050-R40 Series .050 [1.27] Center, .400 [10.16] Stroke
August 16, 2012
QA is pleased to announce the addition of our 050-R40 Series, .400 [10.16] stroke .050 [1.27]center long stroke probe for dual-level testing on 50mil centers. These long-stroke probes areeasily mixed with their standard-stroke counterparts from the 050-R25 series. Long-stroke andstandard-stroke probes with the same center spacing are used in identical sockets.
Point Styles
All dimensions are in inches [mm]. All spring forces are in ounces [gms].
8R- ~ Razor
Probe SpecificationsFull Stroke: .400 [10.16] Working Stroke: up to .317 [8.05]Operating Temp: -50° to 250°F [-45° to 120°C]Average Resistance: < 40 mOhms Current Rating: 9.5 Amps
6R- ~ Razor
Tube Letter Material/Finish
P Nickel silver / ID precious metal clad
Poin
t Digit Material/FinishSee
PointsStandard material is heat treated BeCu / plated gold over nickel(see S option for steel plungers)
Sprin
g Letter Preload@ .317Stroke
MaterialMechanical Life
(cycles @ stroke)
X 1.5 [43] 6.0 [170] Stainless Steel 250K min @.317 [8.05] max
Opt
ion
Letter Description
DDecreased stroke is .250 [6.35]. Must select from 050-R25 series spring forces with this option.
NNo probe lubrication. Removing probe lubrication greatly reduces cycle life and should be only used in applications outside of the probe operating temperature specifications.
S Heat treated steel / plated gold over nickel
Part Number: 050-PRP40 X -
46 - Flat Star
76 - Center Point Star
Spring Force
Probe
0
57
113
170
227
283
0.00 2.54 5.08 7.62 10.16
0.0
2.0
4.0
6.0
8.0
10.0
12.0
0.000 0.050 0.100 0.150 0.200 0.250 0.300 0.350 0.400
Fo
rce
(Gra
ms)
Plunger Stroke (Millimeters)
Fo
rce
(Ou
nce
s)
Plunger Stroke (Inches)
X
.317(8.05)Stroke
As shown to the right, the long-stroke probe tips are .150 [3.81]higher than neighboring standard-stroke tips when the fixture is notactuated. In the functional test position, the long-stroke probes are deflected .060 [1.524], leaving.090 [2.29] clearance to the tips ofthe standard-stroke probes. Duringin-circuit test, deflection of thelong-stroke probes is .317 [8.05],and the standard-stroke probes aredeflected .167 [4.24] (the recom-mended two-thirds travel position).
Fixture Not Actuated
.150 Tip Height
Difference
.250
Stro
ke P
robe
.400
Stro
ke P
robe
Functional Test Position
.060 Stroke
.090 Gap
Unit Under Test
.250
Stro
ke P
robe
.400
Stro
ke P
robe
In-Circuit Test Position
Operational Position
@ .317Stroke
@ .167Stroke
.250
Stro
ke P
robe
.400
Stro
ke P
robe
Unit Under Test
Unit Under Test
.015 .015.015
The illustration above shows the typical positions of both a standard.250 stroke and .400 long-stroke 050-R40 in dual level testing. Toachieve the .150 tip height difference, set the socket .015 lower onthe the .400 stroke.
Sockets