©CO2Meter,Inc. Rev.13April2016 1

1%or30%CO2+Temperature&%RH

DiffusionDataLoggers

ModelsCovered

CM‐0016 CM‐0209CM‐0017 CM‐0210CM‐0018 CM‐0212CM‐0‐18AA CM‐0213CM‐0019

SaveForFutureReference

YourModel:

SerialNumber:

PurchaseDate:

2

TableofContents

WELCOME..................................................................................................................3 

IMPORTANTSAFEGUARDS...................................................................................3 

PRODUCTOVERVIEW.............................................................................................4 

THEORYOFOPERATION................................................................................................................4 

PACKAGECONTENTS..............................................................................................4 

OPTIONALACCESSORIES...............................................................................................................4 

POWERINGTHEMETER........................................................................................5 

BATTERYLIFE.................................................................................................................................5 CHARGINGTHEMETER..................................................................................................................6 

SOFTWARE................................................................................................................7 

CAPABILITIES..................................................................................................................................7 MINIMUMSYSTEMREQUIREMENTS............................................................................................7 INSTALLATION................................................................................................................................7 

OPERATIONGUIDE..................................................................................................8 

CONNECTINGTHEMETER.............................................................................................................8 SETTINGTHEMETER.....................................................................................................................8 LOGGINGDATA...............................................................................................................................9 SETTINGTHELOGGINGINTERVAL...............................................................................................9 DISPLAYANDALARM(CM‐0016,CM‐0017ONLY).............................................................9 

CALIBRATION...........................................................................................................9 

METERSPECIFICATIONS....................................................................................11 

TROUBLESHOOTINGGUIDE..............................................................................12 

SUPPORT.................................................................................................................13 

WARRANTY............................................................................................................13 

LIABILITY................................................................................................................13 

RETURNS.................................................................................................................13 

3

WelcomeThankyouforpurchasingourmeter.CO2Meter,Inc.isaFloridabasedbusinessspecializinginthedesignandmanufacturingofgasdetectionandmonitoringdevices–mainlyCO2.Ourapproachisonebasedinthescienceofgasandhowbesttoaccuratelyandrepeatedlymeasurethatgasfortheenduserspurposes.Ourbusinesspartnersinagriculture,HVAC,science,safety,research,pharmaceuticals,beverage,andotherfieldsfindourdevicestobehighlyaccurateandcosteffective.

Weapproacheachcustomer’sapplicationasauniqueopportunitytounderstand,educate,andprovideproductsolutionsthatmeetthecustomers’needswhileexceedingtheirexpectationsforreliabilityandservice.Ourcontinuedproductinnovationincombinationwithour“customerfirst”focusallowsCO2Meter,Inc.tocontinuetoprovidesolutionsforthefuture.

BasedinOrmondBeach,FL,CO2Meter,Inc.iscommittedtothesuccessofourcustomers;thehealth,welfare,andprosperityofourtalentedemployees;andthecontinueddevelopmentofourlocalcommunity.

CO2Meter,Inc.appreciatesyourbusinessandlooksforwardtoworkingwithyouandyourteaminthefuture.

Pleasetakesometimetoreadthroughthismanualinordertobecomefamiliarwithyourmeter.Payspecialattentiontotheimportantsafeguardsbelow.

ImportantSafeguardsToreducetheriskoffire,electricalshockand/orinjury,basicsafetyprecautionsshouldalwaysbefollowedwhenusingelectricalappliances,includingthefollowing:

1. READALLINSTRUCTIONSBEFOREUSINGTHISMETER.2. INSTALLGasLab®SOFTWAREBEFORECONNECTINGMETERTOACOMPUTER.3. Chargerechargeablemetersforatleast5‐8hoursbeforeuse.4. Therechargeabledataloggerscontainalithiumpolymer(Li‐Ion)battery.Donotexposeto

extremeheatorcold.5. TheLi‐Ionbatteryisnotuser‐replaceable.Pleasedonotattempttoopenthemeterand

replacethebattery.6. DonotuserechargeableAAbatteries.7. FormodelsusingAAbatteries,donotstorethemeterwiththeAAAlkalinebatteries

installedtopreventthepotentialforbatteryleakage.8. Useonlythesupplied5/6VDCinternationalwallpowersupplyadapter.Precisely5/6V

mustbeappliedtothemeter.Othervoltagescancausepermanentdamage.9. Themeterisnotdesignedforoutdooruse.10. Donotallowthemetertobeexposedtowater.11. Donotoperatethemeterwiththeenclosureopened.12. Donotoperatethemeterifitismalfunctioning.13. Useofthisdeviceinenvironmentsabove95%humiditymaycauseirreparabledamageto

thecomponents.

SAVETHESEINSTRUCTIONS

4

ProductOverviewThisCO2Meter,Inc.dataloggerisdesignedtomeasurecarbondioxide(CO2),percentofrelativehumidity(%RH),andtemperaturethroughdiffusionsampling.Itstorescollecteddatatoitsinternalmemorytoberetrievedatalatertimeforanalysis.WhencombinedwithourGasLab®software,youcanalsoseereal‐timedataonyourcomputer’sscreen.

Scientificdevicessuchasthisdataloggerrequiretheusertohaveanintimateknowledgeofthemeter,itsoperation,therequiredsoftware,andthemeterspecificationspriortouse.CO2Meter,Inc.highlyrecommendsreadingthisuser’smanualbeforeoperatingthedevice,especiallytheImportantSafeguardssectionabove.

TheoryofOperationTheCO2sensorinsidethismeterusesNDIR(non‐dispersiveinfrared)technologytosense,asafunctionoftransmittedlight,theconcentrationofCO2intheair.Ithasbeenfactorycalibratedtooperatewithinthespecifiedrangeandprecision.

PackageContentsVerifythatyourpackagecontainsthefollowingitemsbeforeusingthemeter:

Allmeters:

• (1)Meter• (1)5/6VDCinternationalpowersupply• (1)6‐footUSBCable• (1)CalibrationCertificateTag• (1)User’sManual

CM‐0016orCM‐0017 CM‐0018,CM‐0018AA,

CM‐0019,CM‐0209,CM‐0210CM‐0212,CM‐0213

OptionalAccessoriesAHydrophobicVentFilterKitmaybepurchasedseparately.Thesefiltersareidealforhigh‐humidityenvironmentstoallowairflowwhilekeepinghumidityout.Long‐lasting,useanywherehumidityisveryhigh(>95%).OrderpartnumberCM‐0172.

5

PoweringtheMeterAlldataloggerscomewithaninternationalpoweradapterandarebattery‐powered.SomemetersarepoweredbyaninternalrechargeableLi‐Ionbatteryandothersbydrycellnon‐rechargeablealkalineAAbatteries(notincluded),dependingonthemodelofthemeter.Thetablebelowshowsdetailedinformationaboutthebatteryusedbyeachavailablemodel.

ModelNo. Configuration LCD BatteryType Capacity(mAh)CM‐0016 1%CO2+RH/T Yes 4DryAACell* 1,800‐2,600CM‐0017 30%CO2+RH/T Yes 4DryAACell* 1,800‐2,600CM‐0018AA 1%CO2+RH/T No 4DryAACell* 1,800‐2,600CM‐0018 1%CO2+RH/T No RechargeableLi‐Ion 2,200CM‐0019 30%CO2+RH/T No RechargeableLi‐Ion 2,200CM‐0209* 30%CO2+RH/T No RechargeableLi‐Ion 6,000CM‐0210* 1%CO2+RH/T No RechargeableLi‐Ion 6,000CM‐0212 1%CO2+RH/T No RechargeableLi‐Ion 3,600CM‐0213 30%CO2+RH/T No RechargeableLi‐Ion 3,600

*DiscontinuedModels

IMPORTANT:METERSUSINGDRYAACELLS:USENON‐RECHARGEABLEALKALINEBATTERIESONLY.DONOTSTORETHEMETERWITHTHEBATTERIESINSTALLEDTOPREVENTTHEPOTENTIALFOR

BATTERYLEAKAGE.

BatteryLifeThebatterylifefordataloggersdependsontheselectedlogginginterval.Thetablebelowshowstheestimatedbatterylifebasedonsometypicalloggingintervals.

LoggingInterval

Est.BatteryLife2,200mAhorAA

Est.BatteryLife3,600mAh

30sec. 24hrs. 40hrs.1min. 48hrs. 80hrs.5min. 240hrs. 400hrs.10min. 480hrs. 800hrs.30min. 1,440 hrs. 2,400hrs.1hour. 2,880 hrs. 4,800hrs.

Oncethememoryisfull,themeterwillcontinuetolognewdataovertheoriginaldatabeginningatthefirstdatapoint.Therefore,aftereachloggingsessionyoushoulduseGaslab®tosaveyourdata.

Becausethedataisstoredinnon‐volatilememory,datawillbeloggeduntilthebatteriesareexhausted.However,thelogsfilesmaynotappearinGaslab®.Youcanstillextractthemusingthe“recoverlogs”featureinGaslab®.

IMPORTANT:DOWNLOADTHELOGGEDDATAANDRECHARGEBATTERIESAFTEREVERYUSETOPREVENT

POSSIBLEDATALOSS.

IFTHEMEMORYISFULL,PREVIOUSLYLOGGEDDATAWILLBEOVERWRITTEN.

6

ChargingtheMeterMeterspoweredbyrechargeableLi‐IonbatteriescanbechargedusingthesupplieduniversalpoweradapteroraUSBportonapoweredcomputer.Li‐Ionbatterieswillbefullychargein5‐8hoursandwillloseabout8%oftheirchargingcapacitypereveryyearofuseat25°C.

Figure1:Dataloggermodelswithoutdisplay

Figure1:Dataloggermodelswithdisplay

ON/OFFswitch.Datalogging

startsatswitchON.

PowerONindicatorLED.

ON/OFFswitch.DataloggingstartsatswitchON.

Alarmmutepushbutton.

MiniUSBport.

Poweradapterconnector.

LCDdisplay.

MiniUSBport.Usedfordatatransferredandpoweradapter.

7

SoftwareOurmetersuseGasLab®software,afreetoolthatletsyouconfigureyourmeter,downloaddatalogsandmore.

Capabilities• ConfigureMeter• Manageanddownloadlogs• Adjustloggingintervals• Calibratethemeter• AutomaticdataloggingwhenmeterispoweredON• Collectdatainreal‐timeandviewonscreen

MinimumSystemRequirementsToutilizethesoftware,yourPCmustmeetthefollowingminimumrequirements:

1GHzprocessorwith1GBRAM,1GBfreediskspace(2GBfreediskspacefor64‐bitsystems).

WindowsXP*/7/8/8.1withMicrosoft.NETFramework4.0**orlater. OnIntel‐basedMaccomputers,GasLab®softwarecanrunusingaWindows7/8virtual

machinesoftwaresuchasVMwareFusion®orsimilar.

*Microsoft.NETisnotsupportedonMediaCenterorTableteditions.**Installerwilloptionallyinstall.NETFramework.

InstallationGotohttp://www.co2meter.com/pages/downloadstodownloadourfreeGasLab®softwareforWindows.

IMPORTANT:YOUMUSTINSTALLSOFTWAREBEFORECONNECTINGTHEMETERTOYOURCOMPUTER.

ToinstalltheGasLab®software,followthestepsandinstructionspromptedbyyourcomputer’soperatingsystem.Makesureyouhaveadministratorprivilegesinordertoinstallthisprogram.

Afterthesoftwareisinstalled,pluginthemeterwiththeincludedUSBcable.YouroperatingsystemwillautomaticallyinstalltheproperUSBdriversnecessaryforthemeterto“talk”toyourPC.

WestronglyrecommendallowingGasLab®toinstalldriversforthemeterautomatically.

ReadtheGasLab®manualhttp://co2meters.com/Documentation/Manuals/Manual‐GasLab.pdfcarefullytobecomemorefamiliarwithhowthesoftwareworkssothatyoucangetthemaximumbenefitfromyourmeter.

8

OperationGuideMakesureyoureadthroughtheseinstructionsthoroughlybeforeusingthemeter.Thisguidewillhelpyoubecomemorefamiliarwiththemeterinordertobeasproductiveaspossibleinashortperiodoftime.PleasereadtheImportantSafeguardsonpage3beforecontinuing.

IMPORTANT:Followtheseinstructionstoensurepropersetup:

1. DownloadandinstalltheGasLab®Softwaretoyourcomputer.2. Powerthemeterusingbatteriesortheincludedinternationalpoweradapter.

NOTE:connectingtheincludedUSBcabletoaportinacomputerwillnotsupplytheappropriatepower.

3. TurnONthemeter.4. IfthemeterhasaLCDdisplaywaituntilthedisplaychangescolorstovisuallyconfirmithas

resetsuccessfullyafterconnectingittoaUSBportonacomputer.

ConnectingtheMeterThefirsttimethemeterisconnectedtoyourcomputer,theoperatingsystemwillinstallthenecessaryUSBdriversasshowninFigure2.Thisprocesscouldtakeafewminutes.

Figure2:USBDriverInstallation.

SettingtheMeter1. EnsurethedataloggingswitchisintheONposition.2. ConnectthemetertothecomputerusingtheincludedUSBcable.3. LaunchtheGasLab®software.4. Connectthemeter/sensortoyourcomputer

NOTE:Themetermustbestartedatleast1minutepriortouseanddataloggingtoallowtheCO2sensorenoughtimetowarm‐upandcalibrate.Afterconnectingthemetertoacomputerandsettingit,theGasLab®softwarewillallowyoutoperformthefollowingmainfunctions: CollectReal‐time–databeingrecordedisdisplayedongraph. ManageandDownloadLogs–provideoptionstomanagedatalogssavedinthemeter. ConfigureSensor–provideoptionstosetupthesensorinsidethemeteranddatalogging

options,amongotherfeatures.NOTE:AseparatedatafilewillbecreatedeachtimethemeterispoweredON(startslogging).

9

LoggingDataOncetheGasLab®softwarehasbeeninstalledandthemeterisconnectedtothecomputer,youcangatherdatainavarietyofways.Dependingonthetypeofmeter,datacanbecollectedinrealtime,datalogscanbedownloadedfromthemeter’smemory(ifequipped),andsavedtothecomputer,anddatacanbereviewedonthemeter’sLCDdisplay(ifequipped).Foreachloggingsession

1. TurnthemeterON.2. Themetermustbestartedatleast1minutepriortodeploymentanddataloggingtoallow

theCO2sensortimetowarm‐upandcalibrate.3. Setthelogginginterval(min30sec)asdesiredandcommencelogging.4. Whendataloggingiscompleted,turnthemeterOFF.

SettingtheLoggingIntervalTochangethedefaultsettings,connectthemetertoacomputerusingtheincludedUSBcable.Selectthedesiredmeter,andchangethesettings.NOTE:RefertotheGasLab®User’sManualforcompleteinstructions.DisplayandAlarm(CM‐0016,CM‐0017only)Thisdataloggingmeterincludesabuilt‐inaudible(80dB)alarmandanLCD(LiquidCrystalDisplay)displaythatprovidesvisualindicationofthecurrentCO2levelbychangingcolortogreen,yelloworred,dependingonCO2levelrangesselected.ThedisplaywillchangecolorsdependingontheactualCO2levelreadingsbysettingthe“Green”,“Yellow”,and“Red”ranges.ThealarmissetperLEEDIAQlevelsbydefaultbutcanbeprogrammedtootherstandardssuchasOSHAlevelsusingtheGasLab®software.Thenewalarmlevelwillbemaintainedinthemeter’smemory.Duringoperation,whenthemeteristurnedon,andwhenthehighconcentrationCO2levelprogrammedisreached,an80dBalarmwillsound.Thealarmcanbemutedfor30secondsbypressingthebuttononthefrontofthemeter.ThisfeaturecanbechangedinGasLab®.

CalibrationTheCO2sensor,inIAQapplicationsonly,usesanalgorithmcalledAutomaticBackgroundCalibration(ABC)toensuremaximumaccuracybycontinuouslyadjustingthezero‐point.TheABCalgorithmallowstheCO2sensortodynamicallyshiftitsCO2readingbyaconstant.ItworksviastoringthelowestCO2sampletakenovertheABCPeriodandassumingthatthislowvalueisequaltoaknownvalue(thetargetvalue).ItthenadjuststheoutputoftheCO2readingbythedeltabetweenthesevalues.Thisalgorithmdoesnotaffectthelinearizationoftheoutputsignal.Forexample,bydefaultABCisenabledwithanABCPeriodof180hours,atargetvalueof400ppm,andamaximumdeltaof30ppm.Thisoperatesundertheprinciplethatambient,outdoorairisat400ppm.

10

ThesensorwillkeeptrackofthelowestCO2readingrecordedoveraperiodof180hoursandthenadjustthezeropoint,upto30ppmatatime,towardsthatvalue.Toensuremaximumaccuracyitisrecommendedtoinstallthedeviceinanenvironmentthatwillroutinelyseethislowvalue.Inaddition,thismetercanbeexposedtofreshairforafewminutesbetweenusestoverifycalibrationbymakingsurethereadingsarecloseto400ppm,orcanbemanuallycalibratedusingtheGasLab®software.

NOTE:RefertotheGasLab®User’sManualforcompleteinstructions.

11

MeterSpecificationsMeasuringPrinciple:CO2

Non‐dispersiveinfrared(NDIR)sensor

MeasuringRange:1%CO2 models 0‐10,000ppm30%CO2models 0‐300,000ppm(0‐30%vol.)

Repeatability:1%CO2 models ±20ppm,±1%measuredvalue30%CO2models ±0.1%,±2%ofmeasuredvalue

Accuracy:1%CO2 models ±30ppm,±3%measuredvalue30%CO2models ±0.2%,±3%ofmeasuredvalue

CO2SensorRatings:LifeExpectancy >15yearsWarm‐upTime <1min(instantmeasurements)

TemperatureSensor:Range ‐40to120°CRepeatability ±0.1°C

Accuracy ±0.5°CRelativeHumiditySensor:

Range 0‐100%Repeatability ±0.1%

Accuracy ±3%Dimensions:LxWxD

(mm)inches(146.1)5.75x(91.4)3.60x(32.7)1.30

DataLogging:DataPoints 60,000ininternalmemoryProgrammableIntervalData Date,Time,CO2,%RH,Temp.

Power: Input Voltage 5VDC (useonlysuppliedadapter)PowerConsumption 500mA(whilecharging)

ChargingTime 5‐8hrs.(approximately)BatteryType/Capacity 4xAA(CM‐0016,‐0017,‐0018AA)

Li‐Ion/2,200mA(CM‐0018,‐0019)Li‐Ion/6,000mA(CM‐0209,‐0210)Li‐Ion/3,600mA(CM‐0212,‐0213)

Li‐IonBatteryLifetime 2‐3 years dependingoncycles

12

TroubleshootingGuide

Symptom/Issue

PossibleCause

Resolution

Meterisnotrecognizedbycomputer

Nopower. Replace/recharge thebatteriesorconnectmetertotheincludedpowersupplyandpowermeterON.

Meterisnotrecognizedbycomputer

UnabletofindcorrectCOMportforUSB.

ReadthisAppnoteonreassigningCOMportsforUSB:http://www.co2meters.com/Documentation/AppNotes/AN134‐Change‐COM‐Ports.pdf

Alllogtimestampsstartintheyear2000

Thereal‐timeclockwasnotsynced.

Connectthemetertothecomputerwithdataloggingoff.ThetimewillsynchronizeinGasLab®.

Nologsarepresentonthemeterafterdatalogging

Meterwasdisconnectedwhilelogswerebeingdownloaded.

Connectthemeter tothecomputeranddownloadlogsagain.

Metervoltagedroppedbelow5V.

Use“RecoverLogs”functioninGaslab.

ThedisplayisBlueorshowsSensorMissing

Themeter’sEEPROMiscorrupted,orbattery/powersupplyissues.

Emailtechnicalsupportforfurtherassistance.

CO2Readingsareinaccurate

ABCisadjustingthezeropoint.

TurnoffABCinsoftwareorensuretheunitisexposedto400ppmairwhiledatalogging.

Batteriesarelow.

Replace/rechargebatteries.

Themeterwasdisturbedmechanically.Metermayneedcalibration.

PerformacalibrationorsendtoCO2Meterforprofessionalcalibrationandrecertification.

13

SupportThequickestwaytoobtaintechnicalsupportisviaemail.Pleasesendallsupportinquirestosupport@co2meter.com.

Pleaseincludeaclear,concisedefinitionoftheproblemandanyrelevanttroubleshootinginformationorstepstakensofar,sowecanduplicatetheproblemandquicklyrespondtoyourinquiry.

WarrantyThismetercomeswitha1YEAR(warrantyperiod)limitedmanufacturer’swarranty,startingfromthedatethemeterwasshippedtothebuyer.

Duringthisperiodoftime,CO2Meter.comwarrantsourproductstobefreefromdefectsinmaterialsandworkmanshipwhenusedfortheirintendedpurposeandagreestofixorreplace(atourdiscretion)anypartorproductthatfailsundernormaluse.Totakeadvantageofthiswarranty,theproductmustbereturnedtoCO2Meter.comatyourexpense.If,afterexamination,wedeterminetheproductisdefective,wewillrepairorreplaceitatnoadditionalcosttoyou.

Thiswarrantydoesnotcoveranyproductsthathavebeensubjectedtomisuse,neglect,accident,modificationsorrepairsbyyouorbyathirdparty.NoemployeeorresellerofCO2Meter.com’sproductsmayalterthiswarrantyverballyorinwriting.

Useofthisdeviceinenvironmentsabove95%humiditymaycauseirreparabledamagetothecomponentsandisnotwarranted.

LiabilityAllliabilityunderthisagreementshallbelimitedtotheactualcostoftheproductpaidtoCO2Meter.com.InnoeventshallCO2Meter.combeliableforanyincidentalorconsequentialdamages,lostprofits,lossoftime,lostsalesorlossordamagetodata,injurytopersonorpersonalpropertyoranyotherindirectdamagesastheresultofuseofourproducts.

ReturnsIftheproductfailsundernormaluseduringthewarrantyperiod,aRMA(ReturnMaterialAuthorization)numbermustbeobtainedfromCO2Meter.com.AftertheitemisreceivedCO2Meter.comwillrepairorreplacetheitematourdiscretion.

ToobtainaRMAnumber,callusatoremailusat(386)256‐4910support@co2meter.com.WhenrequestingaRMApleaseprovidereasonforreturnandoriginalordernumber.

Iftheproductfailsundernormaluseinthefirst10daysofownership,atourdiscretionwewillemailyouapostage‐paidUPSlabeltoreturntheproductatourexpense.

14

Ifwedeterminethattheproductfailedbecauseofimproperuse(waterdamage,dropping,tampering,electricaldamageetc.),orifitisbeyondthewarrantydate,wewillinformyouofthecosttofixorreplacetheproduct.

ContactUs

Weareheretohelp!

Forinformationortechnicalsupport,pleasecontactus.

[email protected]

(386)256‐4910(TechnicalSupport) (386)872‐7665(Sales)

www.CO2Meter.com

Address:CO2Meter,Inc.131BusinessCenterDriveOrmondBeach,FL32174USA