RS SeriesUV & UV / WBIR
Alarm Relay
Analog
Safe Area use only
Fire Sentry still sells a lot of these!
4
UV only
RS-0010RS-0010(B)
9 volt battery12-24 VDCbuilt-in hornnon-latching relayNO or NC contacts
UV only
RS2-0010
FS2-0010(B)
12-24 VDC
latching relay
NO or NC contacts
UV/VIS/WBIR
RS2D-00098
FS2DCR-00098
12-24 VDC
latching relay
non-latching relay
form C contacts
RS Series
5
Model SS2 UV / WBIR / VIS Explosion Proof
- Indoor & Outdoor use Internal Self-Test FirePic™ Alarm & Fault Relays FireBus™ RS485 Use Unitized or with CM1-A Controller Versions for specialty applications
requiring high speed response, such as Airbag and Munitions manufacturing
6
24 VDC
(1) FAULT RELAY– NO/NC Normally Energized
(1) FIRE ALARM Relay – NO/NC Normally De-Energized
Model SS2 (Unitized Mode)
Note:Sensitivity Setting: 60 feetElectronics Self Test Only
RS-485 FireBus™ Protocol to PC
7
Model SS3 Safe Area use
UV & UV / WBIR / VIS
FirePic™
Alarm Relay
FireBus™ RS485
Use Unitized or with CM1-A Controller
8
Silane Gas Cabinets Clean Rooms Warehouses Computer Rooms
Model SS3PRODUCT APPLICATIONS
Note:NEMA 1 Enclosure (Use only in Non-Hazardous Areas)
9
Model SS4UV & UV / WBIR / VISExplosion Proof
- Indoor & Outdoor useOptical and Internal Self-TestFirePic™Alarm, Verified Fire & Fault RelaysFireBus RS485Use Unitized or with CM1-A ControllerOptimized version for Hydrogen,
Natural Gas, Methanol & Ethanol Fires
10
Petrochemical Plants
Refineries Petroleum Product
Pipelines Gas Processing
Plants Offshore Drilling and
Production Platforms Gas Compressor
Buildings Petroleum Prod.
Pumping Stations Product Storage
Terminals
Crude & Product Tank Farms
Gas Turbine Enclosures
Gas Collection Facilities
Marine Terminals Rail Loading &
Unloading Terminals Gasoline Loading
Terminals LNG & LPG Storage
and Distribution Silane Gas Cabinets Silane Gas Storage
Aircraft Hangars, Commercial and Military
Power Plants Paints & Solvents
Storage Aerosol Filling
Facilities Cogeneration Plants Warehouses Engine Test Cells Marine Engine
Rooms
Model SS2 & SS4PRODUCT APPLICATIONS
11
24 VDC
(1) FAULT RELAY– NO/NC Normally Energized
(1) FIRE ALARM Relay – NO/NC Normally De-Energized
(1) FIRE VERIFY RELAY – NO/NC Normally De-Energized
RS-485 FireBus™ Protocol to PC
Model SS4 (Unitized Mode)
Note:Factory Sensitivity Setting: 45 feet, (selectable 60, 30 and 15 feet)Through the Lens & Electronics Self Test
12
Up to 30 Devices in the Loop (4) PROGRAMMABLE ZONE
ALARM RELAYS- NO/NC Normally De-Energized
(1) MASTER ALARM RELAY - NO/NC
Normally De-Energized
(1) FAULT RELAY - NO/NC Normally Energized
FS2000 SYSTEM
SS2-A
SS4-A
SS4-A
SS2-A
SS3-A
FireBus™ ProtocolRS-485 4 Wire Loop
CM1-A Controller
120 VAC
RS-232 PC Communication
13
Model FS7 The World’s largest
selling Fire Detector for Semiconductor Wet Benches!
NIR / WBIR / VIS Two Stage Alarm FM Approved Leak-proof, Polypropylene Housing Unitized or Controller based versions Six FirePics™ FireBusII™ RS485
14
Clean Rooms Wet Bench Working Surfaces Clean Room Pump & Equipment Area Wet Bench Plenum Area IPA & Chemical Stations
Model FS7 SystemPRODUCT APPLICATIONS
15
Equipment Area behind Wet Bench
Robot Wafer Load and Unload Area
Plenum Area under Process Tanks
Surface Area detection, includingrobot deck area acrossProcess Tanks
Head Case
Typical Location of Detectors
16
24 VDC
To Next Junction Box
Junction Box
(1) FAULT Relay – NC Normally Energized
(4) Programmable Zone Alarms NC – Normally De-Energized
Zone 1 - ALARM or ALERTZone 2 - ALARM or ALERTZone 3 - ALARM or ALERTZone 3 - ALARM or ALERT
1 to 12 Detectors can be connected to the controller
FS7-130-SX
FS7-2173
RS-232 PC Communication
Model FS7 with FS7-130-SX Controller
17
(1) ALERT Relay – NO
(1) FIRE ALARM Relay – NO
(1) FAULT Relay – NC
(1) 24 VDC Releasing Circuit
(1) 24 VDC Annunciator (0.15A)
(1) 24 VDC Output (0.1 A)
120 VAC
Manual Call Station
Contact Device
FSWB-1
Junction Box
FS7-2173
RS-232 PC Communication
Model FS7 Detector with FSWB Controller
To Next Junction Box
1 to 9 Detectors can be connected to the controller
18
(1) FAULT Relay – NC Normally Energized
(1) ALERT Relay – NO Normally De-Energized
(1) FIRE ALARM Relay – NO Normally De-Energized
24 VDC
Model FS7-2173-2RP Unitized Fire Detector
RS-485 FireBus II™ Protocol to PC
19
Model FS10 For use with Electrostatic
Liquid and Powder PaintApplications
NIR / WBIR / VIS Complies with NFPA 33 Explosion Proof - Indoor use Unitized, Card Controller or
Wallmount Control Panel Systems FirePic™ with FireBusII RS-485
20
Electrostatic Liquid Paint Spray Line Electrostatic Powder Coating Booths Paint Drum Storage & Paint Mix Rooms Aerosol Filling Automotive Engine Testing Infrared Curing Ovens Diesel Generators (Indoors) Gas Compressor Stations (Indoors)
Model FS10PRODUCT APPLICATIONS
21
(1) ALERT Relay – NO/NC Normally De-Energized(0.5 sec Response)
(1) FIRE ALARM Relay – NO/NC Normally De-Energized(4 sec Response)
(1) FAULT Relay – NO/NC Normally Energized
(3) PROCESS SHUTDOWN Relays – NO/NCNormally Energized
Primary Application:Paint Booths
120 VAC
Note:Detector Sensitivity is 15 or 30 Feet
RS-232 PC Communication
Model FS10 Wallmount Controller
22
(1) MAJOR FAULT – NO/NC Normally Energized
(1) FIRE ALARM Relay – NO Normally De-Energized(4 sec Response)
(1) MINOR FAULT – NO Normally De-Energized
(1) ALERT / FEW Relay NC Normally Energized(0.5 sec Response)
Note:Detector Sensitivity: 15 or 30 Feet
General Finishing:
Liquid & Powder Coating
Model 2GF
RS-232 PC Communication
120 VAC
Model FS10 Card Controller
23
General Finishing:
Liquid & Powder Coating
(1) FAULT Relay – NC Normally Energized
Note:Detector Sensitivity: 15, 30, or 45 Feet, (no ALERT relay with 45 ft. sensitivity)
RS-485 FireBus II™ Protocol to PC
(1) ALERT Relay – NO Normally De-Energized(0.5 sec Response)
(1) FIRE ALARM Relay – NO Normally De-Energized(4 sec Response)
24 VDC
Model FS10-R Unitized Detector
(Relay Output Version)
24
General Finishing:
Liquid & Powder CoatingALARM: 20 Ma(4 sec Response)
ALERT: 12 mA(0.3 sec Response)
FAULT: 0 mA
NORMAL: 4 mA
Model FS10-A Unitized Detector
(Analog Output Version)
Note:Detector Sensitivity: 15, 30, or 45 Feet, (no ALERT relay with 45 ft. sensitivity)
24 VDC RS-485 FireBus II™ Protocol to PC