1100 Series 1104A-44TG2 Diesel Engine – ElectropaK
Transcript of 1100 Series 1104A-44TG2 Diesel Engine – ElectropaK
Photographs are for illustrative purposes only and may not reflect final specification.
All information in this document is substantially correct at time of printing and may be altered subsequently. Publication No. PN1784/09/12 Produced in England ©2012 Perkins Engines Company Limited
1100 Series 1104A-44TG2 Diesel Engine – ElectropaK
79.1 kWm at 1500 rpm 90.2 kWm at 1800 rpm
Building upon Perkins proven reputation within the power generation industry, the 1100 Series range of ElectropaK engines now fit even closer to customers needs.
In the world of power generation success is only gained by providing more for less. With the 1104A-44TG2 Perkins has engineered even higher levels of reliability, yet lowered the cost of ownership.
1100A units are designed for territories that do not require compliance to EPA or EU emissions legislation. These units are able to meet TA luft legislation.
Compact, efficient powerl 1100 Series is the result of an intensive period of customer
research that has guided the development of the range
l The new 4.4 litre cylinder block ensures bore roundness is maintained under the pressures of operation. It also ensures combustion and mechanical noise is lowered
l A new cylinder head has re-established Perkins mastery of air control
Quality by designl Product design and Class A manufacturing improvements
enhance product reliability while maintaining Perkins legendary reputation for durability
Cost effective powerl Compact size and low noise
l Lower fuel consumption and oil use
l 500 hour service intervals
l 2 year warranty
Product supportl Perkins actively
pursues product support excellence by ensuring our distribution network invest in their territory – strengthening relationships and providing more value to you, our customer
l Through an experienced global network of distributors and dealers, fully trained engine experts deliver total service support around the clock, 365 days a year. They have a comprehensive suite of web based tools at their fingertips covering technical information, parts identification and ordering systems, all dedicated to maximising the productivity of your engine
l Throughout the entire life of a Perkins engine, we provide access to genuine OE specification parts and service. We give 100% reassurance that you receive the very best in terms of quality for lowest possible cost .. wherever your Perkins powered machine is operating in the world
The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS5514/1. Derating may be required for conditions outside these; consult Perkins Engines Company Limited.
Generator powers are typical and are based on an average alternator efficiency and a power factor (cos. q) of 0.8. Fuel specification: BS 2869: Part 2 1998 Class A2 or DIN EN 590. Lubricating oil: 15W40 to API CG4.
Rating Definitions Prime Power: Variable load. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hours of operation. Standby Power: Variable load. Limited to 500 hours annual usage, up to 300 hours of which may be continuous running. No overload is permitted.
Engine Speed(rev/min)
Type of Operation
Typical GeneratorOutput (Net)
Engine Power
Gross Net
kVA kWe kWm bhp kWm bhp
1500 Prime Power 80.0 64.0 73.4 98.4 71.9 96.4
Standby Power 88.0 70.4 80.7 108.2 79.1 106.1
1800 Prime Power 91.3 73.0 84.5 113.3 82.0 109.9
Standby Power 100.3 80.3 93.0 124.7 90.2 121.0
Photographs are for illustrative purposes only and may not reflect final specification.
All information in this document is substantially correct at time of printing and may be altered subsequently. Publication No. PN1784/09/12 Produced in England ©2012 Perkins Engines Company Limited
Perkins Engines Company LimitedPeterborough PE1 5FQ United Kingdom Telephone +44 (0)1733 583000 Fax +44 (0)1733 582240www.perkins.com
1100 Series 1104A-44TG2 Diesel Engine – ElectropaK
79.1 kWm at 1500 rpm 90.2 kWm at 1800 rpm
Standard ElectropaK specification
Air inletl Mounted air filter
Fuel systeml Rotary type pumpl Ecoplus fuel filter
Lubrication systeml Wet sump with filler and dipstickl Spin-on oil filter
Cooling systeml Thermostatically controlled system with gear-driven
circulation pump and belt-driven pusher fanl Mounted radiator and piping
Electrical equipmentl 12 volt starter motor and 12 volt 65 amp alternator with DC
outputl 12 volt shutdown solenoid energised to run
Flywheel and housingl High inertia flywheel to SAE J620 Size 10/111⁄2l SAE 3 flywheel housing
Mountingsl Front engine mounting bracket
Literaturel User’s Handbook
Optional equipmentl Woodward electronic governor (LCG2)l Workshop manuall Parts book
Fuel Consumption
Engine Speed1500 rev/min 1800 rev/min
g/kWh l/hr g/kWh l/hr
110% of Prime Power 4.5 20.5 5.3 24.4
100% of Prime Power 4.1 18.7 4.9 22.3
75% of Prime Power 3.0 14.0 3.7 16.9
50% of Prime Power 2.1 9.7 2.6 11.9
General dataNumber of cylinders ........................................... 4 vertical in-lineBore and stroke ....................................................105 x 127 mmDisplacement ................................................................ 4.4 litresAspiration ..............................................................TurbochargedCycle ..............................................................................4 strokeCombustion system ..............................................Direct injectionCompression ratio .......................................................... 17.25:1Rotation ...............................Anti-clockwise viewed from flywheelCooling system .......................................................Water-cooledTotal lubrication system capacity.................................... 8.0 litresTotal coolant capacity .................................................. 13.0 litresDimensions – Length .................................................. 1241 mm Width ...................................................... 629 mm Height ..................................................... 951 mmDry weight (approx.) ......................................................... 463 kgFinal weight and dimensions will depend on completed specification
1241 mm
1046 mm
629 mm
951 mm
Document : DS272A/1issue 000 date 11/10/2013
Electrical CharacteristicsFrequency Hz 50 60
Voltage (series star) V 380 400 415 440 415 440 460 480
Rated power class H kVA 85 85 85 70 95 102 102 102
kW 68 68 68 56 76 81,6 81,6 81,6
Rated power class F kVA 77 77 77 63 85,5 92 92 92
kW 61,6 61,6 61,6 50,4 68,4 73,6 73,6 73,6
Regulation with DSR ±1 % with any power factor and speed variations between -5% +30%
Insulation class H
Execution Brushless
Stator winding 12 ends
Rotor with damping cage
Efficiencies class H 4/4 % 91,4 91,5 91,2 91 92,7 93,2 93,3 93,4
(see graph. for details) 3/4 % 91,6 91,9 91,8 91,5 93,3 93,5 93,6 93,8
2/4 % 89,9 90 90 89,8 91,5 91,6 91,7 91,8
1/4 % 86,2 86 85,8 85,8 87,7 87,7 87,7 87,5
Reactances (f. l.cl. F) Xd % 360,1 325 301,9 221,2 404,9 386,8 353,9 325
Xd' % 24,7 22,3 20,7 15,2 27,8 26,5 24,3 22,3
Xd" % 8,2 7,4 6,9 5,0 9,2 8,8 8,1 7,4
Xq % 188,9 170,5 158,4 116,0 212,4 202,9 185,6 170,5
Xq' % 188,9 170,5 158,4 116,0 212,4 202,9 185,6 170,5
Xq" % 32,7 29,5 27,4 20,1 36,8 35,1 32,1 29,5X2 % 21,3 19,2 17,8 13,1 23,9 22,8 20,9 19,2X0 % 4,0 3,6 3,3 2,5 4,5 4,3 3,9 3,6
Short Circuit Ratio Kcc 0,45 0,50 0,62 1,07 0,35 0,40 0,45 0,50
Time Constants Td' sec. 0,04192
Td" sec. 0,00575
Tdo' sec. 1,50Tα sec. 0,0154
Short Circuit Current Capacity % >300 >350
Excitation at no load Amp. 0,4 0,5 0,7 1 0,2 0,3 0,4 0,7
Excitation at full load Amp. 2,2 2,3 2,5 2,8 1,9 2 2,1 2,2
Overload (long-term) % 1 hour in a 6 hours period 110% rated load
Overload per 20 sec. % 300
Stator Winding Resistance (20°C) Ω 0,03
Rotor Winding Resistance (20°C) Ω 2,477
Exciter Resistance (20 °C) Ω Rotor : 0,410 Stator : 15,28
Heat dissipation at f.l.cl.H W 6398 6317 6561 5538 5985 5954 5860 5766
Telephone Interference THF < 2% TIF < 40
Radio interferenceWaveform Distors.(THD) at f. load LL/LN % 1,6 / 1,8
Waveform Distors.(THD) at no load LL/LN % 2,9 / 3
Mechanical characteristicsProtection IP 21 ( other protection on request )
DE bearing 6314.2RS
NDE bearing 6311.2RS
Weight of wound stator assembly kgWeight of wound rotor assembly kg 63
Weight of complete generator kgMaximun overspeed rpm 2250
Unbalanced magnetic pull at f.l.cl.F kN/mm 4,9
Cooling air requirement m³/min 19,3 23
Inertia Constant (H) sec. 0,111 0,133Noise level at 1m/7m dB(A) 79 / 65 83 / 69
This document is a propriety of Mecc Alte S.p.a..All rights reserved.
EN61000-6-3, EN61000-6-2. For others standards apply to factory
GENERATOR TYPE ECP 34-1S/4 A
All technical data are to be considered as a reference and they can be modified without any notice.
97
331
Document : DS272A/2issue 000 date : 11/11/2013
This document is a propriety of Mecc Alte S.p.a.. All rights reserved.
GENERATOR TYPE ECP 34-1S/4 A
50 Hz
85
86
87
88
89
90
91
92
93
94
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1
Effi
cien
cy %
Load p.u.
380/50
0,8 p.f.
1 p.f.
85
86
87
88
89
90
91
92
93
94
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1
Effi
cien
cy %
Load p.u.
1 p.f.
0,8 p.f.
400/50
85
86
87
88
89
90
91
92
93
94
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1
Effi
cien
cy %
Load p.u.
1 p.f.
0,8 p.f.
85
86
87
88
89
90
91
92
93
94
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1
Effi
cien
cy %
Load p.u.
1 p.f.
0,8 p.f.
0
10
20
30
40
0 1 2 3 4
Vol
tage
dip
%
380/50
Current p.u.
0,8 p.f.
1 p.f.
0 p.f.
0
10
20
30
40
0 1 2 3 4
Vol
tage
dip
%
Current p.u.
400/50
0 p.f.
0,8 p.f.
1 p.f.
0
10
20
30
40
0 1 2 3 4
Vol
tage
dip
%
Current p.u.
0 p.f.
0,8 p.f.
1 p.f.
415/50
440/50
415/50
0
10
20
30
0 1 2 3 4
Vol
tage
dip
%
Current p.u.
0 p.f.
0,8 p.f.
1 p.f.
1
10
100
1000
10000
0,001 0,01 0,1 1 10
Am
pere
s
Three phase short circuit decrement curve. No load excitation at rated speed
Seconds
Asymmetrical
Symmetrical
440/50
Document : DS272A/3issue 000 date : 11/11/2013
This document is a propriety of Mecc Alte S.p.a.. All rights reserved.
GENERATOR TYPE ECP 34-1S/4 A
60 Hz
87
88
89
90
91
92
93
94
95
96
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1
Effi
cien
cy %
Load p.u.
415/60
0,8 p.f.
1 p.f.
87
88
89
90
91
92
93
94
95
96
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1
Effi
cien
cy %
Load p.u.
1 p.f.
0,8 p.f.
440/60
87
88
89
90
91
92
93
94
95
96
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1
Effi
cien
cy %
Load p.u.
1 p.f.
0,8 p.f.
87
88
89
90
91
92
93
94
95
96
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1
Effi
cien
cy %
Load p.u.
1 p.f.
0,8 p.f.
0
10
20
30
40
50
0 1 2 3 4
Vol
tage
dip
%
415/60
Current p.u.
0,8 p.f.
1 p.f.
0 p.f.
0
10
20
30
40
50
0 1 2 3 4
Vol
tage
dip
%
Current p.u.
440/60
0 p.f.
0,8 p.f.
1 p.f.
0
10
20
30
40
0 1 2 3 4
Vol
tage
dip
%
Current p.u.
0 p.f.
0,8 p.f.
1 p.f.
460/60
480/60
460/60
0
10
20
30
40
0 1 2 3 4
Vol
tage
dip
%
Current p.u.
0 p.f.
0,8 p.f.
1 p.f.
1
10
100
1000
10000
0,001 0,01 0,1 1 10
Am
pere
s
Three phase short circuit decrement curve. No load excitation at rated speed
Seconds
Asymmetrical
Symmetrical
480/60
UCI224G - Technical Data Sheet
UCI224GSPECIFICATIONS & OPTIONS
STANDARDSNewage Stamford industrial generators meet therequirements of BS EN 60034 and the relevant sectionof other international standards such as BS5000, VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.
VOLTAGE REGULATORS
SX460 AVR - STANDARDWith this self excited control system the main statorsupplies power via the Automatic Voltage Regulator(AVR) to the exciter stator. The high efficiencysemiconductors of the AVR ensure positive build-upfrom initial low levels of residual voltage.The exciter rotor output is fed to the main rotor througha three phase full wave bridge rectifier. This rectifier isprotected by a surge suppressor against surgescaused, for example, by short circuit.
SX440 AVRWith this self-excited system the main stator providespower via the AVR to the exciter stator. The highefficiency semi-conductors of the AVR ensure positivebuild-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor througha three-phase full-wave bridge rectifier. The rectifier isprotected by a surge suppressor against surgescaused, for example, by short circuit or out-of-phaseparalleling.The SX440 will support a range of electronicaccessories, including a 'droop' Current Transformer(CT) to permit parallel operation with other acgenerators.If 3-phase sensing is required with the self-excitedsystem, the SX421 AVR must be used.
SX421AVRThis AVR also operates in a self-excited system. Itcombines all the features of the SX440 with,additionally, three-phase rms sensing for improvedregulation and performance. Over voltage protection isprovided via a separate circuit breaker. An engine reliefload acceptance feature is built in as standard.
MX341 AVRThis sophisticated AVR is incorporated into theStamford Permanent Magnet Generator (PMG) controlsystem.The PMG provides power via the AVR to the mainexciter, giving a source of constant excitation powerindependent of generator output. The main exciteroutput is then fed to the main rotor, through a full wavebridge, protected by a surge suppressor. The AVR hasin-built protection against sustained over-excitation,caused by internal or external faults. This de-excitesthe machine after a minimum of 5 seconds.An engine relief load acceptance feature can enable fullload to be applied to the generator in a single step.If three-phase sensing is required with the PMG systemthe MX321 AVR must be used.We recommend three-phase sensing for applicationswith greatly unbalanced or highly non-linear loads.
MX321 AVRThe most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally, three-phaserms sensing, for improved regulation and performance.Over voltage protection is built-in and short circuitcurrent level adjustments is an optional facility.
WINDINGS & ELECTRICAL PERFORMANCEAll generator stators are wound to 2/3 pitch. Thiseliminates triplen (3rd, 9th, 15th …) harmonics on thevoltage waveform and is found to be the optimumdesign for trouble-free supply of non-linear loads. The2/3 pitch design avoids excessive neutral currentssometimes seen with higher winding pitches, when inparallel with the mains. A fully connected damperwinding reduces oscillations during paralleling. Thiswinding, with the 2/3 pitch and carefully selected poleand tooth designs, ensures very low waveformdistortion.
TERMINALS & TERMINAL BOXStandard generators are 3-phase reconnectable with 12ends brought out to the terminals, which are mountedon a cover at the non-drive end of the generator. Asheet steel terminal box contains the AVR and providesample space for the customers' wiring and glandarrangements. It has removable panels for easyaccess.
SHAFT & KEYSAll generator rotors are dynamically balanced to betterthan BS6861:Part 1 Grade 2.5 for minimum vibration inoperation. Two bearing generators are balanced with ahalf key.
INSULATION/IMPREGNATIONThe insulation system is class 'H'.All wound components are impregnated with materialsand processes designed specifically to provide the highbuild required for static windings and the highmechanical strength required for rotating components.
QUALITY ASSURANCEGenerators are manufactured using productionprocedures having a quality assurance level to BS ENISO 9001.
The stated voltage regulation may not be maintained inthe presence of certain radio transmitted signals. Anychange in performance will fall within the limits ofCriteria 'B' of EN 61000-6-2:2001. At no time will thesteady-state voltage regulation exceed 2%.
NB Continuous development of our products entitles usto change specification details without notice, thereforethey must not be regarded as binding.
Front cover drawing typical of product range.
2
CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G.
A.V.R. MX321 MX341
VOLTAGE REGULATION ± 0.5 % ± 1.0 % With 4% ENGINE GOVERNING
SUSTAINED SHORT CIRCUIT
CONTROL SYSTEM SELF EXCITED
A.V.R. SX460 SX440 SX421
VOLTAGE REGULATION ± 1.5 % ± 1.0 % ± 0.5 % With 4% ENGINE GOVERNING
SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT
INSULATION SYSTEM CLASS H
PROTECTION
RATED POWER FACTOR
STATOR WINDING
WINDING PITCH
WINDING LEADS
STATOR WDG. RESISTANCE
ROTOR WDG. RESISTANCE
EXCITER STATOR RESISTANCE
EXCITER ROTOR RESISTANCE
R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others
WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%
MAXIMUM OVERSPEED
BEARING DRIVE END
BEARING NON-DRIVE END
WEIGHT COMP. GENERATOR
WEIGHT WOUND STATOR
WEIGHT WOUND ROTOR
WR² INERTIA
SHIPPING WEIGHTS in a crate
PACKING CRATE SIZE
TELEPHONE INTERFERENCE
COOLING AIR
VOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277
VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138
VOLTAGE SERIES DELTA 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138kVA BASE RATING FOR REACTANCE VALUES
85 85 85 79 93.8 97.5 100 103.8
Xd DIR. AXIS SYNCHRONOUS 2.43 2.20 2.04 1.69 2.66 2.47 2.32 2.21
X'd DIR. AXIS TRANSIENT 0.19 0.17 0.16 0.13 0.20 0.19 0.17 0.17
X''d DIR. AXIS SUBTRANSIENT 0.13 0.12 0.11 0.09 0.14 0.13 0.12 0.12
Xq QUAD. AXIS REACTANCE 1.12 1.01 0.94 0.78 1.22 1.13 1.06 1.01
X''q QUAD. AXIS SUBTRANSIENT 0.17 0.15 0.14 0.12 0.15 0.14 0.13 0.12
XL LEAKAGE REACTANCE 0.07 0.06 0.06 0.05 0.08 0.07 0.07 0.07
X2 NEGATIVE SEQUENCE 0.16 0.14 0.13 0.11 0.15 0.14 0.13 0.12
X0 ZERO SEQUENCE 0.11 0.10 0.09 0.07 0.11 0.10 0.10 0.09
REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATEDT'd TRANSIENT TIME CONST.T''d SUB-TRANSTIME CONST.T'do O.C. FIELD TIME CONST.Ta ARMATURE TIME CONST.
SHORT CIRCUIT RATIO
20 Ohms at 22°C
0.078 Ohms PER PHASE AT 22°C
REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7)
BALL. 6309-2RS (ISO)
0.94 Ohms at 22°C
0.055 Ohms PER PHASE AT 22°C SERIES STAR CONNECTED
BALL. 6312-2RS (ISO)
1/Xd
0.03 s0.008 s0.75 s0.007 s
126.75 kg
0.7136 kgm2
IP23
0.8
DOUBLE LAYER CONCENTRIC
TWO THIRDS
12
400 kg383 kg
139 kg
UCI224G
0.216 m³/sec 458 cfm 0.281 m³/sec 595 cfm
50 Hz
THF<2%
60 Hz
TIF<50
118.38 kg
0.6818 kgm2
WINDING 311
1 BEARING 2 BEARING
2250 Rev/Min
139 kg
420 kg
105 x 57 x 96(cm)
404 kg
105 x 57 x 96(cm)
3
Winding 311UCI224G
THREE PHASE EFFICIENCY CURVES
50Hz
4
Winding 311UCI224G
THREE PHASE EFFICIENCY CURVES
60Hz
5
UCI224GWinding 311
Locked Rotor Motor Starting Curve
MX SX
50Hz
60Hz
MX SX
0
5
10
15
20
25
30
0 50 100 150 200 250 300LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
346V 380V 400V 415V 440V
0
5
10
15
20
25
30
0 50 100 150 200 250LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
346V 380V 400V 415V 440V
0
5
10
15
20
25
30
0 50 100 150 200 250 300 350LOCKED ROTOR kVA
PE
R C
EN
T TR
AN
SIE
NT
VO
LTA
GE
DIP
380V 416V 440V 460V 480V
0
5
10
15
20
25
30
0 50 100 150 200 250 300LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
380V 416V 440V 460V 480V
6
3-phase 2-phase L-L 1-phase L-NVoltage Factor Voltage Factor x 1.00 x 0.87 x 1.30
380v X 1.00 416v X 1.00 x 1.00 x 1.80 x 3.20400v X 1.07 440v X 1.06 x 1.00 x 1.50 x 2.50415v X 1.12 460v X 1.12 10 sec. 5 sec. 2 sec.440v X 1.18 480v X 1.17
UCI224G
50Hz 60Hz
The sustained current value is constant irrespectiveof voltage level
Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated SpeedBased on star (wye) connection.
Max. sustained durationAll other times are unchanged
Instantaneous
SustainedMinimum
Sustained Short Circuit = 390 Amps
Sustained Short Circuit = 460 AmpsNote 1The following multiplication factors should beused to adjust the values from curve betweentime 0.001 seconds and the minimum currentpoint in respect of nominal operating voltage :
Note 2The following multiplication factor should be used to convert thevalues calculated in accordance with NOTE 1 to those applicableto the various types of short circuit :
Note 3Curves are drawn for Star (Wye) connected machines. For otherconnection the following multipliers should be applied to currentvalues as shown : Parallel Star = Curve current value X 2Series Delta = Curve current value X 1.732
50Hz
60Hz
10
100
1000
10000
0.001 0.01 0.1 1 10TIME (secs)
CU
RR
EN
T (A
mp
s)
SYMMETRICAL
ASYMMETRICAL
100
1000
10000
0.001 0.01 0.1 1 10TIME (secs)
CU
RR
EN
T (A
mp
s)
SYMMETRICAL
ASYMMETRICAL
7
Class - Temp Rise
Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440
Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220
Series Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254
kVA 75.0 75.0 75.0 67.4 85.0 85.0 85.0 75.0 87.5 87.5 87.5 76.9 90.8 90.8 90.8 80.1
kW 60.0 60.0 60.0 53.9 68.0 68.0 68.0 60.0 70.0 70.0 70.0 61.5 72.6 72.6 72.6 64.1
Efficiency (%) 90.3 90.6 90.7 91.0 89.8 90.2 90.4 90.8 89.7 90.1 90.3 90.7 89.6 89.9 90.1 90.6
kW Input 66.4 66.2 66.2 62.4 75.7 75.4 75.2 69.6 78.0 77.7 77.5 71.4 81.1 80.8 80.6 74.5
Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480
Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240
Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277
kVA 87.5 90.0 93.8 95.0 93.8 97.5 100.0 103.8 98.1 102.5 102.5 110.0 101.3 106.3 106.3 113.8
kW 70.0 72.0 75.0 76.0 75.0 78.0 80.0 83.0 78.5 82.0 82.0 88.0 81.0 85.0 85.0 91.0
Efficiency (%) 90.8 91.0 91.1 91.3 90.5 90.8 90.9 91.0 90.3 90.6 90.9 90.9 90.2 90.4 90.7 90.8
kW Input 77.1 79.1 82.4 83.2 82.9 85.9 88.0 91.3 86.9 90.5 90.2 96.8 89.8 94.1 93.8 100.3
TD_UCI224G.GB_12.03_04_GB
Cont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C
DIMENSIONS
UCI224GWinding 311 / 0.8 Power Factor
RATINGS
Barnack Road • Stamford • Lincolnshire • PE9 2NBTel: 00 44 (0)1780 484000 • Fax: 00 44 (0)1780 484100Website: www.newage-avkseg.com
© 2004 Newage International Limited.Reprinted with permission of N.I. only.Printed in England.
50Hz
60Hz