1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.
-
Upload
maximo-calton -
Category
Documents
-
view
215 -
download
1
Transcript of 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.
![Page 1: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/1.jpg)
1
DECONTAMINATION
(INDUSTRIAL APPLICATION)
M. Detilleux
Belgatom
![Page 2: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/2.jpg)
2
Decontamination / Industrial Application
Reference to the PHARE ProjectTechnical Design for Decommissioning
Kozloduy NPP Units 1&2
Task 2Decontamination and Cleaning
Operations
![Page 3: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/3.jpg)
3
Decontamination / Industrial Application
• Primary Circuit
• Nuclear Auxiliary Systems
• Reactor and Spent Fuel Pools
• Thermal Insulation Sheathing Materials
![Page 4: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/4.jpg)
4
Primary Circuit
Primary Circuit Components
The pipe works The SGs tubes and collectors The pressuriser The reactor vessel with the internals The main coolant pumps and isolation valves The hot portion of the SV01 circuit
![Page 5: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/5.jpg)
5
Primary Circuit
Two steps
• Soft Pre Decontamination
• Hard Decontamination
![Page 6: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/6.jpg)
6
Soft Pre Decontamination
Preference to the APCE process
pH must be > 5.5 due to absence of stainless steel cladding in the RPV and in the pressuriser
The type of secondary wasteAPCE : liquid waste processed by SV03 system
CORD: highly active IERs APCE process already used Experience of the staff and Availabilty of the
chemical dosing systems
![Page 7: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/7.jpg)
7
Hard Decontamination
Main Guidelines considered
Objective to achieve the EU free release levels
Regenerative Cerium process selected as proven technology currently available
![Page 8: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/8.jpg)
8
3 Options considered for the primary circuit
1. On-line hard decontamination of the 6 loops during the SE preparatory phase
2. No-Hard decontamination; at the end of the SE the components are dismantled, immobilised without decontamination
3. Hard decontamination in batches in an auxiliary unit on the dismantled components at the end of the SE phase
![Page 9: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/9.jpg)
9
On-line Hard Decontamination
Must be performed during the SE preparatory phase (operability and tightness of the circuit)
Must have a reasonable assurance to reach the free release levels for most equipment
‼ In the case of KNPP, to much plugging rate of the SGs tube’s and to difficult to remove (or to drill) the plugs on an economical basis
Option abandoned
![Page 10: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/10.jpg)
10
Cost Benefit Analysis
Cj = Aj + Nj . V . X
Cj = overall cost of option j
Aj = total cost for the process Nj = number of final packages V = volume of the final package X = final disposal unit cost
![Page 11: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/11.jpg)
11
Aj Items for processing costs
Investment fixed costs Consumable costs
- Chemical reagents
- Final packages
- Products for final conditioning (cementation)
- Steam, electrical energy, auxiliay fluids Manpower costs (for decontamination and
waste conditioning) Personnel radiological exposure costs
![Page 12: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/12.jpg)
12
Factors influencing Nj
Total weight criteria- Internal concrete shielding- Maximum weight (licensing and handling)
Chemical concentration- Limit for total salts content (240 gr / l)
Contact dose rate (handling and transportation)
Activity inventory- WAC for critical nuclides
![Page 13: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/13.jpg)
13
No-Hard Decontamination
Direct dismantling after SE, and conditioning the cut equipment
For SGs tubes, two cases
Without supercompaction With supercompaction
![Page 14: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/14.jpg)
14
No-Hard Decontamination
Equipment Nj Criterion
6 loops
6 SGs tubes bundels
12 SGs collectors
1 pressuriser
6 Main coolant pumps
12 Main isolation valves
6
20 to 25
12
10
10
7
Weight
α activity, geometry
weight
weight
Weight
weight
Total 70
![Page 15: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/15.jpg)
15
No-Hard Decontamination
With supercompaction ∆ cost = - 7%
Less volume Additional costs
- More operations for cutting in small lenghts
- More handling operations
- More secondary waste
- More Manpower and Man.Sv exposure costs
![Page 16: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/16.jpg)
16
Hard Decontamination, SGs tube excluded
• Hard Decontamination in batches(segmented components)
Compared to option 1 2X more reagents Volume of liquid waste is lower Volume of sludges is unchanged
• SGs tubes :cutting, conditioning with or not SC
![Page 17: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/17.jpg)
17
Hard Decontamination,SGs tubes included
Significative increase of the surfaces
Increase of the size and the capacity
- of the decontamination unit (50 m² / batch in place of 10-20 m² / batch)
- of the waste conditioning unit
![Page 18: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/18.jpg)
18
Results for Nj by option
Option
Nj
Soft pre decontamination before SE 19
No-hard decontamination 65 to 70
Hard decontamination (all equipment, ex SGs tubes) 25 to 30
Hard decontamination (all equipment) 19
![Page 19: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/19.jpg)
19
Cost Benefit Analysis
Result (cheapest option)
Soft decontamination after Reactor Final Shutdown
Hard decontamination (all equipment) during the differed dismantling (at the end of the SE)
Batch process applied on segmented components
![Page 20: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/20.jpg)
20
SGs decommissioning alternate options
• SGs melting option (Yankee Row, Kewaunee, Obrigheim NPPs)
• SGs entombment option(Loviisa NPP)
![Page 21: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/21.jpg)
21
Nuclear Auxiliary Systems
Cold portion of following systems
• SV 01 Purification system of the primary circuit
• SV 02 Liquid waste collecting system
• SV 03 Liquid waste processing system
• SV 04 Spent fuel storage pools cooling down and purification systems
![Page 22: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/22.jpg)
22
Nuclear Auxiliary Systems
No APCE Soft Pre Decontamination
• Technical reasons
Need to circulate solutions at high temperature (110 – 160 °C)
≠ Systems operated at low temperature and not provided with thermal insulation
Complexity of the pipework circuits, difficulty to arrange circulation decontamination loops
![Page 23: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/23.jpg)
23
Nuclear Auxiliary Systems
No APCE Soft Pre Decontamination
• Radiological reasons
Internal β-γ and α surfacic contamination is low
(1 to 2 order of magnitude than the primary circuit at the Reactor Final Shutdown)
![Page 24: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/24.jpg)
24
Reactor and Spent Fuel Pools
Selection of the decontamination process
Chemical- Too large volumes- Unfavourable geometry for recirculation
Ultra-sonic- Industrial experience in western PWRs- Easy to be implemented- Removal of cruds with immersed filter cartridges- DFs in the range of 5 to 50
![Page 25: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/25.jpg)
25
• Patented submerged filter system UWF 120-4
• Reactor vessel pool and spent fuel pool
• Reduces activity and turbidity
• Outage time reduction
Pool Cleaning Filtration
![Page 26: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/26.jpg)
26
A
8
B
C
7 6 5
D
E
F
8 67 5
A
B
C
4 23
D
E
1
F
V99999-33-0105 1296"0"
Pool CleaningWorking Positions
05.12.9605.12.96
Submersible Filter System UWF 120balduf Verfahrenstechnik GmbHD-71720 Oberstenfeld GermanyPhone +49 (0) 7062 94220
A
8
B
C
7 6 5
D
E
F
8 67 5
A
B
C
4 23
D
E
1
F
V99999-33-0105 1296"0"
Pool CleaningWorking Positions
05.12.9605.12.96
Submersible Filter System UWF 120balduf Verfahrenstechnik GmbHD-71720 Oberstenfeld GermanyPhone +49 (0) 7062 94220
UWF Working Position
![Page 27: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/27.jpg)
27
A
8
B
C
7 6 5
D
E
F
8 67 5
A
B
C
4 23
D
E
1
F
V99999-33-0205 1296"0"
Pool CleaningChange-out Position
05.12.9605.12.96
Submersible Filter System UWF 120balduf Verfahrenstechnik GmbHD-71720 Oberstenfeld GermanyPhone +49 (0) 7062 94220
A
8
B
C
7 6 5
D
E
F
8 67 5
A
B
C
4 23
D
E
1
F
V99999-33-0205 1296"0"
Pool CleaningChange-out Position
05.12.9605.12.96
Submersible Filter System UWF 120balduf Verfahrenstechnik GmbHD-71720 Oberstenfeld GermanyPhone +49 (0) 7062 94220
UWF Filterelement Change Out
![Page 28: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/28.jpg)
28
Booster UWS 30-1
• Suction installation as a water jet pump
• Handling: dimension as a fuel assembly
• Suction direct at the machine
![Page 29: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/29.jpg)
29
Bottom- and Wall Cleaning
A
8
B
C
7 6 5
D
E
F
8 67 5
A
B
C
4 23
D
E
1
F
V99999-33-1005 1296"0"
Pool Cleaning05.12.9605.12.96
Submersible Filter System UWF 120balduf Verfahrenstechnik GmbHD-71720 Oberstenfeld GermanyPhone +49 (0) 7062 94220
Combination between UWF andBooster with bottom cleaner
A
8
B
C
7 6 5
D
E
F
8 67 5
A
B
C
4 23
D
E
1
F
V99999-33-1005 1296"0"
Pool Cleaning05.12.9605.12.96
Submersible Filter System UWF 120balduf Verfahrenstechnik GmbHD-71720 Oberstenfeld GermanyPhone +49 (0) 7062 94220
Combination between UWF andBooster with bottom cleaner
![Page 30: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/30.jpg)
30
Cleaning of the Reactor Vessel
A
8
B
C
7 6 5
D
E
F
8 67 5
A
B
C
4 23
D
E
1
F
V99999-33-0905 1296"0"
Pool Cleaning05.12.9605.12.96
Submersible Filter System UWF 120balduf Verfahrenstechnik GmbHD-71720 Oberstenfeld GermanyPhone +49 (0) 7062 94220
Combination between UWF andBooster with corner extraction
A
8
B
C
7 6 5
D
E
F
8 67 5
A
B
C
4 23
D
E
1
F
V99999-33-0905 1296"0"
Pool Cleaning05.12.9605.12.96
Submersible Filter System UWF 120balduf Verfahrenstechnik GmbHD-71720 Oberstenfeld GermanyPhone +49 (0) 7062 94220
Combination between UWF andBooster with corner extraction
![Page 31: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/31.jpg)
31
Thermal Insulation and sheathing Materials
Immediate Removal( after decontamination of the primary circuit)
Not suited for long term conservation Corrosion of sheating materials Generation of dust and aerosols from glass
wool materials
![Page 32: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/32.jpg)
32
Conditioning options
• Thermal insulation material
Precompaction (50 t) into drums (110 kg / 210 l drum)
Supercompaction (910 t) Height reduction factor of 3
Immobilisation with concrete in the final package
Overall volume reduction factor = 4.7
![Page 33: 1 DECONTAMINATION (INDUSTRIAL APPLICATION) M. Detilleux Belgatom.](https://reader036.fdocuments.in/reader036/viewer/2022062511/5519add15503460a498b456c/html5/thumbnails/33.jpg)
33
Conditioning options
• Sheathing materials
Two options
Pre compaction, supercompaction, immobilisation (‼ aluminium)
Decontamination to reach free release levels