1 Right-Sizing Automation for Medicinal Chemistry Support your entire department with One-Minute NMR...
-
Upload
ernest-dickerson -
Category
Documents
-
view
212 -
download
0
Transcript of 1 Right-Sizing Automation for Medicinal Chemistry Support your entire department with One-Minute NMR...
1
Right-Sizing Automation for Medicinal ChemistrySupport your entire department withOne-Minute NMRTM
• Fun• Easy• Robust• Fast• Efficient• Economical• Controllable• Flexible
Copyright © 2006 by Protasis Corporation, All Rights Reserved
2
Enhancing Your NMR InvestmentGet the most from your instruments
• Easy Open Access Web login for vials and plates reduces time spent in the lab.
• Automated System Suitability and Maintenance provides assurance of good spectra.
• Microgram Samples avoids return trips to the lab and enables scale-down upstream in your workflow.
• Plate and Vial Submission simplifies reformatting and sample preparation.
• Closed-Loop Instrument Control enhances NMR error reporting
• Integrated ACD/Labs and One-Moon Scientific back-end software eliminates manual processing steps.
3
Answers Needed From NMR
Copyright © 2006 by Protasis Corporation, All Rights Reserved
90%
9% 1%
Did I makethe stuff?What is thisstuff?Other
Source: Survey of 40+ Industry and Academia by Protasis Corporation
Bonus: yield (ERETIC)Percentage Of Samples
4
What is it?
Everyone wants a magic wand!
Leap/CTC PALLiquid Handler
CapNMR ProbeNMR Spectrometer
ACD/Automation Server
E-Mail OrWeb Site
You Just Log In Samples
One-Minute NMRManages The Details
ACD/Web Librarian
Did I make it?
Yield?
Copyright © 2006 by Protasis Corporation, All Rights Reserved
5
UseCapNMR
Log-in Samples…
6
Walk away…Let One-Minute NMR run your sample
7
Click…
Seconds Later…In your InBox
Hot-linked E-mail reportIntegrated ACD/Web Librarian
Copyright © 2006 by Protasis Corporation, All Rights Reserved
8
9
10
11
LEAP PAL
• Fast• Low Volume Pickup• Low Dead Volume• Syringe-Only
Technology• Flexible Sample
Storage • Dilute /
Reconstitute• Sample Return
Copyright © 2006 by Protasis Corporation, All Rights Reserved
12
Effortless Solvent Management
• Vacuum Degasser– Smooth
MicroFlows
• Helium Sparging / Blanketing– Protect
Expensive Deuterated Solvents
Copyright © 2006 by Protasis Corporation, All Rights Reserved
13
HTSL High-PressurePumping System
14
NMR Instrument AutomationYour spectrometer is controlled and Monitored by the One-Minute NMR system.
SEND: • Commands to start experiments• Create sample directories• Query file locations• Molecule files
RECEIVE:• Status messages• Error messages• File locations
You get e-mail:Finished NoticesPlate maps with integrated processing software.Error alerts from NMR, Liquid Handler, etc.
On your Web* site:Main Web PageACD/Labs WebLibrarian
*
15
Automated System Suitability• Certified and Sealed standard solutions in
your solvent• Run before every Nth sample or at startup• Checks Signal / Noise and Line Shape to
assure good results. Stops if out of spec.
16
ACD/Labs Structure Confirmation and DatabasingAdaptive Experiments Get Results, Save Time
1D Proton
>= 1D Proton Acceptance Level
HSQC
ConfirmedRejected
>= AVG(HSQC + 1H1D) Acceptance Level
YESNO
Copyright © 2006 by Protasis Corporation, All Rights Reserved
17
Automated System MaintenanceThis is flow
• Probe Clean Every Nth Sample– 1 or 2 cleaning solutions 1 or 2 solvent
flushes– Specially designed Acid + Base solution
• Automated Startup and Shutdown Procedures– 1 or 2 Injector and syringe cleans– Probe cleans– Solvent flushes
18
Microgram SamplesMake it easier
• 30 – 300 micrograms of typical small molecules works great
• If that is all you have, then get it returned.• Plenty of source sample, why bother going
back to the lab for 100µg?• Perfect match for analytical (.46cm) scale
HPLC peak, scaled-down your purifications• Or, take 20µL from semi-prep HPLC fraction
exchange to d-solvent
19
The Advantages of CapNMR (micro-scale)
Scaled-Down Purifications
Scrape off a spot into filter. Add DMSO-d6, spin.
Collect fractions at analytical scale HPLC
Exchange to minimal d-solvent
A
20
The Advantages of CapNMR (micro-scale)
A
Can you spare a few µg? No waiting at the NMR Lab! No return trip!
21
The advantages of going tubeless…
•No shimming between samples•No washing tubes
•Minimal sample transfer
•Efficient storage
•Disposable
•Economical
Incredible Time Savings
Copyright © 2006 by Protasis Corporation, All Rights Reserved
Plates Make It EasyWould you ever run these in tubes?
22
Current One-Minute NMR Installations
• 22 Systems Total• 17 Varian• 5 Bruker• 1 Custom Automated Structure
Confirmation Systems (VNMR)• 2 Turn-Key Automated Structure
Confirmation Systems (VNMR/VNMRJ)
• 3 Walkup Open Access Systems
Copyright © 2006 by Protasis Corporation, All Rights Reserved
23
Use CasesInterviewed Feb 9, 2006 & Feb 15, 2007
Scientist AMajor PharmaceuticalOpen-Access converted to a service.
Scientist CMajor PharmaceuticalOpen-Access Improvement
A
B
Copyright © 2006 by Protasis Corporation, All Rights Reserved
C
Scientist BMajor PharmaceuticalVAST Replacement
24
Use Case: Scientist A
A
Before One-Minute NMR
• 3 NMR Systems• 5mm Tubes• Open-Access• Chemists Prepare Samples• Chemists Interpret Spectra• Actual use: 600 samples / month.• Capacity: 1900 samples / month
“If utilization gets to 100% there is a hanging.”
Copyright © 2006 by Protasis Corporation, All Rights Reserved
25
Use Case: Scientist A2 One-Minute NMR Discovery Tower Systems + ACD/Labs AutomatedStructure Confirmation
• Actual Use: 4000 / month• Capacity: 8000+ / month • Structure Verification for Every Sample• 1D Verification, 60% Accurate• Water Suppression• ERETIC Quantitation
“Different dynamics now: Verification, used to be done by chemists. It is easy with familiar compounds, but hard when chemistry changes. The demand went way up from Parallel Medicinal Chemistry. It puts NMR back in the game for structure verification.”
A
Copyright © 2006 by Protasis Corporation, All Rights Reserved
26
Use Case: Scientist A
A
010002000300040005000600070008000
Before * After
Samples / Month
Actual UseCapacity
* 3 Instruments vs. 2
“OMNMR puts NMR back in the game for verification.”
Copyright © 2006 by Protasis Corporation, All Rights Reserved
27
Use Case: Scientist A
Before * After
Direct Labor and Utilization
Labor FTEsActual Use
“I just scan the barcode label and click Start.”
A
Copyright © 2006 by Protasis Corporation, All Rights Reserved
28
M4_1H_MF.esp
7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5Chemical Shift (ppm)
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
No
rma
lize
d In
ten
sity
2.160.132.681.611.42
O
O
OH
CH3
M4_1H_MF.esp
6.865 6.860 6.855 6.850 6.845 6.840 6.835 6.830 6.825 6.820 6.815 6.810Chemical Shift (ppm)
0
0.05
0.10
0.15
0.20
0.25
0.30
No
rma
lize
d In
ten
sity
Scientist A – Model Compound
A
29
Use Case: Scientist B
B
Before One-Minute NMR: Conventional Flow Injection
“It all depends on what kind of data, quant?, dilute?, viscous?, auto shimming?”
• Capacity: 10800 samples / month!• Actual Use: 1200 – 1500 samples / month.
Copyright © 2006 by Protasis Corporation, All Rights Reserved
30
Use Case: Scientist B
• Capacity: 5800* samples / month• Actual use: 1200 – 2500 samples / month• Solvent + Water Suppression• Much more robust than (conventional flow NMR).• 88 wells/plate, 6 minutes per well, 10 hours per plate, 2.5 plates / day.• Using 1/10th solvent, 1/5th sample mass • More sample goes to screening.• OMNMR Enables combinatorial arrays.• Used for structure verification and patent backup• Happy and looking for continued progress
B
“OMNMR is much more robust than my old system. I would not want to go back.With the old flow system or Tubes you just wouldn’t do it”
* Could run faster
1 entry-level One-Minute NMR System
31
Use Case: Scientist B
0
2000
4000
6000
8000
10000
12000
Before * After
Samples / Month
Actual UseCapacity
B
Copyright © 2006 by Protasis Corporation, All Rights Reserved
32
Use Case: Scientist B
0
2
4
6
8
10
Before After
Solvent, Sample, Robustness*
Solvent UseSample UseRobustness
B
* Relative values
Copyright © 2006 by Protasis Corporation, All Rights Reserved
33
Scientist B: Model Compound
test_save
9 8 7 6 5 4 3 2 1 0 -1Chemical Shift (ppm)
0
0.05
0.10
0.15
No
rma
lize
d In
ten
sity
DMSO-d6
2.0
1
2.6
02
.61
2.6
22
.63
3.1
3
3.5
3
6.5
96.6
1
6.9
26
.93
6.9
6
9.1
8O
OH
CH3
B
34
Use Case: Scientist C
C
Before One-Minute NMR: 5mm Tube Walkup
“Chemists are a conservative bunch.”
• 400 MHz Varian• Verification Support• Actual Use: All day, 10 minutes / chemist
Copyright © 2006 by Protasis Corporation, All Rights Reserved
35
C
“We will buy 2 more systems if we can run samples in 5 minutes”.
1. Walkup Plates and Vials 15 min cycle time, Chemists like the system.
2. Excellent data quality3. Proactive Contact: Administrators like the system
but wish it was faster4. After 1 day of effort, 5 minute cycle times achieved5. After 2 more days of effort, 1.5 minute cycle times
achieved6. Management approval for new systems, contingent
on more effective sample preparation.7. Filter vials, filter removal tool, and instructions sent,
testing underway.
36
One-Minute NMR EconomicsHow does it fit in?
• NMR provides valuable structure information. Why not have it for every compound?
• One-Minute NMR puts NMR (vs. MS) back in the game for more samples.
• Do you want to run plates, and keep open access too?
• Thinking about a new NMR to expand capacity? Think again!
Copyright © 2006 by Protasis Corporation, All Rights Reserved
37
Thanks
• One-Minute NMR Collaborators Everywhere
• Scientist A, B, C (You know who you are.)
AB
Copyright © 2006 by Protasis Corporation, All Rights Reserved
38
Help spread the word!
www.protasis.com508-481-4163
Now NMR is easier and faster
One-Minute NMR