Upgrading Power 6 system microcodeP520/550 to EL350_039
P570 to EM350_038
Login to the lpars on the managed system and check the current system firmware level.
# lsmcode -cThe current permanent system firmware image is EL340_101The current temporary system firmware image is EL340_101The system is currently booted from the temporary firmware image.
If the level is below EL350 or EM350 (On P570) then this will be a DISRUPTIVE upgrade. All lpars must be shutdown and not activated during the firmware upgrade.
Shutdown all lpars:# shutdown –FWait for: ....Halt completed....
![Page 2: 10.1 P6 Firmware Installation Procedures](https://reader035.fdocuments.in/reader035/viewer/2022081801/545f31abb1af9f04598b4bbb/html5/thumbnails/2.jpg)
Open a browser to the appropriate HMC
Check the Managed System to make sure all lpars show “Not Activated”
![Page 3: 10.1 P6 Firmware Installation Procedures](https://reader035.fdocuments.in/reader035/viewer/2022081801/545f31abb1af9f04598b4bbb/html5/thumbnails/3.jpg)
Select “Updates” in left pane and select appropriate Server. Select “Change Licensed Internal Code for current release” in Tasks (lower pane)
Select “Start Change Licensed Internal Code wizard” and click OK
Select OK at the Information window
![Page 4: 10.1 P6 Firmware Installation Procedures](https://reader035.fdocuments.in/reader035/viewer/2022081801/545f31abb1af9f04598b4bbb/html5/thumbnails/4.jpg)
Select “Removable Media”and click OK
Click OK
Click next
![Page 5: 10.1 P6 Firmware Installation Procedures](https://reader035.fdocuments.in/reader035/viewer/2022081801/545f31abb1af9f04598b4bbb/html5/thumbnails/5.jpg)
Click “Run Release…”
Select OK
![Page 6: 10.1 P6 Firmware Installation Procedures](https://reader035.fdocuments.in/reader035/viewer/2022081801/545f31abb1af9f04598b4bbb/html5/thumbnails/6.jpg)
Select “Removable Media” and press OK
Select the EC Name (01EL350) and press OK
![Page 7: 10.1 P6 Firmware Installation Procedures](https://reader035.fdocuments.in/reader035/viewer/2022081801/545f31abb1af9f04598b4bbb/html5/thumbnails/7.jpg)
Select “Power off automatically” and press OK
![Page 8: 10.1 P6 Firmware Installation Procedures](https://reader035.fdocuments.in/reader035/viewer/2022081801/545f31abb1af9f04598b4bbb/html5/thumbnails/8.jpg)
Select Accept to continue
This is the final warning. ALL LPARS MUST BE “NOT ACTIVATED”Press OK
![Page 9: 10.1 P6 Firmware Installation Procedures](https://reader035.fdocuments.in/reader035/viewer/2022081801/545f31abb1af9f04598b4bbb/html5/thumbnails/9.jpg)
Press OK
Progress window will appear
When complete the Managed System (Server) will power on automatically to Standby. You will then be ready to activate the lpar(s)
After the lpars are up:
Run lsmcode –c on one of the running lpars. You should see that the firmware has been updated
# lsmcode -cThe current permanent system firmware image is EL350_039The current temporary system firmware image is EL350_039