1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

44
XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Transcript of 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Page 1: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

1

XAS 375 JD6 Compressors

Scott Malm

Committed tosustainable productivity.

Page 2: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

2

Product Data - XAS 375 JD6

Page 3: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Settings/Shutdowns - XAS 375 JD6

Page 4: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

4

AIR SYSTEM INLET VALVE

Spring loaded in the open position

Control Air closes the inlet

Also serves as check valve

Page 5: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Unloading valve

Regulating valve Regulating valve

Load solenoid

Min Press valve

Unloading valve

Load solenoid

Min Press valve

No Load/ Starting Load

Page 6: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Regulating valve Regulating valveUnloading valveUnloading valve

Min Press valve Load solenoid Min Press valve Load solenoid

Unload Blow Down

Page 7: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

9

REGULATING SYSTEM REG VALVE

Spring loaded

Adjusting receiver pressureby changing spring tension

• to pressure gauge and loading valve

• to speed regulator• to unloading valve

Regulating pressure:

Receiver pressure

The air receiver pressure can be set to another value by adjusting the spring tension of the regulating valve. This is done by turning the handle on top the valve. Increasing the spring tension, by turning in, will increase the regulating pressure and consequently the pressure inside the vessel. Turning out will decrease the pressure.

In order to regulate the pressure inside the reciever tank of our compressor, the air intake and the engine speed have to be controlled. This is done pneumatically. For that reason, we need regulating pressure. The regulating valve reduces the pressure inside the tank, thus providing the regulating pressure. This regulating pressure is then supplied to the unloader valve and the speed regulator or RPS.

Page 8: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

10

Maintains a minimum pressure

of 58 PSI for oil flow

Also contains the final check

valve

AIR SYSTEM MIN PRESS VALVE

Page 9: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Control Panel

Page 10: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Load Solenoid Valve – 1089 9515 02

Page 11: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Maintenance – XAS 375 JD6

Page 12: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

14

XC 2002 Controllers

Page 13: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

15

XC2002 Controller - XAS 375 JD

Page 14: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

16

XC2002 Control Module

Display

Fuel Level

Engine Coolant Temperature

Engine Oil Pressure

Engine RPM

Battery Voltage

Service Timers

Engine Inlet Air Temperature

Fuel Consumption (L/H)

Engine Fuel Temperature

Regulating Pressure

Log List – Will Hold last 30 Historic Codes

Alarm List – Shows Active Alarms Only

Parameters – Choose Another Language, Reset Service Timers, Change Measuring Units, etc…

Page 15: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Control Module – 1604 9516 01

Page 16: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

XC2002 Controller

John Deere codes will display here

Page 17: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

XC2002 Controller

Page 18: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

XC2002 Controller

Page 19: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

XC2002 Controller – * Unit Type 2

Page 20: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

J1939 Canbus Communication

Page 21: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

J1939 Canbus Communication . Cont…

Page 22: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

John Deere Engine Fault Code List

Page 23: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

John Deere Engine Fault Code List

Page 24: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

John Deere Engine Fault Code List

Page 25: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

John Deere Engine Fault Code List

Page 26: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

John Deere Engine Fault Code List

Page 27: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

John Deere Engine Fault Code List

Page 28: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

John Deere Engine Fault Code List

Page 29: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

John Deere Engine Fault Code List

Page 30: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

John Deere Engine Fault Code List

Page 31: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Displaying of J1939 DM1 Alarms

Page 32: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

34

Electrical System

Page 33: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

35

Legend

Page 34: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Detailed Electrical Diagram

36

Page 35: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

37

John Deere – Tier III – RPS in place of Pneumatic Speed Regulator

Regulating Pressure Sensor

“Speed Sensor”

Page 36: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

38

*Preheat Relay K1 Controlled by JDEC

Starter RelayPreheat Relay

Page 37: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

K1 – Preheat Relay – JDEC Warning

Page 38: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Troubleshooting - Information

40

Page 39: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

41

Troubleshooting - Information

Page 40: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

42

Troubleshooting - Information

Page 41: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

43

Preventive Maintenance Filter Kits – XAS 375 JD6

Page 42: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Spare Parts Recommendation

Page 43: 1 XAS 375 JD6 Compressors Scott Malm Committed to sustainable productivity.

Committed tosustainable productivity.