06 02 03 tcb tcd - TRANSCON
Transcript of 06 02 03 tcb tcd - TRANSCON
© 2
011 TRAN
SCO
N E
LECTRO
NIC
SYSTEM
S, s.
r.o., A
ll rights
rese
rved
[email protected] www.transcon.euverze: [email protected] www.transcon.euverze: 21092011
4
10
2
3
11
8
5
7
6
9
13
16
14
17 19
6.2TCB
1
15
20
4
2
10 3
11
12857
689
1316
14
17
1
18 19
2
ORDERING CODES: TCB.2. x x x
Type series of container Thermal insulation N = normal thermal insulation (-30/+35 °C)A = arctic (-55/+35 °C, PUR 80 mm thick container insulation, heating of entrance door doorframe)T = tropic (-10/+55 °C)ExecutionS = stationary (cable ducts in the floor)M = mobile execution (cable ducts through connectors in cable pockets) Voltage system 2 = 3 x 220 V / 50-60 Hz4 = 3 x 230/400 V / 50-60 Hz0 = other voltage system, must be specified
CONTAINER PROGRAMpage: 1 / 1
chapter:
AApplication
! container "briefing" for mobile airport set ~ 4 500 kglength width height6058 x 2438 x 2591
1. doors 2. windows3. air condition4. sofa5. satellite tv6. radio7. video8. library9. stand with drinking water10. computer11. telephone12. el. heating13. cooker14. refrigerator15. kitchenette16. kitchen sink17. microwave oven18. toilet19. wardrobe
TCB - STANDARD TCB.2.NM4
Profile of entrance door 900x1995 mm
Footing under the container no
Double floor no
Lighting fluorescent
Emergency lighting yes
Obstruction lights no
Air condition yes
Heating yes
Open door alarm no
Monitoring of container internal temperature no
© 2
011 TRAN
SCO
N E
LECTRO
NIC
SYSTEM
S, s.
r.o., A
ll rights
rese
rved
[email protected] www.transcon.euverze: [email protected] www.transcon.euverze: 21092011
TCD6.3
2
3
4
79
8
6
TCD.2.X.D300
TCD.2.X. D175+50
1
1
2
2
3
5
6
6
7
8
9
9
48
54
6
8
8
4
1
10
10
ORDERING CODES: TCD.2 . x x x x . x
Type series of containerThermal insulationN = normal thermal insulation (-30/+35 °C)A = arktic (-55/+35 °C, PUR 80 mm thick container insulation, heating of entrance door doorframe, diesel generating set oil heating, ether start of diesel generating set T = tropic (-10/+55 °C)
ExecutionS = stationary (cable ducts in the floor)M = mobile execution (cable ducts through connectors in cable pockets) Voltage system2 = voltage system 3 x 220 V4 = voltage system 3 x 230/400 V0 = other voltage system, must be specified Frequency5 = mains frequency 50 Hz 6 = mains frequency 60 HzOutputD150 = diesel generator set output 150 kVAD200 = diesel generator set output 200 kVAD250 = diesel generator set output 250 kVA D300 = diesel generator set output 300 kVAD175+50 = pair of independent diesel generator sets 175 kVA and 50 kVA
CONTAINER PROGRAM page: 1 / 1
chapter:
AApplication
! container with diesel generator set
~ 7 500 kglength width height6058 x 2438 x 2591
1. doors 2. airholes3. refuelling 4. diesel generator set 175 kVA5. diesel generator set 50 kVA
6. distributor box 7. tank8. control panel 9. exhaust pipe10. heating
TCD - STANDARD TCD.2.NS45.D250
Profile of entrance door 900x1995 mmFooting under the container yes
Double floor no
Lighting yes
Emergency lighting yes
Obstruction lights no
Air condition no
Heating yes
Open door alarm yes
Monitoring of container internal temperature no
Self-consumption switchboard yes
Diesel generating set – max. output 300 kVA (D300)
Diesel generating set protection accord. to the output