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 49: 1102340000_CAT4-5_C_EN

--

+F+

18

20

1719

Sup

ply

Vol

tage

FUS

1

2

3

16

Relay 2

Relay 3

Relay 16

11

14

12

21

24

22

31

34

32

161

164

162

Out

put P

CB

Con

nect

or

SW1

SW2

SW3

SW16

Switch

Connector H

E10/20 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Coil rated voltage

Coil rated current/power

Coil status indicator

PLC card supply current fuse

I/O card max. supply current

Output data

Contact configuration

Max. switching power/voltage

Relay type

Max. continuous/inrush current

Contact material

Fuse (contact)

Mechanical service life

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

Screw connection

Tension clamp connection

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

24 V ±10%

17 mA / 0.4 W

LED green

3.15 A

2 A

1CO

3000 VA / 250 V AC

16 A version

2 A/16 A

AgNi 90/10

30 x 106 operations

250 V AC

III

2

1.2 KVrms

-25…40 ºC

-40…60 ºC

263 x 109 x 75

(*) No main-circuits

Type Order No.

RSM16-1CO-Fo H/V 9445140000

Technical data

Ordering data

AccessoriesNote

Dimensions

For 16-channel digital output cards RSM-Fo - 16-channel with force function

Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000

H System – 1CO relayVersion: screw connection

A A

C

B

Relay outputs for digital cards

C.49

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 50: 1102340000_CAT4-5_C_EN

--

+F+

18

20

1719

Sup

ply

Vol

tage

FUS

1

2

3

16

Relay 1

Relay 2

Relay 3

Relay 16

11

14

12

21

24

22

31

34

32

161

164

162

Out

put P

CB

Con

nect

or FUS

FUS

FUS

FUS

Connector H

E10/20 poles

Screw connection

Tension clamp connection

Note

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Coil rated voltage

Coil rated current/power

Coil status indicator

PLC card supply current fuse

I/O card max. supply current

Output data

Contact configuration

Max. switching power/voltage

Relay type

Max. continuous/inrush current

Contact material

Fuse (contact)

Mechanical service life

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.5...1.5 / 0.5...1.5 mm2 (AWG 16...26)

24 V ±10%

17 mA / 0.4 W

LED green

3.15 A

2 A

1CO

3000 VA / 250 V AC

16 A version

5 A/16 A

AgNi 90/10

5 A fuse on each channel

30 x 106 operations

250 V AC

III

2

1.2 KVrms

-25…40 ºC

-40…60 ºC

261 x 109 x 75

(*) No main-circuits

Type Order No.

RSM16-1CO-Fu H/V 9445120000

RSM16-1RT-Fu H/Z 9447120000

Technical data

Ordering data

AccessoriesNote

Dimensions

For 16-channel digital output cards RSM-Fu – 16-channel with fuse

Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000

H System – 1CO relayVersions: screw / tension clamp

A A

C

B

Relay outputs for digital cards

C.50

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 51: 1102340000_CAT4-5_C_EN

--

+F+

18

20

1719

Sup

ply

Vol

tage

FUS

1

8

9

16

Relay 1

Relay 8

Relay 9

Relay 16

C1

C2

F1

Out

put P

CB

Con

nect

or

I1

F8

I8

C3

C4

F9

I9

F16

I16

FUS

FUS

FUS

FUS

Connector H

E10/20 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Coil rated voltage

Coil rated current/power

Coil status indicator

PLC card supply current fuse

I/O card max. supply current

Output data

Contact configuration

Max. switching power/voltage

Relay type

Max. continuous/inrush current

Contact material

Fuse (contact)

Mechanical service life

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

Screw connection

Tension clamp connection

Note

HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

24 V ±10%

17 mA / 0.4 W

LED green

3.15 A

2 A

1CO

3000 VA / 250 V AC

16 A version

2 A/16 A

AgNi 90/10

30 x 106 operations

250 V AC

III

2

1.2 KVrms

-25…40 ºC

-40…60 ºC

290 x 109 x 75

(*) No main-circuits

Type Order No.

RSM16 1T/Solen. ctrl. 24V DC H/V 9445180000

Technical data

Ordering data

AccessoriesNote

Dimensions

For 16-channel digital output cards RSM-Solen. ctrl. - 16-channel for solenoid

Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000

H System – 1O relayVersion: screw connection

A

C

B

Relay outputs for digital cards

C.51

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 52: 1102340000_CAT4-5_C_EN

--

+F+

18

20

1719

Sup

ply

Vol

tage

1

FUS

1

2

3

16

Relay 1

Relay 2

Relay 3

Relay 16

11

14

12

21

24

22

31

34

32

161

164

162

Out

put P

CB

Con

nect

or

--

+F+

18

20

1719

Sup

ply

Vol

tage

2

FUS

1

2

3

16

Relay 17

Relay 18

Relay 19

Relay 32

171

174

172

181

184

182

191

194

192

321

324

322

Out

put P

CB

Con

nect

or

Connector (1) H

E10/20 poles

Connector (2) H

E10/20 polesScrew connection

Tension clamp connection

Note

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Coil rated voltage

Coil rated current/power

Coil status indicator

PLC card supply current fuse

I/O card max. supply current

Output data

Contact configuration

Max. switching power/voltage

Relay type

Max. continuous/inrush current

Contact material

Fuse (contact)

Mechanical service life

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

2 x HE 10 connector - 20 pole

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)

24 V ±10%

17 mA / 0.4 W

LED green

3.15 A

2 A

1CO

3000 VA / 250 V AC

16 A version

5 A/16 A

AgNi 90/10

30 x 106 operations

250 V AC

III

2

1.2 KVrms

-25…40 ºC

-40…60 ºC

365 x 109 x 68

(*) No main-circuits

Type Order No.

RSM32C-1CO 24VDC H/V 1108470000(1)

RSM32C-1CO H/Z 9447200000

(1) on demand

Technical data

Ordering data

AccessoriesNote

Dimensions

For 32-channel digital output cards RSM-C – 32-channel

Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000

H System – 1 CO relayVersions: screw / tension clamp

A

C

B

Relay outputs for digital cards

C.52

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 53: 1102340000_CAT4-5_C_EN

--

+F+

18

20

1719

Sup

ply

Vol

tage

1

FUS

1

2

3

16

Relay 1

Relay 2

Relay 3

Relay 16

11

14

12

21

24

22

31

34

32

161

164

162

Out

put P

CB

Con

nect

or

--

+F+

18

20

1719

Sup

ply

Vol

tage

2

FUS

1

2

3

16

Relay 17

Relay 18

Relay 19

Relay 32

171

174

172

181

184

182

191

194

192

321

324

322

Out

put P

CB

Con

nect

orFUS

FUS

FUS

FUS

FUS

FUS

FUS

FUS

Connector (1) H

E10/20 poles

Connector (2) H

E10/20 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input data

Coil rated voltage

Coil rated current/power

Coil status indicator

PLC card supply current fuse

I/O card max. supply current

Output data

Contact configuration

Max. switching power/voltage

Relay type

Max. continuous/inrush current

Contact material

Fuse (contact)

Mechanical service life

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

Screw connection

Tension clamp connection

Note

2 x HE 10 20-pole connectors

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

24 V ±10%

17 mA / 0.4 W

LED green

3.15 A

2 A

1CO

3000 VA / 250 V AC

16 A version

5 A/16 A

AgNi 90/10

5 A fuse on each channel

30 x 106 operations

250 V AC

III

2

1.2 KVrms

-25…40 ºC

-40…60 ºC

511 x 109 x 75

(*) No main-circuits

Type Order No.

RSM32-1CO-Fu H/V 9445220000

Technical data

Ordering data

AccessoriesNote

Dimensions

For 32-channel digital cards RSM-Fu – 32-channel with fuse

Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000

H System – 1 CO relayVersion: screw connection

A A

C

B

Relay outputs for digital cards

C.53

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 54: 1102340000_CAT4-5_C_EN

V M 9448000000 RS4AIO-DP SD/V C.55

V M I T 9448100000 RS4AIO/I-M-DP SD/V C.55

V M 9448010000 RS8AIO-DP SD/V C.56

V M I T 9448110000 RS8AIO/I-M-DP SD/V C.56

Z M I T 9449110000 RS8AIO/I-M-DP SD/Z C.56

V M I 9448030000 RS8AI PREM/APR SD/V C.57

V 9448040000 RS8E1AO MICRO SD/V C.57

V M 9448020000 RS16AIO-DP SD/V C.58

V M I T 9448120000 RS16AIO/I-M-DP SD/V C.58

Z M I T 9449120000 RS16AIO/I-M-DP SD/Z C.58

Note: Preferably articles in bold

Disconnec-table

Test points

Compact version

Connection

Screw Tension c.

Type

Order No. PageType

Functionalities Modules

4channels

Standard

8chan-nels

8channels P

Standard

16chan-nels

Standard

Premium(Télémécanique)

9channels M

Micro(Télémécanique)

Number of

channels

Common distribution

PLC

Module overview – Analogue input/output

C.54

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 55: 1102340000_CAT4-5_C_EN

For 4-channel analogue I/O cards RS AIO-DP - 4-channel RS AIO/I-M-DP - 4-channel

Common distributionVersion: screw connection

Common distribution, disconnection and testVersion: screw connection

Input / output for analogue cards

Screw connection

Tension clamp connection

Note

Dimensions

Ordering data

-

+F+

2

10

19

0+ 3

0- 11

1+ 4

1- 12

143-

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

C

-

+C

C

Shu

nt

63+

C

Shielded

ConnectorS

ubD 15 poles

B

C

A

Sub

Dm

ale

-

+F+

2

10

19

0+ 3

0- 11

1+ 4

1- 12

143-

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

C

-

+C

C

Shu

nt

63+

C

Shielded

Test point

Connector S

ubD 15 poles

Disconnectableconnector

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Number of channels

Operating voltage

Common distribution

PLC card supply current fuse

Disconnection

Current measuring test point

Voltage measuring test point

Continuous shielding

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

15-pole D-SUB male connector

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

4

≤ 25 V AC 50 V DC

Shield, + or – (selectable with jumper)

3.15 A

Yes

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

75 x 87.5 x 72

Technical data

15-pole D-SUB male connector

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

4

≤ 25 V AC 50 V DC

Shield, + or – (selectable with jumper)

3.15 A

Yes - each channel

Yes - 2 female testing points dia. 4 mm

Yes

Yes

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

73 x 109 x 81

Type Order No.

RS4AIO-DP SD/V 9448000000

Type Order No.

RS4AIO/I-M-DP SD/V 9448100000

C.55

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 56: 1102340000_CAT4-5_C_EN

For 8-channel analogue I/O cards RS AIO-DP - 8-channel RS AIO/I-M-DP - 8-channel

Common distributionVersion: screw connection

Common distribution, disconnection and testVersions: screw / tension clamp

Input / output for analogue cards

Screw connection

Tension clamp connection

Note

Dimensions

Ordering data

-

+F+

2

15

114

0+ 3

0- 16

1+ 4

1- 17

237-

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

C

-

+C

C

Shu

nt

107+

C

Shielded

Connector S

ubD 25 poles

B

C

A

Sub

Dm

ale

-

+F+

2

15

114

0+ 3

0- 16

1+ 4

1- 17

237-

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

C

-

+C

C

Shu

nt

107+

C

Shielded

Test point

Connector S

ubD 25 poles

Disconnectableconnector

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Number of channels

Operating voltage

Common distribution

PLC card supply current fuse

Disconnection

Current measuring test point

Voltage measuring test point

Continuous shielding

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

25-pole D-SUB male connector

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

8

≤ 25 V AC 50 V DC

Shield, + or – (selectable with jumper)

3.15 A

Yes

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

117 x 87.5 x 72

Technical data

25-pole D-SUB male connector

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)

8

≤ 25 V AC 50 V DC

Shield, + or – (selectable with jumper)

3.15 A

Yes - each channel

Yes - 2 female testing points dia. 4 mm

Yes - 2 female testing points dia. 4 mm

Yes

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

114 x 109 x 81

Type Order No.

RS8AIO-DP SD/V 9448010000

Type Order No.

RS8AIO/I-M-DP SD/V 9448110000

RS8AIO/I-M-DP SD/Z 9449110000

C.56

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 57: 1102340000_CAT4-5_C_EN

For Télémécanique Premium and Micro PLC analogue I/O cards

RS8AI PREM/APR – 8-channel RS8I1OA MICRO – 9-channel

8 analogue inputsVersion: screw connection

8 analogue inputs and 1 outputVersion: screw connection

Input / output for analogue cards

Screw connection

Tension clamp connection

Note

Dimensions

Ordering data

+

0+2

0- 14

1+

1- 3

127-

Inpu

t PC

B C

onne

ctor

C

C

C

C

+CS

hunt

7+

C

Shielded

1

Shunt

16

15

25

24

IC

IV

IC

IV

IC

IV

2+

2- 17

C

C

5

4

IC

IV

Connector S

ubD 25 poles

B

C

A

Sub

Dm

ale

E0+ 10

E0- 14

E2+ 11

E2-

E7-

I/O P

CB

Con

nect

or

6E7+

Shielded

S0+ 1

S0- 2

E1+ 3

E1-

10V

10V

10V

10V

10V

GND

GND

GND

GND

GND

15

Connector S

ubD 15 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Number of channels

Operating voltage

Common distribution

PLC card supply current fuse

Disconnection

Current measuring test point

Voltage measuring test point

Continuous shielding

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

25-pole D-SUB male connector

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

8

≤ 25 V AC 50 V DC

Shield, + or – (selectable with jumper)

Yes

Yes

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

116 x 87.5 x 72

Current/Voltage Switchable

Technical data

15-pole D-SUB male connector

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

9

≤ 25 V AC 50 V DC

Shielding

Yes

Yes

< 50 V AC

II

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

100 x 87.5 x 72

Type Order No.

RS8AI PREM/APR SD/V 9448030000

Type Order No.

RS8I1OA MICRO SD/V 9448040000

C.57

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C

Page 58: 1102340000_CAT4-5_C_EN

For 16-channel analogue I/O cards RS AIO-DP - 16-channel RS AIO/I-M-DP - 16-channel

Common distributionVersion: screw connection

Common distribution, disconnection and testVersion: screw / tension clamp

Input / output for analogue cards

Screw connection

Tension clamp connection

Note

Dimensions

Ordering data

-

+F+

2

21

120

0+ 3

0- 22

1+ 4

1- 23

3715-

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

C

-

+C

C

Shu

nt

1815+

C

Shielded

Connector S

ubD 37 poles

B

C

A

Sub

Dm

ale

-

+F+

2

21

120

0+ 3

0- 22

1+ 4

1- 23

3715-

I/O P

CB

Con

nect

orS

uppl

y V

olta

ge

FUS

C

C

C

C

-

+C

C

Shu

nt

1815+

C

Shielded

Disconnectableconnector

Test point

Connector S

ubD 37 poles

Connection

Connection to PLC

Connection type V (screw clamp) Flexible/Solid

Connection type Z (tension clamp) Flexible/Solid

Input-Output Data

Number of channels

Operating voltage

Common distribution

PLC card supply current fuse

Disconnection

Current measuring test point

Voltage measuring test point

Continuous shielding

Insulation coordination (EN50178)

Rated voltage

Overvoltage category

Pollution degree

Insulation test voltage

Ambient temperature

Storage temperature

Dimensions

Length A x width B x height C mm

Note

37-pole D-SUB male connector

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

16

≤ 25 V AC 50 V DC

Shield, + or – (selectable with jumper)

3.15 A

Yes

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

205 x 87.5 x 72

Technical data

37-pole D-SUB male connector

0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)

0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)

16

≤ 25 V AC 50 V DC

Shield, + or – (selectable with jumper)

3.15 A

Yes - each channel

Yes - 2 female testing points dia. 4 mm

Yes - 2 female testing points dia. 4 mm

Yes

< 50 V AC

III

2

0.5 KV DC

-25…50 ºC

-40…60 ºC

197 x 109 x 81

Type Order No.

RS16AIO-DP SD/V 9448020000

Type Order No.

RS16AIO/I-M-DP SD/V 9448120000

RS16AIO/I-M-DP SD/Z 9449120000

C.58

PLC

Inte

rfac

esH

-, R

- an

d S

-Sys

tem

C