060 - Procurement & Strategic Sourcing · w.w.f. welded wire fabric u/c undercut wide vinyl base...
Transcript of 060 - Procurement & Strategic Sourcing · w.w.f. welded wire fabric u/c undercut wide vinyl base...
18
"
TELEPHONE
WALL JACKS
48
" M
AX
.
48
" M
AX
.
48
"
HVAC CONTROLS
PUSH BUTTON
KEY SWITCH or
FORWARD APPROACH
ST
D.
18
" FIN.FLR.LINE
DUPLEX OUTLET
4" MIN.
FIN.FLR.LINE
PARALLEL APPROACH
FIN.FLR.LINE
PUSH BUTTON
FIN.FLR.LINE
KEY SWITCH or
WALL
COORDINATE WITH SCHEDULE
DOOR DESIGNATION
KEY NOTE DESIGNATION NUMBER -
COORDINATE WITH PLAN NOTES
COORDINATE WITH PLAN NOTES
EQUIPMENT DESIGNATION NUMBER -
ADDENDUM DESIGNATION NUMBER
BULLETIN DESIGNATION NUMBER
BLOCKING/ROUGH LUMBER
BATT/LOOSE INSULATION
ACOUSTICAL CEILING
FINISHED WOOD
GYPSUM WALLBOARD
PARTICLE BOARD
WALL TYPE DESIGNATION NUMBER -
SHEET REFERENCE FOR DRAWING CONTINUATION
PLYWOOD
MASONRY
GLASS
CONCRETE
48
"
or DIMMER
LIGHT SWITCH
4'-0
"
DESK
MATCH LINE
REF: A3
17
1
1
12
FIN.FLR.LINE
1
XX
XX
SW. SWITCH
UNLESS NOTED OTHERWISE
TONGUE AND GROOVE
VINYL COMPOSITION TILE
WELDED WIRE FABRICW.W.F.
U/C UNDERCUT
WIDE
VINYL BASE
VERTICAL
VERIFY IN FIELD
WAINSCOT
WATER CLOSET
WEIGHT
WOOD WINDOW
W.
W.C.
WD.WIN.
WT.
WAINS.
VERT.
V.C.T.
V.I.F.
U.N.O.
V.B.
SYMMETRICAL
TREAD
THICK, THICKNESS
THRESHOLD
TERRAZZO
TELEPHONE
TOP AND BOTTOM
TYPICAL
TOP OF STEEL
THRES.
TYP.
T.O.S.
THK.
T&G
T&B
TERR.
TEL.
SYM.
T.
MISCELLANEOUS IRON
POUNDS PER SQUARE FOOT
PROJECT, PROJECTION
REINFORCED, REINFORCING
REFLECTED CEILING PLAN
R.B. RUBBER BASE
SAN. SANITARY
SCHEDULE
SHEET
STORAGE
STRUCTURAL
STANDARD
SERVICE SINK
SPECIFICATION
STEEL
SIMILAR
SUSPENDED
STRUCT.
SUSP.
STL.
STOR.
STD.
SIM.
SPEC.
S.S.
SCHED.
SHT.
ROOF CONDUCTOR
RUBBER FLOORING
ROOF SUMP
ROOM
REQUIRED
ROOFING
ROOF DRAIN
RUBBER TILE
R.S.
R.T.
REQ'D.
RFG.
RM.
R.D.
REINF.
R.F.
R.C.P.
R.C.
PLATE GLASS
PLATE STEEL
PLASTIC LAMINATE
PREFABRICATED
PAINT, POINT
RISER
PLASTER
RETURN AIR
PROJ.
R.
R.A.
P.S.F.
PT.
PREFAB.
P.LAM
PLAS.
PL.G.
PL.S.
MEZZANINE
OUTSIDE DIAMETER
NOT IN CONTRACT
MASONRY OPENING
MINIMUM
ON CENTER
NOT TO SCALE
MISCELLANEOUS
OPPOSITE
OPENING
N.I.C.
O.D.
OPP.
OPNG.
N.T.S.
O.C.
MIN.
MISC.
M.O.
MEZZ.
M.I.
ELEVATION NUMBER
DETAIL REFERENCE NUMBER
ELEVATION NUMBER
HEIGHT ABOVE FINISHED FLOOR
REFERENCE POINT OF ELEVATION
HEIGHT ABOVE FINISHED FLOOR
EXISTING DOOR SYMBOL
CIRCLES REPRESENT NEW COLUMN LINES
LETTERS DESIGNATE HORIZONTAL COLUMN LINES
DASHED CIRCLES REPRESENT EXISTING COLUMNS
NUMBERS DESIGNATE VERTICAL COLUMN LINES
SHEET NUMBER WHERE DETAIL IS REFERENCED
NOTE: DATUM SYMBOL INDICATES A SPECIFIC
REFERENCE HEIGHT OF MATERIAL INDICATED
SHEET NUMBER WHERE DETAIL IS LOCATED
SHEET NUMBER WHERE ELEVATION IS LOCATED
DARKENED ARROW INDICATES ELEVATED SECTION
SHEET NUMBER WHERE ELEVATION IS LOCATED
NEW DOOR SYMBOL
B
A
1
1" = 1'-0"
B./CEILING
EL. 8'-0" A.F.F.
8'-0"
ROOM NAME
0000000
A-8
ROOM NUMBER
ROOM NAME
DRAWING SCALE
DETAIL
A-8
12
12
1
A-5
A-5
1
2
DETAIL NAME
DETAIL NUMBER
FIBER REINFORCED PANELS
EXPANSION, EXPOSED
LONG LEG VERTICAL
LONG LEG OUTSTANDING
F.O. FACE OF
JOINT
LONG
INSIDE DIAMETER
MAXIMUM
INTERIOR
LAVATORY
INSULATION
METAL
MECHANICAL
LG.
MAX.
MET.
MECH.
L.L.O.
L.L.V.
LAV.
JT.
INSUL.
I.D.
INT.
FACE OF STUD
FRAME
HORIZONTAL
GYPSUM
FOOTING
HARDWARE
GALVANIZED
HOLLOW METAL
GAUGE
HEIGHT
HORIZ.
HT.
GYP.
HDW.
H.M.
FTG.
GALV.
GA.
F.O.S.
FR.
EACH WAY
FLOOR DRAIN
FOUNDATION
EXISTING
EXTERIOR
EXISTING
FLOOR
FINISH
F.D.
FLR.
FIN.
FDN.
F.R.P.
EXIST.
EXP.
EXT.
EXG.
E.W.
DOWN
EACH
DIMENSION
DIAMETER
DRAWING
DOOR OPENING
DOOR
CERAMIC TILE
DETAIL
CARPET
ELEVATION
DN.
ELEV.
DWG.
EA.
D.O.
DR.
DET.
DIA.
DM.
CPT.
C.T.
ACOUSTIC CEILING TILE
ABOVE FINISH FLOOR
AT
CORNER GUARD
CEILING
CONCRETE
CLEAN OUT
COLUMN
CENTER LINE
CONTROL JOINT
CEMENT
CONTINUOUS
CORRUGATED
CONSTRUCTION
COL.
CONST.
CONT.
CORR.
CONC.
C.G.
L
C.O.
C
CEM.
CLG.
C.J.
ANODIZED
ALUMINUM
BUILDING
BLOCKING
BLOCK
BOARD
ACOUSTICAL
ADJACENT
ALUM.
BLDG.
BLKG.
BLK.
ANOD.
BD.
ACOUST.
A.F.F.
ADJ.
A.C.T.
@
FIELD VERIFYFV.
L40
PS-5
L21
PS
-6
045
088
L59A
PS-2
056
KIR
BY
202
PALMER
090
WILLIAMS MALL
L31
AN
TH
ON
Y W
AY
NE
D
RIV
E
LO
DG
E F
RE
EW
AY
U
. S
. 10
155
L51
167
156
150
L52
L53
L41
130
L41
134
L54
006
096
089
GU
LLE
N M
ALL
008
017
001
005
022
007
016
023
CA
SS
034
136
140
025
027
040
050
043
053
049
026
028
033
039
036
048
046
042
038
060
CA
SS
ANTOINETTE
PS-1
062
PA
LM
ER
PU
TN
AM
071
P
S
-3
637
499
E K
IR
BY
067
066
L
3
4
064F
E
R
R
Y
PS
5
1
1
509
510
H
E
N
D
R
IE
195
199
085
082
0
6
5
L15
L35
L36
L23
L33
041
115
L32
051
4
9
8
L37
L58
207
LUDINGTON MALL
GILMOUR MALL
REUTHER MALL
L22
38
087
104
JO
HN
R
0
7
0
127
H
O
L
D
E
N
A
V
E
.
YORK
FO
UR
TH
L17
141
YORK
O
O
W
A
R
W
D
D
( T
HIR
D )
191
193L11
E
A
S
T
W
E
S
T
063
GU
LLE
N M
ALL
A
R
D
CA
SS
FE
R
R
Y S
T E
PL
A
N
TO
IN
E
TT
E
PL
10
10
WEST WARREN
L39
L20
GENERAL
TS1.1 TITLE SHEET AND SHEET INDEX AND LOCATOR PLAN
ISSUED FOR
07
.0
9.1
5 9
0%
OW
NE
R R
EV
IE
W
PREVIOUSLY ISSUED
NOT ISSUED
DRAWING INDEX KEY:
REFERENCE
ISSUED
A1.1 FLOOR PLAN
NOTE:
THESE CONSTRUCTION DRAWINGS WERE PREPARED FOR COMPLIANCE WITH THE MICHIGAN
CONSTRUCTION CODES IN EFFECT AT THE TIME OF PERMIT SUBMITTAL. ALL ENGINEERS,
CONTRACTORS AND SUPPLIERS INVOLVED WITH THIS PROJECT SHALL COMPLY WITH THE
SAME CODES, ISSUED AND APPROVED CODE MODIFICATIONS AND/OR CITY CODE AUTHORITY
CONSTRUCTION BOARDS OF APPEALS RULINGS AND WHENEVER REQUIRED SHALL PROVIDE
SHOP DRAWINGS AND SUBMITTALS CLEARLY DESCRIBING COMPLIANCE TO THE REGISTERED
DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE FOR REVIEW AND APPROVAL.
VICINITY MAP
NOT TO SCALE
N
PROJECT SITE
D1.1 DEMO FLOOR PLAN/CEILING PLAN
ARCHITECTURAL
BUILDING CODE AUTHORITY:
CITY OF DETROIT/ WAYNE STATE UNIVERSITY
OWNER:
WAYNE STATE UNIVERSITY
5454 CASS AVE.
DETROIT, MI 48202
TYPE OF CONSTRUCTION:
IIB,NON-SPRINKLED
USE GROUP:
B-Business
A2.1 REFLECTED CEILING PLAN
APPLICABLE CODES:
BUILDING CODE
ALSO KNOWN AS THE "MICHIGAN BUILDING CODE"
2012 MICHIGAN BUILDING CODE (MBC) AS AMENDED
MECHANICAL CODE
ALSO KNOWN AS THE "MICHIGAN MECHANICAL CODE"
2012 MICHIGAN MECHANICAL CODE AS AMENDED
PLUMBING CODE
ALSO KNOWN AS THE "MICHIGAN PLUMBING CODE"
2012 MICHIGAN PLUMBING CODE AS AMENDED
ELECTRICAL CODE
ALSO KNOWN AS THE "MICHIGAN ELECTRICAL CODE"
2011 NATIONAL ELECTRIC CODE (NEC) AS AMENDED &
MICHIGAN AMMENDMENTS PART 8.
ENERGY CODE
2009 UNIFORM ENERGY CODE
BARRIER FREE REQUIREMENTS
AMERICANS WITH DISABILITIES ACT (ADA)
MBC-2009, CHAPTER 11
ICC / ANSI 117.1 - 2006, EXCEPT SECTION 611 & 707
A1.0 EXISTING PLAN, CODE STUDY & AREA OF WORK PLAN
A2.2 REFLECTED CEILING PLAN DETAILS
PS1.2 SPECIFICATIONS
PS1.1 SPECIFICATIONS
A7.1 MILLWORK DETAILS
A6.1 INTERIOR ELEVATIONS
A9.1 DOOR HARDWARE SCHEDULE
F1.1 FINISH FLOOR PLAN - 1ST FLOOR
MECHANICAL/PLUMBING
ELECTRICAL
M0.0 MECHANICAL SYMBOLS, LIST, INDEX AND NOTES
ED1.2 PARTIAL DEMOLITION 1ST FLOOR PLAN - POWERS + SYSTEMS
M0.1 MECHANICAL SPECIFICATIONS
MD1.1 DEMOLITION FLOOR PLAN - MECHANICAL
M1.1 NEW WORK FLOOR PLAN - MECHANICAL
ED1.1 PARTIAL DEMOLITION 1ST + 2ND FLOOR PLANS - LIGHTING
E0.1 ELEC. LEGENDS, SPEC., SHEET INDEX + LOAD SUMMARY
E1.1 PARTIAL 1ST + 2ND FLOOR PLANS - LIGHTING
E2.1 PARTIAL 1ST + 2ND FLOOR PLANS - POWER AND SYSTEMS
08
.0
4.1
5 O
WN
ER
R
EV
IE
W
F1.2 FINISH FLOOR PLAN - 2ND FLOOR
WSU FP & M Project No.: 193-258618
WSU Building No.: 193
SVA Project No.: 2015.002
08
.2
6.1
5 B
ID
S
09
.2
2.1
5 A
DD
EN
DU
M3
3
3
3
S
S
S
7'-4"
9'-0"
ETR
ETR
1. ALL DEMOLITION WORK REQUIRED IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON
THE DEMOLITION PLANS. THE INTENT IS TO REMOVE ALL MECHANICAL, ELECTRICAL, AND
ARCHITECTURAL ITEMS AS REQUIRED TO FACILITATE NEW CONSTRUCTION.
2. COORDINATE SCOPE AND EXTENT OF DEMOLITION WORK WITH NEW WORK PLANS AND
DETAILS.
3. ALL WALLS, DOORS, FRAMES, AND RELATED HARDWARE ASSEMBLIES DESIGNATED AS "TO
BE REMOVED" (SHOWN AS DASHED LINES) SHALL BE COMPLETELY REMOVED AND
DISPOSED OF AS DESIGNATED BY OWNER/TENANT. ALL EXISTING WALLS NOT
DESIGNATED FOR DEMOLITION SHALL BE PROTECTED FROM DAMAGE AND REMAIN "AS-IS".
4. ALL EQUIPMENT, DOORS, FRAMES, RELATED HARDWARE, AND DESIGNATED ITEMS TO BE
SALVAGED SHALL BE REMOVED, PROTECTED FROM DAMAGE, AND STORED FOR REUSE.
5. CLEAN AND REPAIR ALL EXISTING FLOOR FINISHES AS NECESSARY.
6. ALL DEMOLITION WORK SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER.
ALL SURFACES ADJACENT TO AND ABUTTING TO THOSE DESIGNATED "TO BE REMOVED"
SHALL BE LEFT WITH A SMOOTH AND FLUSH APPEARANCE.
7. THE CONTRACTOR SHALL EXERCISE ALL REQUISITE CARE NECESSARY TO ENSURE THAT
ALL EQUIPMENT, MATERIALS, FINISHES AND ASSEMBLIES WHICH ARE NOT BEING
REMOVED ARE PROTECTED FROM DAMAGE DURING DEMOLITION AND SUBSEQUENT
CONSTRUCTION OPERATIONS.
8. REFER TO MECHANICAL AND ELECTRICAL DEMOLITION DRAWINGS AND SPECIFICATIONS
FOR ADDITIONAL DEMOLITION INFORMATION.
9. GENERAL PRECAUTIONS SHALL BE TAKEN AS NECESSARY TO HOLD ALL DISRUPTION,
DUST, DIRT, NOISE, AND DEBRIS TO A MINIMUM.
10. THE CONTRACTOR SHALL COORDINATE DEMOLITION WORK WITH OWNER TO ENSURE
THAT IMPACTS ON THE BALANCE OF THE BUILDING ARE HELD TO A MINIMUM.
11. PREPARE ALL SURFACES TO RECEIVE THE NEW WORK AND FINISHES OF THE CONTRACT.
12. THE CONTRACTOR SHALL DESIGN, PROVIDE, INSTALL AND MAINTAIN ANY AND ALL
TEMPORARY BRACING AS REQUIRED TO ENSURE THE STABILITY OF THE BUILDING
ASSEMBLY AND/OR ANY SYSTEMS AND/OR SUB-ASSEMBLIES AND/OR SYSTEMS
APPURTENANT THERETO UNTIL SAID ASSEMBLY AND/OR SUB-ASSSEMBLIES ARE
COMPLETE, SELF-SUPPORTING AND/OR STABLE.
GENERAL DEMOLITION PLAN NOTES:
DEMOLITION PLAN KEY NOTES:
(TYPICAL THIS SHEET ONLY)
REMOVE EXISTING FLOORING AND BASE COMPLETE
REMOVE EXISTING MILL WORK, PREP PLUMBING AND SLAB AS REQ'D TO ACCOMMODATE
NEW WORK
REMOVE DOOR, FRAME AND HARDWARE COMPLETE
REMOVE PORTION OF WALL ABOVE 3'-6", KNEE WALL TO REMAIN, REWORK EXISTING
ELEC. AND DATA AS REQ'D TO ACCOMMODATE NEW WALL CONFIGURATION.
LAY-IN CEILING AND PADS TO REMAIN
NOT USED
REMOVE EXIST. LIGHT FIXTURE
REMOVE LAY-IN CEILING/PADS COMPLETE
LINE OF TERMINATION OF NEW LAY-IN CEILING
REMOVE DIFFUSER/SUPPLY
EXISTING FIRE STROBE TO REMAIN
REMOVE EXISTING COLUMN CLADDING TO EXPOSED STEEL COLUMN.
REMOVE PORTION OF WALL, PROVIDE LINTEL AS REQ'D FOR NEW DOOR OPENING
REMOVE SURFACE MOUNTED FIXTURE
REMOVE SURFACE MOUNTED FIXTURE AND DISCONNECT, PROVIDE WHITE BLANK COVER
PLATE AT EXISTING J-BOX TO REMAIN
LINE DEFINES GENERAL AREA OF WORK. ADDITIONAL WORK OR
INTERACTION WITH ADJACENT AREAS OUTSIDE BOUNDARY MAY
BE REQUIRED. LINE SHOULD NOT BE USED AS A CONSTRUCTION
SCOPE BOUNDARY.
D1
D2
WALL TO REMAIN
WALL TO BE REMOVED
DOOR TO REMAIN
DOOR, FRAME AND HARDWARE TO BE REMOVED UNLESS NOTED
OTHERWISE
DESIGNATED ITEM TO REMAIN
DESIGNATED ITEM TO BE REMOVED
DEMOLITION KEY:
7'-4"
D1
D1
D1
D1
D2
D3
D3
D3
D4
D5
D4
D4
D5
D5
D5
D5
D8
D6
D7
D7
D7
D7D7
D7 D7D7 D7
D7D7
D7D7
D7
D7
D7
D7
D7
D7
D7
D7
D7
D7
D7
D7
D7
D8
D8
D8
D9
D9
D10
D10D10
D10
D10
D11
D11
DEMOLITION 1ST FLOOR PLAN
SCALE: 1/8"=1'-0"
N
DEMOLITION 1ST FLOOR CELING PLAN
SCALE: 1/8"=1'-0"
N
D7
D7
D7
D7
D7
D7
D12
D12
D13
D13
D8
D13
D12
DEMOLITION 2ND FLOOR CELING PLAN
SCALE: 1/8"=1'-0"
N
D14
D15
D14
D14
D14
D14
D15
D16 D16
D16
D16
D9
D7
D7
D7
D7
D10
D10
D10
D10
D12
D9
D1
3
3
15'-3" 1'-6" 5'-7"5'-0"
5'-0
"1
3'-1
1"
18
'-0
"
26'-2"
17
'-8
"
11"
11
"
12'-10"
12
'-3
1
/2
"
15'-3" 1'-6" 5'-7"5'-0"
5'-0
"1
3'-1
1"
18
'-0
"
26'-2"
17
'-8
"
11"
11
"
12'-10"
12
'-3
1
/2
"
- 5/8" THK GYP. BD.
- MTL STUDS @ 16" O.C.
W/ SOUND BATT INSUL.
- 5/8" THK GYP. BD.
(1HR RATED ASSEMBLY
UL# U465)
(TYPICAL UNLESS
NOTED OTHERWISE)
- 5/8" THK GYP. BD.
- MTL STUDS @ 16" O.C. W/
BATT INSUL.
5/8"
SEE PLAN
WALL TYPE SCHEDULE
EX
TE
RIO
R W
AL
L
FR
AM
IN
G
NOTES:
* ALL WALL TYPES EXTEND FROM FLOOR TO UNDERSIDE ROOF/FLOOR DECK UNLESS NOTED OTHERWISE.
* REFER TO FLOOR PLAN FOR WALL THICKNESS.
* REFER TO CODE PLAN FOR WALL RATING REQUIREMENTS.
- SIMILAR TO TYPE 1A
EXCEPT LESS BATT
INSUL.
- 5/8" THK GYP. BD.
- 7/8" MTL HATCHANNEL
NO INSUL.
5/8"
SEE PLAN
5/8"
SEE PLAN
5/8"
1A 2B 3
1B
1. THIS DRAWING IS DIAGRAMMATIC AND SHOULD BE USED TO DETERMINE THE DESIGN
INTENT. THE CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE SET OF WORK AS
INDICATED AND SHALL FIELD VERIFY ALL WORK, COORDINATE ALL DRAWINGS / NEW WORK
AND SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DOCUMENTS
BEFORE PROCEEDING. FAILURE TO DO SO WILL RESULT IN THE CONTRACTOR TAKING
FULL RESPONSIBILITY AND LIABILITY FOR SAID DISCREPANCIES.
2. ALL DIMENSIONS ARE SHOWN FROM FINISH FACE TO FINISH FACE OF PARTITION UNLESS
OTHERWISE NOTED.
3. WALL THICKNESS' ARE NOMINAL NOT ACTUAL DIMENSIONS. SEE WALL SCHEDULE FOR
ACTUAL DIMENSIONS.
4. ALL WOOD, INCLUDING BLOCKING, USED ON THE PROJECT SHALL BE FIRE RETARDANT
TREATED.
5. ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL LOCAL, STATE, COUNTY CODE
REGULATIONS, O.S.H.A., AND THE AMERICAN WITH DISABILITIES ACT (ADA). REFER TO THE
CODE PLAN FOR MORE INFORMATION.
6. PROVIDE POSITIVE SLOPE TO ALL FLOOR DRAINS WHILE KEEPING FLOOR LEVEL AT WALL
BASE CONDITION.
7. PROVIDE TRANSITION STRIPS AT EACH CHANGE IN FLOOR FINISH MATERIALS.
8. PAINT, PATCH AND REPAIR THE FOLLOWING TO MATCH EXISTING MATERIALS: FLOOR,
WALL, AND CEILING SURFACES AS REQUIRED ADJACENT TO AREAS BEING DEMOLISHED.
REFER TO DEMOLITION DRAWINGS FOR MORE INFORMATION.
9. REINFORCE WALL AND PROVIDE BLOCKING AS REQUIRED TO SUPPORT WALL CABINETS
AND COUNTERTOPS.
10. THE CONTRACTOR SHALL PROVIDE AND INSTALL WALL REINFORCING FOR INSTALLATION
OF ACCESSORIES, COAT RACKS, CHART RACKS, CASEWORK, AND OTHER WALL MOUNTED
ITEMS.
11. CLEAN AND REPAIR ALL EXISTING FLOOR FINISHES AS NECESSARY.
12. ALL EXPOSED PIPES, DUCTS, AND CONDUIT TO BE PAINTED TO MATCH EXISTING.
13. PROVIDE CONTROL JOINTS IN GYPSUM BOARD PARTITIONS AT 30'-0" O.C. MAXIMUM AND AS
INDICATED IN THE CONTRACT DOCUMENTS.
14. COORDINATE WITH OWNER'S EQUIPMENT SUPPLIER FOR INSTALLATION REQUIREMENTS /
LOCATIONS OF FLOOR / WALL / CEILING MOUNTED ITEMS; IE. CAMERAS, TV'S, SPEAKERS,
SENSORS, SECURITY WIRING, VAULTS, ATM'S.
15. CONTRACTOR SHALL CONDUCT A ROUGH ELECTRICAL INSPECTION WITH OWNER, PRIOR
TO ENCLOSING WALLS, FOR THE PURPOSE OF CONFIRMING ALL J-BOX LOCATIONS FOR
POWER, DATA, VOICE, SWITCH, THERMOSTAT, ETC.
16. CONTRACTOR TO FILL ANY AND ALL EQUIPMENT PENETRATIONS OR DEPRESSIONS INTO
OR THROUGH THE EXISTING SLAB THAT WILL NOT BE UTILIZED TO FEED NEW EQUIPMENT
(I.E. ABANDONED FLOOR CORES, IMPRESSION FROM PREVIOUS EQUIPMENT FLOOR PLATE
REMOVAL). PENETRATIONS SHALL BE FILLED WITH NON-SHRINK GROUT. THE SIDES OF
ANY EXISTING OPENINGS SHALL BE MODIFIED/TAPERED SO THAT THEY ARE WIDER AT THE
TOP THAN AT THE BOTTOM. FOR LARGE OPENINGS, PROVIDE ONE (1) #5 BAR 2" UP FROM
BOTTOM OF HOLE.
17. A TACTILE SIGN STATING 'EXIT' AND COMPLYING WITH ICC-A117.1 SHALL BE PROVIDED
ADJACENT TO EACH DOOR TO AN 'AREA OF REFUGE', AN EXTERIOR AREA FOR ASSISTED
RESCUE, AN EXIT STAIRWAY, AN EXIT RAMP, AN EXIT PASSAGEWAY, AND THE EXIT
DISCHARGE.
18. PROVIDE PERMANENT 2-INCH HIGH LETTERING MARKING AND IDENTIFICATION AT ALL FIRE
WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS, SMOKE PARTITIONS OR ANY
OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS AT 30 FEET
MAXIMUM HORIZONTAL INTERVALS, MINIMUM 2 LOCATIONS EACH WALL, IN ACCESSIBLE
CONCEALED FLOOR, FLOOR-CEILING, OR ATTIC SPACES PER CODE.
GENERAL FLOOR PLAN NOTES:
FLOOR PLAN KEY NOTES:
(TYPICAL THIS SHEET ONLY)
NEW BUTT-GLAZED GLASS ON 3'-6" KNEE WALL, PROVIDE DATA AND
POWER AS REQ'D
NEW MILL WORK, PROVIDE PLUMBING TO ACCOMMODATE NEW SINK
MILLWORK PENINSULA, AT 42" AFF. PROVIDE PEDESTAL BASE SUPPORT
REFRIGERATOR BY OWNER
PROVIDE MILL WORK ABOVE COUNTER TOP FOR DOUBLE STACKED
MICROWAVE OVENS
36" ROUND TABLE AND CHAIRS (FOR REFERENCE ONLY,
ALL FURNITURE BY OWNER)
VENDING MACHINES (BY OWNER VENDOR)
NOT USED
PROVIDE NEW RUBBER FLOORING BY NORA AND RUBBER WALL BASE IN
CORRIDOR AND AT RAMP, COLOR TO BE SELECTED BY OWNER
FURR OUT WALL WITH 3/4" GYP. BD ON METAL HAT CHANNELS
PROVIDE RESILIENT PLANK FLOORING
BANQUETTE SEATING WITH CHAIRS AND 24x60 TABLE (BY OWNER)
SEE ELEVATION 4/A1.1 FOR TV. WALL RECESS DIMENSIONS
LINE DEFINES GENERAL AREA OF WORK. ADDITIONAL WORK OR
INTERACTION WITH ADJACENT AREAS OUTSIDE BOUNDARY MAY
BE REQUIRED. LINE SHOULD NOT BE USED AS A CONSTRUCTION
SCOPE BOUNDARY.
PROVIDE 1 HR FIRE SEPARATION WALL ASSEMBLY. AT NEW WALL
CONSTRUCTION, RETURN SEPARATION TO EXISTING CONSTRUCTION AS
REQUIRED TO MAINTAIN CONTINUITY OF 1HR SEPARATION
1
2
ARCHITECTURAL FLOOR PLAN
SCALE: 1/8"=1'-0"
N
LOCATOR PLAN
NOT TO SCALE
N
PROJECT AREA
GENERAL FLOOR PLAN NOTES CON'T:
PARTIALL FLOOR PLAN
SCALE: 1/4"=1'-0"
1
1
2
3
3
4
4
5
5
66
66
7
7
8
8
8
9
9
9
10
10
11
11
7
7
7
4
-
1
2
A-6.1
6
A-6.1
5
A-6.1
128.1A
1B
CORRIDOR
128.1
128.1B
128.1G
EXIST
128.1H
BREAK
ROOM
128
VENDING
122.0
CORRIDOR
EXIST
128A
CORRIDOR
128.1
CORRIDOR
128.1
CORRIDOR
128.1
VENDING
122.0
BREAK
ROOM
128
1
A-1.1
1
A-1.1
1B 1B
2B
2B
3
1A
1A
3
12
1212
128.1C
128.1D
128.1E
128.1F
2
A-6.1
3
A-6.1
EXIST
13
14
14
10
11
15
15
1
3
1
3
3
3
3
11"
11
"
STEEL RUNNER FASTENED
TO STRUCTURE ABOVE
5/8" GYP. BOARD - EXTEND 8"
ABOVE ACOUSTIC CEILING TILE
ACOUSTIC CEILING TILE AND
TEE
REFER TO RCP
CORNER REINFORCEMENT
MIN. 3 5/8" STEEL STUD @
24" O.C.
RE
FE
R T
O R
CP
FO
R H
EIG
HT
A
.F
.F
.
PROVIDE DIAGONAL
BRACING 48" OC MAX.
8"; T
YP
S
S
S
1. SWITCH SYMBOL INDICATES THE LOCATION FOR SWITCHING ALL FIXTURES WITHIN THAT
ROOM UNLESS NOTED OTHERWISE. REFER TO ELECTRICAL DRAWINGS FOR FURTHER
INFORMATION AS REQUIRED.
2. CONTRACTOR TO CENTER ALL CEILING MOUNTED ITEMS (i.e.. RECESSED LIGHT FIXTURES,
SMOKE DETECTORS, FIRE SUPPRESSION HEADS) WITHIN THE ASSOCIATED CEILING TILE
AS SHOWN. COORDINATE FINAL LOCATION WITH THE APPROPRIATE MECHANICAL,
ELECTRICAL, FIRE ALARM, AND FIRE SUPPRESSION DRAWINGS AS REQUIRED.
3. REFER TO WALL TYPES FOR WALLS THAT PENETRATE CEILINGS.
4. REFER TO MECHANICAL HVAC PLANS FOR DIFFUSER / GRILLE SIZES.
5. FOR LIGHT FIXTURE TYPES SEE ELECTRICAL LIGHTING PLANS.
6. REFER TO DIMENSIONS ON REFLECTED CEILING PLAN TO LOCATE / LAYOUT CEILING GRID
AND LIGHT FIXTURES.
7. ACCESS PANELS TO BE INDEPENDENTLY MOUNTED, DO NOT SUPPORT ON CEILING GRID.
COORDINATE SIZE, QUANTITY AND LOCATIONS WITH ARCHITECTURAL AND MECHANICAL
DRAWINGS.
GENERAL REFLECTED CEILING PLAN NOTES:
REFLECTED CEILING PLAN KEY NOTES:
(TYPICAL THIS SHEET ONLY)
EXIST. CEILING TO REMAIN
NEW 2X2 GRID, REWORK EXIST. HVAC SUPPLY AND DIFFUSERS VIF EXISTING LOCATIONS,
CEILING HEIGHT TO REMAIN CONSISTENT AFF AS FINISH FLOOR HEIGHT VARIES.
NEW 2X4 LED FIXTURE BY LITHONIA
NEW 1X4 LED FIXTURE BY LITHONIA IN EXISTING CEILING GRID, REPAIR DAMAGED TILES
AS REQ'D.
6" CAN LIGHTS,
NEW LINEAR DIFFUSERS
NEW PENDANT LIGHTS OVER NEW ISLAND
NOT USED
NEW SURFACE MOUNTED LED LIGHTS
REPAINT CEILING,ACCESS PANELS AND DIFFUSERS/AIR RETURNS TO MATCH EXISTING
ADJACENT
LINE DEFINES GENERAL AREA OF WORK. ADDITIONAL WORK OR INTERACTION WITH
ADJACENT AREAS OUTSIDE BOUNDARY MAY BE REQUIRED. LINE SHOULD NOT BE USED
AS A CONSTRUCTION SCOPE BOUNDARY.
NEW GYPSUM BOARD SOFFIT TO BE PAINTED (PT-5)
A
B
ACOUSTIC CEILING TILE SYSTEM PER
SPECIFICATION
1'X4' LED LIGHT FIXTURE
2'X4' LED LIGHT FIXTURE
2'X2 'LED LIGHT FIXTURE
2'X4' LED NIGHT LIGHT FIXTURE, SEE
ELECTRICAL
SUPPLY AIR DIFFUSER
RETURN AIR GRILL
GYPSUM BOARD CEILING AND/OR SOFFIT
RECESSED DOWNLIGHT FIXTURE
EMERGENCY LIGHT FIXTURE W/ BATTERY
SUPPLY
ELEVATION ABOVE FINISHED FLOOR
SMOKE DETECTOR
WALL WASHING LIGHT FIXTURE
UNDER CABINET LIGHT FIXTURE
WALL SWITCH
FIRE SUPPRESSION HEAD
SPEAKER
S
2'X4' LEDLIGHT FIXTURE WITH 'XX' CELL,
DEEP-CELL PARABOLIC DIFFUSER
2'X4' LED DIRECT/INDIRECT LIGHT FIXTURE
S
EXIT LIGHT (SHADING INDICATES LIGHTED
FACE)
REFLECTED CEILING LEGEND
DESCRIPTIONSYMBOL
SWALL SCONCE FIXTURE
EXISTING FIXTURE TO REMAINE
EXISTING FIXTURE TO BE RELOCATEDR
DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL
EXHAUST AIR GRILL
HEIGHT
REFLECTED CEILING PLAN
SCALE: 1/4"=1'-0"
N
8'-4"
8'-0"
9-6"
ETR
ETR
8'-6"
ETR
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
C
CCCC
C
C
C
C
C
C
C
C
D
D
D
D
D
D
D
D
D
D
D
B
E
E
TYP.
E
TYP.
F
F
F
G
G
H
7'-8"
9-6"
8'-0"
7'-4"
7'-4"
ETR
ETR
8'-4"
BRACED SOFFIT DETAILX
TYP.
SCALE: 1 1/2"=1'-0"
2ND FLOOR CELING PLAN
SCALE: 1/8"=1'-0"
N
J
J
J
J
J
K
K
L
L
L
M
M
M
M
M
C
C
C
A
B
3
3
3
2"
1'-8" 3'-4"
2'-1
0"
3'-6
"
9"
4"
BASE AS SCHEDULED
GYP. BOARD SOFFIT
COUNTERTOP AND
BACK SPLASH
P.LAM FILLER PANEL
WALL BASE ON TOE
KICK AS SCHEDULED
P.LAM BASE CABINETS
1
A7.1
OPEN TO
BEYOND
1'-6
"
3'-6
"
BASE AS SCHEDULED
BANQUET BOOTH
SEATING BY OTHERS
GYP. BOARD SOFFIT
3'-0
"4
'-4
"
4'-4"
PROVIDE 4" GYP. BD.
RECESS FOR TV.
(TV BY OWNER)
OPEN TO
BEYOND
OPEN TO
BEYOND
OPEN TO
BEYOND
BASE AS SCHEDULED
GYP. BOARD SOFFIT
2" FRAME, TYP.
TOP AND BOTTOM
BUTT GLAZED JOINT
PROVIDE 1/4" CLEAR
SILICONE SEALANT AT
JOINT, TYP.
1/2" SINGLE PANE
CLEAR GLASS. TYP.
PROVIDE POLISHED
BEVELED MTL
EDGE,TYP.
WALL BEYOND
12'-10"± VIF
4 EQUAL PANELS
1'-4"
4"
2'-1
0"
2'-4"3'-0"3'-2 1/2" 1'-5"1'-5" 1'-5" 1'-5"
2'-1
0"
1'-8"
2'-9
1
/2
"
1"
1 1/2"
WALL BASE ON TOE
KICK AS SCHEDULED
GYP. BOARD SOFFIT
COUNTERTOP AND
BACK SPLASH
FULL HEIGHT WALL
TILE
P.LAM BASE
CABINETS
P.LAM MICROWAVE
SHELVES
P.LAM FILLER
PANEL
1
A7.1
2
A7.1
3
A7.1
VENDING MACHINE
BY OWNER
PROVIDE NEW
ELECTRICAL
OUTLET FOR
EACH MACH.
TYP.
REFRIGERATOR
BY OWNER
ELECTRICAL OUTLET,
TYP.
3'-6
"
BRUSHED STAINLESS
STEEL SUPPORT
BRACKET
GYP. BOARD SOFFIT
BARTOP
PENDANT LIGHT
FIXTURES
4
A7.1
OPEN TO
BEYOND
OPEN TO
BEYOND
OPEN TO
BEYOND
BASE AS SCHEDULED
GYP. BOARD SOFFIT
3'-6
"7
'-8
"
1/2" SINGLE PANE
CLEAR GLASS. TYP.
PROVIDE POLISHED
BEVELED MTL
EDGE,TYP.
2" FRAME, TYP.
TOP AND BOTTOM
BUTT GLAZED JOINT
PROVIDE 1/4" CLEAR
SILICONE SEALANT AT
JOINT, TYP.
12'-3 1/2"± VIF
4 EQUAL PANELS
INTERIOR ELEVATION1
A1.1
SCALE: 1/4" = 1'-0" #128 BREAK ROOM / # 128.1 CORRIDOR
INTERIOR ELEVATION2
A1.1
SCALE: 1/4" = 1'-0" #122.0 VENDING / #128 BREAK ROOM
INTERIOR ELEVATION3
A1.1
SCALE: 1/4" = 1'-0" #128 BREAK ROOM
INTERIOR ELEVATION4
A1.1
SCALE: 1/4" = 1'-0" #128 BREAK ROOM
INTERIOR ELEVATION5
A1.1
SCALE: 1/4" = 1'-0" # 128.1 CORRIDOR
INTERIOR ELEVATION6
A1.1
SCALE: 1/4" = 1'-0" # 128.1 CORRIDOR
3
3
3
3
3
'
-
5
"
2'-6
1
/2
"
2'-6 1/2"
6"
3'-3"
3'-3
"
6"
6"
2'-6"
3
'-
5
"
2'-6
1
/2
"
2'-6 1/2"
6"
3'-3"
3'-3
"
6"
6"
2'-6"
RF-3 (*RB-1)
LVT-1 (*RB-1)
RF-1 (*RB-1)
RF-2 (*RB-1)
FINISH FLOOR PLAN
SCALE: 1/4"=1'-0"
N
FLOOR PLAN KEY NOTES:
(TYPICAL THIS SHEET ONLY)
NEW MOSAIC WALL TILE INSTALLED FULL HEIGHT (WT-1); REFER TO INTERIOR
ELEVATIONS FOR LOCATIONS AND DESIGN.
NEW ACCENT PAINT ON WALL (PT-2)
NEW QUARTZ COUNTERTOP (QZ-1) AND P.LAM CABINETS (PL-1); REFER TO INTERIOR
ELEVATIONS FOR LOCATIONS AND DESIGN.
NEW QUARTZ BARTOP (QZ-1) AND STAINLESS STEEL SUPPORT LEGS; REFER TO INTERIOR
ELEVATIONS FOR LOCATIONS AND DESIGN.
NEW PAINT ON WALLS (PT-1)
NEW PAINT ON EXISTING H.M. FRAMES (PT-3)
TOUCH UP PAINT ON EXISTING ELEVATOR DOORS AS NEEDED (PT-4)
EXISTING WALL AND BASE FINISH TO REMAIN
NEW TRANSITION STRIP; CONTRACTOR TO VERIFY FLOORING TRANSITION IN FIELD AND
SELECT FROM TRANSITIONS PROVIDED IN LIST OF MATERIALS.
NEW PAINT ON EXISTING H.M. DOOR AND FRAME (PT-3)
1
2
FLOOR PATTERN LEGEND
(TYPICAL THIS SHEET ONLY)
(* DENOTES WALL BASE USED)
1
GENERAL NOTES:
(TYPICAL THIS SHEET ONLY)
1. REFER TO MATERIAL / FINISH SCHEDULE FOR SPECIFIC FINISH TYPES.
2. CONTACT ARCHITECT SHOULD ANY FINISH DISCREPANCIES OCCUR.
3. THIS SHEET IS INTENDED TO BE PRINTED IN COLOR TO CONVEY NECESSARY DESIGN
INFORMATION.
4. PATCH ALL HOLES, ETC. LEFT BY ALL TRADES (INCLUDING ELECTRICAL AND
MECHANICAL) PRIOR TO PAINTING. PAINT WALL(S) OR CEILING(S) NOT SCHEDULED TO
BE PAINTED, WHICH HAVE HAD PATCHING, FROM INSIDE CORNER TO INSIDE CORNER
ACROSS ENTIRE SURFACE.
5. FLOORING CONTRACTOR SHALL INCLUDE FLOOR PREPARATION IN THEIR BASE BID
SCOPE OF WORK. ANTICIPATE AN APPLICATION OF FLOOR STONE OVER THE ENTIRE
SURFACE TO BRING LIKE-PRODUCTS TO A LEVEL CONDITION THAT MEETS OR
EXCEEDS THE SUBFLOOR TOLERANCES ESTABLISHED BY PRODUCT MANUFACTURER.
WHERE MATERIAL IS TO BE INSTALLED AT SLAB ON GRADE CONDITIONS, MOISTURE
TESTS SHALL BE CONDUCTED OF THE EXISTING SLAB TO ENSURE THE SUBFLOOR
MEETS PRODUCT REQUIREMENTS. AT FLOOR TILE INSTALLATIONS, THE MOVEMENT
GUIDELINES ESTABLISHED IN EJ171-05 SHALL BE FOLLOWED, INCLUDING THE USE OF
BOND BREAKER TAPES AS RECOMMENDED.
6. REFER TO FLOOR PATTERN LEGEND FOR FLOOR MATERIAL UNLESS NOTED ON PLAN.
7. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS AND CEILING FINISHES.
FINISH KEY
PULLS
MANUFACTURER: RICHELIEU
STYLE: CLASSIC METAL HANDLE PULL - 6500
PRODUCT NUMBER: BP650020128195
FINISH: BRUSHED NICKEL - 195
LOCATION: BASE CABINETS, DRAWERS
QUARTZ SURFACE
MANUFACTURER: CAMBRIA
STYLE/COLOR: TEMPLETON
LOCATION: SEE FINISH FLOOR PLAN FOR EXACT LOCATION
CONTACT: GEORGE PAPALEXIS 231.769.5821
06410 - ARCHITECTURAL CASEWORK
06415 - COUNTERTOPS
WALL TILE
MANUFACTURER: GENESEE TILE / STONE PEAK
STYLE: QUARTZITE
COLOR: IRON
SIZE: NEW MOSAIC DESIGN 4 12X24
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
CONTACT: ERIN CHESLEY 810.459.0229
GROUT: LATICRETE PERMACOLOR GROUT
COLOR: 45 RAVEN
THICKNESS: 1/8"
09300 - CERAMIC TILE, GLASS MOSAIC, ETC.
15000 - ELECTRICAL
FACE PLATES
COLOR: BRUSHED STAINLESS STEEL
DEVICES
COLOR: BLACK
WT-1
QZ-1
-
09650 - RESILIENT FLOORING
RUBBER BASE
MANUFACTURER: NORA
COLOR: 6294 STONE GREY
SIZE: 4"
PROFILE: STRAIGHT
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
RUBBER FLOORING
MANUFACTURER: NORA
STYLE: SENTICA
COLOR: 6521 SUNDAY PAPER
THICKNESS: 2.0MM
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
RF-1
RB-1
RF-2RUBBER FLOORING
MANUFACTURER: NORA
STYLE: SENTICA
COLOR: 6523 ROAD TRIP
THICKNESS: 2.0MM
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
RF-3RUBBER FLOORING
MANUFACTURER: NORA
STYLE: SENTICA
COLOR: 6522 EXPEDITION
THICKNESS: 2.0MM
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
TS-1
TS-2
TS-2
TS-3
TS-3
TS-3
TS-3
TS-3
TS-2
TS-2 TS-1
TS-1
TS-1
TS-1
RUBBER STAIR TREADS
MANUFACTURER: NORA
COLOR: 0749 STONE GREY
STYLE: NORAMENT 920 ROUND STAIRTREAD W/
INTEGRATED RISER
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
STR-1
09511 - SUSPENDED ACOUSTICAL CEILING
CEILING TILE
MANUFACTURER: ARMSTRONG
STYLE: ULTIMA 1901
COLOR: WHITE
SIZE: 24X24
EDGE: TEGULAR
GRID PROFILE: 15/16"
ACT-1
TS-1RUBBER TRANSITION STRIP
MANUFACTURER: JOHNSONITE
STYLE: SLT-63-C (SLIM LINE TRANSITIONS)
COLOR: 63 BURNT UMBER
TRANSITION: 1/4" TO 0.80"
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
NOTES: USE SLTC-63-C WHERE NEEDED
INTERIOR FIELD PAINT
MANUFACTURER: SHERWIN WILLIAMS
COLOR: TO MATCH BENJAMIN MOORE FOSSIL/ AF65
FINISH: EGGSHELL
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
09910 - PAINT
INTERIOR ACCENT PAINT
MANUFACTURER: SHERWIN WILLIAMS
COLOR: SW7616 BREEZY
FINISH: EGGSHELL
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
DOOR AND FRAME PAINT
MANUFACTURER: SHERWIN WILLIAMS
COLOR: SW7048 URBANE BRONZE
FINISH: SEMI-GLOSS
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
PT-3
PT-2
PT-1
09650 - RESILIENT FLOORING
LOCATOR PLAN
NOT TO SCALE
N
PROJECT AREA
TS-2
3
4
3
3
4
5
5
5
5
5
5
6
7
7
7
6
6
6
6
6
6
10
10
6
6
6
6
ELEVATOR DOOR AND FRAME PAINT
MANUFACTURER: SHERWIN WILLIAMS
COLOR: TO MATCH EXISTING
FINISH: TO MATCH EXISTING
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
PT-4
SOFFIT PAINT
MANUFACTURER: SHERWIN WILLIAMS
COLOR: SW7695 MESA TAN
FINISH: EGGSHELL
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
PT-5
VINYL PLANK
MANUFACTURER: PATCRAFT
STYLE: NORTHRIDGE/ WOOD PLANK
COLOR: SPICED TEA 02544
PLANK WIDTH: 4"
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
LVT-1
TS-2RUBBER TRANSITION STRIP
MANUFACTURER: JOHNSONITE
STYLE: SLT-63-B (SLIM LINE TRANSITIONS)
COLOR: 63 BURNT UMBER
TRANSITION: 1/8" TO 0.80"
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
8
8
8
8
8
TS-3RUBBER TRANSITION STRIP
MANUFACTURER: JOHNSONITE
STYLE: SLT-63-J (SLIM LINE TRANSITIONS)
COLOR: 63 BURNT UMBER
TRANSITION: 0.80" TO SUBFLOOR
LOCATION: SEE FINISH PLAN FOR EXACT LOCATION
9
9
9
2
10
3
3
1