CONDITION MONITORING
ON-LINE AUTOMATICO ANALISYS &DIAGNOSIS
STRUCTURAL INTEGRITY
Laboratorio de Vibraciones y Mecatrnica
Centro Atmico Bariloche
Comisin Nacional de Energa Atmica
Repblica Argentina
-
7/31/2019 1.1 Optimization on maint program
2/28
The Vibration & Mechatronics Laboratory inthe Bariloche Atomic Center was created in1984 as a part of the National Atomic EnergyAgency, Argentina. It is also a part of theBalseiro Institute academic & research group.
Our lab has provided solutions to industrialvibrations problems in nuclear and otherpower plants for the past 30 years
The laboratory testing capabilities are wideand varied. Additionally we have activeinteraction with academia, nuclear facilitiesand main industrial clients.
Dr. Eng. Oscar Garca Peyrano
-
7/31/2019 1.1 Optimization on maint program
3/28
How does the optimization ofmaintenance works?
Automatic Analysis
& Diagnosis System SCADA
EarlyWarning
Optimal Maintenance
Life Extension
-
7/31/2019 1.1 Optimization on maint program
4/28
Machine Engineering
Operation Condition
Modeling Techniques
Experience
Simulation(Normal & Failure
Operation)
Expected Response
Benchmarks Alarm Calibration
Analysis
-
7/31/2019 1.1 Optimization on maint program
5/28
Measurments
State Matrix
A11,
11
A12,12
A22,21
A22,22
Reference Matrix
= Pattern Recognition
Multivariable Diagnosis / Multiparameter
-
7/31/2019 1.1 Optimization on maint program
6/28
Reactor Argentino N6 (RA-6)
Dynamic Analysisof Reactor Internal
Components
Motor-Pump Set
Grid, Grid Support andFuel
Piping
Decay Tank
-
7/31/2019 1.1 Optimization on maint program
7/28
Piping
Core
Decay
Tank
PrimaryCoolant CircuitPump
Reactor Internal Components
-
7/31/2019 1.1 Optimization on maint program
8/28
Grid, Grid Support & FuelModal Analisys
-
7/31/2019 1.1 Optimization on maint program
9/28
Grid, Grid Support & FuelForced response
-
7/31/2019 1.1 Optimization on maint program
10/28
Decay Tank Virtual Machine
-
7/31/2019 1.1 Optimization on maint program
11/28
Decay Tank Seismic Response
-
7/31/2019 1.1 Optimization on maint program
12/28
Life Extension- Fatigue Analisys
STRESS
DURING
OPERATION
-
7/31/2019 1.1 Optimization on maint program
13/28
-
7/31/2019 1.1 Optimization on maint program
14/28
-
7/31/2019 1.1 Optimization on maint program
15/28
On-Line Diagnosis & ConditionMonitorig
Control Room
Internet, NuclearEngineering Schools & Testing
Laboratories
Knowledge &ExpertiseExchange
-
7/31/2019 1.1 Optimization on maint program
16/28
Atucha II Reactor
(CNAII, PHWR)
-
7/31/2019 1.1 Optimization on maint program
17/28
Dynamic Compensation
Emergency Coolant Circuit Pump
1. Dynamic Compensator2. Mesure Point
-
7/31/2019 1.1 Optimization on maint program
18/28
Emergency Coolant Circuit PumpDinamic Compensation- Results
With the implementation of the dynamic compensator device, the vibration level[RMS] has been reduced from 24 mm/s to 3.2 mm/s. In this condition the machineworks with an appropriate vibration level according it size and power.
The vibration level reduction has been achieved without modifying the structuralintegrity of the machine
-
7/31/2019 1.1 Optimization on maint program
19/28
Auxiliary Systems
-
7/31/2019 1.1 Optimization on maint program
20/28
Embalse Reactor
(CNE, CANDU-6)
-
7/31/2019 1.1 Optimization on maint program
21/28
Turbine and Electric Generator
Dynamic Analisys
End Winding
Steam Turbine
-
7/31/2019 1.1 Optimization on maint program
22/28
End Winding & Stator Bars Set
Forced vibration in the End Winding: 100 and 500 Hz oscillatingforces acting on the piece, simulating the excitation of the endwinding on service.
Areas are observed with stress concentrations.
-
7/31/2019 1.1 Optimization on maint program
23/28
End Winding Stress Concentration
-
7/31/2019 1.1 Optimization on maint program
24/28
Pressure Tubes
Modal Analysis.
Interaction with garter springs.
-
7/31/2019 1.1 Optimization on maint program
25/28
Steam Generators
Heat Sink Coolant Pump
-
7/31/2019 1.1 Optimization on maint program
26/28
Heat Sink Coolant Pump
Forced response
-
7/31/2019 1.1 Optimization on maint program
27/28
Acknowledgements
Comisin Nacional de Energa Atmica
Reactor RA6
Research & DevelopmentGroup, Centro Atmico Bariloche
Nucleoelctrica Argentina SA
Industrias Metalurgicas Pescarmona SA
-
7/31/2019 1.1 Optimization on maint program
28/28
Questions?