1 2 3 4 in the `Approved'-field....This document is issued by means of a computerized system. The...

2
This document is issued by means of a computerized system. The digitally stored original is ele ctronically approved. The approved document has a date entered in the `Approved'-field. A manual signature is not required. Drawing sheet ISO 5457-A4T rev A We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved. D C B E F 1 2 3 4 C D 470 A 200 200 200 200 200 223 600 710 740 24x 15 43 B 1447 304 126 140 310 1491 100 255 255 98 6 45 4x 14 C/L Diverter switch 30 460 730 821 671 60 373 723 1073 332 50 30 255 27 111 205 C/L Top Flange 80 () 373 100 100 100 INSULATION380 1050 SHORT VERSION b) LEVEL kV 650 380,650 750 750 1050 A2801 a)3101 a)2581 a)2881 a) Dimen- sions in mm B1354 a)1654 a)1134 a)1434 a) C 119 a)c) 119 a) 119 a)c) 119 a) D 240 c) 540 240 c) 540 1/2 EN C 1ZSC004528-AAT Sheet Language Revision Document Id. VUCGR, VUCGD N XXXX/450,800/F 9,13 Pos TAP-CHANGER Title DIMENSION DRAWING PPCO/TU 2015-09-15 Document Kind Responsible department Date / Approved Diverter switch terminal, no 30. 1) Shielding rings for insulating levels 650, 750 and 1050 kV only a) For mounting on active part use A+106,B+10 and C+106 (See also Drawing 54920103-1) b) Short version means reduced switching capa Please refer to Technical Guide c) Not applicable for 380 kV A A V 2..12. V 2..12. V 2..12. H 1..13. H 1..13. H 1..13. 1) 1) B B C/L Tap selector Transformer Flange 1) 1) Lover ring not for short version C C C - C

Transcript of 1 2 3 4 in the `Approved'-field....This document is issued by means of a computerized system. The...

Page 1: 1 2 3 4 in the `Approved'-field....This document is issued by means of a computerized system. The digitally stored original is electronically approved. The approved document has a

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

Drawing sheet ISO 5457-A4T rev A

We reserve all rights in this document and in the information contained

therein. Reproduction, use or disclosure to third parties without express

authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved.

D

C

B

E

F

1 2 3 4

CD 470

A

200

200

200

200

200

223

600

710

740

24x 15

43

B1447

304

126

140 310

1491

100

255 255

98

6 45

4x 14

C/L Diverter switch30

460 730

821

671

60

373

723

1073

332

50

30255

27

111 205

C/L Top Flange80(

)373

100

100

100

INSULATION380 1050 SHORT VERSION b)LEVEL kV 650 380,650

750 750 1050A 2801 a)3101 a)2581 a)2881 a)Dimen-

sionsin mm

B 1354 a)1654 a)1134 a)1434 a)C 119 a)c)119 a) 119 a)c)119 a)D 240 c) 540 240 c) 540

1/2ENC1ZSC004528-AAT

SheetLanguageRevisionDocument Id.

VUCGR, VUCGD N XXXX/450,800/F 9,13 Pos

TAP-CHANGER

Title

DIMENSION DRAWING PPCO/TU2015-09-15

Document KindResponsible departmentDate / Approved

Diverter switch terminal, no 30.

1) Shielding rings for insulating levels 650, 750 and 1050 kV only.

a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1)b) Short version means reduced switching capacity. Please refer to Technical Guidec) Not applicable for 380 kV

A A

V 2..12.

V 2..12.

V 2..12.

H 1..13.

H 1..13.

H 1..13.

1)

1)

B B

C/L Tap selector

Transformer Flange

1)

1)

Lover ring not forshort version

C

C

C - C

Page 2: 1 2 3 4 in the `Approved'-field....This document is issued by means of a computerized system. The digitally stored original is electronically approved. The approved document has a

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

Drawing sheet ISO 5457-A4T rev A

We reserve all rights in this document and in the information contained

therein. Reproduction, use or disclosure to third parties without express

authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved.

D

C

B

E

F

1 2 3 4

44

48

13

25

651

1081

340

250140

260

85

920

95

95

25

165

165

60

60

135

135

90

490

12x 18

260 415

30�$�

70�$�

36�$�

40�$�

72�$�

36�$�

36�$�

36�$�

36�$� 36�$�

36�$�

36�$�36�$�

36�$�36�$�

70�$�

30�$�

40�$�

72�$�

36�$�

ADDITIONAL DRAWINGS:Connection Diagrams:See Technical Guide UCMounting on active part: 54920103-1Accessories:54920103-2Motor Drive BUL:54830001-1Motor Drive BUE:54830001-2 or -3External Drive Shaft:54920083-4Pressure Relay:54920083-2Bevel Gear:54920083-1

2/2ENC1ZSC004528-AAT

SheetLanguageRevisionDocument Id.

VUCGR, VUCGD N XXXX/450,800/F 9,13 Pos

TAP-CHANGER

Title

DIMENSION DRAWING PPCO/TU2015-09-15

Document KindResponsible departmentDate / Approved

D

T=14,7

B - B

9 POSITIONS

13 POSITIONS

1

2/3

4/5

6/7

8/9

1

2/3

4/5

6/7

8/9

10/1112/13

20

21

22

20

21

22

R297

R297

A - A

A - A

V

H

V

H

Current Collector

D