1
Data Center Energy Efficiency Metrics
ASHRAEJune 24, 2008
Bill TschudiLawrence Berkeley National Laboratory
![Page 2: 1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory wftschudi@lbl.gov.](https://reader036.fdocuments.in/reader036/viewer/2022070404/56649f395503460f94c556de/html5/thumbnails/2.jpg)
Metrics in use
• DOE Save Energy Now
• EPA Energy Star for Buildings
• LBNL Benchmarking
![Page 3: 1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory wftschudi@lbl.gov.](https://reader036.fdocuments.in/reader036/viewer/2022070404/56649f395503460f94c556de/html5/thumbnails/3.jpg)
DOE Save Energy Now “DC Pro” key elements
Data Center PerformanceData Center Performance• Overall energy performance (baseline) of data center
• Performance of IT & infrastructure subsystems compared to benchmarks
• Potential areas for efficiency improvement
• Energy cost ($), source energy (Btu), and carbon emissions (Mtons)
IT ModuleIT Module
• Servers
• Storage & networking hardware
• Software
Power SystemsPower Systems
• UPS
• Distribution
CoolingCooling
• Chillers
• CRAC units
• Fan power
Energy SourceEnergy Source
• Source of power
• Distributed generation
• Cost per kWh
• Backup power
![Page 4: 1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory wftschudi@lbl.gov.](https://reader036.fdocuments.in/reader036/viewer/2022070404/56649f395503460f94c556de/html5/thumbnails/4.jpg)
DCIE - (rating your data center)
DCiE = IT Energy/Total DataCenter Energy
![Page 5: 1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory wftschudi@lbl.gov.](https://reader036.fdocuments.in/reader036/viewer/2022070404/56649f395503460f94c556de/html5/thumbnails/5.jpg)
Other Data Center Metrics:• Power distribution: UPS efficiency, IT power supply
efficiency• HVAC
– IT total/HVAC total– Fan watts/cfm– Pump watts/gpm– Chiller plant (chiller or overall HVAC system) kW/ton
• Lighting watts/square foot• Rack cooling index (fraction of IT within ASHRAE
recommended temperature range)• Return temperature index (RAT-SAT)/ITΔT (a
measure of mixing of air in the data center)
![Page 6: 1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory wftschudi@lbl.gov.](https://reader036.fdocuments.in/reader036/viewer/2022070404/56649f395503460f94c556de/html5/thumbnails/6.jpg)
500 Boylston St.Boston, MA
Blue Earth County CourthouseMankato, MN
ENERGY STAR for BUILDINGS
Westin San Francisco Airport
Millbrae, CA
Shriner’s Hospital for ChildrenHouston, TX
Twin Peaks Charter AcademyLongmont, CO
AEGON CenterLouisville, KY
![Page 7: 1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory wftschudi@lbl.gov.](https://reader036.fdocuments.in/reader036/viewer/2022070404/56649f395503460f94c556de/html5/thumbnails/7.jpg)
EPA’s Energy Performance Rating System
• Obtaining data on IT energy use and total data center energy use for large sample of data centers (voluntary effort) over 12-month period
• Collecting data to analyze key variables. Adjustments may be made to account for factors such as climate or tier level
• Rank performance on scale of 1-to-100 where one point represents one percentile of the sample
• Top quartile eligible for Energy Star label
• Usable for both stand-alone data centers and data centers housed within office or other buildings
• Data must be measured in a consistent way
• To date 100 organizations with over 198 centers are participating
![Page 8: 1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory wftschudi@lbl.gov.](https://reader036.fdocuments.in/reader036/viewer/2022070404/56649f395503460f94c556de/html5/thumbnails/8.jpg)
Data Needed to Build Rating
• Required data
– Climate zone (zip code)
– Type of data center (function)
– Reliability (Tier Level)
– Total IT plug energy (12 months of data)
– Total facility energy usage (12 months of data for all fuels)
• Data needed from a wide variety of facilities (large/small, stand-alone/within larger bldg, etc.)
• EPA estimates that good data from at least 100 data centers is needed in order to develop the rating
![Page 9: 1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory wftschudi@lbl.gov.](https://reader036.fdocuments.in/reader036/viewer/2022070404/56649f395503460f94c556de/html5/thumbnails/9.jpg)
ENERGY STAR Data Center Rating Goals
• Ideal high level metric: kBtu / useful work• Challenge: how to measure “useful work”?• Next Steps
– Agree on “useful work” – challenge industry to reach consensus
– Implement working metrics for end users while industry determines definition of “useful work”
![Page 10: 1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory wftschudi@lbl.gov.](https://reader036.fdocuments.in/reader036/viewer/2022070404/56649f395503460f94c556de/html5/thumbnails/10.jpg)
LBNL Benchmarking - Energy End Use
Data Center Server Load
51%
Data Center CRAC Units
25%
Cooling Tower Plant4%
Electrical Room Cooling
4%
Office Space Conditioning
1%
Lighting2%
Other13%
Computer Loads67%
HVAC - Air Movement
7%
Lighting2%
HVAC - Chiller and
Pumps24%
The relative percentages of the energy actually doing computing vary considerably.
![Page 11: 1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory wftschudi@lbl.gov.](https://reader036.fdocuments.in/reader036/viewer/2022070404/56649f395503460f94c556de/html5/thumbnails/11.jpg)
Data center infrastructure efficiency (DCiE)
IT Power to Total Data Center Power
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Data Center Number
Ra
tio
Average .57
Higher is better
Source: LBNL Benchmarking
![Page 12: 1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory wftschudi@lbl.gov.](https://reader036.fdocuments.in/reader036/viewer/2022070404/56649f395503460f94c556de/html5/thumbnails/12.jpg)
DOE Data Center program
Paul Scheihing
www.eere.energy.gov/industry
202-586-7234
Energy Star Buildings Program
Mike Zatz
www.energystar.gov/datacenters
202-343-9152
Lawrence Berkeley National Laboratory
Bill Tschudi
http://hightech.lbl.gov/datacenters.html
510-495-2417
DC Pro tool: www.eere.energy.gov/datacenters