100mmØ uPVC DUCT LARKFIELD CHASE LARKFIELD...
Transcript of 100mmØ uPVC DUCT LARKFIELD CHASE LARKFIELD...
L
A
R
K
F
I
E
L
D
H
E
A
T
H
L
A
R
K
F
I
E
L
D
H
E
A
T
H
L
A
R
K
F
I
E
L
D
C
H
A
S
E
EX
EX
EX
X4
X4
X3
X3
X2
X2
X2
SS NO.3
M
C
P
N
o
.
1
4
N
o
.
1
1
X3
X3
S
S
N
O
.
4
C
L
I
E
N
T
E
X
T
E
R
N
A
L
C
A
B
I
N
E
T
A
T
G
R
O
U
N
D
L
E
V
E
L
C
L
I
E
N
T
E
X
T
E
R
N
A
L
C
A
B
I
N
E
T
A
T
G
R
O
U
N
D
L
E
V
E
L
E
S
B
E
S
B
M
C
P
SCHEDULE OF SYMBOLS
ESB MINI-PILLAR FOR PUBLIC LIGHTING
X1
SCHEDULE OF SYMBOLS
THORN Civi TEQ LARGE EWR 1 X 72W LED
MOUNTED ON 8M HIGH COLUMNS
1No 125mm ESB MV DUCTS
X2
THORN Civi TEQ SMALL WR 1 X 21W LED
MOUNTED ON 6M HIGH COLUMNS
NOTES
1. ALL EXTERIOR LIGHTING SHALL COMPLY WITH CODE OF PRACTICE FOR THE
DESIGN OF ROAD LIGHTING BS5489-1:2003, EN13201-2003, DUN LAOGHAIRE
RATHDOWN COUNTY COUNCIL PUBLIC LIGHTING INSTALLATION IN RESIDENTIAL
AND INDUSTRIAL AREA'S GUIDANCE DOCUMENT 2014, NATIONAL RULES FOR
ELECTRICAL INSTALLATION ET101:2008- PART 1 GENERAL REQUIRMENTS & PART
2.3 PARTICULAR REQUIRMENTS FOR PUBLIC LIGHTING INSTALLATIONS.
2. THE EXTERNAL LIGHTING LAYOUT HAS BEEN DESIGNED IN ACCORDANCE WITH BS
5489-1:2003 AND EN 13201-2003 STANDARDS
3. DUCTING SHALL COMPLY WITH BSEN 50086-1-2-3-4 LATEST EDITION & SHALL BE
SINGLE WALL, COLORED RED & MANUFACTURED FROM HIGH DENSITY
POLYPROPYLENE. THE NOMINAL EXTERNAL DIAMETER OF THE DUCT SHALL BE
107mm WITH A MINIMAL WALL THICKNESS OF 5mm. EACH LENGTH OF DUCT SHALL
BE STAMPED WITH THE WORDS "PUBLIC LIGHTING", OR ALTERNATIVELY, "STREET
LIGHTING", IN 18mm BLACK LETTERING AT 0 DEGREES, AT ONE METRE INTERVALS.
DUCT SHALL BE LAID WITH THIS LEGEND FACING UPWARDS. DUCT SHALL BE LAID
IN A STRAIGHT LINE CLOSE TO THE LINE OF THE COLUMN LOCATIONS & SHALL
CONTAIN A CONTINUOUS DRAW WIRE OF 8KN STRENGTH. ALL DUCTS SHALL BE
PROVEN WITH BRUSH AND MANDRILL, POLYPROPYLENE ROPED AND PLUGGED
AND COMPLAINT WITH ET101 REQUIREMENTS RED DUCT DUCT SHALL BE USED
FOR EXTERIORS LIGHTING CABLES.
4. A MINIMUM DEPTH OF 450mm COVER IS REQUIRED IN URBAN PATHWAYS & A
MINIMUM OF 600mm COVER IS REQUIRED FOR GRASS MARGINS, PEDESTRIAN
WAYS, LANEWAYS & GATEWAY ENTRANCES & A MINIMUM DEPTH OF 750mm IS
REQUIRED AT ROAD CROSSINGS OR IN CARRIAGEWAYS.
5. ALL CABLE DRAW INSPECTION PITS SHALL BE OF DUCTILE IRON GALVANISED
STEEL FRAME WITH FRAME OPENING OF 500mmx500mm TO CONFORM TO
EN124B125 MARKED 'PUBLIC LIGHTING' OR TRAFFIC WITH M16 STAINLESS STEEL
LOCKING BOLT. ALL CABLE DRAW INSPECTION PITS FOR USE ON CARRIAGEWAYS
SHALL BE OF THE SAME DIMENSION AS ABOVE WITH HIGH STRENGTH
ENGINEERING OR SITU CONCRETE. COVERS AND FRAMES SHALL BE APPROVED
BY LICENSED BODY NSAI OR BRITISH STANDARDS INSTITUTE OF QUALITY
ASSURANCE SERVICES.
6. ALL EQUIPMENT TO BE SUITABLY IP RATED FOR THE ENVIRONMENT THEY ARE
BEING INSTALLED.
7. LIGHT COLUMN SETBACK SHALL BE 0.8M FROM KERB IN ACCORDANCE WITH
BS5489-1 TABLE 2
MCP
MICRO PILLAR
1No 50mm ESB MV DUCTS
EX
EXISTING LUMINIARE - THORN R2L2 149W 84 LED
X3
THORN Civi TEQ SMALL EWS 1 X 38W LED
MOUNTED ON 6M HIGH COLUMNS
P1 PRELIMINARY TS RF RH 25/03/19
DRAWING TITLE
CLIENT
PROJECT
APPDESCRIPTIONREV ENGDRN DATE
01 2530710
14C The Exchange, Calmount Business Park
Ballymount,
Dublin 12
)
*
ý
www.pmep.ie
© Copyright PMEP
SCALE SHEET SIZE DRAWING No. REV.
THIS DRAWING IS THE PROPERTY OF PMEP CONSULTING SHALL NOT
BE USED, REPRODUCED OR DISCLOSED TO ANYONE WITHOUT PRIOR WRITTEN PERMISSION
OF PMEP CONSULTING & SHALL BE RETURNED UPON REQUEST.
ARCHITECT
DUBLIN
BALLYOGAN ROAD, PHASE 1C
CLAY FARM
SITE PLAN
SITE LIGHTING LAYOUT
ELECTRICAL SERVICES INSTALLATION
VISCOUNT SECURITIES
P2P021-PMEP-1C-00-DR-E-00A1
500 @ A3
250 @ A1
LIGHTING COLUMN ACCESS DOOR DETAIL
(SCALE N.T.S.)
DOOR
SECTION
DOOR FRONT
FACE
DOOR RECESS
DETAIL
DOOR RECESS
SECTION
M8 LOCK
TAP FOR M8
FOR EARTH SCREW
TAP FOR M83mm THICK
COLUMN WALL
FRAME PROJECTS
10mm IN FRONT ON
COLUMN WALL
WEATHER STRIP
38
5
90
10
6mm
6mm
40
mm
MICRO PILLAR CIRCUITRY DETAIL
(SCALE N.T.S.)
X1X1X1X1X1X1
X1X1X1X1X1
X1
X1 X1 X1 X1 X1 X1
X1 X1 X1 X1 X1 X1
MICRO PILLAR FOR PUBLIC LIGHTING
STREET/EXTERNAL LUMINAIRE
X1
NOTES:
1. A MAXIMUM OF 4No. CIRCUIT PER MICRO PILLAR
2. A MAXIMUM OF 6No. LUMINAIRE FITTINGS PER CIRCUIT
3. MICRO PILLAR MUST BE LOCATED A MINIMUM OF 2.0M AWAY FROM AN
ESB NETWORKS MINI PILLAR
4. MICRO PILLAR MUST BE LOCATED A MINIMUM OF 10.0M AWAY FROM AN
ESB NETWORKS STATION.
MICRO PILLAR DETAIL
(SCALE N.T.S.)
F.G.L.
FIXING PLATE
END VIEW ELEVATIONPLAN
150
60
03
00
150
4ON20 CONCRETE FLAG
3ON20 CONCRETE FLAG
100mmØ uPVC DUCT
CABLE ENTRY SLOT
COMPACTED BACKFILL
GROUND LEVEL
LIGHTING COLUMN
LIGHTING COLUMN
ACCESS DOOR
ADAPTOR
3 CORE 2.5mm
2
PVC/PVC CABLE
LUMINAIRE FITTING
D
A
C
2 No 50mm Flexible Ducts from
Site Lighting Duct to 1200mm
above Finished Ground Level
PUBLIC LIGHTING COLUMN DETAIL SCHEDULE
ROOT DEPTH - A
COLUMN MOUNTING HEIGHT:14M 13M
CABLE ENTRY DEPTH - B
ROOTING CONCRETE DEPTH - C
HEIGHT OF COLUMN DOOR - D
2.0M
0.3M
1.3M
12M 10M 8.0M 6.0M
2.0M
0.3M
1.3M
1.7M
0.3M
1.0M
1.5M
0.3M
0.8M
1.2M
0.3M
0.7M
1.0M
0.3M
0.5M
1.5M1.5M1.5M1.5M1.5M1.5M
NOTES:
1. STEEL TO BS4360 GRADE 43 C (min thickness is 3mm)
2. BITUMINOUS PRESERVATION TO COVER PLANTING DEPTH TO COVER
PLANTING DEPTH AND TO EXTEND TO 250mm ABOVE GROUND LEVEL
(1250mm IN TOTAL)
3. BOTTOM OF THE DOOR OPENING TO BE 1300mm ABOVE GROUND LEVEL
LIGHTING COLUMN DETAIL
(SCALE N.T.S.)
X4
THORN Civi TEQ SMALL PWC 1 X 15W LED
MOUNTED ON 6M HIGH COLUMNS
Ø50mm PVC CONDUIT CONCEALED UNDERGROUND
P2 PRELIMINARY JZ RF RH 16/04/19