10.0 Class 1 and 2 Repairs and Replacements As required by ASME Section XI 1989 Edition, with No Addenda, a record (Form NIS-2) of Class 1 and 2 Repairs and Replacements for work performed is included in this section of the report. Due to station processing and approval time frames, three categories of repair and replacement documentation exist for: 1) work performed during a prior refueling cycle; 2) work performed during the current refueling cycle; and 3) work completed but documentation not yet reviewed and approved. This report contains items for categories 1 and 2 only. Category 3 items will be submitted in a future report. The individual work request documents and manufacturers' data reports are on file at Catawba Nuclear Station. Refueling Outage EOC 12 (Outage 4) Catawba Unit 1 Section 10 Page 1 of 1 Revision 0 February 7, 2001

Transcript of 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129...

Page 1: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

10.0 Class 1 and 2 Repairs and Replacements

As required by ASME Section XI 1989 Edition, with No Addenda, a record (Form

NIS-2) of Class 1 and 2 Repairs and Replacements for work performed is

included in this section of the report. Due to station processing and approval

time frames, three categories of repair and replacement documentation exist for:

1) work performed during a prior refueling cycle; 2) work performed during the

current refueling cycle; and 3) work completed but documentation not yet

reviewed and approved. This report contains items for categories 1 and 2 only.

Category 3 items will be submitted in a future report.

The individual work request documents and manufacturers' data reports are on

file at Catawba Nuclear Station.

Refueling Outage EOC 12 (Outage 4) Catawba Unit 1 Section 10

Page 1 of 1 Revision 0 February 7, 2001

Page 2: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 06/19/00

Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006 2. plant CATAWBA NUCLEAR STATION 2a Unit [ 1 E

Address 4800 CONCORD RD. YORK, S.C. 29745 3. Work Performed By Duke Power Company 3a Work Order # 970S

Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE

Expiration Date N/A 4 Identification of System Class C

BB STEAM GERATOR BLOWDOWN SYSTEM 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE • A; l rtan÷G-tlr~ Afr'nmnnnantc• Pon~ir~cd n Ro~n1Aco~ment Comnonents

Section E Exhibit A

Sheet 1 of 1

]2 E-] 3 R Shared (specify Units[] )

93101-01/14

9154

Column I Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

Number (yes or no)

A Valve Walworth C62401 895 Valve tag #1KC466 1976 REPLACED

B Valve Fisher 4153B-01B 369 Valve tag #1KC466 1998 REPLACEM

C Pipe Duke Power C-1KC 129 4" Pipe-SA106, Pipe welds- 1KC12- REPLACEM

Co. 1,11, 2KC37-19

D Bolting Rod- SA193, Nuts-SA194 REPLACEM

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 3: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

Form NIS-2 (Back)kSME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets

is recorded at the top of this form.

7. Description of Work Replace Valve 1 KC466_

8. Test Conducted: Hydrostatic -] Pneumatic F- Nominal Operating Pressure [ Other - Exempt E] Pressure 98 psig Test Temp. 50.7 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed 6 TECHHSPEC Date _ /, ,20 oo

-Ow ne or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period - .to 6 -2bO and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

• • % t .\ Commissions NC 978

Inspector's Signature

Date L-'b ,20_ CAD

Page 2 of 2 Revision 6

Section E Exibit A

Page 4: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (,

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/29/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 0 1 L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 970. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEExpiration Date N/A

4 Identification of System KC COMPONENT COOLING SYSTEM Class A 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com onents RetDaired or Reolacement Comnonents

Section E Exhibit A

Sheet 1 of 1

"12 [] 3 [] Shared (specify Units] )

)3102-09

9154

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number(yes or no)

A Valve Walworth D63588 964 For valve tag 1KC463 1976 REPLACED

B Valve Fisher 4153B-01A 368 For valve tag 1KC463 1998 REPLACEM.

C Pipe Duke Power C-1KC 129 4" Pipe-SA106 Pipe welds-1KC12- REPLACEM' Co. 7,6,12,8

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 5: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Valve 1 KC463_

8. Test Conducted: Hydrostatic [D Pneumatic [- Nominal Operating Pressure Other -- Exempt FI

Pressure 95 psig Test Temp. 67.2 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate ofuthorization No. N/A

Signed 7,e2l le.--.•.

/ Owner or Owner's Designee, Title

Expiration Date N/A

Date /Z !, ,19_

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period J-1Z93. to S-A-_ and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

NC 978

Inspe -. tor__ Signature

Date ~- 1~ _

C"nmmnczinn-

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 6: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/28/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 0 1 E: Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 980(

Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A

Expiration Date N/A 4 Identification of System Class B

NV CNEMICAL VOLUME CONTROL SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Identification of Comnonents Renaired or Renlacement Comnonents

( Section E Exhibit A

Sheet 1 of 1

]2 n 3 [ Shared (specify Units- )

)1747-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

Number ((yes or no)

A Disc Kerotest For valve tag 1NV186A REPLACED

B Disc Kerotest For valve tag 1NV186A REPLACEMI

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 7: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Disc for valve 1NV186A_

8. Test Conducted: Hydrostatic 0-'i Pneumatic F-- Nominal Operating Pressure ED Pressure psig Test Temp. deg.F.

Other - Exempt ED

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp NIA

Certificate uthorization No. N/A

Signed 7ýa -~ S.,ec/ Owner or Owner's Desi nee, Title

Expiration Date N/A

Date'

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period Q-Lo'L to -'A"Y1; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectl 2 $

i )s,__ _ _ _ _ _ _ _ _ Commissions NC 978

Insp tor' s Signature

Date _-A -,19_0

Page 2 of 2 Revision 6

I

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 8: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/28/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Zi E" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 980 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEExpiration Date N/A

4 Identification of System Class C KD DIESEL GENERATOR COOLING WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 ] 3 ['- Shared (specify Units[ )

02969-01,07,04

-10754

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped _ Number (yes or no)

A Valve BIF N59034-6 288 For valve tag 1KDO10 1979 REPLACED

B Valve Fisher 1136D-010A 385 For valve tag 1KDO10 2000 REPLACEM]

C Pipe Duke Power C-1KD 99 8" Pipe-SA106, Flange-SA105 REPLACEM. Co.

D Pipe Welds Duke Power C-1KD 99 1KD12-43,5 REPLACEM] Co.

E REPAIRED

F REPAIRED

Page 1 of2 Revision 6

Page 9: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve 1KD010_

8. Test Conducted: Hydrostatics- Pneumatic [ Nominal Operating Pressure Pressure psig Test Temp. deg.F.

Other [ Exempt El

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Expiration Date N/AType Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

/ Ow~ner or Owner's Designee, TitleTECH SPEC Date II/,- 20 Oc)

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period lb- 2 6 -0 & to / - 4-4 - and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ _C Commissions NC 978

Inspector's Signature

Date _ 1-1 1,20_ 1 _

Form NIS-2 (Back) Section E Exibit A

Page 10: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/25/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 0 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 980. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Tdantificntion of Comnonents Ren~aired or Renlacement Comnonents

1.

Section E Exhibit A

Sheet 1 of 1

-2 F- 3 F-- Shared (specify Units-] )

55707-01

L

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Pipe Duke Power C-1RN 117 Pipe-SA106, Elbow, Coupling-SA106 REPLACEM] Co.

B Pipe Duke Power C-1RN 117 Pipe welds-lRN317-1,8,7,6,3,2 REPLACEM Co.

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 11: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace RN piping-

8. Test Conducted: Hydrostatic 0Z Pneumatic D Nominal Operating Pressure Pressure 76 psig Test Temp. 60 deg.F.

Other EI] Exempt [-

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Si tid /,,, "Owner or Owner's Designee, Title

Date •SI• 19.50...

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period J -1V6k to Bl-Di9; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

_ _ _ _ ,,t_._ _ Commissions NC 978

Inspector's Signature

Date_-b- __,19-"N' _ -

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 12: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/29/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit N 1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 980! Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class C NW CONTAINMENT PENETRATION VALVE INJECTION WATER 5. (a) Applicable Construction Code 1II 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Ide~ntificaition of Comnonent.• Renaired or Renlacement Comrnonents

Section E Exhibit A

Sheet 1 of 1

]2 [-3

55708-10

E] Shared (specify Units[-] )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Pipe Duke Power C-1RN 117 2" Pipe-SA376 & SA106, Ellbow- REPLACEM Co. S A105, Cap-S A 1 O5/,AD/ 11C,,a /?. :S41,0 e,

B Pipe welds Duke Power C-1RN 117 1RN318-1,2,3,6,7,8 REPLACEM Co.

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

/' l

Page 13: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace pipe and clean valve_

8. Test Conducted: Hydrostatic [- Pneumatic L] Nominal Operating Pressure

Pressure 76 psig Test Temp. 60 deg.F.

Other Ij Exempt El

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed , 7" / • e e-

/ Owner or owners ueslgnee, IlWe

Expiration Date N/A

Date 7 ,/9Z_19

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 1-Z,'J -11 to 8 -Q4,A. and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

in A Commissions NC 978

Inpector's Signature

Date _% -2-A__ ,19_ Y\ __

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit A

Page 14: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/15/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit ] 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 980( Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE ,6., Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

"2 -3 [-- Shared (specify UnitsD[

54422-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

_ _ _4 _ 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Bolting Rod- SA564, Hex Nut-SA564 for RHR REPLACEMI Pump 1B Inlet/Outlet Flanges

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 15: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R Corroded Studs for RHR Pump lB_

8. Test Conducted: Hydrostatic D Pneumatic [ Nominal Operating Pressure D Pressure psig Test Temp. deg.F.

Other [] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed "

/

Expiration Date N/A

TECH SPEC Date 4 •, ,20 06Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period O?.-&-w to 0 h /S-6O and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property tdamage or a loss of any kind arising from or connected with this inspection.

_______________Commissions NC 978

"Yuspector's Signature

Date - 5_,20 C __ ,

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 16: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/15/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 [ Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 980 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 -] 3 [-] Shared (specify Units' )

78647-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Bolting Rod- SA564, Hex Nut-SA564 for RHR REPLACEM Pump 1A Inlet/Outlet Flanges

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 17: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work R/R Corroded Studs on RHR Pump I A_

8. Test Conducted: Hydrostatic -1 Pneumatic [1 Nominal Operating Pressure [ Pressure psig Test Temp. deg.F.

Other [' Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed oTm TECH SPEC O&0ner or-Owner's Designee, Title

Expiration Date N/A

Date Vzffi ,20 00

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period L6,0-0o to I (- /S 60 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

__ .,a Commissions NC 978

Inspector's Signature

Date 20_(U3

Page 2 of 2 Revision 6

Form NIS-2 ( Back)ASME Section XI Manual Section E Exibit A

Page 18: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

/ ( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/06/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Z 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 980f Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM 5. (a) Applicable Construction Code 1II 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Tde~ntificnition of Co2mnonnent• Re~n~ire~d or Renliccment Ccomnonent.•

Section E Exhibit A

Sheet 1 of 1

]2 VR 3 E] Shared (specify Units- )

35966-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Bolt Rod- SA193, Nut-SA194 for valve REPLACEM 1ND26

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 19: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work I/R Valve 1ND26_

8. Test Conducted: Hydrostatic ] Pneumatic [] Nominal Operating Pressure I-I Pressure psig Test Temp. deg.F.

Other [] Exempt E

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Siorned /Z 6s& ( -

/

Expiration Date N/A

Date -19 3LOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I ComDany of Hartford Connecticut have

inspected the components described in this Owners Report during the period _-•-•_ to e5-Io-2_; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

_Commissions NC 978

Inspector's Signature

Date _E5- __ ,19_-q ' _-

Page 2 of 2 Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

Page 20: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

,, (

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/06/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 980c Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEExpiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code II1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

-2 E- 3 r-1 Shared (specify UnitsD-] )

)9678-11

9751

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Valve BIF N44472-12 73 Valve tag 1RN051A 1976 REPLACED

B Valve Fisher 95848-030A 376 Valve tag 1RN051A 1999 REPLACEM]

C Bolts Studs/nuts for valve IRN051A REPLACEM]

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2

Revision 6

Page 21: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Valve 1RN051A_

8. Test Conducted: Hydrostatic ["- Pneumatic F- Nominal Operating Pressure Pressure 78 psig Test Temp. 60 deg.F.

Other -l Exempt El

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed A &SZ ý,2e-, .Iee-

/

Expiration Date N/A

Date 7/5- 19F .. _ /19Owner or Owner's Eiesignee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _ -.) J - to •&3Z1-_; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

&A•_,'_ Commissions NC 978 Inspector's Signature

Date_8-- _ ,19_ 9qG

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 22: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/06/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 " Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 980. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEExpiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

]2 [ 3 [ Shared (specify UnitsL-] )

)9680-10

9751

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Valve BIF 40846-3E 187 Valve tag 1RN050B 1987 REPLACED

B Valve Fisher 3345B-02B 366 Valve tag 1RN050B 1998 REPLACEM]

C Bolt Studs/Nuts for valve 1RN058 REPLACEM]

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 23: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Valve IRN0050B_

8. Test Conducted: Hydrostatic El Pneumatic - Nominal Operating Pressure Other L-" Exempt [E Pressure 78 psig Test Temp. 60 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

/

Expiration Date N/A

Date ,/S" 19_

Owner or Owner's 'esignee, Title"

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period -5. .521_ - to e 21-9 9_; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

""A_ M__ 4 ) Commissions NC 978

Inspector's Signature

Dateb 2- ,19 9 -

Page 2 of 2 Revision 6

Section E Exibit AForm NIS-2 ( Back)ASME Section XI Manual

Sioned

Page 24: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/17/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Zl E1 Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981( Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System RF- Fire Protection System Class A 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Comtonents Retaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 L-- 3 [] Shared (specify Unitsl-] )

)7210-13

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number (yes or no)

A Rear Bracket Grinnell For Hanger 1-A-RF-3048 REPLACEM]

B 5/8" Heavy Hex For Hanger 1-A-RF-3048 REPLACEM' Nut

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

((

k

Page 25: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Restore Hanger 1-A-RF-3048_

8. Test Conducted: Hydrostatic El Pneumatic - Nominal Operating Pressure 'Pressure psig Test Temp. deg.F.

Other El- Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed A&"TECH SPEC

/ Owner or Owner's Designee, Title

Expiration Date N/A

Date 0,,1 Oo

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period S-2.-I-)! to I -1-0C°and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

2Aj ý (V M"1 Commissions NC 978

Inspe'tor's Signature

Date P ",ZV C

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 26: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(. CASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/02/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 E" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEExpiration Date N/A

4 Identification of System CA AUXILIARY FEEDWATER SYSTEM Class B 5. (a) Applicable Construction Code 1m1 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6q Idlentificaition of Comnonents• Renaired or Renlacement Comnonent,•

S Section E Exhibit A

Sheet 1 of 1

12 [-D 3 [-- Shared (specify UnitsD )

09436-01

-10021

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Ceeril Replacement Stamped Number _(yes or no)

A Pipe Duke Power C-1CA 121 2" Pipe-SA335 Gr. P11, 90 ell-SA182, REPLACEM] Co. Tee-SA182

B Pipe Welds Duke Power C-1CA 121 1CA109-33,79,62,80,59,60,61,58,37 REPLACEM] Co. ,38,42,43,39,40,44,45,46,4,5,6,

C 1CA109-1,32,63,41 REPLACEM

D Valve Kerotest TX5-13 13789 Valve tag 1CA189 1977 REPLACED

E Valve Kerotest DAN1-20 31247 Valve tag 1CA189 1980 REPLACEM]

IF REPAIRED

Page 1 of 2 Revision 6

Page 27: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace 2" CA Piping-

8. Test Conducted: Hydrostatic El Pneumatic - Nominal Operating Pressure [7 Pressure 1070 psig Test Temp. 358 deg.F.

Other [] Exempt []

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed A -7',-, rc. Owner or Owner's D~ignee. Title

Expiration Date N/A

Date ?Z Z- -19_...5_

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period A4S' 14_ to S -2S-53 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

"_ _ _ _ CCommissions NC 978

Inspector's Signature

Date _- .5 19_"O -

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit A

Page 28: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY 1 a Date 07/07/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981i Address 526 S. Church St. Charlotte, N.C. 28201-1006 9',*/ Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEExpiration Date N/A

4 Identification of System KC COMPONENT COOLING SYSTEM Class C 5. (a) Applicable Construction Code 1m1 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com onents Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

2 -3

24787-02 //S€v- Z-/

11389

D Shared (specify Units-] )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

ComonntReplacement Stamped Number _(yes or no)

A Valve BNL A981103-13- NA Valve tag 1KC-A53 1999

B Valve BNL A981103-13- NA Valve tag 1KC-A59 1999 *E-AfýD __ _ _ _ 1 ____ _-____ _,__ ____ ___

C Valve BNL A981103-14- NA Valve tag 1KC-E29 1999 REPaID 1 NA Valve tag_ 1C399_P_

D Valve BNL A981103-4-1 NA Valve tag 1KC-E33 1999 REPAED ""______ o

E Valve BNL A981103-4-3 NA Valve tag lKC-E30 1999 -RFA14 -.

F Valve BNL A981103-4-2 NA Valve tag 1KC-E32 1999 RRPAiREB

Page 1 of 2 Revision 6

Page 29: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

/ fi

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY 1 a Date 07/07/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 E" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEExpiration Date N/A

4 Identification of System KC COMPONENT COOLING SYSTEM Class C 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Reoaired or Replacement Com~onents

Section E Exhibit A

Sheet 1 of 1

"]2 [-] 3 [-] Shared (specify UnitsD )

224787-02

11389

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped (yes or no)

A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05

B Pipe welds Duke Power C-1KC 129 1492KC379-1 2 3 4, 1KC950-35 34 33 REPLACEM' Co. 32, 1492KC377-1 2 3 4 5 6 7 8

C 1KC977-19 20 13 12, 1492KC376-1 4 5 REPAIRED 6 7 8 1KC975-21 15 14 22

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 30: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Perform KC Tie-in-

8. Test Conducted: Hydrostatic E] Pneumatic [-] Nominal Operating Pressure Pressure 98 psig Test Temp. 92 deg.F.

Other - Exempt El

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section X1.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed _ ,, 7- •Z& , ,,e

/ Owner or Owner's Designee, Title

Expiration Date N/A

Date - ,19_._

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period S__-2,L-'•_ to )-2>-'_; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

& " w V1, 4 i- Commissions NC 978 Inspector's Signature

Date ') "2-),19_ 0Q\

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section X1 Manual

Page 31: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/03/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 E" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/.P Expiration Date N/A

4 Identification of System CA AUXILIARY FEEDWATER SYSTEM Class B 5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 F- 3 F-1 Shared (specify Units- )

13648-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Bolts Cap Screw-A574 for valve 1CA-163 REPLACEM]

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

\

Page 32: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) Sinformation in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work hR Valve 1CA163_

8. Test Conducted: Hydrostatic E- Pneumatic[- Nominal Operating Pressure Other 1111 Exempt Z Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of uthorization No. N/A

Signed // aL . 7eb,' ,pe-Owner or Owner's Des(gnee, Title f

Expiration Date N/A

Date ''/ ,'19__

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _S - -9a. to F3 and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

______ ,_- _____ Commissions NC 978

Inspector's Signature

Date _8-2 ,19_ -

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 33: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY 1 a Date 08/02/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Z 1 E" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System NI SAFETY INJECTION SYSTEM Class B 5. (a) Applicable Construction Code 1II 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Con onents Renaired or Renlacement Comoonents

Section E Exhibit A

Sheet 1 of 1

12 [-- 3 ] Shared (specify Units- )

15469-03

L

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Bolts ½2" Hex nuts-SA-194 for hanger 1-A-NI- REPLACEMI 4389

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page I of 2 Revision 6

/ (

Page 34: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) "- information ihi items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Restore Hanger 1-A-NI-4389_

8. Test Conducted: Hydrostatic 1-- Pneumatic [ Nominal Operating Pressure D Pressure psig Test Temp. deg.F.

Other 0 Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

Page 2 of 2 Revision 6

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of 2uthorization No. N/A.

Date .14-,1 59Owner- or (Nwner's Desgnee, Title f

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period .dL to8 i3"-1; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _•_ _ __m__ Commissions NC 978

Inspeclor's Signature

Date -&21 -,19-9)

-7, d, S a P t,S_

Form NIS-2 ( Back) Section E Exibit A

Si ned•

Page 35: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY l a Date 07/06/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 LAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System NI SAFETY INJECTION SYSTEM Class B 5. (a) Applicable Construction Code I11 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 -- 3 F-1 Shared (specify UnitsD-] )

18589-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped _ Number (yes or no)

A Bolt Threaded Rod/Nuts for valve 1NI- 119 REPLACEM]

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

k

Page 36: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work R/R Valve INI-119

8. Test Conducted: Hydrostatic [ Pneumatic F1 Nominal Operating Pressure-' Pressure psig Test Temp. deg.F.

Other[-Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

/

Expiration Date N/A

Date / ,19_•_

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 4.9,-. to ")..99; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

\Commissions NC 978

Inspector's Signature

Date _- -'2-- _19_ )

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 37: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/09/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 [Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System NI SAFETY INJECTION SYSTEM Class A 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 T1ontificnntion of Comnonents• Renairedi or Renlaeement Comnonents•

Section E Exhibit A

Sheet 1 of 1

12 [-] 3 D Shared (specify Units-] )

18590-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Disc Westinghous 6851 NA Valve tag #1NI-125 REPLACEMl e

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

k

Page 38: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work I/R Valve INI-125_

8. Test Conducted: Hydrostatic 1E] Pneumatic 1] Nominal Operating Pressure E"I Pressure psig Test Temp. deg.F.

Other [- Exempt F1

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed _/&e_ ZA•2- : ,/ Owner or Owner's Designee, Title

Expiration Date N/A

Date F19 ,19_22_.

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period _ _ to 8 -t1-0)J; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

P? ,." mqfV ) Commissions NC 978 Inspector's Signature

Date _• 10 _,19-4 )

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit A

01

Page 39: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/09/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 ' Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System NI SAFETY INJECTION SYSTEM Class A 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 TIdentification of Corn onent.• Renaired or Renlacement Comronents

Section E Exhibit A

Sheet 1 of 1

"12 -' 3 F-1 Shared (specify Units[] )

18653-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Ceeril Replacement Stamped

_ Number _ (yes or no)

A Disc Westinghous 1087-1 NA Valve tag #1NI-082 REPLACEM e

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

k

Page 40: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work hR Valve 1NI-082_

8. Test Conducted: Hydrostatic ] Pneumatic - Nominal Operating Pressure LPressure psig Test Temp. deg.F.

Other - Exempt Z

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed //CA /X -, C-

7-•_ Owner o;Owner'/Designee, Title f

Expiration Date N/A

Date ' 19

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _ -ý -9_ to 8-0-11; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

PL , r4W Commissions NC 978

Inspector's Signature

DateJ" IQ ,19 c" ___

Page 2 of 2 Revision 6

M

ASME Section XI Manual Form NIS-2 ( Back) Section E Exibit A

Page 41: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/06/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System CF MAIN FEEDWATER SYSTEM Class B 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19"89 Addenda NONE 6. Identification of ComDonents ReDaired or ReDlacement ComDonents

Section E Exhibit A

Sheet 1 of 1

"]2 '- 3 -- Shared (specify UnitsD )

19060-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number __ (yes or no)

A Cap Screw For valve 1CF-058 REPLACEMI

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

( I

Page 42: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work I/R Valve 1CF-058_

8. Test Conducted: Hydrostatic D] Pneumatic 0 Nominal Operating Pressure E] Pressure psig Test Temp. deg.F.

Other [] Exempt Z

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed AAý"-, S7Owner or Owner's Dfesignee, Title

Expiration Date N/A

Date 7 - ,19 9'-

CERTIFICATE OF INSERVICE INSPECTION

1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _,f2 _ -5)to6'2--9.; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

_ __ __ Commissions NC 978

Inspector's Signature

Date_-" 2-,19jc _)

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 43: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/06/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Hi E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System NI SAFETY INJECTION SYSTEM Class B 5. (a) Applicable Construction Code 11- 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com ponents Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

]2 [-- 3 [-] Shared (specify UnitsD )

19795-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number (yes or no)

A Bolt Threaded Rod/Nuts for valve INI-151 REPLACEM]

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

!

k

Page 44: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R Valve 1NI-151_

8. Test Conducted: Hydrostatic i- Pneumatic -- Nominal Operating Pressure L- Other - Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of thorization No. N/A

5Sicrned g ;e/ý S 'e e

Expiration Date N/A

Date •,ffi,1_

Owner or Owner's Ifesignee. Title

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _2'))-*$ to '" "29-); and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

___Commissions NC 978

Inspector's Signature

Date _ -" ,19_Q

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 45: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(

ASME Section XI Manual Section E Exhibit A

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY Address 526 S. CHURCH STREET. CHARLOTTE NC 28201-1006

2. Plant CATAWBA NUCLEAR STATION Address 4800 CONCORD RD. YORK, SC 29745

3. Work Performed By Duke Power Company Address 526 S. Church St. Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A

4 Identification of System NC REACTOR COOLANT SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 6. Identification of Components Repaired or Replacement Components

la Date 07/05/99

2a Unit H 1 []2 ['] 3 [-] Shared (specify Units

3a Work Order# 98120851-02

3b NSM or MN # N/A

Class A Code Cases 1989 Addenda NONE

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg. Mfg. Serial No. National Board Other Identification Year Repaired. ASME

No. (Size) Built Replaced. or Code Replacement Stamped

(yes or no)

A Safety Relief Valve Dresser BS-2865 N/A 1NC-001 1979 ** E NO I_ EIYES

B Safety Relief Valve Dresser BS-2866 N/A 1NC-002 1979 ** E] NO [:]YES

C Safety Relief Valve Dresser BS-2867 N/A 1NC-003 1979 ** E NO __YES

D Safety Relief Valve Dresser BS-2868 N/A SPARE 1979 ** E] NO I_ [:]YES

E Safety Relief Valve Dresser BS-2869 N/A 2NC-001 1980 ** E] NO _EYES

F Safety Relief Valve Dresser BS-2870 N/A 2-NC-002 1980 ** E] NO [-]YES

G Safety Relief Valve Dresser BS-2871 N/A 2-NC-003 1980 ** E] NO _EYES

H Safety Relief Valve Dresser BS-2872 N/A SPARE 1979 ** [] NO ["]YES

Page 1 of 2 Revision 6

Sheet of

)

Page 46: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work: Replace safety relief valve INC-001 with existing spare.

8. Test Conducted: Hydrostatic s Pneumatic -- Nominal Operating Pressures Other - Exempt L] Pressure 2235 psig Test Temp. 557 deg.F.

9. Remarks ** These valves are interchangeable and can be used in any of the valve applications / locations listed.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed, , , Date -19-Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Providence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 4--2f - 9 9 to 8-3 -9 9 ; and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

i Commissions NC 978

Inspector's Signature

Date _ -_

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 47: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual Section E Exhibit A

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMIENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la D Address 526 S. CHURCH STREET. CHARLOTTE NC 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a U Address 4800 CONCORD RD. YORK, SC 29745

3. Work Performed By Duke Power Company 3a VW Address 526 S. Church St. Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b N Expiration Date N/A

4 Identification of System NC REACTOR COOLANT SYSTEM Class 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Retaired or Renlacement Comtonents

ate 07-05-99 Sheet of

nit Z 1 02 R 3 [- Shared (specify Units

rork Order # 98120852-05

SM or MN # N/A

A

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8

Name of Component Name of Mfg. Mfg. Serial No. National Board Other Identification Year Repaired. ASME No. (Size) Built Replaced. or Code

Replacement Stamped (yes or no)

A Safety Relief Valve Dresser BS-2865 N/A INC-001 1979 ** Rl NO I [-]_YES

B Safety Relief Valve Dresser BS-2866 N/A 1NC-002 1979 ** LI NO [-]YES

C Safety Relief Valve Dresser BS-2867 N/A 1NC-003 1979 ** E] NO _]YES

D Safety Relief Valve Dresser BS-2868 N/A SPARE 1979 ** E] NO I" _]YES

E Safety Relief Valve Dresser BS-2869 N/A 2NC-001 1980 ** E] NO _-]YES

F Safety Relief Valve Dresser BS-2870 N/A 2-NC-002 1980 ** El NO _]YES

G Safety Relief Valve Dresser BS-2871 N/A 2-NC-003 1980 ** El NO I I_ I D-YES

H Safety Relief Valve Dresser BS-2872 N/A SPARE 1979 ** El No ["]YES

Page 1 of 2 Revision 6

Page 48: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work : Replace safety relief valve INC-002 with existing spare.

8. Test Conducted: Hydrostatic E-" Pneumatic LI] Nominal Operating Pressure 1n Other El Exempt Ii

Pressure 2235 psig Test Temp. 557 deg.F.

9. Remarks ** These valves are interchangeable and can be used in any of the valve applications / locations listed.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of uthorization No. N/A

Signed 4ýZA 25>:6e - Date _ ", 5 19- _L /Owner or Owner's EDesi gnee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Providence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period + 2-)'9 ] to -2- ; and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

atrYid / Commissions NC 978 Inspector'Is §ignature

Date -. _

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section X1 Manual

Page 49: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual Section E Exhibit A

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la D; Address 526 S. CHURCH STREET. CHARLOTTE NC 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a U Address 4800 CONCORD RD. YORK, SC 29745

3. Work Performed By Duke Power Company 3a W Address 526 S. Church St. Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b N Expiration Date N/A

4 Identification of System NC REACTOR COOLANT SYSTEM Class 5. (a) Applicable Construction Code m11 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Comronents Renaired or Re nlacement Comnonents

ate 07-05-99 Sheet of

nit E 1 "2 - 3 7 Shared (specify Units

'ork Order # 98120853-05

SM or MN # N/A

A

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg. Mfg. Serial No. National Board Other Identification Year Repaired. ASME

No. (Size) Built Replaced. or Code Replacement Stamped

(yes or no)

A Safety Relief Valve Dresser BS-2865 N/A 1NC-001 1979 ** [] NO ['-]YES

B Safety Relief Valve Dresser BS-2866 N/A 1NC-002 1979 ** El NO _E"YES

C Safety Relief Valve Dresser BS-2867 N/A 1NC-003 1979 ** [j NO I_ E]YES

D Safety Relief Valve Dresser BS-2868 N/A SPARE 1979 ** LI NO [-]YES

E Safety Relief Valve Dresser BS-2869 N/A 2NC-001 1980 ** FI NO _]YES

F Safety Relief Valve Dresser BS-2870 N/A 2-NC-002 1980 ** E] NO ,- E]YES

G Safety Relief Valve Dresser BS-2871 N/A 2-NC-003 1980 ** E] NO I I EDYES

H Safety Relief Valve Dresser BS-2872 N/A SPARE 1979 ** E[ NO I I []7YES

Page 1 of 2 Revision 6

/

Page 50: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 l/2in. x 11 in. (2) "information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work: Replace safety relief valve 1NC-003 with existing spare.

8. Test Conducted: Hydrostatic FL Pneumatic -- Nominal Operating Pressure "7 Other FL Exempt [] Pressure 2235 psig Test Temp. 557 deg.F.

9. Remarks ** These valves are interchangeable and can be used in any of the valve applications / locations listed.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Aythorization No. N/A

Signed /5 - , Date _. ;40 wner or Owner'f Designee, Ti-te

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Providence of NORTH CAROLINA and employed by HSB I AND I Companv of Hartford Connecticut have

inspected the components described in this Owners Report during the period 4-2-) -'C) to ")- 2-9 -) ; and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ __ _ _ Commissions NC 978

Inspector's Signature

Date _) -7 .__

Form NIS-2 (Back) Section E Exibit A

Page 51: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

I,

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/02/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 0 1 El Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 9812 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A e=•'-/7/f

4 Identification of System KC COMPONENT COOLING SYSTEM Class A5. (a) Applicable Construction Code 1II 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Comrnonents Rernaired or Replacement Comnonents

( Section E Exhibit A

Sheet 1 of 1

2 E] 3 E] Shared (specify Units[- )

0862-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Snubber PSA 4230 1-R-KC-0038 1978 REPLACED

B Snubber PSA 8973 1-R-KC-0038 1979 REPLACEM]

REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

(

Page 52: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/02/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Z 1 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A Cj; f/

4 Identification of System Class -C'9 NV CNEMICAL VOLUME CONTROL SYSTEM 5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

"2 E-] 3 F-1 Shared (specify Units' )

20862-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped

(yes or no)

A Snubber PSA 9051 1-R-NV-004 REPLACED

B Snubber PSA 26143 1-R-NV-004 REPLACEMl

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 53: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) "* information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work RIR Snubbers_

8. Test Conducted: Hydrostatic '-" Pneumatic E] Nominal Operating PressureE[ Other ] Exempt Z Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed -14*&ZEA

/ Owner or Owner's Designee, Title

Expiration Date N/A

7~~-A rcl Date / ,199 >'

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period +2Z -4tj to ,2-i; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

_Commissions NC 978

Inspec or's Signature

Date , ,1 9_.•

Page 2 of 2 Revision 6

BI • v ;F

Form NIS-2 (Back) Section E Exibit A

Page 54: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

K'

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/06/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 Ei Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System SA MAIN STEAM SUPPLY TO AUX EQUP Class C 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Reoaired or Reolacement Comoonents

/S

Section E Exhibit A

Sheet 1 of 1

12 F-"- 3 [-- Shared (specify Units- )

25137-03

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped _ (yes or no)

A Disc Borg Warner SN33 For valve 1SA007 REPLACED

B Disc Borg Warner SN37 For valve 1 SA007 REPLACEM]

C Bonnet Borg Warner SN45 For valve 1SA007 REPLACED

D Bonnet Borg Warner SN94 For valve 1SA007 REPLACEM]

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 55: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Inspect/Recondition Valve ISA007_

8. Test Conducted: Hydrostatic [-I Pneumatic -- Nominal Operating Pressure 1--"] Pressure 150 psig Test Temp. 365 deg.F.

Other E- Exempt [

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed a/•* i-j€-ý -o"• • c- Date ' 19..2._ /1&Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _-18-9TL to - and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

QLA "V J9, Commissions NC 978 Inspector's Signature

Datee-S ,19_--)

Page 2 of 2 Revision 6

Section E Exibit AForm NIS-2 (Back)ASME Section XI Manual

Page 56: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/26/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 01 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/IA Expiration Date N/A

4 Identification of System Class B

SV MAIN STEAM VENT TO ATMOSPHERE 5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Identification of Comnonents Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

"12 L-] 3 -- Shared (specify UnitsD )

27437-01

L

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Plug CCI S/N-1 N/A For relief valve 1 SV-007 REPLACEM.

B Bolt Rod-SA193, Nuts-SA194 for valve ISV- REPLACEM' 007

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

! /

Page 57: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work IiR Seat Leak_

8. Test Conducted: Hydrostatic nI Pneumatic -' Nominal Operating Pressure El Pressure psig Test Temp. deg.F.

Other E] Exempt E

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed A&*ý -• 7•-

/ Owner or Owner's Dd'signee, Title

Date 7?/24 ,J9iZ?

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period'S- 12.."a toi -1 -9 9_; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

NC 978Commissions

Da'ector's Signature

Date 5-~ i ,-9:ý%

Page 2 of 2 Revision 6

... r - --

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 58: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/26/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit El E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 9811 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEExpiration Date N/A

4 Identification of System CA AUXILIARY FEEDWATER SYSTEM Class B 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

]2 n 3 n-- Shared (specify UnitsE] )

27818-08

10021

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Ceeril Replacement Stamped

Number _(yes or no)

A Hanger Weld- 1-R-CA-1692-3 for hanger 1-R- REPLACEM] CA-1692

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 59: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

Section E Exibit AASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work R/R Hanger I -R-CA- 1692_

8. Test Conducted: Hydrostatic [] Pneumatic [ Nominal Operating Pressure L-Pressure psig Test Temp. deg.F.

Other [] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed 4' f , iec / - - Owner or Owner's Designee, Title

Expiration Date N/A

Date 24, ,19_ __

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period I .U A i to .1 .9¢•; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

L6,• W.-•.) Commissions NC 978

Inspector's Signature

Date_ . ( -,l9 ___

Page 2 of 2 Revision 6

Form NIS-2 (Back)

Page 60: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/26/99

Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 2 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981:

Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE]

Expiration Date N/A 4 Identification of System CA AUXILIARY FEEDWATER SYSTEM Class B

5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Com onents Repaired or Renlacement Components

Section E Exhibit A

Sheet 1 of 1

"]2 3 D Shared (specify UnitsD )

27824-01

.0021

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stamped

Number_ (yes or no)

A Pipe Duke Power C-1CA 121 Pipe-SA-335, Ell-SA-182, 4x2 Red- REPLACEM.

Co. SA234, Tee-SA-182

B Pipe welds Duke Power C-iCA 121 1 CAI 05-52,51,50,49,48,47,46,45,44,43, REPLACEM]

Co. 42,41,40,39,38,35,33,32,31,30,29,28,27

C 1CA105-,25,24,23,22,21,20,18,17,16,19, REPLACEM] 26,15,13,12,11,10,9,8,3,2,1,

D ?//,e.'- .ue/ A6 - /-R-c,9 -/4q-,J REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

(

Page 61: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace 2" Tempering Flow Pipe_

8. Test Conducted: Hydrostatic [] Pneumatic - Nominal Operating Pressure [ Pressure 1070 psig Test Temp. 362 deg.F.

Other E]- Exempt El

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed ., 7P$'c

/ Owner or Owner's Designe6, Title

Expiration Date N/A

Date •r ,19 2

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 3.31 Fj, to 8 3U1?.tb; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

NC 978Commissionsector's Signature

Date_ 8' __,19_9 _

Page 2 of 2 Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

Page 62: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY I a Date 09/07/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Zi EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEExpiration Date N/A

4 Identification of System CA AUXILIARY FEEDWATER SYSTEM Class B 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Icdntificeition of Cmnmonent.• Renaired or Renlacement Components

, Section E Exhibit A

Sheet 1 of 1

]2 E] 3 F-- Shared (specify Units-- )

27824-07

10021

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped _ Number (yes or no)

A Weld Duke Power C-1CA 121 Weld 1-R-CA-1647-3 for hanger 1-R- REPLACEM] Co. CA-1647

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 63: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Restore Hanger 1 -R-CA- 1647_

8. Test Conducted: Hydrostatic [I Pneumatic '- Nominal Operating Pressure[] Other D1 Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed O r s D

7SA Owner or Owner's Designee, Title

Expiration Date N/A

TECH SPEC Date I j9j,19

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period J-Za-91 to ý.'. and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

S4)( k4k) Commissions NC 978

Inspector's Signature

Date _4-.l __,191 _

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 64: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/02/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 0 1 E" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A

Expiration Date N/A 4 Identification of System NS CONTAINMENT SPRAY SYSTEM Class B 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of I

"12 [] 3 F-ý Shared (specify UnitsD-- )

28616-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped

_ (yes or no)

A Bolts Studs-SA193, Nuts-SA194 For REPLACEM] Containment Spray Pump"1A"

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

I

Page 65: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Suction Bolts on Suction Flange_

8. Test Conducted: Hydrostatic -1 Pneumatic -Nominal Operating Pressure [ Other F[ Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed A•ff JL-t~'. •A,,c. Owner or-Owner's Designee, Title

Expiration Date N/A

Date ,19!7

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _S-S-•0 t -235f; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

i t )o s Sn!,-, r Commissions NC 978

InDpeZor's Signature

SDate -b °U- , 19_9'

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 66: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( ( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/06/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981i Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System NI SAFETY INJECTION SYSTEM Class A 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com Donents Ret)aired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

]2 E] 3 - Shared (specify Units'] )

34460-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code NumerReplacement Stamped

Number (yes or no)

A Bolt Nut-SA453 for valve 1NI180 REPLACEM]

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

k

Page 67: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 l/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work I/R Valve 1NI-180_

8. Test Conducted: Hydrostatic ] Pneumatic - Nominal Operating Pressure D Pressure psig Test Temp. deg.F.

Other [] Exempt E

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of &uthorization No. N/A

Signed .a l-S-A

/

Expiration Date N/A

T-ec-l1-, Sf r C . Date /i ,191Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period -" -?- -)ý to e-Z-5a; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

SCommissions NC 978

Inspector's Signature

Date _5"-•Z,19_'jc __

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 ( Back)

Page 68: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 09/14/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit M 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System RN Nuclear Service Wtr. Sys. Class C 5. (a) Applicable Construction Code I11 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Con onents Renaired or Replacement Comnonents

Section E Exhibit A

Sheet 1 of 1

12 L-1 3 D Shared (specify Units[:] )

37352

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped ,Number (yes or no)

A Pipe Duke Power C-lRN 117 Pipe-SA106,Reducer SA403, Tee REPLACEM' Co. SA234, Elbow SA234

B Pipe Welds Duke Power C-1RN 117 0RN128-5, 0RN127-5,6,7,8,9,10 REPLACEM Co. 0RN128-1,2,3,4 0RN137-40,41,42

C Valve Pacific 419-6 133 Valve tag #1RN46 REPLACED

D Valve Pacific 0017-9 23 Valve Tag #1RN46 1979 REPLACEM]

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 69: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) "information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace RN Piping_

8. Test Conducted: Hydrostatic LII Pneumatic Nominal Operating Pressure Pressure 80 psig Test Temp. 60 deg.F.

Other 0 Exempt El

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Expiration Date N/AType Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed A_,•

/ Owner-r Owner's Designee, Title

TECH SPEC Date 18 ,19 9?,F

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 8 -29 to 3 /_-• _ and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

•Le 4 & M¢ Commissions NC 978 Inspector's Signature

Date 94 A -, ,19_ Ot %

Form NIS-2 (Back) Section E Exibit A

Page 70: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/09/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981, Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE f Tde'ntific~tinn nf Ccmn onent• Rennired or Renlacement Comnonents

(

Section E Exhibit A

Sheet 1 of 1

]2 [13 ED] Shared (specify Units[:] )

46594-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Boltsr _(yes or no)

A Bolts Cap Screw-SA193, Nut-SA194 for REPLACEM] Nuclear Service Wtr Pump "IB"

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 71: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work I/R RN Pump-

8. Test Conducted: Hydrostatic 0-- Pneumatic ] Nominal Operating Pressure D Pressure psig Test Temp. deg.F.

Other F] Exempt E

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Sihned ,, -7,',.,/

Expiration Date N/A

Date V9 '19S2Owner 6r Owner's Des(gnee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period .> 2.P--')3 to 8 410-95; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ __,__A_ Commissions NC 978 Inspector's Signature

Date _6-e13 __,19_

Page 2 of 2 Revision 6

0ý7

Form NIS-2 ( Back) Section E Exibit A

Page 72: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/28/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 I-Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981, Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class B BB STEAM GERATOR BLOWDOWN SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

]2 E] 3 -D Shared (specify Units[:] )

46814-03

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stamped Number_ (yes or no)

A Rear Bracket Grinnell For Hanger 1-R-BB-1766 REPLACEMI Corp.

B Welds Duke Power 1-R-BB-1766-6,5 REPLACEMI Co.

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 73: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Modify support 1-R-BB-1766_

8. Test Conducted: Hydrostatic El Pneumatic -- Nominal Operating Pressure E] Pressure psig Test Temp. deg.F.

Other E] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

/

Expiration Date N/A

Date 7 ,9Owner or Owner's D~signee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period -4-)-9 9- to 8 -119_; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

____ ____ ___ Commissions NC 978

Inspector's Signature

DateF :a"-,19-q) -

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Sioned

Page 74: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( CASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/25/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [1 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981L Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Identifieation of Comnonents Renaired or Retnlacement Comnonents

( Section E Exhibit A

Sheet 1 of 1

12 E] 3 F-- Shared (specify Units-] )

5395524

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Pipe Duke Power C-1RN 117 Pipe welds- 1RN49-22,10 1RN111-9,15 REPLACEM] Co.

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 75: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work R/R RN Piping_

8. Test Conducted: Hydrostatic El Pneumatic ]Nominal Operating Pressure H Other [l Exempt [E Pressure 75 psig Test Temp. 62 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed A•e5;,. '< 7•,4 S'e,

/ Owner or Owner's Designee, Title

Expiration Date N/A

Date •..f, 19?9_

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period S_- ?-) to 9]A -. _U and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

U 4 Commissions NC 978 Inspector's Signature

Date q . I -,19_qý )

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit A

Page 76: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( ( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 10/07/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 F" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEExpiration Date N/A

4 Identification of System Class C

RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 1II 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identific~tion of Cmnm nents Retnaired or Renlacement Comnonents

Section E Exhibit A

Sheet & of .- Z.

"12 Dý 3 [-] Shared (specify Units[] )

55700-11

61478

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Pipe Welds Duke Power C-1RN 117 1RN125-26,27,28,29,40,41,16,17,18, 19, REPLACEM]

Co. 20,21, 22,23,24,25,

B 1RN 181- REPLACEM' 39,38,BMR1,BMR2,BMR3,BMR4 __________--_

C Pipe Clamps Grinnell For Hanger 1-R-RN-231 REPLACEM]

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 77: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

K ( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 10/07/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 I-Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981. Address 526 S, Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEExpiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of,-?".?

-]2 E"13 F-] Shared (specify UnitsD-] )

55700-11

61478

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A 10" 8" & 6" Pipe Duke Power C-1RN 117 Pipe-SA106, 90 Elbows-SA234, 8x6 REPLACEM Materials Co. Reducers-SA234, Flanges-SA105

B 10x8 Reducers-SA234, 45 Elbow- REPLACEM. SA234

C Sway Strut ITT Grinnell 1993-167 For hanger 1-R-RN-0231 REPLACEM]

D Sway Strut ITT Grinnell 8983 For hanger 1-R-RN-0231 REPLACED

E Valve Limitorque 94562-01A 339 Valve tag 1RNE-95 1997 Riftft~m

F Bolting Duke Power C-1RN 117 Rod-SA193, Nuts-SA194 REPLACEM Co. I

Page 1 of 2 Revision 6

Page 78: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

S4NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Add Flow Instrument on RN Piping_

8. Test Conducted: Hydrostatic -- Pneumatic [X Nominal Operating Pressure L-I Pressure 75 psig Test Temp. 65 deg.F.

Other E-] Exempt E]

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

Expiration Date N/A

TECH SPEC Date 4011 ,_19

/" Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 5- I -`%. to 1 0- II 11 and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

•4'J• }_ L4),J••- Commissions NC 978

Inspector's SignatuC

s

DateJ0 -fl _ 19_ _)

Page 2 of 2 Revision 6

TECH SPEC

Section E Exibit AForm NIS-2 (Back)ASME Section XI Manual

Page 79: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

/ ( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY l a Date 08/02/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981l Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

( Section E Exhibit A

Sheet 1 of 1

2 [-- 3 F-- Shared (specify Units- )

56835-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Disc Kerotest SN 8 For valve lNV-874 REPLACEM]

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 80: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) "information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Repair valve 1NV874_

8. Test Conducted: Hydrostatic l Pneumatic ' Nominal Operating PressurePressure psig Test Temp. deg.F.

Other - Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed _2*/

/

Expiration Date N/A

Date Z? ,-19 _ If

Owner or Owner's l-esignee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _.-,$-l.. to 8 "2•-•; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

_ _ _ _ _ _ Commissions NC 978 Inspector's Signature

Date ._Q"•k,19_•ý -

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 81: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( KASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/29/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit i 1 I Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981V Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System NC REACTOR COOLANT SYSTEM Class A 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE i• Trl~thlcentlnn Afe tCmnnne.nt• P•.nniredl nr lRenlacemrent Comnonents

Section E Exhibit A

Sheet 1 of 1

12 R 3 - Shared (specify Units- )

57265-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Base Metal Westinghous N/A Reactor Vessel Head REPAIRED Repair e

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 82: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Repair Reactor Head

8. Test Conducted: Hydrostatic "l] Pneumatic [ Nominal Operating Pressure 1- Other L- Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of uthorization No. N/A

Signed M z-zw - ý;ý , 7"i e-.

/

Expiration Date N/A

Date -7/Z" ,19 ._Owner or-Owner's besignee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period G'S •-9to l-Zi_ and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

& ", X Vv•Y'4.A Commissions NC 978

Inspector's Signature

Date _-2A_ 19 __

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 ( Back)

Page 83: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

I, (

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/03/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A C1p/,/

4 Identification of SystemYC- Control Room Area Chiller Sys. Class A-. 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Comtonents Renaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

]2 1-3

57345-01

--1 Shared (specify Units-- )

L

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Boltsr (yes or no)

A Bolts Cap Screw-SA489 for Control Room REPLACEM] Area Chiller (1CRA-C-1)

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 84: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Clean/Inspect Chiller_

8. Test Conducted: Hydrostatic [-" Pneumatic F-' Nominal Operating Pressure [] Pressure psig Test Temp. deg.F.

OtherE [Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed 2-e &/ Owner or Owner's Designee, Title

Expiration Date N/A

Date -%19?

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _°'_ to ,A. t and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Inspc g VX."-•,) Commissions NC 978

Inspector' s"Signature

Date .. ,19_ -

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 85: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/06/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Piant CATAWBA NUCLEAR STATION 2a Unit [ 1 IE Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEExpiration Date N/A

4 Identification of System Class B BB STEAM GERATOR BLOWDOWN SYSTEM 5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

"12 - 3 - Shared (specify UnitsD-] )

58559-07

9509

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped

(yes or no)

A Bolting /2" Nut-SA307, Bolt-A563 for hanger 1- REPLACEM] R-BB-1846

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 86: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Restore Hanger 1-R-BB- 1846_

8. Test Conducted: Hydrostatic LI Pneumatic [] Nominal Operating Pressure -li Pressure psig Test Temp. deg.F.

Other L- Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of/uthorization No. N/A

Signedre ;A Owner or bKner' s Designee, Title

ct- SPfccc

Expiration Date N/A

Date 7/,.5- 19__

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _ g _ to & -+), and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

___Commissions NC 978

Inspector's Signature

Date -a "s,-- ,191_ _

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 87: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/02/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 I-Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 T4entific.~tion of Conon•nent• Renaired or Renlaeement Comnonents

Section E Exhibit A

Sheet 1 of 1

"12 D-' 3 [] Shared (specify Units[-- )

58661-07

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _ _(yes or no)

A Pipe Duke Power C-lRN 117 6" pipe-SA106 Gr. B REPLACEM] Co.

B Pipe Duke Power C-lRN 117 Pipe Welds-1RN125-42,6 1RN48-3,14 REPLACEM] Co.

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2

Revision 6

Page 88: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Clean RN Piping

8. Test Conducted: Hydrostatic [I] Pneumatic [ Nominal Operating Pressure [, Other D Exempt []

Pressure 75 psig Test Temp. 65 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Ce of uthorization No. N/A

Signed

Expiration Date N/A

Date 7'/7 ,1919

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period -5-*) -5 to 8 -Z-A-•; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

2V" _y)•__• __ Commissions NC 978 Inspect&'s Signature

Date -a -A_,l919_ -

Page 2 of 2 Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

Page 89: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

/ (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/06/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System NI SAFETY INJECTION SYSTEM Class B 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Comrnonents Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

12 D 3 E" Shared (specify UnitsD-- )

59742-03

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

ComonntReplacement Stamped Number _(yes or no)

A Bolt Bolt/nuts for hanger 1-A-NI-4389 REPLACEM]

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 90: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Restore Support 1-A-NI-4389_

8. Test Conducted: Hydrostatic L- Pneumatic j"- Nominal Operating Pressure El Pressure psig Test Temp. deg.F.

Other 0 Exempt M

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate oAuthrization No. N/A

SignedOwner or< Owner's Designee, Title

Expiration Date N/A

Date F/K- ,19,79

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period &- 14_99 to &29'; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

YfA V ' ) Commissions NC 978 Inspector's Signature

Date -2. _,19_3 -

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 91: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( .ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY 1 a Date 07/06/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System NI SAFETY INJECTION SYSTEM Class B 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Identification of Comnonents Rernaired or Rernlacement Comronents

Section E Exhibit A

Sheet 1 of 1

12 -- 3 F-- Shared (specify UnitsD-' )

60660-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Disc Borg Warner For valve 1N1162A REPLACEM]

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2

Revision 6

Page 92: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) Sinformation in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Repair Valve 1NI162A_

8. Test Conducted: Hydrostatic [L Pneumatic 0-I Nominal Operating Pressure El Pressure psig Test Temp. deg.F.

Other ] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of A thorization No. N/A

/

Expiration Date N/A

Date ý/,5" -1992%

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period Sr I 1 -99 to 9--A.; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

VA,4k Commissions NC 978 Inspector's Signature

Date 8 -" _&,19,ý- _

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Sioned

Page 93: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/25/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Hi E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 9814 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM 5. (a) Applicable Construction Code m 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com ponents Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 E] 3 [: Shared (specify Units- )

64004-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped _ Number _ (yes or no)

A Base Metal Duke Power C-1NV 127 Base metal repair to the Seal Wtr REPAIRED Repair Co. Injection Filter 1A cover.

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 94: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Weld repair filter cover_

8. Test Conducted: Hydrostatic [- Pneumatic ] Nominal Operating Pressure El Pressure psig Test Temp. deg.F.

OtherE [Exempt ED

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed A& z/•,-, -

/

Expiration Date N/A

Date / ,19_ _

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _&S-) CL to 68 11 and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

____Commissions NC 978

Inspector's Signature

Date _ O" -,193s

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 95: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

I,(

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/06/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit N 1 E' Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/.A Expiration Date N/A

4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM 5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

( Section E Exhibit A

Sheet 1 of 1

12 E" 3 El Shared (specify Units[-] )

64004-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Ceeril Replacement Stamped

Number _(yes or no)

A Truinion Bolt For Seal Water Injection Filter 1A REPLACEMl

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 96: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 l/2in. x 11 in. (2) Sinformation in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Bolts on Seal Wtr. Injection Filter 1A-

8. Test Conducted: Hydrostatic [-I Pneumatic n--' Nominal Operating Pressure

Pressure psig Test Temp. deg.F.Other - Exempt M

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed &/-7

Expiration Date N/A

Date 7/3- 19_Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period &-)' -_ to S - and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

D.,- r 4" , Commissions NC 978

Inspector's Signature

Date _6- ,l __,_

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 97: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

. (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/28/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [: 1 [ Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

(Section E Exhibit A

Sheet 1 of 1

"]2 [] 3 - Shared (specify Units] )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Pipe Duke Power C-1RN 117 4" pipe- SA312 Tp304 Sch. 40 REPLACEM] Co.

B Pipe welds Duke Power C-1RN 117 1RN523-4,3, REPLACEM] Co.

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

67516-01/Py

Page 98: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) ' information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace RN Piping

8. Test Conducted: Hydrostatic 111 Pneumatic [i] Nominal Operating Pressure [\ Other ['] Exempt LI Pressure 76 psig Test Temp. 76 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed - 7&F '4,_ee Owner or Owner's Desigdee, Title

Expiration Date N/A

Date 7/Z S ,195'

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _-) 1i_ to B- 1-9 _; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

_ Commissions NC 978

Inspector's Signature

Date_ e-• -_ ,19_ \ _

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit A

Page 99: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

I, (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/10/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 FAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System NC REACTOR COOLANT SYSTEM Class B 5. (a) Applicable Construction Code TII 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

"]2 -] 3 F-1 Shared (specify UnitsD-- )

68357-03

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Bolting Bolt-SA307, Hex Nuts-SA194 for REPLACEM] hanger 1 -R-NC- 1871

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 100: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

"- information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Restore Support 1-R-NC-1871_

8. Test Conducted: Hydrostatic -- Pneumatic L- Nominal Operating Pressure 'Pressure psig Test Temp. deg.F.

Other E- Exempt M

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed L& L/

Expiration Date N/A

TECH SPEC Date /20Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period J1/ -5 -OD to / 10-l - and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

Inspector's Signature

Date _1- IV __,20-0 __

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 101: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(/,

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 09/14/99

Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006 2. Plant CATAWBA NUCLEAR STATION 2a Unit Zl E

Address 4800 CONCORD RD. YORK, S.C. 29745 3. Work Performed By Duke Power Company 3a Work Order # 981'

Address 526 S. Church St. Charlotte, N.C. 28201-1006 9al

Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of SystemYC Control Area Chilled Wtr. Sys. Class C 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Idelntification of Coomrnents Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

"2 [- 3 E Shared (specify Units- )

74424-01 qc•J3 7 - o/

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped _Number (yes or no)

A Base Metal 700425 141116 Perform base metal repair around bolt REPAIRED Repair holes for chiller 1-CRA-C-1

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

/

Page 102: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Weld repair bolt holes for Chiller 1 CRA-C- I_

8. Test Conducted: Hydrostatic [0 Pneumatic jFI Nominal Operating Pressure D Pressure psig Test Temp. deg.F.

Other [--] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

Page 2 of 2 Revision 6

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Expiration Date N/A

Date /t ,9'

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed /" TECH SPEC OwNner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 8-•do•9 to -A•_and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

NC 978Commissions

Inspeltor's Signature

Date _ - I "•X__ 19

Section E Exibit AForm NIS-2 ( Back)ASME Section XI Manual

Page 103: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

I, (

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/10/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [1 Li Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 D 3 D] Shared (specify Units[--] )

74815-01/04

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Bonnet Kerotest AGZ-2 36375 For Valve tag #1NV181A 1983 REPLACED

B Bonnet Kerotest FAL-5 35684 For Valve tag #lNV181A 1983 REPLACEM]

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 104: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) - information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Rebuild Valve INV 181 A_

8. Test Conducted: Hydrostatic [-1 Pneumatic -- Nominal Operating Pressure Pressure 125 psig Test Temp. 90 deg.F.

Other -- Exempt E]

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Expiration Date N/AType Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed _/ Aa •z ,...--

/ Owner or Owner's Designee, TitleTECH SPEC Date &6 ,20_0/

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period 10 -Z•-O6 to t -10 -0 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ __ _ Commissions NC 978

Inspctor's Signature

DateJ" t" - ,200o 1

Form NIS-2 ( Back) Section E Exibit A

Page 105: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( ( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 05/03/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit N 1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981) Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of SystemRF- Fire Protection Sys Class B 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

2 [-] 3 - Shared (specify UnitsL-- )

75079-14

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped

(yes or no)

A Rear Bracket Grinnell For hanger 1-A-RF-3062 REPLACEMI ~~ pi. . ¢ .. ,,.o

B Welds Duke Power C-1RF 110 Welds 1-A-RF-3062-ý, 6 for hanger 1- REPLACEM' Co. A-RF-3062

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

l/

k

Page 106: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I 1 in. (2) "information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Remove 1-A-RF-3062_

8. Test Conducted: Hydrostatic Ej Pneumatic [- Nominal Operating Pressure Other -- Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed Aiý ý Ower r Owner's Designee, Title

Expiration Date N/A

TECH SPEC Date _,20-00

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 2.-Z3 ' to S-*" -O and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

E" . VV d2 Commissions NC 978 Inspector's Signature

Date _S -15 _,20_ (o

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 107: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( ( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/19/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C LD DIESEL GENERATOR LUBE OIL SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Tdentification of Comnonent~q Rernaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

"]2 L-I 3 D Shared (specify Units[-] )

17420-06

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped ____ _(yes or no)

A U-Bolt For Hanger 1-A-LD-3000 REPLACEM]

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 108: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Restore Support 1-A-LD-3000_

8. Test Conducted: Hydrostatic I-- Pneumatic E--] Nominal Operating Pressure D Pressure psig Test Temp. deg.F.

Other F Exempt 2

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

signed TECH SPEC Date 20 e) /Sig wner or Owner's Designee, Title

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 16 - )- -00 to 1. II- /1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

em ,Commissions NC 978

Ipector's Signature

Date _ [- I t _,20_0 )

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 109: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

/ (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/25/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit M 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE fi Tchntific~tion of Cornnonent,• Renaired or Rernlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

"]2 [-- 3 [ Shared (specify UnitsD-] )

79610-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Snubber PSA 5486 1-R-ND-596 1979 REPLACED

B Snubber PSA 17604 1-R-ND-596 1983 REPLACEM

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 110: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) 'information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace 1 -R-ND-596_

8. Test Conducted: Hydrostatic 0 Pneumatic [ Nominal Operating Pressure 57 Pressure psig Test Temp. deg.F.

Other [] Exempt E

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed o c &'

/

Expiration Date N/A

Date /Z.' ,19 2fOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _- -S-'_ to 8-So); and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

_ ____Commissions NC 978 Inspector's "Signature

Date _ " " -,19_ -

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 111: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/25/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit ] 1 E" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6i Tdentification of Corn orients Rernaired or Renlacement Cormnonents

Section E Exhibit A

Sheet 1 of 1

"]2 "] 3 E] Shared (specify Units- )

79611-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number (yes or no)

A Snubber PSA 3448 1-R-ND-226 1978 REPLACED

B Snubber PSA 40121 1-R-ND-226 1998 REPLACEMI

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

f/

Page 112: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace 1-R-ND-226_

8. Test Conducted: Hydrostatic E' Pneumatic - Nominal Operating Pressure Pressure psig Test Temp. deg.F.

Other--] Exempt M

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed M Z" Owner or Owner's Designee, Title

Expiration Date N/A

Date •/ ,19 T, 1

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period )-IS)' to 8-Uiz_; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

f•o i (• Commissions NC 978 Inspector's Signature

Date '6- • -- ,19_q' -

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 113: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/19/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit X 1 EI Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System SA MAIN STEAM SUPPLY TO AUX EQUP Class B 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Comnonents Repaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

12 [-D 3 [-] Shared (specify Units' )

80588-01/04

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped (yes or no)

A Bonnet Borg Warner 62 For valve tag #1SA004 REPLACED

B Bonnet Borg Warner 211805 For valve tag #1SA004 REPLACEM

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

t k/

Page 114: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Repair Valve 1SA004_

8. Test Conducted: Hydrostatic L-- Pneumatic E-- Nominal Operating Pressure [• Pressure 1086 psig Test Temp. 588 deg.F.

Other E] Exempt []

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed / k /I-

Expiration Date N/A

TECHSPEC Date / /9' ,20 o_Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period 10 -D-- 0o to ) -2_- o and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NC 978

Ins ,pector's Signature

Date _\-'2--,20_v A

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 115: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 10/25/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [1 F Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981• Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A e,• f

4 Identification of System YC Control Area Chilled Wtr. Sys. Class 'A., C. 5. (a) Applicable Construction Code I1I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Cornomnents Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

]2 ] 3 - Shared (specify Units-- )

81579-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number (yes or no)

A Control Room Carrier 700423 140425 Screw Cap-SA193 forControl Room 1978 REPLACEM] Area Chiller Area Chiller 1CRA-C- 1

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of2 Revision 6

k

Page 116: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Clean/Inspect Condenser_

8. Test Conducted: Hydrostatic [] Pneumatic [- Nominal Operating Pressure EPressure psig Test Temp. deg.F.

Other - Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

/

Expiration Date N/A

TECH SPEC Date 1^1--5" ,19FOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period _-*S(1 to t Zp:L•and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing thJs certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

InSpe'or's, Signature

Date _•%D- .__,19 -110

Commissions NC 978

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit A

Page 117: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/03/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 0 1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # n/a Expiration Date N/A

4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM 5. (a) Applicable Construction Code 1m1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 [-' 3 R Shared (specify UnitsL-] )

83683-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Snubber Pacific 10012 For hanger 1-R-ND-0268 1979 REPLACED Scientific

B Snubber Pacific 3602 For hanger 1-R-ND-0268 1977 REPLACEM Scientific

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 118: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work hR 1-R-ND-0268_

8. Test Conducted: Hydrostatic [" Pneumatic L] Nominal Operating Pressure El Pressure psig Test Temp. deg.F.

Other[] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed A z g• TECH SPEC Date / , 19__f .. .wuier or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 9-21-99 to #L 7_and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

M Commissions NC 978 Inspector's Signature

DateI I- R ,19_'Z )

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 119: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/09/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 0 1 L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981) Address 526 S. Church St. Charlotte, N.C. 28201-1006 98/ Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of SystemVG-D/G Starting Air System Class C 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

(Section E Exhibit A

Sheet 1 of 1

]2 [-'] 3 ' Shared (specify UnitsD-- )

83816-01 7ZJzt/- 0/

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Pipe Duke Power C-1VG 95 For D/G Engine Starting Air Aftercooler REPLACEM Co. "2B"

B Pipe welds Duke Power C-lVG 95 Weld # 1VG1212.03-003-0Ol-1B2-11 REPLACEM' Co. and 12

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 120: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2in. x 11 in. (2) "information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Repair VG Aftercooler "2B"_

8. Test Conducted: Hydrostatic IE Pneumatic - Nominal Operating Pressure L, Other Fi-- Exempt [] Pressure 77 psig Test Temp. 80 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

/

Expiration Date N/A

Date .19_.2

owner or uwner s i,'eslgnee, I ule

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period ;-2.9 AA9 to 8"-209; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

krt.}kYffl"4LL Commissions NC 978 Inspector's Signature

Date_$" 2ý __ , 19J_) _-

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit A

Page 121: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(If

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY I a Date 08/09/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Z 1 V Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 81/ Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System KC COMPONENT COOLING SYSTEM Class C 5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com nonents Renaired or Renlacement Components

Section E Exhibit A

Sheet 1 of 1

]2 - 3 - Shared (specify Units- )

83818-01 '9,,179-CS

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Pipe Weld Duke Power C-1KC 129 Weld-lKC928-25 REPLACEM] Co.

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 122: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) "information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work I/R Oil Cooler_

8. Test Conducted: Hydrostatic Es Pneumatic [ Nominal Operating Pressure Z Other i[ Exempt E] Pressure 92 psig Test Temp. 88 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Si ned A/.n) S, Ave

Expiration Date N/A

Date , 19 5?Owner'or Owner's Difsignee, Title

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Provindence of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 65-7 -'))_ to B .-9_; and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

P "v,4 - •V Commissions NC 978 Inspector's Signature

Date _l&)) -19_-'

! T _

Form NIS-2 ( Back) Section E Exibit A

b

Page 123: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 10/28/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [i E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981; Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of SystemVG-DG Starting Air System Class C 5. (a) Applicable Construction Code 1II 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Comnonents Renaired or Ren~lacement Components

Section E Exhibit A

Sheet 1 of 1

12 F] 3 F-1 Shared (specify UnitsL-l )

84340-06

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number(yes or no)

A DG Starting Air Process F-01378 5314 Replace endbell and nozzles to 1979 REPAIRED Aftercooler IB1 Engineering aftercooler with material listed below

B Pipe Duke Power C-1VG 95 6" pipe-SA106, Flange-SA105, Plate- REPLACEM] Co. SA516

C Pipe welds Duke Power C-lVG 95 1212.03.003-001-lB 1-11,12 REPLACEM] Co.

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

k

Page 124: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Endbell and Nozzles for Aftercooler IB 1_

8. Test Conducted: Hydrostatic [] Pneumatic -- Nominal Operating Pressure Z Other [ Exempt E] Pressure 71 psig Test Temp. 69.1 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of uthorization No. N/A

SignedM

/

Expiration Date N/A

TECH SPEC Date ,19 ?,Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Comnany of Hartford Connecticut have

inspected the components described in this Owners Report during the period 9-2J-L)'9 to l/-P)9 and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

inspection. _1 M_ _ __ _ Commissions NC 978

Inspector's %lgnature

DateL - ,1 9-,0 9 _

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit A

Page 125: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 11/16/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 01 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/1, Expiration Date N/A

4 Identification of SystemVG-DG Starting Air System Class C 5. (a) Applicable Construction Code II 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Identification of Con onents Renaired or Renlacement Components

Section E Exhibit A

Sheet 1 of 1

12 F-D 3 -- Shared (specify Units[] )

84517-06

L

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stamped

Number_ (yes or no) A Endbell Process F-01178 5313 DG Aftercooler"1Al" 1979 REPLACED

Engineering

B Pipe Duke Power C-1VG 95 6" Pipe-SA106, Flange-SA105 welds- REPLACEM] Co. 1212.03-003.001-1A1-1 1,12,BMR1

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

/ !

Page 126: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I 1 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Endbell for DG Aftercooler IAI_

8. Test Conducted: Hydrostatic El Pneumatic LI Nominal Operating Pressure [^ Other ED Exempt El Pressure 74 psig Test Temp. 72 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed TECH SPEC Date /4& 19__ _ 7 OwnierOwner 's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Comnany of Hartford Connecticut have

inspected the components described in this Owners Report during the period _-/____ to ) and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

•jy'•r• .'V\LUJCommissions NC 978

Inspector's Signature

Date_ A ),19_ý (

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 127: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

f ( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/15/99 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 91 L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 9811 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System VG- DG Starting Air System Class C 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

( Section E Exhibit A

Sheet 1 of 1

]2 :13

84526-05

[ Shared (specify Units[:] )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Endbell Process F-0127B 5314 Endbell for DG Aftercooler "1A2" REPLACED Engineering

B Pipe Duke Power C-1VG 95 6" Pipe-SAl06, 6" WN Flange- SA105 REPLACEM] Co.

C Pipe Welds Duke Power C-1VG 95 1212.03-003.001-1A2-41,12 REPLACEM] Co.

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

k

Page 128: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Endbell and Nozzles_

8. Test Conducted: Hydrostatic -- Pneumatic -Nominal Operating Pressure Pressure 75 psig Test Temp. 68 deg.F.

Other ] Exempt L1

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

/

Expiration Date N/A

TECH SPEC Date j// -,19__Owfiier or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period) -D'I) to ILLI(nand state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

2 KL L , V'\v•_ 4/& Commissions NC 978

Inspector's Signature

Date I1.\_ ,19 __

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 129: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( •,,

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 05/25/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981i Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System SA MAIN STEAM SUPPLY TO AUX EQUP Class C 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE T de.ntificntinn of Comrnonent,• Renaired or Renlacement Comnonents

/

Section E Exhibit A

Sheet 1 of 1

]2 0 3 7 Shared (specify UnitsL-- )

36758-02

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped

.. (yes or no)

A Weld #1SA6J- Duke Power C-1SA 114 This weld is to weld stud to disk for REPAIRED 220 Co. valve 1 SA-007

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

k

Page 130: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Repair Disc Assembly for 1 SA-007_

8. Test Conducted: Hydrostatic El Pneumatic [ Nominal Operating Pressure L"- Other LII Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed L . ý

/

Expiration Date N/A

TECH SPEC Date •h1f ,20 oc::O•,n&-"r Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 11 -9 9 to "_ .--d and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

_ _ _ _ _ _Commissions NC 978 Inspector's Signature

Date_ ,2OQ)

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 131: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/14/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit H1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 981' Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6z Tdlontification of flomnonent~q Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

12 R 3 R- Shared (specify Units[:] )

92121-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Cohumn 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Valve Disc ITT Eng. 89584-31-3- For valve tag 1RN-D032 1990 REPLACED 2

B Valve Disc ITT Eng PN12860 For valve tag 1RN-D032 REPLACEM]

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 132: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Repair Valve Seat_

8. Test Conducted: Hydrostatic D Pneumatic "] Nominal Operating Pressure Pressure psig Test Temp. deg.F.

Other E] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed/"Z4 7 - Owner or Owner's Designee, Titil

Expiration Date N/A

TECH SPEC Date Z 4-' 20_•_

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 1'-2.4-e,0 to 11',14-W( and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Inspector's Signature

Date_ 1"4,20_ U _

Commissions NC 978

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 133: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/09/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit N i E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CN Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Co ponents Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of +

12 [] 3 [] Shared (specify UnitsD-- )

13411-01 98240938-03

11396

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number(yes or no)

A Pipe Duke Power C-1RN 117 8"Pipe-SA106,SA312,SB675 2"Pipe- REPLACEM] Co. C-1CA 121 SA376, SA106

B Pipe Fittings Duke Power C-1RN 117 8" 90 Ell-SA234,SA105,SB366 8: 45 REPLACEM. Co. C-1CA 121 Ell-SA105 8x6 Red-SA105

C Pipe Fittings Duke Power C-1RN 117 2" H/Cplg.-SB462 2" Cap-SA105 REPLACEM Co. C-lCA 121 8"Pipe Cap-SA234

D Pipe Flanges Duke Power C-1RN 117 8" SO Flange-SA105,SB462 REPLACEM] Co. C-1CA 121

E Bolting Duke Power C-1RN 117 Studs-SA193 Nuts-SA194 REPLACED Co. C-1CA 121

F REPAIRED

Page 1 of 2 Revision 6

Page 134: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

: ( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/09/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 01 E" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CN Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases . (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE

6. Identification of Com ponents Repaired or Replacement Components

Section E Exhibit A

Sheet Z.of 41

"]2 [-] 3 F-1 Shared (specify UnitsE] )

13411-01 98240938-03

11396

Column 1 Column 2 Column 3,ý Column Column 5 Column Colmn 7 Column _ _ _ _ _ _4 _ _._ _ _ _ _6 .8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Ceeril Replacement Stamped

Number _(yes or no) A Valve BNL A-981103-9- 2" Ball Valve tag #1RNE97 1999

B Valve Flowserve EOOIT-1-1 2469 8" Gate Valve tag#1RN250A 2000

C Valve Fisher 94562-01A 339 10" Butterfly Valve tag #1RNE95 1997 IAElP.•

D Strut Grinnell 41-41118 1-R-CA-316 2000-32 Me___ __ _

E Strut Grinnell 41-41118 1-R-CA-316 PAE D2000-31 _ _,/e '

F Strut Grinnell 41-29788 1-R-CA-319 _ _ _ 1997-91 'A/le Z,_

Page 1 of 2 Revision 6

Page 135: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/09/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 [ Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CN Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 3 of *

12 -- 3 E:- Shared (specify UnitsD )

13411-01 98240938-03

11396

Column 1 Column 2 Column 3 Column Column 5 Columni Column 7 Column 14 _6 8 Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code NumerReplacement Stamped Number _(yes or no)

A Clamp Fig. 640N For Hangers 1 -R-CA-316, 1 -R-CA-319

B Clamp Fig. 295N For hangers 1 -R-CA-317, 1 -R-CA-318 RE'f-A'JýD

C Snubber Pacific PSA-3 1-R-RN-253 1981 RZAMR1a Scientific 19963 D__/e__ _ _ _

D Strut Grinnell 1993-167 41- 1-R-RN-231 1993 15675 ZDe/e&4ed

E Strut Grinnell 1-R-RN-233 1Ef'f Ev.

REPAIRED

Page 1 of 2 Revision 6

Page 136: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/09/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CN Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE STdo~ntficntion of Cornomnent,• Renaired or Renlacement Comn onents

Section E Exhibit A

Sheet 4 of/-f

]2 F- 3 F-1 Shared (specify Units[- )

13411-01 98240938-03

11396

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Pipe Welds Duke Power C-1RN 117 1RN182-26 1CA146-44,48,50 REPAFED Co. C-1CA 121 1RN542-1,2,3,4,5,6,7,8,10,11 I____..

B PipeWelds DukePower C-1RN 117 1RN181-40 1RN182-27,28,29,30 Co. C-1CA 121 1CA146-43,45,47,49,51 _ Ae a.,,

C Hanger Welds Duke Power C-iRN 117 1-R-CA-319-3 1-R-CA-318-1 1-R-CA- RE9fi-, Co. C-1CA 121 317-1 1-R-CA-316-4,3,2,1 A•eeJa _

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

((

Page 137: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Install 1 RN25OA at RN Header & Change to 8"_

8. Test Conducted: Hydrostatic II Pneumatic -l Nominal Operating Pressure Pressure 55 psig Test Temp. 65 deg.F.

Other E- Exempt El

9. Remarks Functional completed on work orders 98213411-07 & 27

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed 1. A 4/

Expiration Date N/A

TECH SPEC Date 1/1Z7 _,20 00Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 8 Z -00 to I 1` 0 - 0 7> and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Q- U" \, A) Commissions NC 978 Inrspector's Signature

Date \" ,20_ C7 __

Page 2 of 2 Revision 6

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

Page 138: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/16/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Piant CATAWBA NUCLEAR STATION 2a Unit I 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CN Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code I.i 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

-2 E] 3 E] Shared (specify UnitsDj )

13414-01 98240944-03

11396

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Valve BNL A981103-9-4 For valve tag #1RNE98 5/99 REPLACEM'

B Valve Flowserve EOOIT- 1-2 2470 For valve tag # 1 RN3 1OB 2000 REPLACEM'

C Valve Fisher 91944-30B 336 For valve tag # 1RNE93 1997 REPLACEM.

D Pipe Welds Duke Power C-lRN 117 1CA154-3,7,23,1718,19,20,21,22 REPLACEM Co. C-1CA 121 1CA153-36 1RN217-29,30,31,32,33

E 1RN1 11-31,32,36,33,27,28,29,30,34 REPAIRED 1CA154-1,6,8,9,10,11,12,13,14,15,16

F REPAIRED

Page 1 of 2 Revision 6

Page 139: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/16/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit i1 LAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CN Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Identification of ConnnsRenaired or Renlacement Comnonents

S

Section E Exhibit A

Sheet 1 of 1

"12 - 3 [] Shared (specify Units- )

13414-01 98240944-03

11396

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A 8" Pipe Clamps Grinnell For hangers 1-R-CA-372, 1-R-CA-371 Fig. 295N & 1-R-CA-375 _ _____

B 8" Pipe Clamps Grinnell For hangers 1-R-CA-374, 1-R-CA-375 Fig. 640N M/et_,.)

C Sway Strut Grinnell 41-16815 For hanger 1-R-CA-375 RERLAZEN Il/e t

D Sway Strut Grinnell 41-17583 For hanger 1-R-CA-374 leE-JA-Q-EM Ale ,,j

E Bolting Rod- SA193 HexNuts-SA194

F i/$ e,,, l , t C,,,? /," /-.a.,l -37 - ,, Lq..?1/fC,•. i-c /_. -RU.) .37', J •za -,,•¢,-'37"'-1 ___ _____ __.

Page 1 of 2 Revision 6

Page 140: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/16/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 01 E" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CN Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

"12 E] 3 [] Shared (specify UnitsD- )

13414-01 98240944-03

11396

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Pipe Duke Power C-IRN 117 8" Pipe- SB675, SA106 2" Pipe- REPLACEM Co. C-1CA 121 SA376j,

B Pipe Fittings Duke Power C-1RN 117 8" 90 ell-SB366, SA234 & 45 ell- REPLACEM Co. C-1CA 121 SA234 2" H/Cplg.- SB462,6'1b-5s41O-._

C Pipe Fittings Duke Power C-1RN 117 2" Pipe Cap-SA106 8x6 Red.-SA234 8" REPLACEM Co. C-1CA 121 SO Flange-SB462,SA105

D Bolting Hex Nuts-SA194, Studs-SA193 REPLACEM

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 141: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Install IRN3 103B at RN Header & Change to 8"_

8. Test Conducted: Hydrostatic [IZ Pneumatic 1: Nominal Operating Pressure Z Other [D] Exempt El Pressure 74 psig Test Temp. 65 deg.F.

9. Remarks !q"e7 o-J dO47A/e/•/ o.9 gdJo,, 6-J 5 - 9d?31Ilt-. 7 -".

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed la&

Expiration Date N/A

TECH SPEC Date J4 7 _,2040Owner or Owner's Designee, Title

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 5" - o0o0 to It" 00 -00and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Pi •- Vk ' M tu Commissions NC 978 ' Inspector's Signature

Date 3 kJ, D ,20Q0 ___

Formi NIS-2 (Back) Section E Exibit A

Page 142: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 02/14/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 01 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of SystemVG-Diesel Generator Starting Air Sys. Class C 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Td•.ntif~icntinn nf~Cnmnonent.• PenAired or Renlacement C~omnonent.•

Section E Exhibit A

Sheet 1 of 1

]2 [- 3 [] Shared (specify Units- )

13428-01/04

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped _________________________________ _________ _________(yes or no)

A End Cover Duke Power For VG Aftercooer "1B2" Cover-SA516 REPLACEM. Co. Gr.70 fl

B Weld Duke Power C-1VG 95 Weld #1212.03-003.001-1B2-11 REPLACEM. Co.

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2

Revision 6

Page 143: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I 1 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace End Cover_

8. Test Conducted: Hydrostatic [- Pneumatic [- Nominal Operating Pressure Other L] Exempt E] Pressure 77 psig Test Temp. 39 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of uthorization No. N/A

SignedM /rZ

/

Expiration Date N/A

TECH SPEC Date __k/ ,20OOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 1I-n.41 to 2-- M1OL'and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

nspector's Signature

Date 2•- i_ ,200_ _

Commissions NC 978

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 144: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 02/03/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 E" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of SystemVG- Diesel Gen. Starting Air Sys. Class C 5. (a) Applicable Construction Code E11 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Tden~tifiention nf flomnonent• Renaired or Renlacernent Comnonent•

(

Section E Exhibit A

Sheet 1 of 1

"]2 - 3

13433-01

E] Shared (specify Units- )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped N_(yes or no)

A Plate Duke Power SA516 Gr. 70 for VG Aftercooler "IA' REPLACEM] Co.

B Weld DukePower C-1VG 95 Weld#1212.03-003.001-lA1-11 REPLACEM] Co.

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 145: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace End Cover_

8. Test Conducted: Hydrostatic L' Pneumatic D Nominal Operating Pressure [• Pressure 75 psig Test Temp. 47.7 deg.F.

Other E] Exempt 1:1

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed 1d g ,eA • TECH SPEC €/ Owner or Owner's Designee, Title

Expiration Date N/A

Date Z? ,200 C. If

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Comnany of Hartford Connecticut have

inspected the components described in this Owners Report during the period I ?-I -- 1- to 2..-b-0 ) and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

NC 978Commissions

Inspector's Signature

Date _9- tý__ ,200-o

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 146: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( -oection XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/03/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit M 1 IF Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C NV CNEMICAL VOLUME CONTROL SYSTEM 5. (a) Applicable Construction Code 1I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

(Section E Exhibit A

Sheet 1 of 1

-2 3 Ij Shared (specify Units[:] )

26882-03

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Bolting Studs-SA 193, Hex Nuts-SA 194 for REPLACEM] Boric Acid Tk. Manway Cover

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 147: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) "information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Inspect/Clean Boric Acid Tank_

8. Test Conducted: Hydrostatic l ]Pneumatic 1-1 Nominal Operating Pressurer Pressure psig Test Temp. deg.F.

OtherF -Exempt Z

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed oe/

Expiration Date N/A

TECH SPEC Date _,20

Owner or Owner's Des'ignee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period l/ -?) -Ob to I - /I- 0 ) and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NC 978Inspector's Signature

Datej_ V,1 -_,20_01 _

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 148: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/04/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 0 1 E' Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CN Expiration Date N/A

4 Identification of System Class C NV CNEMICAL VOLUME CONTROL SYSTEM 5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

-2 [- 3

23759-01

CE 61684

F-1 Shared (specify Units- )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stamped Number_ (yes or no)

A Bolting Threaded Rod-SA193, Hex Nuts-SA194 REPLACEM] for Mixed Bed Demin. Strainer

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

!i

Page 149: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work R/R Strainer

8. Test Conducted: Hydrostatic E- Pneumatic[] Nominal Operating Pressure Eli Other El[ Exempt Z Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed o A,, f TECH SPEC - Owner or Owner's Designee, Title

Expiration Date N/A

Date 4k ,200 /

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period I[- 4- 00 to /-// * and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _te•_ A % y_ Commissions NC 978 Inspector's Signature

Date J - I ) ,20-0 1

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 150: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/18/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit H 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Co ponents Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 E] 3 E] Shared (specify Units- )

31311-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stamped

Number _(yes or no)

A Ball Grinnell For valve 1RN020B REPLACEM]

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 151: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

"information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work I/R Leak on Valve I RN020A_

8. Test Conducted: Hydrostatic [-1 Pneumatic L-i Nominal Operating Pressure U-Pressure psig Test Temp. deg.F.

Other E- Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

/

Expiration Date N/A

TECH SPEC Date / _,, -,20# eoLiwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period [ 1-2-- 00 to ( I O-O and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

& M. " Commissions NC 978

Inspector's Signature

Date J - _,20_o I

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 152: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section Xl

1. Owner DUKE POWER COMPANY la Date 06/26/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit ' E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982L Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System WZ Groundwater Drainage Sys. Class C 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

"]2 F] 3 [-- Shared (specify Units-] )

H1300-02

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Pump Crane NSP-001298 33 Aux. Bldg. Groundwater Sump 1978 REPLACED Pump" 1 B"

B Pump Crane 98JC 19015 N/A Aux. Bldg. Groundwater Sump Pump 1999 REPLACEM "1B"

C Bolting Stud-SA 193, Nuts-SA 194 REPLACEM

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

k

Page 153: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I I in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets

is recorded at the top of this form.

7. Description of Work Replace Aux. Sump Pump "IB"_

8. Test Conducted: Hydrostatic [] Pneumatic [ Nominal Operating Pressure [] Other [] Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed TECH SPEC Owner or Owner's Designee, Title

Expiration Date N/A

Date .,200

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 4,211•4. to -) 3"- 3e and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ff/•i '4, Commissions NC 978 Inspector's Signature

Date-)-3 _,20_--V _

Page 2 of 2 Revision 6

Section E Exibit AA S ME Section XlI Manual Form NIS-2 ( Back)

Page 154: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 05/30/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Hi E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982, Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System WZ- Groundwater Drainage Sys. Class C 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Tdanti f'i ctinn nf Cnm nonent• R e~naired or R enl acement Cornnonents

( Section E Exhibit A

Sheet 1 of 1

]2 [13

41300-08

D Shared (specify UnitsD-- )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Bolting Studs-SA 193, Nuts-SA 194 for hanger 1- REPLACEM] A-WZ-3031

B Bolting Studs- SA193, Nuts- SA194 for hanger REPLACEM' 1-A-WZ-3032

C Bolting Studs- SA193, Nuts-SA194, Hex Bolt- REPLACEM] SA325 for hanger 1-A-WZ-0004

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

k

Page 155: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x 11 in. (2) "• information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work I/R Pump_

8. Test Conducted: Hydrostatic r1- Pneumatic [: Nominal Operating Pressure [I Pressure psig Test Temp. deg.F.

Other El Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed i/z.€ ) J TECH SPEC SOwKr or-Owner's Designee, Title

Expiration Date N/A

Date 3 0 ,20oc

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period A ,,) '- Cs to ti. " .o and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

iDs " •PLA Commissions NC 978 ector's Signature

Date J_. I _-,20_0 J _

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit A

Page 156: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

i ( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 05/25/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 0 1 LAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

(

Section E Exhibit A

Sheet 1 of 1

]2 D 3

52512-01

- Shared (specify UnitsD )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

ComonntReplacement Stamped Number _(yes or no)

A Disc (2) Anchor- For valve tag #1NV337 REPLACED Darling

B Disc Anchor- For valve tag #1NV337 REPLACEM] Darling

C REPAIRED

D REPAIRED

E REPAIRED

IF REPAIRED

Page 1 of 2 Revision 6

Page 157: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work I/R Valve 1NV337_

8. Test Conducted: Hydrostatic E] Pneumatic El Nominal Operating Pressure E-1 Pressure psig Test Temp. deg.F.

Other [-] Exempt E

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed // &ý

Expiration Date N/A

TECH SPEC Date _, ,20o 6

/ Owner or Owner's Designee, Title

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Comnany of Hartford Connecticut have

inspected the components described in this Owners Report during the period 4'- 00- oO to S -2-S 4,0 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978fInspector's Signature

Date _S-2S __20_01

Form NIS-2 ( Back) Section E Exib it A

Page 158: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/18/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit N 1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class A BB STEAM GERATOR BLOWDOWN SYSTEM 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com onents Repaired or Replacement Components

( Section E Exhibit A

Sheet 1 of 1

12 F] 3 F-1 Shared (specify UnitsD-1 )

54174-37/81

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number (yes or no)

A Pipe Cap Duke Power C-1RN 117 4" Pipe Cap-SA403 REPLACEM Co.

B Weld DukePower C-1RN 117 1RN141-10 REPLACEM Co.

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of2 Revision 6

Page 159: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Install 4" Pipe Cap_

8. Test Conducted: Hydrostatic E- Pneumatic - Nominal Operating Pressure Other [-- Exempt II Pressure 68 psig Test Temp. 64 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

Expiration Date N/A

TECH SPEC Date ,/A/ ,20G

/ Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 10- I- o to - 3-o I and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ _ C Commissions NC 978

Inspector's Signature

Date _ I - T_ ,20_0 __

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 ( Back)

Page 160: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/18/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 EI Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

]2 0 3 [D] Shared (specify UnitsE] )

54174-38

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Bolting Rod-SA193 Hex Nuts-SA194 for valve REPLACEM] 1RNE51

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 161: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) "information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Re-install Valve I RNE5 I_

8. Test Conducted: Hydrostatic [] Pneumatic LI Nominal Operating Pressure IPressure psig Test Temp. deg.F.

Other E- Exempt Z

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

Expiration Date N/A

TECH SPEC Date oZ , _,20-c> .Z

/ Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 10-2D>- 6O to / - 4- 6' and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

___/_ __ Commissions NC 978 crfsp'ktor's Signature

Date - "• _,20_0O I

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 162: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/12/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. plant CATAWBA NUCLEAR STATION 2a Unit • 1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 -13

54174-46

- Shared (specify Units[-] )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped _ .(yes or no)

A Bolting Treaded Rod-SA 193 Hex Nuts-SA194 REPLACEM] for valve 1RN347B

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

f /

Page 163: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Install Refurbished Valve 1RN347B_

8. Test Conducted: Hydrostatic --] Pneumatic -] Nominal Operating Pressure EL Pressure psig Test Temp. deg.F.

Other [] Exempt E

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed " zcw(

Expiration Date N/A

TECH SPEC Date 1Z7///,, 2 00

/ Owier or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 10-2n00 to 1-//-o) and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

U f" La Commissions NC 978 Inspector's Signature

Date _- I ) __ 200 ) _

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 164: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/16/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit i1 " Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 1m1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

"2 ["] 3 - Shared (specify Units[:] )

54174-56

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Bolting Rod- SA193, Hex Nuts- SA194 for valve REPLACEM 1RN225B

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of2 Revision 6

Page 165: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Refurbished Valve 1RN-225B_

8. Test Conducted: Hydrostatic II] Pneumatic "Nominal Operating Pressure [-- Other F"- Exempt Z

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed -ý

/

Expiration Date N/A

TECH SPEC Date ,20 o 6Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Comnany of Hartford Connecticut have

inspected the components described in this Owners Report during the period I 1-6- o) to I I -I ( - o, and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

inspection. Commissions NC 978

Inspector's Signature

Date _\,- ( 1 ,20 () ___

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 166: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/16/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit M 1 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code m11 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE i• Ti-1pntifie'nticmnf(n Afnmnonnt• Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

"]2 [] 3 [-] Shared (specify Units' )

54174-71

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stamped

Number(yes or no)

A Bolting Rod- SA193, Hex Nuts- SA194 for valve REPLACEM]

1RN047A B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 167: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Refurbished Valve I RN-047A_

8. Test Conducted: Hydrostatic E- Pneumatic ] Nominal Operating Pressure [ Other -] Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed - 0ý_ o X2 TECH SPEC Date j/-,20 Z

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period I I -(,- ou to I I/- /6U and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

1ý j 9 V/I -A-, Commissions NC 978

Inspe:ctor's Signature

Date _-\-L_ ,20_(U ) _

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 168: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/16/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit M1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982; Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code II 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE A TIdrntflf'i-.tinn cbff-.mncnent. Renaired or Renlacement Comfonents

Section E Exhibit A

Sheet 1 of 1

12 I-] 3 F] Shared (specify UnitsL-] )

54176-32

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Bolting Rod- SA193, Hex Nuts- SA194 for valve REPLACEM 1RN287A

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 169: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Refurbished Valve I RN287A_

8. Test Conducted: Hydrostatic El Pneumatic [ Nominal Operating Pressure 0] Other F1- Exempt Z

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed _ _a-Z

Expiration Date N/A

TECH SPEC Date 4/ 200,oOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period t 0 -21-cx- to I I° / &6'O' and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

Da spector's Signature

Date AY\ _ 20_ C, 0

Page 2 of 2 Revision 6

q

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

ýLjk VIA t

Page 170: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/15/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Piant CATAWBA NUCLEAR STATION 2a Unit E 1 I Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE C TdEntification of Com onents Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

]2 n-] 3 - Shared (specify Units- )

54176-38

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Bolting Threaded Rod-SA 193, Hex Nut-SA194 REPLACEM]

for valve 1RN-067A

B REPAIRED

C REPAIRED

D REPAIRED

El REPAIRED

F REPAIRED

Page 1 of2 Revision 6

Page 171: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Reinstall valve 1 RN-067A_

8. Test Conducted: Hydrostatic El Pneumatic E Nominal Operating Pressure El Pressure psig Test Temp. deg.F.

Other El Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed - TECHSPEC Date - ,200_ Z4 4 ,or Owner's Designee, Title

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 10- -oo to I - IJ• --') and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

' Commissions NC 978

Inspector's Signature

Date _ - [1, ,20Oc __

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 172: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/11/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 91 F[ Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code II 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

"12 - 3 - Shared (specify Units-- )

54176-49/85/42

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped (yXes or no)

A Pipe Duke Power C-1RN 117 2" Pipe- SA312 REPLACEM e

Co.

B Pipe Welds Duke Power C-1RN 117 1RN144-50,51,53,54 IRN180-31 REPLACEM] Co.

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 173: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Clean RN Piping_

8. Test Conducted: Hydrostatic El1 Pneumatic [I] Nominal Operating Pressure Other [0 Exempt L Pressure 72 psig Test Temp. 68 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed TECH SPEC Date /Z _,20 o0/ Owner or Owner's Designee, Title

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 0-'K•'0 to 1"8 "01 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

_ _ _ _ _ Commissions NC 978

Inspector's Signature

Date _ I-E) _,20O __

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 174: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

I(

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/16/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit l1 FAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982, Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE i• Trtpntifir~tiln nC~nmnnnn~nt'• Ren~ired nr R enlaeement Comnnonent~q

Section E Exhibit A

Sheet 1 of 1

]2 - 3 E] Shared (specify Units[-- )

54176-52

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Bolting Rod- SA193, Hex Nuts- SA194 for valve REPLACEM] 1RN048B

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 175: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Refurbished Valve 1 RN048B_

8. Test Conducted: Hydrostatic [] Pneumatic l'-- Nominal Operating Pressure Eli Pressure psig Test Temp. deg.F.

Other -] Exempt ED

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Page 2 of 2 Revision 6

Expiration Date N/AType Code Symbol Stamp N/A

Certificate of Authorization No. N/A

TECH SPEC Date / 20 6)SignedOwner-or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period IL' 2q-64/ to /I - (• -6? and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

(O-ttA YAq%4 Commissions NC 978

Inspector's Signature

Date IV"16_,20_ 1)

, A 4 A,-; ý', 4 Z e

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 176: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/16/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit i1 EI Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6~ ldentificntion of Co.mnonent.• Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

12 [-] 3 [-] Shared (specify Units- )

54176-71

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Bolting Rod- SA193, Hex Nuts- SA194 for valve REPLACEM] 1RN144A

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

(

Page 177: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Refurbished Valve I RN 144A_

8. Test Conducted: Hydrostatic [] Pneumatic - Nominal Operating Pressure []

Pressure psig Test Temp. deg.F.Other [- Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed oAj2

/

Expiration Date N/A

TECH SPEC Date j//6• ,20 66Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period I --2S--u to -I (I &-(/ and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

Ilspector's Signature

Date t-" [_,20_Ov

Page 2 of 2 Revision 6

Section E Exibit AForm NIS-2 ( Back)ASME Section XI Manual

Page 178: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/07/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit N 1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code ITl 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

-2 n 3 - Shared (specify Units-] )

54176-72

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Bolting Rod-SA193, Hex Nuts-SA194 for valve REPLACEM] 1RNE49

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 179: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Reinstall Valve lRNE49_

8. Test Conducted: Hydrostatic [l Pneumatic -- Nominal Operating Pressure L-- Other L-- Exempt Z Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed TECHSPEC Date /a7 -,20 ac) 7 Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 1 Z6, -00- to 1 • & -01 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

_ _ __-a _ _ ý_ Commissions NC 978

Inspector's Signature

Date _ - '6 ,20_0 I

Page 2 of 2 Revision 6

Section E Exibit AForm NIS-2 (Back)ASME Section XI Manual

Page 180: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/13/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 [Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982ý Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Ide~ntification of Cornnonent.s Renairedi or Renlacement Comronents

S Section E Exhibit A

Sheet 1 of 1

12 [ 3 [] Shared (specify Units- )

54178-23

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Bolting Threaded Rod-SA193 HexNuts-SA194 REPLACEM for valve I RNO17

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of2 Revision 6

Page 181: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 l/2in. x 11 in. (2)

"information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Install Refurbished Valve IRNO17_

8. Test Conducted: Hydrostatic [L- Pneumatic -- Nominal Operating Pressure [L-Pressure psig Test Temp. deg.F.

Otherl -Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed Z•A 21?Z&/

Expiration Date N/A

TECH SPEC Date IZ1,0 ,20 D4

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period ) D-0i'"Cb to I - , -o land state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978(tU 'inspector's Signature

Date _t-j) __ ,20O0

Page 2 of 2 Revision 6

Section E Exibit AForm NIS-2 (Back)ASME Section XI Manual

Page 182: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/10/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Il 1 I Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 1I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE •; Tdlntifir~tin fnrn Afononent.• Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

"12 3 [I] Shared (specify Units[ )

54181-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Bolting Threaded Rod-SA193 REPLACEM]

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 183: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"• information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R Section of RN Piping_

8. Test Conducted: Hydrostatic -- Pneumatic E Nominal Operating Pressure EL Pressure psig Test Temp. deg.F.

Other R Exempt M

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed JAZS,7/

Expiration Date N/A

TECH SPEC Date ,200/Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period ) 0"ZS -,0 to 1 -10"o) and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

"__ __ M"_ _i Commissions NC 978

Inspector's Signature

Date - t -13 _,20_0 )_

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 184: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/27/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit N 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Tdontifihntinn of rorno"nent.• Renaired or Renlaeement Comnonent5q

Section E Exhibit A

Sheet 1 of 1

12 D 3 [0 Shared (specify Units[:] )

54181-46

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Bolting Threaded Rod- SA193, Hex Nut- SA- REPLACEM] 194 for valve 1RN232A

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

(

Page 185: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Install Refurbished Valve 1 RN232A_

8. Test Conducted: Hydrostatic [ Pneumatic -- Nominal Operating Pressure [] Other - Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed J4_ ._

Expiration Date N/A

TECH SPEC Date _-,20ocOw~ner -or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period )o -2Z- o & to I - I 1- 0 I and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978fspector's Signature

Date _ i- 11 20_ 0) _

Page 2 of 2 Revision 6

R'" ""-AwI

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 186: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/04/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 EI Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982• Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code EIl 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Identification of Com nonents Renaired or Renlacement Comnonents

( Section E Exhibit A

Sheet 1 of 1

]2 F-1 3 - Shared (specify Units-- )

54181-63

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Bolting Bolt-SA325, Tapper Swing Nuts-SA193 REPLACEM] for Manway M-5-1

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 187: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Install Manway Cover_

8. Test Conducted: Hydrostatic '-1 Pneumatic L-' Nominal Operating Pressure ED Pressure psig Test Temp. deg.F.

Other E- Exempt 2

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

/

Expiration Date N/A

TECH SPEC Date -9,20 9 IOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period J0 - 10 -(X to I - ( I/- - ) and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

)_" _M _ _•• Commissions NC 978

pector's Signature

Date J - 11 _,20-0 1 _

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 188: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/06/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Z 1 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

"12 F-1 3 M Shared (specify UnitsD )

54182-62

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped e _ (yes or no)

A Bolting Rod-SA193, Hex Nuts-SA194, Bolt- REPLACEMI SA325 for Manway M-5-1 & M-6-1

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 189: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I I in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Reinstalled RN Piping_

8. Test Conducted: Hydrostatic 'li Pneumatic E[ Nominal Operating Pressure [• Other [] Exempt []

Pressure 75 psig Test Temp. 44 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed A z

/

Expiration Date N/A

TECH SPEC Date ,20 0/

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period tb>10-0ZD to 1- 1,0I and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

, ,4.,• Yv•¢ 4A9 Commissions NC 978 Inspector's Signature

Date ___"-_,20_ "

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 190: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

/ ( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/04/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Z 1 L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class A RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

]2 -- 3 F-- Shared (specify UnitsD )

54182-91

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number (yes or no)

A Bolting Bolt-SA325& Swing Nuts-SA193 for REPLACEM] Manway M-3-2

B Bolting Studs-SA194 & Hex Nuts-SA193 for REPLACEM. Flanges IRN247-MJ1 & MJ2

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 191: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 1 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R Manway M-3-2_

8. Test Conducted: Hydrostatic 0'' Pneumatic [I Nominal Operating Pressure -' Other -I Exempt Z Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Page 2 of 2 Revision 6

Expiration Date N/AType Code Symbol Stamp N/A

Certificate of Authorization No. N/A

TECH SPEC Date /4/ 20 cOcSignedOwsier or Owner's Designee, Title/

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period I FT- 50 to 12- (6- 0 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

-Q"-I- Cf_ I A Commissions NC 978 Inrspector's Signature

Date j_?- (, - ,20_O(_)

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 192: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/18/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [I ' Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 E 3 [-- Shared (specify UnitsD-- )

54183-22/23

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Pipe Duke Power C-1RN 117 6" CS SA106 REPLACEMI Co.

B Pipe Welds Duke Power C-1RN 117 1RN48-3 1RN48-14 REPLACEM' Co.

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 193: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work R/R Section of 6" RN Piping_

8. Test Conducted: Hydrostatic [-I Pneumatic [-i Nominal Operating Pressure [•] Other -- Exempt LI Pressure 72 psig Test Temp. 68 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed 4 Z~-

/

Expiration Date N/A

TECH SPEC Date _,20oOwner or Owfier's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period /t-9- 0 to ]- 3-0o and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ __ ___ __Commissions NC 978 Inspector's Signature

Date_ I - __ ,20_0 )

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit A

Page 194: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/27/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit ]1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE A TdMntification f Con•onents Renaired or Renlacement Com-onents

Section E Exhibit A

Sheet 1 of 1

]2 E] 3 n-] Shared (specify UnitsD )

54184-21

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

Number (yes or no)

A Bolting Threaded Rod- SA193, Hex Nut- SA- REPLACEM 194 for valve 1RN039

B REPAIRED

C1 REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 195: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 I/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Install Refurbished Valve IRN039_

8. Test Conducted: Hydrostatic -l' Pneumatic n"I Nominal Operating Pressure Other [I Exempt [ Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Expiration Date N/AType Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed _ k_ _ fý

/ Owner or Owner's Designee, TitleTECH SPEC Date ///Z,7 ,20 0O

e

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period I 0 -10- Ob to i - II- o and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

• -•RA Commissions NC 978

Inslpector's Signature

Date J - R _ ,20-0 __

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

Page 196: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

((ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/18/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Z 1 IE Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Co ponents Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

-2 - 3 [--] Shared (specify UnitsL-] )

54184-25

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Bolting Bolt-SA325 Swing Nuts-SA193 for REPLACEM Manway M-8-1 & M-6-1

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

(

Page 197: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Install Manways_

8. Test Conducted: Hydrostatic F PneumaticF1 Nominal Operating Pressure

Pressure psig Test Temp. deg.F.

Other-] Exempt Z

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

/

Expiration Date N/A

TECH SPEC Date J5L2L ,20 0

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period ) 0- ) -.oe> to / -I--o and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

b " .c"Vy Commissions NC 978

Inspector's Signature

Date _I-4 ,20 V) I _

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 198: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/27/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit M1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 1m1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Tdo~ntific~tion o nflnrnnon~ntn Re~n~red or Renlaeement Comnonents

Section E Exhibit A

Sheet 1 of 1

"]2 R 3 -- Shared (specify Units- )

54184-37

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number (yes or no)

A Bolting Threaded Rod- SA193, Hex Nut- SA- REPLACEM] 194 for valve 1RN045

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 199: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Install Refurbished Valve 1 RN045_

8. Test Conducted: Hydrostatic E' Pneumatic E]Nominal Operating Pressure El Other El[ Exempt [ Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed d

/

Expiration Date N/A

TECH SPEC Date -7 ,20 04Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period LI' , -- cc> to I- 6•0 1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ Y__-_ _ C) Commissions NC 978

Inspector's Signature

Date t -j _,200 _0I

Page 2 of 2 Revision 6

Section E Exibit AForm NIS-2 ( Back)

Page 200: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(CASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/30/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit N 1 L" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982:

Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA

Expiration Date N/A 4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE tq Td~ntifictni, of Ccnino nent• Rennired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

"]2 F-1 3 n Shared (specify Units[: )

54184-38

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped

_,_(yes or no)

A Bolting Studs-SA193, Hex Nuts-SA194 for RN REPLACEM] piping spool piece

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 201: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Re-install 20" Spool Piece_

8. Test Conducted: Hydrostatic -- Pneumatic E-' Nominal Operating Pressure El Pressure psig Test Temp. deg.F.

Other[] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

/

Expiration Date N/A

TECH SPEC Date // , 20 a eOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period jV-• - 0O to R, býO - k and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

vtt4A YN\Lf- j Commissions NC 978

Inspector's Signature

Date N1\,, C ,203-) __7

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 202: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(/

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/12/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 I-Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 5 Id~entificaition of Comnnonents Renaired or Renlacement Comronents

Section E Exhibit A

Sheet 1 of 1

]2 R 3 [ Shared (specify UnitsD[] )

54185-21

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Bolting Studs-SA193 Hex Nuts-SA194 for valve REPLACEM 1RN-029

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2

Revision 6

Page 203: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Refurbished Valve IRN-029_

8. Test Conducted: Hydrostatic - Pneumatic [: Nominal Operating Pressure Eli Pressure psig Test Temp. deg.F.

Other - Exempt Z

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed Zg -tz ý

Expiration Date N/A

TECH SPEC Date 20 06

/ Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 1,- 2?3 -ob to I-11 - o0 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

___�m_•_ _ _ _ _ Commissions NC 978

Inspector's Signature

Date _JI- IV _,20_0 1_

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 204: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/04/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit N I EL Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982• Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code m11 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

2 [-13

54185-25

"-D Shared (specify Units[] )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped ______________(yes or no)

A Bolting Bolt-SA325, Swing Nuts-SA 193, Hex REPLACEM

Nuts-SA 194 for Manway M-8-1 B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2

Revision 6

/

Page 205: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R Manway Cover M-8-1_

8. Test Conducted: Hydrostatic rli Pneumatic I-I Nominal Operating Pressure El Other D Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed _&0I.K

/

Expiration Date N/A

TECH SPEC Date 20/Z/" 20 oc)Owneror Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company o4 Hartford Connecticut have

inspected the components described in this Owners Report during the period I -0-,L W _ to _-&,- ct and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

s________a__A_ _ Commissions NC 978 Ins~ector's Signature

Date _\ - • ,20_ cu _

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 206: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/06/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit X 1 [E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Identification of Con onents Renaired or Renlacement Comnonents

I,

Section E Exhibit A

Sheet 1 of 1

]2 F1- 3 -] Shared (specify Units- )

54185-37

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number __ (yes or no)

A Bolting Rod-SA193, Hex Nuts-SA194 for valve REPLACEM] 1RN-034

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 207: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Install Refurbished Valve_

8. Test Conducted: Hydrostatic [l Pneumatic El Nominal Operating Pressure L-' Pressure psig Test Temp. deg.F.

Other [L] Exempt M

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed & eý

/

Expiration Date N/A

TECH SPEC Date /_ " ,20 e 6Owneifor Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 10 -2-oZUD to ) - 0 - ;N f and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

"-X )M,( a Commissions NC 978 Inspector's Signature

Date _t -5 _,20_0 1 _

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 208: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/04/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit F1 i E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

S E

Section E Exhibit A

Sheet 1 of 1

2 0-- 3 F-- Shared (specify Units[:] )

54185-64

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Numbr ________(yes or no)

A Bolting Studs-SA193, Hex Nuts-SA194 for REPLACEM flange joint MJ-4

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 209: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R Flange Joint_

8. Test Conducted: Hydrostatic [ Pneumatic E] Nominal Operating Pressure El" Other n-] Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed TECH SPEC Date j/•, 0SL Owner o•rOwner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 10 -2D -Ob to 1- 1 1- o and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

___________Commissions -NC 978 Inspector's Signature

Date J,- 0 _,20O_ __

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 210: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/18/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 jAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982. Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 1II 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

(

Section E Exhibit A

Sheet 1 of 1

-2 [: 3 [:] Shared (specify Units[:] )

54185-38

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Bolting Rod-SA193 Hex Nuts-SA194 for REPLACEM Manway M-8-1

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 211: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Re-install 20" Spool Piece

8. Test Conducted: Hydrostatic -- Pneumatic L-- Nominal Operating Pressure L-Pressure psig Test Temp. deg.F.

Other I] Exempt E

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Expiration Date N/AType Code Symbol Stamp N/A

Certificate of Authorization No. N/A

/' Owner or Owner's Designee, Title

Date _ I - t 1 ,20 Z? )_

Page 2 of 2

Revision 6

TECH SPEC Date _/4f ,20__e o

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 10 -2-O () to I - J I- (1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

Inspec r's Signature

Section E Exibit AForm NIS-2 ( Back)ASME Section XI Manual

S .one...

Page 212: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/18/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 [Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

-2 [ 3 - Shared (specify UnitsL )

54419-29

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Bolting Rod SA193 Hex Nuts-SA197 for valve REPLACEM 1RN049A 4 ,/j/o/

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

f

Page 213: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x 11 in. (2)

"information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Install Re-furbished Valve _

8. Test Conducted: Hydrostatic F Pneumatic LI] Nominal Operating Pressure [L]

Pressure psig Test Temp. deg.F.

Other - Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed__A,-VP_.

/

Expiration Date N/A

TECH SPEC Date _,j ,20, 9

O-wner or Owner's Designee, Title

Inspector's Signature

Date _ " __ ,20o _l

Page 2 of 2

Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 1 o.-)- ov to I -I- o I and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978Ntl_ýW_4ý

Section E Exibit AForm NIS-2 ( Back)ASME Section XI Manual

Page 214: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/29/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 1 Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

2 [] 3 [] Shared (specify Units[] )

54419-32

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Bolting Threaded Rod- SA193, Hex Nuts-SA194 REPLACEM] for valve 1RN5OB

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page I of 2 Revision 6

(

Page 215: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) "information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Install Refurbished Valve IRN50B_

8. Test Conducted: Hydrostatic El Pneumatic 1- Nominal Operating Pressure ELPressure psig Test Temp. deg.F.

Other -1- Exempt M

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed Zg',- eOwner or Owner's I0esignee, Title

TECH SPEC Date ,20 b 8

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period L- - 2-- 2 to i - 1 -o and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

"Lt Commissions NC 978 Inspector's Signature

Date _- 4 ,200 _)

Form NIS-2 ( Back) Section E Exibit A

Page 216: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 04/05/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 IE Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982' Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System KF SPENT FUEL COOLING SYSTEM Class C 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Comnonents Ren~aired or Renflacement Comnonents

Section E Exhibit A

Sheet 1 of 1

12 [-] 3 - Shared (specify Units[:] )

61320-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code erNumber Replacement Stamped NLes or no)

A Trunion Bolts For Fuel Pool Post Filter "IA" REPLACEM]

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

,

Page 217: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Trunnion Bolts_

8. Test Conducted: Hydrostatic E] Pneumatic E] Nominal Operating Pressure [-i Pressure psig Test Temp. deg.F.

Other [- Exempt Z

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Page 2 of 2 Revision 6

Expiration Date N/AType Code Symbol Stamp N/A

Certificate of Authorization No. N/A

TECH SPEC Date " ,20,00SignedOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Comnany of Hartford Connecticut have

inspected the components described in this Owners Report during the period 3 -S ( -o to 4 -6"1D and state that to the best of my

knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in

accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

em -Commissions NC 978

Inspvetor's Signature

Date _A . (,_ 20_ 0-v __

-/,C&• J V

v-

Section E Exibit AASME Section X1 Manual Form NIS-2 (Back)

Page 218: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 08/29/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Zi L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982( Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System KC COMPONENT COOLING SYSTEM Class C 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Identification of Com onents Renaired or Renlacement Components

Section E Exhibit A

Sheet 1 of 1

"2 [- 3 - Shared (specify Units' )

61887-02

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped (yes or no)

A Disc Pacific Valve 2 N/A Base Metal repair perform on valve disc REPAIRED with item #2B-326

B " REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of2 Revision 6

Page 219: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Repair Disc Assembly_

8. Test Conducted: Hydrostatic - Pneumatic -] Nominal Operating Pressure El Pressure psig Test Temp. deg.F.

Other-] Exempt E

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of uthorization No. N/A

Signed

/

Expiration Date N/A

TECH SPEC Date .5 Z ,20 • o /?JOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 8 -2Ž-c-X, to &•--¢-' and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

IDa spector's Signature

Date -2 20_ -0

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 ( Back)

Page 220: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

CASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/11/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit F1- 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE1 Expiration Date N/A

4 Identification of System KC COMPONENT COOLING SYSTEM Class C 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Tdentification of Comnonents Ren~aired or Replacement Comnonents

Section E Exhibit A

Sheet 1 of 1

12 ' 3 - Shared (specify UnitsD- )

52700-01/02

.0753

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped

_______________ _________________________ (yes or no)

A Valve BIF N44462-20 126 For valve tag #1KC-006 1977 REPLACED

B Valve Fisher 51650-010B 389 For valve tag #1KC-006 2000 REPLACEM]

C Bolting Treaded Rod-SA193, Hex Nuts-SA194 REPLACEM'

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 221: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Valve 1KC-006_

8. Test Conducted: Hydrostatic - Pneumatic 0L Nominal Operating Pressure Other - Exempt ED Pressure 95 psig Test Temp. 75 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed &A 7

/

Expiration Date N/A

TECH SPEC Date ,20 b /Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period lb- 20'- 00n to I- Ii -0 1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

SV1V1%&U Commissions NC 978 Inspector's Signature

Date t- IN __,200) __

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 222: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/04/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Z I-Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982' Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEI Expiration Date N/A

4 Identification of System KC COMPONENT COOLING SYSTEM Class C 5. (a) Applicable Construction Code 1II 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Comnonents Repaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

12 [-] 3 F-1 Shared (specify Units-] )

62701-01/03

10753

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Bolting Studs-SA193, Hex Nuts-SA194 for REPLACEM] valve 1KC-004

B Valve BIF 44462-4 114 Valve tag #1KC-004 1977 REPLACED

C Valve Fisher 5162D-10A 388 Valve Tag #lKC-004 2000 REPLACED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

,/f

Page 223: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

Section E Exibit A

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

"information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace 1KC-004_

8. Test Conducted: Hydrostatic [- Pneumatic E] Nominal Operating Pressure Other - Exempt 0]

Pressure 20 psig Test Temp. 75 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed , /C TECH SPEC Date zZ,65 ,20 0/ / - Owner or Owner's Designee, Title f

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Comnpany of Hartford Connecticut have

inspected the components described in this Owners Report during the period KQ -?O 9 to )- lft 0 1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Inspe•ctor's SignatureCommissions NC 978

Date _) 20_0 D

Page 2 of 2

Revision 6

Form NIS-2 (Back)ASME Section X1 Manual

Page 224: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 09/13/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 I-Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982( Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of SystemVG - Diesel Generator Starting Air System Class C 5. (a) Applicable Construction Code 1I1 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com onents Renaired or Renlacement Components

Section E Exhibit A

Sheet 1 of 1

-2 8 3 F-- Shared (specify UnitsD- )

62706-01/98256042-01/02

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A End Cap Process F-0127B 5314 Diesel Gen. Aftercooler "1A2" 1979 REPLACEM. Equipment

B 6" Pipe & Flange Duke Power C-1VG 95 Carbon Steel SA105/106 REPLACEM Co.

C 3-/' Plate Duke Power C-1VG 95 SA-515 Grade 70 REPLACEM SCo. I

D , -e lx'e/a/s ice C-I-• /c- /e/J /a/&.o3-oi.oe/-/Z-/, REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

k

Page 225: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

- NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I 1 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Endcap _

8. Test Conducted: Hydrostatic E] Pneumatic ,2 Nominal Operating Pressure r--] Other [- Exempt ]

Pressure 70 psig Test Temp. 78 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed i(2A S, II

/ Owner or Owner's Designee, Title

Expiration Date N/A

TECH SPEC Date •L, 20 0 0

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period S" -I D - bo to )"- 14- 00 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

21LkrnrtaInspe tor's Signature

Commissions NC 978

Date 9-l 4 4,20-o'__

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 226: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/15/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Mj 1 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CEE Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com ponents Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 0 3 [-- Shared (specify UnitsL-] )

63347-01

10755

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code ComonntReplacement Stamped Number _(yes or no)

A Valve BIF 44465-5 95 For valve tag # lRN-837 1977 REPLACED

B Valve Fisher 4475B-01 387 For valve tag #lRN-837 1998 REPLACEM.

C Bolting Rod- SA193, Nut- SA194 REPLACEM'

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 227: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace valve 1RN-837_

8. Test Conducted: Hydrostatic n" Pneumatic i] Nominal Operating Pressure [n Pressure 55 psig Test Temp. 67 deg.F.

Other E] Exempt E]

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed " t64 TECH SPEC Date ý//1• ,20 e C) Owner o6rOwner's Designee, Title /

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period /•6- 23- CV to I/- / Go" -and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

Inspector's Signature

Date _4" I ý_,20_-UL),

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 228: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/19/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit N1 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982' Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System CA AUXILIARY FEEDWATER SYSTEM Class B 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6• ITtVntif.i~tion of (rmnonnnnt• Rensiired or R enlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

12 E] 3 ' Shared (specify Units- )

66495-05

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stamped

(yes or no)

A Hanger Welds Duke Power C-1CA 121 1-R-CA-1682-13,12,11,14 REPLACEM Co.

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

/

Page 229: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Restore Support l-R-CA-1682_

8. Test Conducted: Hydrostatic F] Pneumatic - Nominal Operating Pressure -"

Pressure psig Test Temp. deg.F.Other El- Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed /A/~

Expiration Date N/A

TECH SPEC Date /J9 ,20 Oc)

/ Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 5- !7)-ob to - 3- o 1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978tureInspect'r's Signai

Date _ 1 ,__,20 Of

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 ( Back)

Page 230: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/13/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Zi EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982T Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System NI SAFETY INJECTION SYSTEM Class A 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 F-- 3 D Shared (specify Units- )

67772-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped _ Number (yes or no)

A Disc westinghouse 19551307C7 For valve tag #1NI094 REPLACED 9

B Disc westinghouse RP-1002 For valve tag #1N1094 REPLACEM]

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 231: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work I/R Valve 1N1094_

8. Test Conducted: Hydrostatic --- Pneumatic E] Nominal Operating Pressure I-- Other [-] Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

/

Expiration Date N/A

TECH SPEC Date /Z/,J ,2000 1

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period Id -- 2-8 to /- I1I-0 V and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

•-A VAd) e Commissions NC 978 Inspector's Signature

Date 1- l - ,200 _ _

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 232: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/27/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System NI SAFETY INJECTION SYSTEM Class A 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com onents Renaired or Retlacement Components

Section E Exhibit A

Sheet 1 of 1

12 E] 3 F-1 Shared (specify Units-] )

67773-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number(yes or no) A Disc westinghouse M1087-1 For valve 1NI-82 REPLACED

B Disc westinghouse RP-1001 For valve 1NI-82 REPLACEM]

C Bolting Studs-SA453, Hex Nuts-SA453 for REPLACEM valve 1NI-82

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 233: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work I/R Valve 1NI-82_

8. Test Conducted: Hydrostatic El Pneumatic E] Nominal Operating Pressure L-Pressure psig Test Temp. deg.F.

Other [] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Expiration Date N/AType Code Symbol Stamp N/A

Certificate of Authorization No. N/A

SignedOwner or Owner's Designee, Title/

TECH SPEC Date ///Z 7 _,20 0 6

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 6-2S-b-- to 1- I and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

/QL'-&• V'A/-• ,J Commissions NC 978 Inspector's Signature

Date -1 - 6 20 0 1 __

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 234: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/28/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Piant CATAWBA NUCLEAR STATION 2a Unit Z 1 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System NI SAFETY INJECTION SYSTEM Class A 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Comnomnents Repaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

]2 [13

67774-01

- Shared (specify Units- )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number(yes or no)

A Disc westinghouse 1967-1307C For valve tag 1NI71 REPLACED 79-GO1-3

B Disc westinghouse S-74-1947 For valve tag 1N171 REPLACEM]

C Bolting Stud-SA453, Hex Nuts-SA453 for valve REPLACEM 1N171

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 235: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x l1 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Inspect Valve 1N171_

8. Test Conducted: Hydrostatic L- Pneumatic [l] Nominal Operating Pressure E] Pressure psig Test Temp. deg.F.

Other E] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of uthorization No. N/A

Signed Owne or wne's Designee, Title

Expiration Date N/A

TECH SPEC Date ,,20 -0

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 10.30-60 to )-'4-o1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Inspector's Signature

Commissions NC 978

Date _ I 1+_,20_(,- __

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 236: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( KASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/18/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit El L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System NI SAFETY INJECTION SYSTEM Class A 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE C, Identification of Comnonents Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

"]2 [-] 3 F] Shared (specify Units- )

67775-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number(yes or no)

A Disc westinghouse 41671307C- For valve tag #1N160 REPLACED

79

B Disc westinghouse RP-1003 For valve tag #1N160 REPLACEM]

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 237: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Inspect Check Valve 1NI60_

8. Test Conducted: Hydrostatic L] Pneumatic [I Nominal Operating Pressure D Pressure psig Test Temp. deg.F.

Other[] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed dA L t- TECH SPEC Date JZ/,20 oo Owner or Owner's Designee, Title f

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period I v-Jo- o-to to I _ -b- I and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

_ _ _ _ _ _ _ _ _ Commissions NC 978

"I4spector's Signature

Date -I - ,200 I __

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 238: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (.

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/29/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit M i E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM 5. (a) Applicable Construction Code I1I 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 D'i 3 [D] Shared (specify Units[:] )

69305-01,02

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number(yes or no)

A Pipe Duke Power C-1NV 127 2" pipe-SA376, 90 ell-SA182 REPLACEM eo Co.

B Pipe Welds Duke Power C-1NV 127 1NV631-8,9,7 REPLACEM. Co.

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 239: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Retreive Loose Part from 1NV-337_

8. Test Conducted: Hydrostatic -l' Pneumatic [I] Nominal Operating Pressure ,2 Other L] Exempt El Pressure 2445 psig Test Temp. 101.4 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed TECH SPEC / 0wne ,or Owner's Designee, Title

Expiration Date N/A

Date //,/ ,20 _, If

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 6- 1 0- - to / iL4 0 pLand state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

Inspector's Signature

Date _ - 4 _,20_ C I

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 240: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/02/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Zi Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982( Address 526 S. Church St. Charlotte, N.C. 28201-J006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE( Expiration Date N/A

4 Identification of System NF Ice Condenser Refrigeration Class A 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE tq Tde~ntificeation of romnonents Renaired or Renlacement Comronents

Section E Exhibit A

Sheet 1 of 1

]2 [- 3 - Shared (specify Units[-] )

59310-04

1546

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Welds Duke Power C-1NF 88 Weld #Davit Arm-M371,M394 for Co. welding Davit Arm to Penetrations

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 241: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Install Lifting Device_

8. Test Conducted: Hydrostatic D] Pneumatic [-] Nominal Operating Pressure [I[ Pressure psig Test Temp. deg.F.

Other[] Exempt E

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed /• ,,J , TECH SPEC Date //,20 / 4 Owner4 or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 9- / b - 00 to /- 3 ) 1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

-- nsp cto'os Commissions NC 978

Inspector's Signature

Date _ " __ ,20_0 _

Page 2 of 2 Revision 6

Section E Exibit AForm NI S-2 (Back)ASME Section XI Manual

Page 242: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 07/18/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Zi E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982' Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

S,

Section E Exhibit A

Sheet 1 of 1

-2 F] 3 [ Shared (specify Units-] )

71594-03

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped _ Number (yes or no)

A Bolting Bolt- SA325, Hex Nut-A563 for S/R 1- REPLACEM] R-ND-0506

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2

Revision 6

Page 243: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Restore S/R I-R-ND-0506_

8. Test Conducted: Hydrostatic -- Pneumatic -7Nominal Operating Pressure Other L--- Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

/

Expiration Date N/A

TECH SPEC Date P9 2,20 0e)Owfier or-Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 4-/S -Oo to ? -2.0 .- 0 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspcton.

_ _ _ _ _._ Commissions NC 978 'Inspector's ýignature

Date _-')_ 2 -,20_ )o

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 244: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( CASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 05/30/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [I L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System WN- DG Room Sump Pump Sys. Class C 5. (a) Applicable Construction Code 1II 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE A Identification of Con onents Renaired or Renlacement Comnonents

S Section E Exhibit A

Sheet 1 of 1

12 -- 3 F-] Shared (specify Units- )

71865-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Pipe Duke Power C-1WN 90 4" Pipe- SA106, Tee-SA234, Pipe welds REPLACEMI Co. OWN5-16,15

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 245: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Repair WN Piping Leak_

8. Test Conducted: Hydrostatic " Pneumatic -1 Nominal Operating Pressure El Pressure psig Test Temp. deg.F.

Other [] Exempt E

9. Remarks ;/l,4,/,-rnY •-e. k- c e /,, ye•k -S o-7 0 3oa" 0,)C'e-C/ 4-1X.I

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

I Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A Sinned 2 ¢/

/

Expiration Date N/A

SPEC Date & d ,20 6 c)

Ov~ner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period S -9 -&- to S- 30. c,) and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

fns'jector's Signature

Date _S-'b ,20_ oo_

Page 2 of 2 Revision 6

Date

_•-

"5 b_____

,20_

oO

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Si"ed

Page 246: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

C (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/02/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit H 1 LAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 9822 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A s r/Z/6t

4 Identification of System KC COMPONENT COOLING SYSTEM Class .Ae., 5. (a) Applicable Construction Code 1m1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Tdentificntion of romnonent,• Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

]2 FI1 3 " Shared (specify Units-] )

75830-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Disc Pacific SN1 For valve 1KC-005 REPLACED

B Disc Pacific SN2 For Valve 1KC-005 REPLACEM]

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 247: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2) "information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work I/R Valve I KC-005_

8. Test Conducted: Hydrostatic [-- Pneumatic Li] Nominal Operating Pressure -i] Pressure psig Test Temp. deg.F.

Other E] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed 4& 6 (<- st Owner or Owner's Designee, Title

Expiration Date N/A

TECH SPEC Date ella Z,4 ,200

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period 10 -?2o-o to I - 2- - I and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,• AL' A)v Commissions NC 978 Inspector's Signature

Date I -2-- ,20_ 1__

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 248: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/27/00

Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Piant CATAWBA NUCLEAR STATION 2a Unit Zi EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982"

Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA

Expiration Date N/A 4 Identification of System KC COMPONENT COOLING SYSTEM Class C

5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 1 Trlnitfpntlenn nff'onmnnn~nt• P~nniired or Pe~nlweament (',mnonents

S

Section E Exhibit A

Sheet 1 of 1

-2 - 3 - Shared (specify UnitsL-- )

75831-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stamped

Number _(yes or no)

A Disc Pacific 2-SN2 For valve tag 1KC008 REPLACED

B Disc Pacific 16-S30-71W For valve tag 1KC008 REPLACEM]

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 249: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Inspect Valve 1KC-008_

8. Test Conducted: Hydrostatic [-' Pneumatic LI Nominal Operating Pressure -] Other [- Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed TECHSPEC Date /2 ,2006 Owner -or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 10- ZO- W3 to 12_- (6- &b and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

•___ _'a__ Commissions NC 978 Inspector's Signature

Date _2- G- ,20 _

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 250: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/15/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Zi E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order i 982' Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System KC COMPONENT COOLING SYSTEM Class C 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 ITdentification of Comnonents Renaired or Renlacement Components

Section E Exhibit A

Sheet 1 of 1

"12 [] 3 - Shared (specify Units- )

75876-08

Column 1 Column 2 Column 3 Column: Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer, N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Bolting Rod-SA 193, Nut-SA194 for Component REPLACEM Cooling Water Hx "lA"

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 251: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section Xl Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Test/Clean Tubes_

8. Test Conducted: Hydrostatic E] Pneumatic Nominal Operating Pressure L-7 Other E-- Exempt [ Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed ,6& ,/ Zx

/

Expiration Date N/A

TECH SPEC Date ,20 aoOnen or Owner's Designee, Title

CERTIFICATE OF 'INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period Ii)- 2-4- 0 to ) -+4 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

- " M A Commissions NC 978

Inspector's Signature

Date _ I -A _,20_o 0

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit A

Page 252: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(((

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/27/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Z 1 LAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982'

Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C KD DIESEL GENERATOR COOLING WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE t• id-ntification of Conm onents Renaired or Renlacement Compnonents

Section E Exhibit A

Sheet 1 of 1

"]2 E 3 E-] Shared (specify UnitsE] )

75879-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

1 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

Number (yes or no)

A Bolting Threaded Rod- SA193 for DIG Eng. REPLACEM] Jacket Water Cooler "1A" REPAIRED

B REPAIRED

C REPAIRED

D REPAIRED

F REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 253: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Clean/Inspect D/G Eng. Jacket Wtr. Cooler "lA"_

8. Test Conducted: Hydrostatic D Pneumatic n Nominal Operating Pressure D Pressure psig Test Temp. deg.F.

Other [-- Exempt E

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed TECH SPEC Date /14 7 ,20oo Owner or Owner's Designee, Title

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period tO'2-a-W to I I- (,. - and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

___ Commissions NC 978

Inspector's Signature

Date ?2-- 1;_ ,20_CY-C)

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 254: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/05/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Mi L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982' Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System NC REACTOR COOLANT SYSTEM Class A 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE t Tc1ntif'icntinn n-ff(. mnnnnt• P e~nnired nr Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

]2 [3

76018-05

E Shared (specify Units[:] )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Valve Dresser BS-02869 For valve tag 1NC-002 1991 REPLACED

B Valve Dresser BS-02866 For valve tag 1NC-002 1979 REPLACEMI

C Bolting Threaded Rod-SA193, Hex Nuts-SA194 REPLACEM for valve 1NC-002

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 255: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replace Valve INC-002_

8. Test Conducted: Hydrostatic E] Pneumatic ] Nominal Operating Pressure [ Pressure 2236.1 psig Test Temp. 652.1 deg.F.

Other El Exempt El

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed/

Expiration Date N/A

TECH SPEC Date /Z ,20 o oOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period J15-co to )2-6-6- and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

. J O M "Y\J4 Commissions NC 978

Inspector's Signature

Date _2-- 6 ,20 Ox0

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit A

Page 256: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/13/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Zl L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982' Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System CA AUXILIARY FEEDWATER SYSTEM Class C 5. (a) Applicable Construction Code 1I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE •' ITl~ntifc'ntinn nf Crn•mnonEnt• R ennired or R enlacemrent Comnonents

Section E Exhibit A

Sheet 1 of 1

12 E] 3 [-] Shared (specify Units-] )

78670-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 1 4 6 8

Nameof Name of Manufacturer: N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Bolting Duke Power C-1CA 121 Nuts- SA194 for valve 1CA-173 REPLACEM] Co.

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 257: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Perform Check Valve Inspection

8. Test Conducted: Hydrostatic - Pneumatic [-] Nominal Operating Pressure [l Pressure psig Test Temp. deg.F.

Other[] Exempt Z

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Sirrned IAk4/

Expiration Date N/A

TECH SPEC Date /-/// ,20 Oc)Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period lb-17- 6b to / /3 -60) and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

spector's Signature

Date - _1J_,20_0

Page 2 of 2 Revision 6

LLTJ

Section E Exibit AASME Section XI Manual Form NIS-2 (Back)

Page 258: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( ( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/07/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit I1 [Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 9822 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A Expiration Date N/A

4 Identification of System SM MAIN STEAM SYSTEM Class B 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com onents Renaired or Replacement Components

S

Section E Exhibit A

Sheet 1 of 1

]2 D 3 D Shared (specify Units-] )

79225-01

Column 1 Column 2 Column 3 Co ColuCumn 5 Column Column 7 Column

4 6 8

Name of iName of Manufacturer N B,, Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number __(yes or no)

A Bolting Studs- SA193, Nuts- SA194 for Steam REPLACEM] Generator "1 A". Handholes Cover

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

k

Page 259: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R Handholes/lnstument Cover_

8. Test Conducted: Hydrostatic El Pneumatic 1-" Nominai Operating Pressure I-Pressure psig Test Temp. deg.F.

Other -Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed . c)A42,• •

/

Expiration Date N/A

TECH SPEC Date h_ ,200 f -1

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 1b-" 2G - ot to //- 0 C/0- and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978Inspector's Signature

Date •ý- 6 ,20_C70 -

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 260: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/07/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 L: Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Comp 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # N/A. Expiration Date N/A

4 Identification of System SM MAIN STEAM SYSTEM Class B 5. (a) Applicable Construction Code 11m 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE iq Te-l~ntificntinn nf~omn~nnent.• Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

"]2 -- 3 -- Shared (specify UnitsD-- )

79228-01

L

Column I Column 2 Column 3 Column Column 5 Column Column 7 Column

4 _ _ _ _ _ _ _ _ 6 8

- Name of Name of Manufacturer N B Other Identification (Size).' Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Numb r ________ _________________________________(yes or no)

A Bolting Studs- SA193, Nuts- SA194 for Steam REPLACEM (

Generator "ID". Handholes Cover B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

((

Page 261: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R Handholes/Instumentation Cover T-

8. Test Conducted: Hydrostatic [-] Pneumatic -] Nominal Operating Pressure El Pressure psig Test Temp. deg.F.

Other --] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of uthorization No. N/A

Signed i Zi/I

Expiration Date N/A

TECH SPEC Date / 2 ,20!Owner or Owner's-Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 11,Q9 .-W to 6,0 'Ot7 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property d_ age or a loss of any kind arising from or connected with this

inspect.

SJ I Commissions NC 978

Int ector's Signature

Date J 12 ,2O0 a-

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 262: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/10/01

Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982' Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C LD DIESEL GENERATOR LUBE OIL SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE A Identification of Cornonents Renaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

-2 - 3 [-] Shared (specify UnitsL-- )

75912-01/02

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Valve Crosby 62654-0-3 For valve tag #1LD-32 REPLACED

B Valve Crosby 62654-0-9 For valve tag #1LD-32 REPLACEM]

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page l of2 Revision 6

Page 263: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work

8. Test Conducted: Hydrostatic E] Pneumatic -1 Nominal Operating Pressure Pressure NA psig Test Temp. 160 deg.F.

Other El Exempt []

9. Remarks -No pressure gauge. Pressure is from level in sump pump.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

Expiration Date N/A

TECH SPEC Date //0 ,20 0// Owfier or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period if 2?_- o4 to I - 10 -0 J and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

_ __ommissions NC 978 Inspector's Signature

Date _J- 1 _, 2 0_0 ) _

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 ( Back)

Page 264: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/10/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Piant CATAWBA NUCLEAR STATION 2a Unit NZi L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982' Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System CF MAIN FEEDWATER SYSTEM Class B 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 -- 3 [- Shared (specify Units[] )

75926-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Rod End Valve Lisega 77620/11 For Steam Generator B Snubber REPLACED

B Rod End Valve Lisega 314808 For Steam Generator B Snubber REPLACEM]

C Blind End Valve Lisega 77620/11 For Steam Generator B Snubber REPLACED

D Blind End Valve Lisega 314808 For Steam Generator B Snubber REPLACEMI

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

( (

Page 265: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Repair SG Snubbers_

8. Test Conducted: Hydrostatic EL Pneumatic -] Nominal Operating Pressure [-] Other [-I Exempt ED

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of uthorization No. N/A

Signed I

/

Expiration Date N/A

TECH SPEC Date 41/d ,20 0/ 01

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period I -2--,Z to I - 10 -0 1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

__J__________ _ Commissions NC 978

Inspector's Signature

Date _)-tL ,20_- 1 i

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 266: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/06/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit i1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982' Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System NC REACTOR COOLANT SYSTEM Class A 5. (a) Applicable Construction Code 1I 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE SI~ ntif~c~ticrn nfC'¢m n~n•.nt• R enmrec nr Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

]2 E] 3 - Shared (specify UnitsD )

76019-05/03

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Valve Dresser BS-2870 Valve tag 1NC-03 1991 REPLACED

B Valve Dresser BS-2867 Valve tag 1NC-03 1979 REPLACEM

C Bolting Rod-SA 194, Hex Nuts-SA193 for valve REPLACEM 1NC-03

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

( /

Page 267: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R Valve 1NC-003_

8. Test Conducted: Hydrostatic L- Pneumatic [1 Nominal Operating Pressure Z

Pressure 2236.1 psig Test Temp. 652 deg.F.Other [-1 Exempt LI

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/_A Expiration Date N/A

Certificate of Authorization No. N/A

Signed TECH SPEC Date LZ/5- ,200 Owner or Owner's Designee, Title

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period I v- 19 -0 6 to I -9 9 - 1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978Inspector's Signature

Date _- - __ ,200 1

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 268: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/13/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 IE Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

( Section E Exhibit A

Sheet 1 of 1

12 - 3 F Shared (specify Units- )

78249-01/06

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Disc Dresser AAH41 For valve tag #1 SV 14 REPLACED

B Disc Dresser ADB88 For valve tag #1 SV 14 REPLACEM

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of2 Revision 6

Page 269: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I I in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Install refurbished Valve 1SV014_

8. Test Conducted: Hydrostatic U-- Pneumatic - Nominal Operating Pressure Z Pressure 987 psig Test Temp. 546.8 deg.F.

Other r] Exempt []

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Expiration Date N/AType Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed 4SL J

/ Owner or Owner's Designee, TitleTECH SPEC Date /Z!/_ ,20 o 0

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period / 0 -2-)" -O0 to /. -1 -6 1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ __M _4__ ____• Commissions NC 978 Inspector's Signature

Date _J-0 _,20-0 ]

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

Page 270: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/14/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit i1 E' Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE 5. (a) Applicable Construction Code I11 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE SITd~ntific.tinn nf~fc~no nent.• Renaired or Renlacement Cornnonentsq

/

Section E Exhibit A

Sheet 1 of 1

"]2 ' 3 [] Shared (specify Units] )

78250-01

Column 1 Column 2 Column 3, Column Column 5 - Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number__(yes or no)

A Valve Disc Dresser AD885 For valve tag 1 SV020 REPLACED

B Valve Disc Dresser AAH44 For valve tag 1 SV020 REPLACEM]

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 271: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

information in items I through 6 on this reports included oh each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Refurbish Valve 1SV-020_

8. Test Conducted: Hydrostatic n- Pneumatic L-i Nominal Operating Pressure 1111 Pressure psig Test Temp. deg.F.

Other Ei- Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

/

Expiration Date N/A

TECH SPEC Date O,20 e 0Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period Ib-2_-v. to 1-/44- 00 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property,.damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

Inspector's Signature

Date i-/4- ,20_L7-' -

Page 2 of 2 Revision 6

Forth NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Sine

Page 272: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/14/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [ 1 IL Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE 5. (a) Applicable Construction Code ll 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Identification" of•Cmnonent• Renaired or Renlacement Comnonents

(

Section E Exhibit A

Sheet 1 of 1

"12 Fl 3 L" Shared (specify Units- )

78252-01

.Colutim 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped (yes or no)

A Valve Disc Dresser AAH34 For valve tag #1SV0023 REPLACED

B Valve Disc Dresser ADB87 For Valve tag #I1SV0023 REPLACEMD

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 273: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Refurbish valve I SV-0023_ r, "

8. Test Conducted: Hydrostatic E- Pneumatic I- Nominal Operating Pressure 1 Other -' Exempt Z Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed j~sy

I./fv

Expiration Date N/A

TECH SPEC Date 20 gj,20 -0ON;ner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report' during the period 1-2- -w to //- 14,.) 0 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or propryqd qmage or a loss of any kind arising from or connected with this

inspection.

U tl YY/LX Commis ions NC 978

Inspector's Signature

Date (- •A_ ,20__U

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 274: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/13/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit N 1 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982, Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE 5. (a) Applicable Construction Code 11m 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

(Section E Exhibit A

Sheet 1 of 1

]2 - 3 D] Shared (specify UnitsD-- )

78271-01/06

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Disc Dresser AAH29 For valve tag #1SV008 REPLACED

B Disc Dresser ADB86 For valve tag #1SV008 REPLACEM]

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 275: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Instal arefurbished Valve 1SV-008_

8. Test Conducted: Hydrostatic s-- Pneumatic R Nominal Operating Pressures Other - Exempt L Pressure 984 psig Test Temp. 546 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed Tt• TECH SPEC Date .J/, ,20 o6 1 Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 1.1 -2-00oo to _.JO-o 1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

k" V"4dw Commissions NC 978 Inspector's Signature

Date _I-ID __ ,20_13 " _

Page 2 of 2 Revision 6

Section E Exibit AForm NIS-2 (Back)ASME Section XI Manual

Page 276: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

/l (

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/13/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 [Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982" Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class B SV MAIN STEAM VENT TO ATMOSPHERE 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE A Identification of Comronents Renaired or Renlacement Components

Section E Exhibit A

Sheet 1 of 1

]2 F] 3 [-] Shared (specify Units[:] )

78272-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Number Replacement Stamped Aumber D(yes or no)

A Disc Dresser AAH50 For valve tag # 1 SV 10 REPLACED

B Disc Dresser ADC13 For valve tag # 1SV 10 REPLACEM

C

REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of2 Revision 6

Page 277: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Install Refurbished Valve 1SVIO_

8. Test Conducted: Hydrostatic -- Pneumatic L'-] Nominal Operating Pressure [S Pressure 984 psig Test Temp. 546 deg.F.

Other E- Exempt El

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Expiration Date N/AType Code Symbol Stamp N/A

Certificate of Authorization No. N/A

SOwner or Owner's Designee, TitleTECH SPEC Date /Z//1 ,20 o

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 10 -2I) -o4 to i - 1o - 6 ; and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

V_,.Li_ " Commissions NC 978

Inspector's Signature

Date _"1, - __ ,20_-C

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 278: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

S~( ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/07/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Ml E1 Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982' Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # Expiration Date N/A

4 Identification of System SM MAIN STEAM SYSTEM Class B 5. (a) Applicable Construction Code 1m1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

"12 [] 3 [:] Shared (specify Units-- )

79226-01

Column 1 Column 2 Column 3, Column Column 5 , Column Column 7 Column 4 6 8

Nameof Name of Manufacturer N B, Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped _______________ Num er ________ _________________________________ ______yes__ oes onno

A Bolting Studs-SA193 for Steam Generator "IB" REPLACEM

Handhole/Instr. Port Cover

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 279: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual Form NIS-2 (Back) Section E Exibit A

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R Handhole/Instrumentation Port Cover_

8. Test Conducted: Hydrostatic [] Pneumatic -] Nominal Operating Pressure l Pressure psig Test Temp. deg.F.

Other -- Exempt Z

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed /J&Q TECH SPEC SOwne r Owner's Designee, Title

Expiration Date N/A

Date /•L ?,20 "o

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period W 0-.Lo0 to 1(- 6-0 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

*'Inspector' s Signiature

Commissions NC 978

Date_\k- ! ,20__)_

Page 2 of 2 Revision 6

Page 280: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/27/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit i1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class A KD DIESEL GENERATOR COOLING WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com onents Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 3 E] Shared (specify Units- )

82567-02

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Seal Weld Duke Power C-1KD 99 Seal weld bonnet to body on valve 1KD- REPLACEM] Co. 001

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 281: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work I/R Seat Leak_

8. Test Conducted: Hydrostatic 11 Pneumatic 0 Nominal Operating Pressure - Other El] Exempt [ Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed l/z Owner or'11wner's Designee, Title

Expiration Date N/A

TECH SPEC Date /IIZ, ,20 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Comnany of Hartford Connecticut have inspected the components described in this Owners Report during the period 8 --utp to i 2 - G- "a and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

""JýýA YVfr \ Commissions NC 978 Inspector's Signature

Date _J?- (j ,20_Q5U

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 282: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/19/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Hl IE Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System CA AUXILIARY FEEDWATER SYSTEM Class B 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 [-- 3 ] Shared (specify Units--- )

90940-05

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Valve Kerotest HAP-4-7 35855 For valve tag #ICA190 1983 REPLACED

B Valve Kerotest DANI-17 31246 For valve tag # 1CA 190 1980 REPLACEM]

C Pipe Duke Power C-1CA 121 2"Pipe-SA335 90 Elbow-SA182 REPLACEM] Co.

D Pipe Welds Duke Power C-1CA 121 1CA106-2,3,30,31 REPLACEM] Co.

E REPAIRED

F REPAIRED

Page 1 of2 Revision 6

I

Page 283: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Cut out & Replace Valve_

8. Test Conducted: Hydrostatic El Pneumatic ] Nominal Operating Pressure Pressure 1074 psig Test Temp. 105 deg.F.

Other F-- Exempt El

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of uthorization No. N/A

Signed

/

Expiration Date N/A

TECH SPEC Date 17,-& 20 0 C

Ow'ner- or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period //-b 2O o to --- 0 J and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

a din ,9V Commissions NC 978 Inspector's Signature

Date _ I- L-,20_0) _

Page 2 of 2 Revision 6

I

Section E Exibit AASME Section XI Manual Form NIS-2 ( Back)

Page 284: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/29/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 01 EAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 982 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System KC COMPONENT COOLING SYSTEM Class B 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com onents Renaired or ReDlacement Components

Section E Exhibit A

Sheet 1 of 1

12 [- 3 F- Shared (specify Units- )

98182-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Hinge Pin Pipe For Valve 1KC-322 REPLACEMI Plug

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 285: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Inspect Check Valve 1 KC-322_

8. Test Conducted: Hydrostatic 'l- Pneumatic ]Nominal Operating Pressure D Pressure psig Test Temp. deg.F.

Other-] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed A

Expiration Date N/A

TECH SPEC Date l/ -J ,20 tr• OF

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 10 - 2lc.o• to J "- I -C I and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

V.V\,. 4Ici Commissions NC 978 Inspector's Signature

Date-) • 1 -,20-0 1 _

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 286: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

KASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/19/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit E 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983( Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Tdentification of Comnonents Rernaired or Rernlacement Comn~onents

(

Section E Exhibit A

Sheet 1 of 1

]2 [- 3 F Shared (specify Units[ )

03241-01/07

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Base Metal Duke Power C-1RN 117 RNOF0002-BMR1ON,11N,12N,13N, REPLACEMI Repair Co. 14N,15N,16N,17N

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of2 Revision 6

Page 287: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"--" information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Contingency Repair Plan_

8. Test Conducted: Hydrostatic ED Pneumatic - Nominal Operating Pressure L] Other '] Exempt []

Pressure 75 psig Test Temp. 66 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed Aý/

Expiration Date N/A

TECH SPEC Date /Zý ,20 o0

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 11-6- o6 to 3 -01 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

Insp~ector'sMSignature

Date _ -) ,20_0 (_

Page 2 of 2 Revision 6

Section E Exibit AForm NIS-2 (Back)ASME Section XI Manual

Page 288: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

Ki (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/04/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Il L Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE7 Expiration Date N/A

4 Identification of System Class C KD DIESEL GENERATOR COOLING WATER SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

]2 [:3

13343-01/04

p0583

-] Shared (specify Units[:] )

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Valve BIF N59032-5 383 Valve tag 1KD28 1979 REPLACED

B Valve Fisher 8263C-01C 384 Valve tag 1KD28 2000 REPLACEMI

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 289: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Valve 1KD28_

8. Test Conducted: Hydrostatic El Pneumatic [-i Nominal Operating Pressure M Other -] Exempt El Pressure 12 psig Test Temp. 150 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed Oe Owner or Owner's Designee, Titi

Expiration Date N/A

TECH SPEC Date -j•4' ,20 06

Date J- _ b _,20OI __

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period [I- ?-- OD to [- b -0 1 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

]Inpector's Signature

Section E Exibit AForm NIS-2 ( Back)ASME Section XI Manual

Page 290: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/03/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 EI Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C NV CNEMICAL VOLUME CONTROL SYSTEM 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com onents Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 F 3 F-- Shared (specify UnitsD-] )

14456-07

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Bolting Studs-SA193, Hex Nuts-SA194 for REPLACEM] Manway to Boric Acid Tank

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 291: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x II in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Re-install Upper Manway Cover

8. Test Conducted: Hydrostatic [- Pneumatic [-] Nominal Operating Pressure El- Other L- Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed 4& 4c - TECH SPEC Date /3 ,200L Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period 10-2,-)-M to I -, I- 0) and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

a ector's Signature

Commissions NC 978

Date _1 i , II_200 ) __

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 292: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Sec" XI Manual ( FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. owner DUKE POWER COMPANY la Date 11/27/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Zl EI Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Comnonents Reraired or Renlraeemnt r'nmnAnPte

Section E Exhibit 1

Sheet 1 of 1

12 - 3 --1 Shared (specify Units- )

16401-14

Column I Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Bolting (yes or no) A Boltin Studs- SA193, Hex Nuts- SA194 for REPLACEM]

valve IRN-003A B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 293: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/28/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Zi t Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code EII 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

( Section E Exhibit A

Sheet 1 of 1

-2 ] 3 [- Shared (specify Units- )

23117-02

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped N e (yes or no)

A Bolting Studs-SA193, Hex Nuts-SA194 for REPLACEM] valve 1RN4B

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page I of 2 Revision 6

Page 294: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

*NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Inspect Flange Bolting_

8. Test Conducted: Hydrostatic [I] Pneumatic F- Nominal Operating Pressure D- Other LI Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed DseT Owner or Owner's Designee, Title

Expiration Date N/A

TECH SPEC Date // ," 20 r-

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period t) -2.-0 b to I - 9 -0; and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978inspector's Signature

Date _i-er 200 1 __

Page 2 of 2 Revision 6

Section E Exibit AASME Section XI Manual Form NIS-2 ( Back)

Page 295: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/28/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Zl IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE A TAintifit-itinn nf mrn nent5s Renaired or Renlacement Comnonents

(Section E Exhibit A

Sheet 1 of 1

]2 - 3 E Shared (specify Units- )

Z3240-01,09

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME

Component Manufacturer Serial Number Built Replaced. or Code Replacement Stamped

(yes or no)

A Pipe Duke Power C-1RN 117 18"Pipe-SA106, Flange-SA105, 90 REPLACEM Co. Elbow-SA234

B PipeWelds DukePower C-1RN 117 1RN149-12,11 1RN157-23 REPLACEM' Co.

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of2 Revision 6

Page 296: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Piping @ valve 1RN835_

8. Test Conducted: Hydrostatic F] Pneumatic - Nominal Operating Pressure E Other -] Exempt E] Pressure 62 psig Test Temp. 66 deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

Page 2 of 2 Revision 6

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed Titl TECHSPEC Date ,20_-) - r 0e--o ,Ce' Designee, Title "

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period [t• [,4,-00 to I - B -6o and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

Inspector's Signature

Date _I- _ , 2 0 0 )

Section E Exibit AASME Section XI Manual Form NIS-2 ( Back)

Page 297: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/19/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit ]1 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class B ND RESIDUAL HEAT REMOVAL SYSTEM 5. (a) Applicable Construction Code 1II 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Trt~ntific.ntion of (Th~mnonent.• Renniired or Rernlaeement Comnonents

(Section E Exhibit A

Sheet 1 of 1

"12 0] 3 - Shared (specify Units-] )

26347-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Snubber PSA 5795 1-R-ND-1 191 1979 REPLACED

B Snubber PSA 40264 1-R-ND-1191 1999 REPLACEM

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 298: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x I I in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Test/Replace I-R-ND- 1191_

8. Test Conducted: Hydrostatic 1- Pneumatic -7Nominal Operating Pressure Pressure psig Test Temp. deg.F.

Other-] Exempt Z

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed 4 TECH SPEC Owner or Owner's Designee, Title

Expiration Date N/A

Date 1/ ,20 oo

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period i -2-n-Do to ) - Ii -) -and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

- •9 4 Commissions NC 978

Inspector's Signature

Date 1 - ,k _ 20_0 1 __

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit A

Page 299: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(

ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/06/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 21 IE Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System CF MAIN FEEDWATER SYSTEM Class B 5. (a) Applicable Construction Code TIT 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

2 E:] 3 ] Shared (specify Units[:] )

26350-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number (yes or no)

A Snubber Pacific 4789 1-R-CF-1562 1979 REPLACED Scientific

B Snubber Pacific 41277 1-R-CF-1562 2000 REPLACEM] Scientific

C Snubber Pacific 4312 1-R-CF-1564 1978 REPLACED Scientific

D Snubber Pacific 12629 1-R-CF-1564 1982 REPLACEM] Scientific

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 300: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Test/Replace Snubbers_

8. Test Conducted: Hydrostatic ' Pneumatic El] Nominal Operating Pressure Other [i] Exempt Z

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed ,ýA

/ Owner or Owner's Designee, Title

Expiration Date N/A

TECH SPEC Date /•/"• ,20 oO

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period I0.21o0 to I - 10-11 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

Inspector's Signature

Date_ _I4(-_ 200~ ) __

Page 2 of 2 Revision 6

Section E Exibit AForm NIS-2 (Back)

Page 301: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 11/15/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [l F Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System SM MAIN STEAM SYSTEM Class B 5. (a) Applicable Construction Code III 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Identification of Con onents Renaired or Renlacement Comnonents

(Section E Exhibit A

Sheet 1 of 1

]2 [13 - Shared (specify Units[-- )

26351-01

Column 1 Column 2 Column 3. Column Column 5 Column Column 7 Column _4 6 8

Name of- Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number (yes or no)

A Snubber Pacific 6331 1-R-SM-1542 1979 REPLACED Scientific

B Snubber Pacific 12631 1-R-SM-1542 1982 REPLACEM] Scientific

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 302: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Test/Replace Snubber_

8. Test Conducted: Hydrostatic [-1 Pneumatic L] Nominal Operating Pressure LI Pressure psig Test Temp. deg.F.

Other Li Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Expiration Date N/A

Certificate of Authorization No. N/A

Signed TECH SPEC Date / " ,20 6 0 7 Owner or Owner's Designee, Title

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period [)-2k-L Vt to H5 00 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

YYX /Commissions NC 978

Inspector's Signature

Date _ý- IS 20_U G0

Section E Exibit AForm NIS-2 ( Back)ASME Section XI Manual

Page 303: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

I'

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/07/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 EI Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class B NV CNEMICAL VOLUME CONTROL SYSTEM 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Cop onents Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

]2 F-1 3 F-1 Shared (specify Units-] )

26623-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column

4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped

A__________________ Snubber P 8512(yes or no) B Snubber PSA 8512 1-A-NV-3188 1979 REPLACED

B Snubber PSA 9645 1-A-NV-3188 1980 REPLACEM

C REPAIRED

D REPAIRED

F REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 304: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R Snubbers

8. Test Conducted: Hydrostatic F1 Pneumatic 0ii Nominal Operating Pressure E-Pressure psig Test Temp. deg.F.

9. Remarks

Other [-i Exempt Z

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Sipmed 'A C4-7

Expiration Date N/A

TECH SPEC Date _ ,20 0oOwneror Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period D -?-'o -00 _ to t - -o and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

( Y'A.-' J-Commissions NC 978

Inspector's Signature

Date V - V0 _,20 0 ) _

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 305: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/12/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit [1 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code mI 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

12 '-D 3 [-] Shared (specify UnitsL-- )

27349-04/07

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Pipe Welds Duke Power C-1RN 117 Welds 1RN519-5 1RN519-BMR1 REPLACEM Co.

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

f

Page 306: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"J information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R RN Piping_

8. Test Conducted: Hydrostatic D Pneumatic l- Nominal Operating Pressure [7] Pressure 80 psig Test Temp. 56.2 deg.F.

Other F Exempt LI

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed At i TECH SPEC Owner or"11wner's Designee, Title

Expiration Date N/A

Date 12/7Z. ,20 o 0 I

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period /- (6,0-0 to I - ' -6 / and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

____ _ a_ Commissions NC 978

Inspector's Signature

Date _ ) -_ ,200 1__

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 307: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

ASME Section XI Manual FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/12/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Il 1 i Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp NL/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System SA MAIN STEAM SUPPLY TO AUX EQUP Class A 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Com onents Repaired or Replacement Components

( Section E Exhibit A

Sheet 1 of 1

"]2 E 3 F-1 Shared (specify UnitsD-- )

Z8694-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped

__ (es or no) A Weld Duke Power C-1SA 114 Weld #1-R-SA-1530-4 for hanger l-R- REPLACEM]

Co. SA-1530 B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 308: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Adjust Snubber Cold Set_

8. Test Conducted: Hydrostatic - Pneumatic l-- Nominal Operating Pressure [-

Pressure psig Test Temp. deg.F.

Other -Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed .Xzz,-

/

Expiration Date N/A

TECH SPEC Date _/L2, ,20 oO

Owfier r? Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period /1 --O ) to ) - I I -0 and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

Inspector's Signature

Date _I-- I 20- C I__

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 309: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 01/09/01 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 I" Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # CE Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 11I 1974 Edition, S'75 Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE T denti fi cation of C~omnonents Renaired or Renlacement Comnonents

Section E Exhibit A

Sheet 1 of 1

"]2 F] 3 [] Shared (specify UnitsLI )

28848-01/12

70610

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Valve BNL A981103-9-7 Valve tag #lRNF61 1999

B Pipe Duke Power C-1RN 117 2" Pipe-SA376, 2 '/2" Pipe- SA376, 90 REPLACEM] Co. Ell-SA1 82

C Pipe Welds Duke Power C-1RN 117 0RN29-2,3,4,5,6,7,8,17,18,19,20 REPLACEM. Co.

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 310: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work I/R Thru Wall Leak _

8. Test Conducted: Hydrostatic ElI Pneumatic LII Nominal Operating Pressure [2 Other [II Exempt F1

Pressure psig Test Temp. deg.F.

9. Remarks SNSWP is at normal level. There is no pressure or temperature indication associated with piping.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed 74* L2ft

/

Expiration Date N/A

TECH SPEC Date 9 ,20 O-Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period i /- .4 - ) to I - 9 .-5 ( and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

i•r -4i JY Commissions NC 978

Inspector's Signature

Date _i-9 _,20_1 _-

Page 2 of 2 Revision 6

M

Form NI S-2 (Back) Section E Exibit AASME Section XI Manual

Page 311: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/04/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit M 1 E Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code 11m 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE & Tdentificeition of Comnonent• Renaired or Renlacement Comn~onents

Section E Exhibit A

Sheet 1 of 1

12 D-- 3 E] Shared (specify Units- )

28848-07

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Bolting Hex Nuts-SA194, Studs-SA193 for REPLACEMI hanger 1-A-RN-3462

B Clamps For hanger 1-A-RN-3462 REPLACEM

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 312: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work R/R I-A-RN-3462_

8. Test Conducted: Hydrostatic El Pneumatic L] Nominal Operating Pressure El Pressure psig Test Temp. deg.F.

Other - Exempt E

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Shiped 12& K

Expiration Date N/A

TECH SPEC Date Z14L¢ ,20 ocOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period J1' S- o to 1 2 •-Lc and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_Cu A M U( Commissions NC 978 ln~pector's Signature

Date _ " _ 20_(

Page 2 of 2 Revision 6

/

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 313: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

/ (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/18/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit ]1 IAddress 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983 Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code m11 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Components Repaired or Replacement Components

Section E Exhibit A

Sheet 1 of 1

2 [1 3 [-1 Shared (specify Units[] )

29304-01

Column I Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Replacement Stamped Number _(yes or no)

A Base Metal Duke Power C-1RN 117 0RN29-BMR1 -, , "RED Repair Co. .44111-7_1_4,__

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 314: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2) information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Perform Base Metal Repair

8. Test Conducted: Hydrostatic 1-1 Pneumatic LI Nominal Operating Pressure E-- Other 0 Exempt [

Pressure psig Test Temp. deg.F.

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed /•A /4/

Expiration Date N/A

TECH SPEC Date /Z_/ ,20 _)

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period J)- 3 -oL to 1-3 • ? and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

""_ _ _ _ _ _ _ C Commissions NC 978 Inspector's Signature

Date _1 -S _,20 01 _

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 315: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

( (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/04/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit 1 I-Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System Class C RN NUCLEAR SERVICE WATER SYSTEM 5. (a) Applicable Construction Code I1 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6 Tdentifwaiontc of Comnonent,• Renaired or Renlacement Comnonents

(Section E Exhibit A

Sheet 1 of 1

12 3 E] Shared (specify Units-] )

30779-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number_ (yes or no)

A Bolting Hex ttats-SA193 for valve 1RN-45 REPLACEMI

B REPAIRED

C REPAIRED

D REPAIRED

D REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 316: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

"information in items 1 through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work Replace Broken Gasket Retainer_

8. Test Conducted: Hydrostatic D Pneumatic l'- Nominal Operating Pressure Pressure psig Test Temp. deg.F.

Other[--]Exempt Z

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed /t:& TECH SPEC Owner or Owner's Designee, Title

Expiration Date N/A

Date /-,,20 0 )

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Company of Hartford Connecticut have

inspected the components described in this Owners Report during the period I I- -0 1 to J - 0 -' and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's

Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

inspection.

Commissions NC 978

Inspector's Signature

Date_ I - i_,20_0 I _

Page 2 of 2 Revision 6

Form NIS-2 ( Back) Section E Exibit AASME Section XI Manual

Page 317: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(t (ASME Section XI Manual

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner DUKE POWER COMPANY la Date 12/04/00 Address 526 S. CHURCH STREET. CHARLOTTE N.C. 28201-1006

2. Plant CATAWBA NUCLEAR STATION 2a Unit Il 1 " Address 4800 CONCORD RD. YORK, S.C. 29745

3. Work Performed By Duke Power Company 3a Work Order # 983: Address 526 S. Church St. Charlotte, N.C. 28201-1006 Type Code Symbol Stamp NL/A Authorization No. N/A 3b NSM or MN # NA Expiration Date N/A

4 Identification of System SM MAIN STEAM SYSTEM Class B 5. (a) Applicable Construction Code 111 1974 Edition, S'75 Addenda, NONE Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Addenda NONE 6. Identification of Con onents Renaired or Renlacement Comnonents

S

Section E Exhibit A

Sheet 1 of 1

"12 F-- 3 D Shared (specify Units[:] )

34088-01

Column 1 Column 2 Column 3 Column Column 5 Column Column 7 Column 4 6 8

Name of Name of Manufacturer N B Other Identification (Size) Year Repaired. ASME Component Manufacturer Serial Number Built Replaced. or Code

Number Replacement Stamped Number _(yes or no)

A Bolting Threaded Rod-SA193, Hex Nuts- SA194 REPLACEM] for 1SMFE5770

B REPAIRED

C REPAIRED

D REPAIRED

E REPAIRED

F REPAIRED

Page 1 of 2 Revision 6

Page 318: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2in. x 11 in. (2)

information in items I through 6 on this reports included on each sheet, and (3) each sheet is numbered and the number of sheets is

recorded at the top of this form.

7. Description of Work I/R Orifice Flange Leak_

8. Test Conducted: Hydrostatic D- Pneumatic El Nominal Operating Pressure El] Pressure psig Test Temp. deg.F.

Other [I] Exempt 0

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A

Signed

/

Expiration Date N/A

TECH SPEC Date YL ,20 oOOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the

State or Province of NORTH CAROLINA and employed by HSB I AND I Comnpany of Hartford Connecticut have

inspected the components described in this Owners Report during the period I-Ž(-1_ c0 to / - I t- I and state that to the best

of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the

examinations and corrective measure described in this Owners Report. Furthermore, neither the Inspector nor his employer shall

be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_Commissions NC 978

Inspetor's Signature

Date ' _,2001 ___

Page 2 of 2 Revision 6

Form NIS-2 (Back) Section E Exibit AASME Section XI Manual

Page 319: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

11.0 Pressure Testing

There are three refueling outages scheduled for the second period of the second inspection interval for Duke Power's Catawba Nuclear Station Unit 1. This section describes Pressure Tests performed during the second period through the second refueling outage (also referred to as EOC-1 2).

Total Total (%)

Examination Test Requirement Examinations Examinations Examinations Category Required For Credited For Complete For

This Period This Period This Period

B-E System Hydrostatic 0 0 0% Test (IWB-5222)

B-P System Leakage Test 3 2 66.67% (IWB-5221)

B-P System Hydrostatic 0 0 0% Test (IWB-5222)

C-H System 21 19 90.48% Inservice/Functional

Test (IWC-5221)

C-H System Hydrostatic 0 0 0% Test (IWC-5222) _ I I

A detailed description of each Examination Category listed above is located in subsection 11.1 of this report. Results of each Examination Category are located in subsection 11.2 of this report.

Refueling Outage Report EOC12 Catawba Unit 1 Section 11

Page 1 of 4 Revision 0 December 6, 2000

Page 320: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

11.1 Required Examinations This Outage:

A listing of each pressure test and associated VT-2 Visual Examination conducted from EOC-1 1 through EOC-1 2 is included in this section.

The information shown below is a field description for the listing format included in this section of the report:

Zone No.

Flow Drawing

Required Test

System Name

Required Inspection

Required Procedure

ASME Item Number(s)

Comments

=The unique number assigned to track certain extremity valves that make up a pressure test.

= Detail drawing of pressure test boundary.

= Information that shows the required tests for the examination zone - (L) Leakage Test, (I) Inservice Test, (F) Functional Test, or (H) Hydrostatic Test.

= Name of pressure retaining component system

= Type of visual examination required.

= Required inspection procedure.

= ASME Section XI Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), and IWD-2500-1 (Class 3)

= Additional information if applicable

"Refueling Outage Report EOC12 Catawba Unit 1 Section 11

Page 2 of 4 Revision 0 December 6, 2000

Page 321: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

This( rt Was Generated On: eJ06/2000

Boundary flrn•winr

Required Test I III/:IH

Duke Power Company - Catawba Unit 1 Pressure Testing Zone Number Listing

Outage 12

Required Required SytmName Insnection Procedure

C

Int = 2

Period = 2

ASME Item Mm 1mk%ývI

Dra in r ... .... ..... ... ....... __vr v__Procedure

CN-1 553-1.0 x Reactor Coolant (NC) VT-2 QAL-15 B15.10 B15.30 B15.50 B15.60 BI15.70

N/A

CN-1553-1.1 X Reactor Coolant (NC) VT-2 QAL-15 B15.20 N/A

B15.50 B15.70

CN-1 554-1.0 X Reactor Coolant (NC) VT-2 QAL-15 B1i5.50 N/A

B15.70

CN-1 554-1.5 X Reactor Coolant (NC) VT-2 QAL-1 5 B135.50 N/A

B15.70

CN-1 561-1.0 X Reactor Coolant (NC) VT-2 QAL-1 5 B1 5.50 N/A

B15.70

CN-1561-1.1 X Reactor Coolant (NC) VT-2 QAL-15 B15.50 N/A

B15.70

CN-1 562-1.0 X Reactor Coolant (NC) VT-2 QAL-1 5 Bi 5.50 N/A

B15.70

CN-1 562-1.1 X Reactor Coolant (NC) VT-2 QAL-1 5 B1i5.50 N/A

B15.70

CN-1562-1.2 X Reactor Coolant (NC) VT-2 QAL-15 B15.50 N/A

B15.70

CN-1 562-1.3 X Reactor Coolant (NC) VT-2 QAL-1 5 B135.50 N/A

B15.70

7nnA NIumber

1 NC-001 L-Af, +

ZoneV Nu•ImberI•VII

•HIBi•'^ m mnl•{.Ijb

Page 322: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

This • rt Was Generated On: 1 ,•06/2000

Boundary Required TestIlrnwinn L IIIFIH

Duke Power Company - Catawba Unit 1 Pressure Testing Zone Number Listing

Outage 12

Required Required ASME Item~vtmN~mm In�nAetion Prnr�edure Numb�r(��

(

Int = 2

Period = 2

(•nmmi~nt_•

1 BB-001 L-B CN-1 565-2.6 X Steam Generator Blowdown VT-2 QAL-1 5 C7.30 N/A C7.70

CN-1 572-1.4 X Steam Generator Blowdown VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1580-1.0 X Steam Generator Blowdown VT-2 QAL-15 C7.30 N/A

C7.70

CN-1 584-1.0 X Steam Generator Blowdown VT-2 QAL-1 5 C7.10 N/A C7.30

1 CA-001 L-B CN-1584-1.0 X Auxiliary Feedwater (CA) VT-2 QAL-1 5 C7.30 N/A C7.70

CN-1591-1.1 X Auxiliary Feedwater (CA) VT-2 QAL-15 C7.10 N/A

C7.30 C7.70

CN-1 592-1.1 X Auxiliary Feedwater (CA) VT-2 QAL-15 C7.30 N/A

C7.70

CN-1593-1.0 X Auxiliary Feedwater (CA) VT-2 QAL-15 C7.30 N/A

C7.70

CN-1593-1.1 X Auxiliary Feedwater (CA) VT-2 QAL-15 C7.30 N/A

C7.70

CN-1 593-1.7 X Auxiliary Feedwater (CA) VT-2 QAL-1 5 C7.30 N/A

C7.70

1 FW-001 L-B CN-1554-1.2 X Refueling Water (FW) VT-2 QAL-15 C7.30 C7.70

N/A

CN-1554-1.7 X Refueling Water (FW) VT-2 QAL-15 C7.30 N/A C7.70

7.nn Numhmr

Refueling Water (FW) VT-2 QAL-1 5 C7.30 N/ACN-1 561 -1.0 X

Page 323: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

This ( t Was Generated On: ',.106/2000

Boundary lroAIlnn

Required Test I II1 .IW

Duke Power Company - Catawba Unit 1 Pressure Testing Zone Number Listing

Outage 12

Required Required System Name Insoection Procedure

Int = 2

Period = 2

ASME Item IKl, t.,• \

C7.70

CN-1 562-1.2 X Refueling Water (FW) VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1563-1.0 X Refueling Water (FW) VT-2 QAL-15 C7.30 N/A

C7.70

CN-1 570-1.0 X Refueling Water (FW) VT-2 QAL-15 C7.30 N/A

C7.70

CN-1 571-1.0 x Refueling Water (FW) VT-2 QAL-15 C7.30 C7.70

N/A

1 FW-002L-B CN-1571-1.0 X Refueling Water (FW) VT-2 QAL-1 5 07.30 N/A I RefC7.70

1ND-O01L-B CN-1 561-1.0 x x Residual Heat Removal (ND) VT-2 QAL-15 C7.10 C7.30 C7.50 C7.70

N/A

CN-1 561 -1.1 X X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A C7.70

CN-1 562-1.2 X X Residual Heat Removal (ND) VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1 562-1.3 X X Residual Heat Removal (ND) VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1 563-1.0 X X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A C7.70

CN-1571-1.0 X X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A

C7.70

7hns• M.iimhr

1 FW-001 L-B" =I pS f% inL

C7.30 N/A

i7i•/ll lPJilll~ Il nI| I 11 | .............

CN-1572-1.0 x x Residual Heat Removal (ND) VT-2 QAL-1 5

Page 324: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

This ( t Was Generated On: 1 ,,/06/2000

Boundary flra IAny,

Required Test I 1111 1W

Duke Power Company - Catawba Unit 1 Pressure Testing Zone Number Listing

Outage 12

Required Required 0 + Kar 1am *n en,*L.' fl.aA.

(

1t = 2 Period = 2

ASME Item-- **-,un• m*n--*~ • ulnnn -n u ' ' " ilinu IlJ!.P•IdLIUII rlU~'JItI:Uq• I'4UII*U•|EI•J V~UIIIE IIIU|]b

1NOD-001L-B C7.70

1ND-002L-B CN-1561-1.0 X X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A

C7.70

CN-1561-1.1 X X Residual Heat Removal (ND) VT-2 QAL-15 C7.10 N/A C7.30 C7.50 C7.70

CN-1562-1.2 X X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A

C7.70

CN-1562-1.3 X X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A

C7.70

CN-1563-1.0 X X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A

C7.70

CN-1571-1.0 X X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A C7.70

CN-1572-1.0 X X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A

C7.70

1ND-003L-B CN-1561-1.0 X X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A

C7.70

1ND-004L-B CN-1561-1.1 X X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A

C7.70

1ND-007L-B CN-1562-1.3 X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A

C7.70

1ND-008L-B CN-1562-1.3 X Residual Heat Removal (ND) VT-2 QAL-15 C7.30 N/A

C7.70

7e~na Nn. ummkr

1NI-002L-B CN-1 562-1.1 x Safety Injection (NI) VT-2 QAL-1 5 C7.1 0 N/A

Page 325: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

This t Was Generated On: S,,06/2000

Boundary Required Test Required Required ASME Item

(Duke Power Company - Catawba Unit 1

Pressure Testing Zone Number Listing

Outage 12

Zone Number Drawing L /I /F / H System Name InsDection Procedure Number(s) Comments

1NI-002L-B C7.30 C7.70

CN-1 572-1.1 X Safety Injection (NI) VT-2 QAL-1 5 C7.30 N/A

C7.70

1NI-004L-B CN-1562-1.2 X Safety Injection (NI) VT-2 QAL-15 C7.30 N/A

C7.50 C7.70

1N 1-006L-B CN-1562-1.2 X Safety Injection (NI) VT-2 QAL-15 C7.30 N/A C7.50 C7.70

1NS-001 L-B CN-1563-1.0 X Containment Spray (NS) VT-2 QAL-15 07.10 N/A

C7.30 C7.50 C7.70

1 NS-002L-B CN-1 563-1.0 X Containment Spray (NS) VT-2 QAL-1 5 C7.10 N/A C7.30 C7.50 C7.70

1 NV-001 L-B CN-1 554-1.0 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.10 N/A

C7.30 C7.70

CN-1 554-1.5 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1554-1.8 X Chemical & Volume Control (NV) VT-2 QAL-15 C7.30 N/A

C7.70

1 NV-002L-B CN-1554-1.7 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.30 N/A

C7.50 C7.70

Int = 2

Period = 2

Page 326: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

This ( It Was Generated On: I , 06/2000 Duke Power Company - Catawba Unit 1

Pressure Testing Zone Number Listing

Outage 12

Boundary Required TestDrawina L IIIFIH

Required Required ASME Item

1 NV-003L-B CN-1 554-1.7 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.30 N/A C7.70

1 NV-006L-B CN-1 554-1.0 x Chemical & Volume Control (NV) VT-2 QAL-15 C7.30 C7.70

N/A

CN-1 554-1.1 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1 554-1.2 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1 554-1.4 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1 554-1.5 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1 554-1.6 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1 554-1.7 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1 556-1.0 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1 562-1.0 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.30 N/A

C7.70

CN-1 562-1.2 X Chemical & Volume Control (NV) VT-2 QAL-1 5 C7.30 N/A

C7.70

Zone Number

(

~vtmNnmA

Int = 2

Period = 2

P^M"%,•n m+n

Page 327: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

11.2 Examination Results For This Outage:

The results of each pressure test and associated VT-2 Visual Examination conducted from EOC-1 1 through EOC-12 is included in this section.

The information shown below is a field description for the listing format included in this section of the report:

Zone Number

Boundary Drawing

Outage

Test Status

Test Result

VT-2 Examiner

VT-2 Date

=The unique number assigned to track certain extremity valves that make up a test.

= Detail drawing of pressure test boundary.

= The number for the refueling outage cycle of this report.

= Complete or Partial

= Clear (No Evidence Of Leakage), Reportable (Evidence Of Leakage - Not Through Wall such as packing leak), Reportable (Evidence Of Through Wall Leakage).

= The name of the Level II Visual examiner.

= Date that VT-2 visual examination was performed.

Refueling Outage Report EOC12 Catawba Unit 1 Section 11

Page 3 of 4 Revision 0 December 6, 2000

Page 328: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

Current Interval = 2 Current Period = 2

Class = A

K.

Duke Power Company - Catawba Unit 1 Pressure Testing VT-2 Examination Results

Zone Number 1 NC-O01 L-A

Boundary Drawing CN-1553-1.0

CN-1 553-1.1

CN-1554-1.0

CN-1 554-1.5

CN-1 561-1.0

CN-1 561-1.1

CN-1 562-1.0

CN-1562-1.1

CN-1 562-1.2

CN-1 562-1.3

Outage 12

12

12

12

12

12

12

12

12

12

Test Status Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Test Result Recordable

Recordable

Recordable

Recordable

Recordable

Recordable

Recordable

Recordable

Recordable

Recordable

VT-2 Examiner J. Brown

J. Brown

J. Brown

J. Brown

J. Brown

J. Brown

J. Brown

J. Brown

J. Brown

J. Brown

VT-2 Date 11/19/2000

11/19/2000

11/19/2000

11/19/2000

11/19/2000

11/19/2000

11/19/2000

11/19/2000

11/19/2000

11/19/2000

This Report Was Generated On: 12/06/200

(

Page 329: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(Current Interval = 2 Current Period = 2

Class = B

Duke Power Company - Catawba Unit 1 Pressure Testing VT-2 Examination Results

Zone Number

1 BB-001 L-B

1 CA-001 L-B

1 FW-001 L-B

1 FW-002L-B

1 ND-001 L-B

Examiner

This Report Was Generated On: 12106/200

(

Boundary Drawing CN-1 565-2.6

CN-1 572-1.4

CN-1 580-1.0

CN-1 584-1.0

CN-1 584-1.0

CN-1 591 -1 .1

CN-1 592-1.1

CN-1 593-1.0

CN-1 593-1.1

CN-1 593-1.7

CN-1 554-1.2

CN-1 554-1.7

CN-1561-1.0

CN-1 562-1.2

CN-1 563-1.0

CN-1 570-1.0

CN-1571-1.0

CN-1571-1.0

CN-1 561-1.0

CN-1 561-1.1

CN-1 562-1.2

CN-1 562-1.3

CN-1 563-1.0

CN-1571-1.0

Outage 12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

Test Status Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

This

Report Was

Generated

On:

12/06/200

Test Result Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Recordable

Recordable

Recordable

Recordable

Recordable

Recordable

VT-2 T. Murray

T. Murray

T. Murray

T. Murray

C. Mathews

C. Mathews

C. Mathews

C. Mathews

C. Mathews

C. Mathews

J. Brown

J. Brown

J. Brown

J. Brown

J. Brown

J. Brown

J. Brown

J. Fars

J. Faris

J. Faris

J. Fars

J. Faris

J. Fars

J. Faris

VT-2 Date 11/19/2000

11/19/2000

11/19/2000

11/19/2000

11/19/2000

11/19/2000

11/19/2000

11/19/2000

11/19/2000

11/19/2000

06/14/2000

06/14/2000

06/14/2000

06/14/2000

06/14/2000

06/14/2000

06/14/2000

08/09/2000

06/16/2000

06/16/2000

06/16/2000

06/16/2000

06/16/2000

06/16/2000

Page 330: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(Current Interval = 2 Current Period = 2

Class = BDuke Power Company - Catawba Unit 1 Pressure Testing VT-2 Examination Results

Zone NumberBoundary Drawing Outage

CN-1 572-1.0

1 ND-002L-B

1 ND-003L-B

1ND-004L-B

CN-1 561-1.0

CN-1 561-1.1

CN-1 562-1.2

CN-1 562-1.3

CN-1 563-1.0

CN-1 571-1.0

CN-1572-1.0

CN-1 561-1.0

CN-1561-1.1

12

12

12

12

12

12

12

12

12

12

Test Status Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Test Result Recordable

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

Clear

VT-2 Examiner J. Faris

J. Brown G. FORTENBERRY

J. Brown

J. Brown

J. Brown

J. Brown

J. Brown

J. Brown

J. Brown

T. MURRAY J. FARIS G. ANDERSON

VT-2 Date 06/16/2000

06/02/2000

06/02/2000

06/02/2000

06/02/2000

06/02/2000

06/02/2000

06/02/2000

10/17/2000

10/15/2000

1ND-007L-B

1 ND-008L-B

1 NI-002L-B

1NI-004L-B

1NI-006L-B

1 NS-001 L-B

CN-1 562-1.3

CN-1 562-1.3

ON-i 562-i1.1

CN-1572-1 .1

ON-i 562-1.2

ON-i 562-i1.2

ON-i 563-1 .0

12

12

12

12

12

12

12

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Clear

Recordable

Clear

Clear

Clear

Clear

Clear

J. Brown

T. MURRAY J. FARIS G. ANDERSON

M. MOORE D. STOGDEN

C. Mathews

C. Mathews

J. Fars

J. Brown

T. Murray J. Faris C. Mathews

This Report Was Generated On: 12/06/200

C

10/17/2000

10/15/2000

11/19/2000

11/19/2000

07/06/2000

04/28/2000

05/11/2000

Page 331: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

(Current Interval = 2 Current Period = 2

Class = B

Duke Power Company - Catawba Unit 1 Pressure Testing VT-2 Examination Results

Zone Number1 NS-002L-B

1 NV-001 L-B

1 NV-002L-B

1 NV-003L-B

1 NV-006L-B

Boundary DrawingCN-1 563-1.0

Outage12

CN-1 554-1.0

CN-1 554-1.5

CN-1 554-1.8

CN-1 554-1.7

CN-1 554-1.7

CN-1554-1.0

CN-1 554-1.1

CN-1 554-1.2

CN-1 554-1.4

CN-1 554-1.5

CN-1 554-1.6

CN-1 554-1.7

CN-1 556-1.0

CN-1 562-1.0

CN-1 562-1.2

12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

Test StatusComplete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Complete

Test ResultClear

Recordable

Recordable

Recordable

Clear

Clear

Recordable

Recordable

Recordable

Recordable

Recordable

Recordable

Recordable

Recordable

Recordable

Recordable

VT-2 Examiner T. Murray H. MATHEWS

J. Persinger

J. Persinger

J. Persinger

J. Brown

T. Murray

T. Murray

T. Murray

T. Murray

T. Murray

T. Murray

T. Murray

T. Murray

T. Murray

T. Murray

T. Murray

VT-2 Date 05/04/2000

11/19/2000

11/19/2000

11/19/2000

08/01/2000

06/22/2000

06/22/2000

06/22/2000

06/22/2000

06/22/2000

06/22/2000

06/22/2000

06/22/2000

06/22/2000

06/22/2000

06/22/2000

This Report Was Generated On: 12/06/200

(

I

Page 332: 10.0 Class 1 2 Repairs and Replacements file at Catawba Nuclear … · A Pipe Duke Power C-IKC 129 2"Pipe-SA-106, 90 Ell-SA105, Tee- REPLACEM] Co. SAI05, Insert-SAt05 B Pipe welds

11.3 Reportable Indications:

None

Refueling Outage Report EOC12 Catawba Unit 1 Section 11

Page 4 of 4 Revision 0 December 6, 2000