1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT...

11
1 Detector position August 2005, supplement May’06 sub- detector mean Z delta Z Z_start Z_end TT 2485 430 2270 2700 First pillar =1 st shelf at sides 7487 200 7387 7587 clearance 51 inner tracker T1 7733 190 7638 7828 outer tracker T1 7948 220 7838 8058 clearance 11 2 nd shelf in middle 8185 231 total 8069 only shelf 8100 8300 8300 clearance 10 inner tracker T2 +MFD 8400 220 200 envelope 8290 at level of RASNIK 8310 8510 outer tracker T2 8630 220 8520 8740 clearance 40 Second pillar = 3 rd shelf 8880 200 8780 8980 clearance 25 inner tracker T3 9100 190 9005 9195 outer tracker T3 9315 220 9205 9425 Extra pillar 8880 200 8780 8980 RICH2 9450

Transcript of 1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT...

Page 1: 1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT 248543022702700 First pillar =1 st shelf at sides748720073877587.

1

Detector position August 2005, supplement May’06

sub- detector mean Z delta Z Z_start Z_end

TT  2485 430 2270 2700

First pillar =1st shelf at sides 7487 200 7387 7587

clearance 51

inner tracker T1 7733 190 7638 7828

outer tracker T1 7948 220 7838 8058

clearance 11

2nd shelf in middle 8185 231

total 8069only shelf 8100

83008300

clearance 10

inner tracker T2 +MFD 8400 220200

envelope 8290 at level of RASNIK 8310

8510

outer tracker T2 8630 220 8520 8740

clearance   40

Second pillar = 3rd shelf 8880 200 8780 8980

clearance 25

inner tracker T3 9100 190 9005 9195

outer tracker T3 9315 220 9205 9425

Extra pillar 8880 200 8780 8980

RICH2 9450

Page 2: 1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT 248543022702700 First pillar =1 st shelf at sides748720073877587.

2

RASNIK position on C-frame

90

100

90

100

60

100

pillar

the edge of C-F

rame

left right

101.25

C-Frame

680

600 440

60

240285200

30

x=-5

6.6

x=+

33.4

x=+

134.

6

x=+

224.

6

x=0

y=0 beam

90

340(S2) 172(S3)

83

y=-2925

6050

/2=

3025

1.25

cable goes out from mask horizontally( not rotated by 120º )

Page 3: 1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT 248543022702700 First pillar =1 st shelf at sides748720073877587.

CCD on shelves

90

100

90

100

60

100

pillar

the edge of C-F

rame

101.25

C-Frame

240

90

y=-2925 22

4545270

y=0 beam

Cameras for C-frame 2 1 1 2 2-nd shelf4 3 3 4 2-nd shelf6 5 5 6 3-rd shelf

Cameras for C-frame1st pillar 1 22nd pillar 3 42nd pillar 5 6

3

Page 4: 1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT 248543022702700 First pillar =1 st shelf at sides748720073877587.

4

CR

YO

GE

NIC

S Z AXIS

(BEAM) INSIDE

PICTURE

LONG

STATION 1C-FRAME PLANE 1

SHORT

OT1

LONG

STATION 1C-FRAME PLANE 2

SHORT

LONG

STATION 3C-FRAME PLANE 5

SHORT

OT3

LONG

STATION 3C-FRAME PLANE 6

SHORT

DV

- 120u

m M

AS

K, rev

ersed

ho

lde

r IN F

RO

NT

OF

C-F

RA

ME

DX

- 340u

m M

AS

K, rev

ersed

ho

lde

r IN F

RO

NT

OF

C-F

RA

ME

H I - 340

um

MA

SK

, HO

LD

ER

BE

HIN

D C

-FR

AM

E

LONG

STATION 2C-FRAME PLANE 3

SHORT

OT2

LONG

STATION 2C-FRAME PLANE 4

SHORT

B - 340u

m M

AS

K- H

OL

DE

R B

EH

IND

C-F

RA

ME

E - 30u

m M

AS

K +

lon

g H

. + len

s o

n th

e sam

e C-F

RA

ME

F - 85u

m M

AS

K +

sho

rt H. +

lens

on

the sam

e C-F

RA

ME

LENS

Page 5: 1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT 248543022702700 First pillar =1 st shelf at sides748720073877587.

5

convention for masks installation on table level - top view

341036

00

-5

~185

Long C-Frame

- 56

.6

+33

.4

+13

4.6

+22

4.6

2nd

left pillar

1st left pillar

Short C-Frame

12

34

56

12

34

56

Outer Outer

+5

2nd

rightpillar

1st right pillar

Inner- 120µm mask

H3 B3 H3 B3

D

H1 B1

F

I2 B2

H13 B123 D E F I2 – lens type

EE

magnet

- 30 / 85µm mask + lens- reversed holders

- 340µm maskRICH2

Z

X

T1-Q13-XUT1-Q13-VX

T2-Q13-XUT2-Q13-VX

T3-Q13-XUT3-Q13-VX

T1-Q02-XUT1-Q02-VX

T2-Q02-XUT2-Q02-VX

T3-Q02-XUT3-Q02-VX

D

Page 6: 1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT 248543022702700 First pillar =1 st shelf at sides748720073877587.

6

Shelves Location & different kind Number of lines on shelf

Number of shelves

on table, under rails 8 2

on table, under rails 4 2

on 1st pillar 2 4

on 2nd pillar 4 4

long vertical lines on bunker 1 2

TOTAL 50 14This picture for 2nd pillars

BEAM IS TILTED, use shelves with identical thickness => No up-down symmetry inchoice of holes for 2nd & 3rd station,Upper raw for 2nd station,Lower raw for 3rd station.

Page 7: 1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT 248543022702700 First pillar =1 st shelf at sides748720073877587.

7

Shelves on 1st pillar

Use identical, short shelves =>up-down symmetry,lines only in outside raw.

Shelvesare adjustablein x and y by +/- 10mm

Page 8: 1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT 248543022702700 First pillar =1 st shelf at sides748720073877587.

8

Fixing shelf in the middle bottom vs OT2 or OT3

200

100

OT

5th C

-Fram

e

OT

6th C

-Fram

e

IT

115

75

14 shelf

43

190/220 220

-3025

level of table surface -3140= -6300+2400+760

Lens fixedCCD adjustable in z with range 40

153

10

21

120

15+e

b a line of sight in IT

adjustablein x & y

(A,B) 10

(C,D) 28

0 A

+5 D

Lines lengthened

by reversing mask holder

and lens holder

C – to see full 9*9 segment

on any mask

D – to increase depth of focus

-2987

0 Bmask

+5 C

Z

Z

Page 9: 1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT 248543022702700 First pillar =1 st shelf at sides748720073877587.

lens + mask’s holder on C-frames – OT1O

T 1

st C

-Fra

me

44

A=38

OT

2nd

C-F

ram

e

44

A=27

21

32

9

STOP

1644

ENVELOPE 100

EN

D O

F M

AS

K A

T E

ND

OF

EN

VE

LO

PE

ADJUSTMENT +- 5

A=38 or 274,5

6

6

32+4,5 +-5 or

21+4,5 +-5

Page 10: 1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT 248543022702700 First pillar =1 st shelf at sides748720073877587.

LONG VERTICAL LINES TO THE BRIDGE

lens

mask

x z

y

CCD

Two lines measuredisplacement of the bridge in horizontal directions x & z with precision of a few micronsvertical (y1mm) not used

6.7m

1.7m +margins 2m

Page 11: 1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT 248543022702700 First pillar =1 st shelf at sides748720073877587.

11

Tool for adjusting shelf to C-frameThis tool helps:1) make runners on shelf perpendicular to one C-frame (in x-z plane and in y-z plane)

2) adjust (in x and in y) shelf to hole in one C-frame

for every shelfon nearest C-framein hole without mask holder

|(2ndC-frame)-(far end of 1st new middle shelf)|-5==501500

x

y

Then adjust shelf versus cylinder

z

y

Pill

ar (

on s

ides

)

front view

side view

C-frame stop mechanism ON

First install cylinder