10 - POLYGLASS

4
Retaining walls with rising damp 10 TECHNICAL PROPOSAL Retaining walls with Rising damp issUe: 010 date: 05.11 ReVisiOn: 1 by: pOlyglass POLYGLASS SPA Registered Office - Viale Jenner, 4 - 20159 MILANO Head Office - Via dell’Artigianato, 34 31047 Ponte di Piave (TV) - Italy Tel. +39 04227547 - Fax +39 0422854118 www.polyglass.com - [email protected] Detail A Detail A 1 perimetral foundation wall 2 bituminous primer 3 bituminous membrane (1st layer) 4 bituminous membrane (2nd layer) 5 pOlyFOnd Kit dRain drainage layer 6 non-woven fabric filtration layer 7 perforated drainage tube 8 Refill

Transcript of 10 - POLYGLASS

Page 1: 10 - POLYGLASS

Retaining walls with rising damp

10TECHNICAL PROPOSAL

Retaining walls with Rising damp

issUe: 010

date: 05.11

ReVisiOn: 1

by: pOlyglass

POLYGLASS SPARegistered Office - Viale Jenner, 4 - 20159 MILANO

Head Office - Via dell’Artigianato, 3431047 Ponte di Piave (TV) - Italy

Tel. +39 04227547 - Fax +39 0422854118www.polyglass.com - [email protected]

Detail A

Detail A

1 perimetral foundation wall

2 bituminous primer

3 bituminous membrane (1st layer)

4 bituminous membrane (2nd layer)

5 pOlyFOnd Kit dRain drainage layer

6 non-woven fabric filtration layer

7 perforated drainage tube

8 Refill

Page 2: 10 - POLYGLASS

TECHNICAL SPECIFICATIONS ITEMS1. Concrete walls cleaned from all cement grout and formwork

rods; the concrete must be clean, dry, and seasoned. A rounded edge in mortar of cement will be installed at the foot of the turn-ups to permit correct membrane positioning.

2. All surfaces on which the waterproofing layer is laid on-site must be previously given a coat of a bituminous primer (POLYPRIMER HP 45 PROFESSIONAL by POLYGLASS S.p.A.) with 20÷25 viscosity in FORD Cup no. 4 at 25 °C. Wait until the primer is completely dry (15-20 hours) before applying the waterproofing layer.

3. The first waterproofing layer will be composed of a plasto-styrene waterproofing for professional use made with a latest generation distilled bitumen-based compound REOXTHENE ULTRALIGHT TECHNOLOGY in 4 mm thickness with continuous thread non-woven polyester fabric with elevated basic weight reinforced and stabilised by longitudinal glass fibre (EASY LIFT by POLYGLASS S.p.A. - produced by UNI EN ISO 9001:2008 and UNI EN ISO14001:2004 certified Quality System; conformity marking with intended use as per EN 13969 Multiple layer membranes for foundations). This membrane with -10 °C cold flexibility is made with the quality standards ensured by patented innovative technology which surpasses previous weight/thickness parameters, completely without mineral filler (calcium carbonate CaCo3), and with an ISO 1183 bituminous compound density of ≤0.95 kg/dm3. The membrane can be applied with perfect adherence to the previously applied vertical layer with overlaps of 8÷10 cm on the sides and 12÷15 cm on the heads and bonded by light torching with propane gas.

4. The second waterproofing layer will be composed of a plasto-styrene waterproofing for professional use made with a latest generation distilled bitumen-based compound REOXTHENE ULTRALIGHT TECHNOLOGY in 4 mm thickness with continuous thread non-woven polyester fabric with elevated basic weight reinforced and stabilised by longitudinal glass fibre (EASY LIFT by POLYGLASS S.p.A. - produced by UNI EN ISO 9001:2008 and UNI EN ISO14001:2004 certified Quality System; conformity marking with intended use as per EN 13969 Multiple layer membranes for foundations). This membrane with -10 °C cold flexibility is made with the quality standards ensured by patented technology which surpasses previous weight/thickness parameters, completely without mineral filler (calcium carbonate CaCo3), and with an ISO 1183 bituminous compound density of ≤0.95 kg/dm3. The membrane can be applied with perfect adherence to the previous layer with

8-10 cm overlapping at the sides and 12-15 cm overlapping at the heads bonded by light torching with propane gas. The layer must be turned up and bonded by torching without interruption along the walls. All the membranes forming the second waterproofing layer must be laid in the same direction as the first with longitudinal and transversal overlapping equal to or greater than the width of the bonding beam.

5. POLYFOND KIT DRAIN by POLYGLASS S.p.A., a protective drainage system made a with a new mixture of HDPE in truncated cone embossing bonded to white needle-loomed non-woven polypropylene fabric with 110 g/m2 density ensures waterproofing seal protection and rainwater drainage. The protective system is fastened using a perforated HDPE finishing tube 200 cm long, 7 cm high. The protective system can be fastened by impact with washers and nails in 25 mm galvanized steel.

6. Positioning at the base of the foundation of a perforated drainage tube sheathed in non-woven fabric.

7. Refill using clean backfill free from construction debris laid on-site with care to avoid damaging the mechanical protection provided previously.

Retaining walls with rising dampTECHNICAL PROPOSAL10

1 Concrete wall

2 bituminous primer

3 bituminous membrane (1st layer)

4 bituminous membrane (2nd layer)

5 pOlyFOnd Kit dRain protective drainage system

Page 3: 10 - POLYGLASS

EASY LIFT: In compliance with EN 13969 TYPE T product standards (layers for foundations).

Retaining walls with rising damp TECHNICAL PROPOSAL

technical characteristics of the membraneTEST METHOD TECHNICAL

CHARACTERISTICSUNIT OFMEASURE

NOMINAL VALUES

EN 1848-1 LENGTH m 10 (-1%)EN 1848-1 WIDTH m 1 (-1%)EN 1848-1 STRAIGHTNESS mm/10 m ExceedsEN 1849-1 THICKNESS mm 3 (-0,2)EN 1849-1 MASS PER UNIT AREA kg/m2 NPDEN 1928-B WATERTIGHTNESS kPa ExceedsEN 1928-BEN 1296

WATERTIGHTNESS AGAINST ARTIFICIAL AGEING kPa Exceeds

EN 1928-BEN 1847 WATERTIGHTNESS AGAINST CHEMICAL kPa Exceeds

EN 13501-1 REACTION TO FIRE Euroclass FEN 12317 SHEAR RESISTANCE N/50 mm NPD

EN 12311-1

TENSILE PROPERTIES MAxIMUM LOAD AT BREAK LongitudinalTransversal ELONGATION AT BREAKLongitudinalTransversal

N/50 mmN/50 mm

%%

700 (-20%)500 (-20%)

60 (-15)60 (-15)

EN 12691-A RESISTANCE TO IMPACT mm ≥800EN 12730-A RESISTANCE TO STATIC LOADING kg ≥15

EN 12310-1RESISTANCE TO TEARINGLongitudinalTransversal

NN

180 (-30%)220 (-30%)

EN 1109 COLD FLExIBILITY °C ≤-10EN 1931 WATER VAPOUR PROPERTIES μ 20000EN 1850-1 VISIBLE DEFECTS - Absent

EASY

LIF

T

10

technical characteristics of the protectionTECHNICAL CHARACTERISTICS

NOMINAL VALUES

MATERIAL High density polyethylene (HDPE) membrane; with polypropylene geotextile for POLYFOND KIT DRAINDRAINAGE MATERIAL White polypropylene geotextile of 110 g/m2

COLOUR BlackCERTIFIED COMPRESSION RESISTANCE 320 kN/m2 (32 ton/m2)ROLLS SIzE (M) 1,0 x 20 - 1,5 x 20 - 2,0 x 20 - 2,5 x 20 - 3,0 x 20 POLYFOND KIT DRAIN 2,0 x 20 HEIGHT OF THE STUDS 7 mm for POLYFOND KIT and 8 mm for POLYFOND KIT DRAINNUMBER OF STUDS FOR M2 About 1860AIR VOLUME BETWEEN STUDS About 5 l/m2

DIMENSION TOLERANCE +/- 4%DRAINAGE CAPABILITY 4,6 l/s/m2

THERMAL STABILITY From -40 °C to +80 °C

CHEMICAL AND PHYSICAL PROPERTIES Resistant to chemical agents, roots, not polluting water, resistant to fungal and bacterial contamination; non degradable

COMBUSTION CLASS B2 in compliance to DIN 4102

POLY

FOND

KIT

DRA

IN

Page 4: 10 - POLYGLASS

Retaining walls with rising dampTECHNICAL PROPOSAL

POLYGLASS SPARegistered Office - Viale Jenner, 4 - 20159 MILANO - Head Office - Via dell’Artigianato, 34 - 31047 Ponte di Piave (TV) - Italy

Tel. +39 04227547 - Fax +39 0422854118 - www.polyglass.com - [email protected]

10

11/1

1 -

2000

Retaining walls with Rising damp

issUe: 010

date: 05.11

ReVisiOn: 1

by: pOlyglass

POLYGLASS SPARegistered Office - Viale Jenner, 4 - 20159 MILANO

Head Office - Via dell’Artigianato, 3431047 Ponte di Piave (TV) - Italy

Tel. +39 04227547 - Fax +39 0422854118www.polyglass.com - [email protected]

Detail A

Detail A

1 perimetral foundation wall

2 bituminous primer

3 bituminous membrane (1st layer)

4 bituminous membrane (2nd layer)

5 pOlyFOnd Kit dRain drainage layer

6 non-woven fabric filtration layer

7 perforated drainage tube

8 Refill