11 Single Site Verification

download 11 Single Site Verification

of 37

Transcript of 11 Single Site Verification

  • 8/6/2019 11 Single Site Verification

    1/37

    www.huawei.com

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Single Site Verification

  • 8/6/2019 11 Single Site Verification

    2/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Foreword

    Single site verification is the first step of optimization

    Single site verification confirm the working state of each site

  • 8/6/2019 11 Single Site Verification

    3/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Objectives

    Upon completion of this course, you will be able to:

    Know the steps of single site verification

    Know how to do single site verification

    Know how to solve the ordinary problems in single site

    verification

  • 8/6/2019 11 Single Site Verification

    4/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Contents

    Preparation of Single Site Verification

    Test Content of Single Site Verification

    Typical Problems Analysis in Single Site Verification

  • 8/6/2019 11 Single Site Verification

    5/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Preparation of Single Site Verification

    Site state check

    Check the site state by RNC LMT or M2000

    DSP CELL

  • 8/6/2019 11 Single Site Verification

    6/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Preparation of Single Site Verification

    Site state check

    Result

  • 8/6/2019 11 Single Site Verification

    7/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Preparation of Single Site Verification

    Configuration data collection

    RNC Configuration file collection

    Without parameters, the file will be saved at FTP directory under

    BAM main path and file name can be specified by user, default

    CFGMML-YearMonthDateHourMinSec.txt.

  • 8/6/2019 11 Single Site Verification

    8/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Preparation of Single Site Verification

    Configuration data collection

    RNC configuration parameter checking by GENEX

    Nastar

    NODEBNAME

    LOCELL ID

    MAXTXPOWER

    LAC

    RAC Scramble PSCRAMBCODE

    Frequency UARFCNDOWNLINK

  • 8/6/2019 11 Single Site Verification

    9/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Preparation of Single Site Verification

    Test location and route choose principle

    The right test point meeting the following conditions:

    Where the signals of target cell are strong

    Where the signals of other cells are weak

  • 8/6/2019 11 Single Site Verification

    10/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Preparation of Single Site Verification

    Test location and route choose principle

    For better performance, the following methods can be

    taken:

    Disable power amplifiers of other cells except the cell to

    be measured

    If cannot disable other cells, the testing point should be

    near the center of the cell, with line-of-sight distance to

    the NodeB

    For a macro cell, testing point should be less than 100

    meters from NodeB in the direction of major beam of cell

    antenna, with line-of-sight distance to NodeB.

  • 8/6/2019 11 Single Site Verification

    11/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Contents

    Preparation of Single Site Verification

    Test Content of Single Site Verification

    Typical Problems Analysis in Single Site Verification

  • 8/6/2019 11 Single Site Verification

    12/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    Verification in Idle Mode

    Frequency Check

    Downlink frequency channel number = DL Frequency * 5

    For example

    UE shows the DL frequency is 2117.40

    The DL frequency point number is 10587

  • 8/6/2019 11 Single Site Verification

    13/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    Verification in Idle Mode

    Cell ID Check

    Check whether the LAC/RAC of the cell to be measured is consistent

    with the planed one

  • 8/6/2019 11 Single Site Verification

    14/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    Verification in Idle Mode

    Scrambling code Check

    At the right place, UE will show

    PSC in active set, including the signal level

    PSC in monitor set, including the signal level

  • 8/6/2019 11 Single Site Verification

    15/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    Verification in Idle Mode

    LAC/RAC Check

    Check whether the LAC/RAC of the cell to be measured is consistent

    with the planed one

  • 8/6/2019 11 Single Site Verification

    16/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    Verification in Idle Mode

    CPICH_RSCP/CPICH_EcIo (Near Site) Test

    Method

    In the major transmission direction of antenna, fix a location with line-of-

    sight distance from the antenna within 100 meters from the NodeB

    Test UE shows the signal level, including RSCP and Ec/Io

    Bench Mark Value

    For macro cells, CPICH RSCP > 75 dBm

    For micro cells, CPICH RSCP > 60 dBm

    For no-load cells, CPICH Ec/Io > 8 dB

    For load-on cells, CPICH Ec/Io > 10 dB

  • 8/6/2019 11 Single Site Verification

    17/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    Verification in Connected Mode

    Originating and Terminating Connection Test of Voice

    Service

    Method

    Use two handsets to call each other for five times.

    Record the originating and terminating connection conditions

  • 8/6/2019 11 Single Site Verification

    18/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    Verification in Connected Mode

    Originating and Terminating Connection Test of VP Service

    Method

    Use two handsets to call each other for five times.

    Record the originating and terminating connection conditions

  • 8/6/2019 11 Single Site Verification

    19/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    Verification in Connected Mode

    Connection Test of PS Services

    Method

    Originating function of PS services by handset online service

    Pay attention to the throughput

  • 8/6/2019 11 Single Site Verification

    20/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    Drive Test for Coverage of the Site

    Method

    Prepare the NodeB location map

    need to cover major streets around the NodeB

    Output area coverage map based on the pilot signals received by

    scanner

    Compare the CPICH RSCP and Ec/Io distribution of each cell

  • 8/6/2019 11 Single Site Verification

    21/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    HSDPA Access Function Test

    Preparation for HSDPA Test

    Check defined downlink rate of the test USIM card

    Check the related HSDPA parameters in RNC configuration file with

    LSTFRCand ensure USIM card subscribe rate is equal or greater

    DlBeTraffDecThs

    Prepare the DT software with HSDPA test function module

    Prepare the terminal with HSDPA function and category

    Huawei E870, category 8, 7.2Mbps

    Huawei E620, category 12, 1.8Mbps

    Huawei E220, category 6, 3.6Mbps

  • 8/6/2019 11 Single Site Verification

    22/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    HSDPA Access Function Test

    Method

    Origination high speed downloading service, such FTP

    download

  • 8/6/2019 11 Single Site Verification

    23/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    Antenna Diversity Check

    Objectivity

    Check whether the antenna for receiving diversity signals is

    reversely connected

  • 8/6/2019 11 Single Site Verification

    24/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    Antenna Diversity Check

    Method 1

    In the cell to be measured, set UE transmits signals with the fixed

    maximum power

    Check the RTWP of the cell to be measured and the neighbor cells

    If the RTWP of the corresponding cell increases only and the RTWP of

    neighbor sectors changes less, the diversity receiver antenna is correctly

    connected

    If the RTWP of corresponding cell and other sectors increases at the

    same time, the diversity receiver antenna is improperly connected

  • 8/6/2019 11 Single Site Verification

    25/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Test Content of Single Site Verification

    Antenna Diversity Check

    Method 2

    Connect the Tx/Rx feeder to the Rx ports and the Rx feeder to the

    Tx/Rx port.

    Compare the CPICH RSCP before and after exchanging feeders.

    If the difference of CPICH RSCP before and after exchanging feeders is

    more than 20 dB, the diversity receiver antenna is improperly connected

  • 8/6/2019 11 Single Site Verification

    26/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Contents

    Preparation of Single Site Verification

    Test Content of Single Site Verification

    Typical Problems Analysis in Single Site Verification

  • 8/6/2019 11 Single Site Verification

    27/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Weak Coverage Problem Analysis Phenomenon

    In single site verification drive test, the signal level is very

    bad in 200m with line-of-sight

    No blocking

    Analysis Check the alarm information (VSWR) no alarm

    Check the feeder system

    Downtilt angle OK

    Azimuth OK

    Connector OK

  • 8/6/2019 11 Single Site Verification

    28/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Weak Coverage Problem Analysis

    Analysis

    Check configuration file

    The parameters related to CPICH power OK

    33dBm, and the maximum transmission power for the cell 20W.

  • 8/6/2019 11 Single Site Verification

    29/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Weak Coverage Problem Analysis

    Analysis

    Check the output power of the cell

  • 8/6/2019 11 Single Site Verification

    30/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Weak Coverage Problem Analysis

    Analysis Check the output power of the cell

  • 8/6/2019 11 Single Site Verification

    31/37

  • 8/6/2019 11 Single Site Verification

    32/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Antenna Diversity Problem Analysis

    In single site verification, antenna receiving diversity should be

    checked

    Phenomenon

    Without subscriber, the RTWP test shows

  • 8/6/2019 11 Single Site Verification

    33/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Antenna Diversity Problem Analysis

    Phenomenon Set the UE with maximum transmission power in 10111, the cell

    10111 and 10112 RTWP increased at the same time,

  • 8/6/2019 11 Single Site Verification

    34/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Antenna Diversity Problem Analysis

    Phenomenon

    Set the UE with maximum transmission power in 10112, same

    problem happened

    Result The receiving diversity antenna of cell 10111 and 10112 are

    connected crossly.

    Adjustment

    Exchange the receiving diversity antenna of these two cells

  • 8/6/2019 11 Single Site Verification

    35/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Antenna Diversity Problem Analysis

    Re-test Set the UE with the maximum transmission power in Cell 10111,

    check the RTWP of 10111 and 10112, only the RTWP of 10111

    increased, the problem was resolved

  • 8/6/2019 11 Single Site Verification

    36/37

    HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

    Summary

    Single site verification

    Preparation

    Test contents

    Typical problems analysis

  • 8/6/2019 11 Single Site Verification

    37/37

    Thank youwww.huawei.com