05 HLR System Structure(CDMA)
-
Upload
rajendrablr -
Category
Documents
-
view
230 -
download
0
Transcript of 05 HLR System Structure(CDMA)
-
7/27/2019 05 HLR System Structure(CDMA)
1/48
-
7/27/2019 05 HLR System Structure(CDMA)
2/48
System Architecture of
the HLR/AUC
-
7/27/2019 05 HLR System Structure(CDMA)
3/48
Agenda
Overall system structure
CPM HSM
HDM
OMM
The Agent system
-
7/27/2019 05 HLR System Structure(CDMA)
4/48
Public Land Mobile Network (PLMN)
EIRMSCMS
BTS PSTNBSC MSC
MC MC HLR VLR
AUCSMESME
PSTN
OMC
Abis A
E
F
Ai
Q C B
M C D
M
M N
Um
Summary of HLR/AUC
-
7/27/2019 05 HLR System Structure(CDMA)
5/48
Home Location RegisterHLRHLR is a central database, it stores the subscribers data and incharge of the management of mobile subscriber.
functions of HLR:
1) Storage of data
Basic service information ESN,MIN/IMSI, MDN and so on.
Supplementary service information
Service limitation
Current Location information of ms
VLR address, MSC address,etc.
And so on
-
7/27/2019 05 HLR System Structure(CDMA)
6/48
-
7/27/2019 05 HLR System Structure(CDMA)
7/48
-
7/27/2019 05 HLR System Structure(CDMA)
8/48
ZXC10-HLR/AUC performs external signaling switching withother functional entities via signaling No. 7.Internally, it adopts
Ethernet connection mode, and communicates via TCP/IP.
HLR/AUC serves as central data processing center in CDMAmobile communication system, implements the subscriber
service processing and subscriber data management, and
performs the signaling switching, system maintenance and
service handling with other functional entities via signaling
No. 7 .
ZXC10-HLR/AUC STRUCTURE
-
7/27/2019 05 HLR System Structure(CDMA)
9/48
HARDWARE STRUCTURE
-
7/27/2019 05 HLR System Structure(CDMA)
10/48
1 Common Channel Signaling handling subsystem(CPM)
2 Service processing subsystem(HSM)
3 Database subsystem(HDM)
3 Operation and Maintenance subsystem(OMM)
HLR/AUC consists of four parts:
Various sub-systems are connected via the high-speed Ethernet
and communicate through TCP/IP.
HARDWARE STRUCTURE
-
7/27/2019 05 HLR System Structure(CDMA)
11/48
SOFTWARE STRUCTURE
Software consists of five parts:Operation support subsystem
Signaling processing subsystem
Database subsystem
Service processing subsystem
Operation & maintenance subsystem
-
7/27/2019 05 HLR System Structure(CDMA)
12/48
Operating support subsystem
Operation&
mainte
nancesubsystem
Databasesubsystem
Service processing subsystem
Signaling processing subsystem
SOFTWARE STRUCTURE
-
7/27/2019 05 HLR System Structure(CDMA)
13/48
Agenda
Overall system structure
CPM HSM
HDM
OMM
Service Agent
-
7/27/2019 05 HLR System Structure(CDMA)
14/48
CPM mainly performs the SS7 handling function.it realize the
reception and sending of SS7 between HLR and PLMN.
acts as an interface between HLR/AUC and other function
entities,implementing mtp,sccp,tcap functions.
exchange the messages with HSM.
CPM(CCS handling module)
H d t t f CPM
-
7/27/2019 05 HLR System Structure(CDMA)
15/48
CPM has the same hardware platform as MPM,but the switching
unit is different. The capability is 4K x 4K .
Hardware structure of CPM
DTI
No.7
COMM COMM
MP0 MP1
TNET 4K 4K synchronous switching
network
8Mbit/s
2Mbit/s
-
7/27/2019 05 HLR System Structure(CDMA)
16/48
Each CPM can insert 2 STB board at most,each STB provide 16
links.so each CPM only provide 32 links at most.
BCTN
Rack single board array diagram
-
7/27/2019 05 HLR System Structure(CDMA)
17/48
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
PW
R
B
SM
E
M
MP
MP
CO
M
M
1
CO
M
M
2
CO
M
M
3
CO
M
M
4
CO
M
M
5
CO
M
M
6
PE
P
D
MO
N
TN
E
T
TN
E
T
DT
DT
DT
DT
DT
PW
R
B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
B
C
T
N
6
Rack single board array diagram
-
7/27/2019 05 HLR System Structure(CDMA)
18/48
Hardware structure of CPM
COMM1/2: inter-modual communication(MPMP)
COMM3/4: intra-modual communication(MPPP)
COMM5/6: STB
TNET: 32 HW 8Mb/s
HW0-HW3: for message
HW7-HW11:for DTI(slot 22-26)HW30-HW31:for selfloop
DTI board: slot 22-26,20 E1 interface
-
7/27/2019 05 HLR System Structure(CDMA)
19/48
CCS software package
CPM component
TCP/IP communication module
TCAP
module
SCCP
module
MTP
module
Message distribute module (MD)
HSMcomponent
PLMN
software structure of CPM
-
7/27/2019 05 HLR System Structure(CDMA)
20/48
1. The CPM component composed of a single SS7 front-end processor
can provide 32 SS7 links to meet requirements of 200 thousand subscriber
2. With the increase of subscribers, more SS7 front-end processors shouldbe configured. In this networking mode, one SS7 front-end processor serv
as the core, supporting 1~5 SS7 front-end processors.
Center CPM
CPM5CPM2CPM1...
2E1 2E12E1
-
7/27/2019 05 HLR System Structure(CDMA)
21/48
Agenda
Overall system structure
CPMHSM
HDM
OMM
Service Agent
-
7/27/2019 05 HLR System Structure(CDMA)
22/48
HSM( i i d l )
-
7/27/2019 05 HLR System Structure(CDMA)
23/48
Working mode:
HSM adopts the multi-module load-sharing mode.
It consists of one or multiple service processing modules
(HSM). Multiple HSMs can work in parallel to carry outservice processing tasks, and can form redundant backup
for one another.
the link monitoring functions are set between the CPM
subsystem and the service processor. when any HSM breaksdown, other HSMs will share its load evenly.
HSM(service processing module)
HSM( i i d l )
-
7/27/2019 05 HLR System Structure(CDMA)
24/48
Processing capability:
Each service processor can handle 120 thousands subscribers.
we can smoothly expand the service processor to enhance the HLR service
processing capacity. Each time a service processor is added, the CPM components
will be automatically monitored, without affecting the normal running.
To ensure the reliability and processing capability of the system, the serviceprocessoradopts N+1 redundancy configuration and load sharing mode.
In fact,we set two HSM at least.
Node assignment:
Service processor node140~149 ,240--249
HSM(service processing module)
HSM( i i d l )
-
7/27/2019 05 HLR System Structure(CDMA)
25/48
HSM rack diagram
HSM(service processing module)
-
7/27/2019 05 HLR System Structure(CDMA)
26/48
Agenda
Overall system structure
CPM HSM
HDM
OMM
Service Agent
HDM (D t b d l )
-
7/27/2019 05 HLR System Structure(CDMA)
27/48
Content :
Database component
Subscriber basic information
Supplementary services data
Intelligent service data
Security data
Subscriber area subscription data
HDM (Database module)
HDM (D t b d l )
-
7/27/2019 05 HLR System Structure(CDMA)
28/48
Structure :
Each HDM includes 2 hosts(sever1 and sever2)and 1shared disk chassis.
Each host contains one SCSI adaptive card, three
Ethernet cards (1, 2),.
The disk chassis provides two SCSI interfaces.
. The two hosts are interconnected via the Ethernet card 1
to form a heartbeat line. It can monitor the working status of
the opposite side at any time.
HDM (Database module)
HDM (Database mod le)
-
7/27/2019 05 HLR System Structure(CDMA)
29/48
HDM (Database module)
Crossover cable
Ethernet card 1
Ethernet card 2
Disk array
adapter
Disk array
adapter
Ethernet card3Ethernet card 2
Server 1 Server 2
Disk chassis
To HUB1 To HUB2 To HUB1 To HUB2
Ethernet card 3
Ethernet card 1
HDM (Database module)
-
7/27/2019 05 HLR System Structure(CDMA)
30/48
IP address assignment:
Both servers of the HDM have their respective
machine names and IP address,providing externally
the same virtual machine name and IP address.and
serving externally in such capacity.
HDM (Database module)
HDM (Database module)
-
7/27/2019 05 HLR System Structure(CDMA)
31/48
Working mode:
Different HDM adopt distributed in storage in multiple
nodes and work in the load-sharing mode.
these two host of one node work in active/standby mode.
Storage capability:
Each node of HDM can store 500,000 subscriberss data.
.
HDM (Database module)
HDM (Database module)
-
7/27/2019 05 HLR System Structure(CDMA)
32/48
Operating system:
system supports multiple operationsystems (e.g., Windows
NT, UNIX etc). Databases can employ large-scale
commercial database systems such as Oracle, Sybase, andMicrosoft SQL Server etc.
It is highly recommended that the Windows NT operation
system and Microsoft SQL Server database be chosen.
HDM (Database module)
HDM (Database module)
-
7/27/2019 05 HLR System Structure(CDMA)
33/48
Adopts the cluster group technology and shared disk array
mode .
Disks storing data are all in the synchronous mirror mode.
When any disk is physically damaged, the whole system can
continue running normally, not affected in any way.
Data are daily backed up to the local disks or magneticmachine. Once the data break down, the system can quickly
restore the backup data of the previous day.
reliability and security of the database system is even more
important. This has to be guaranteed in technical approaches.
HDM (Database module)
HDM (Database module)
-
7/27/2019 05 HLR System Structure(CDMA)
34/48
HDM rack diagram
HDM (Database module)
HDM (Database module)
-
7/27/2019 05 HLR System Structure(CDMA)
35/48
HLR/AUC database includes the user database on the database
component, and the system management database on OMM
Server.
System management database:
stores various types of basic data necessary for the running of
the system, such as system structure configuration, system security
information, system running, operator account authority, etc.User database:
storing the opening-account information of subscriber,
subscriber services information and authentication information,
Classification of database
HDM (Database module)
HLR/AUC STRUCTURE
-
7/27/2019 05 HLR System Structure(CDMA)
36/48
Service processor 2
Service processor n
Service processor 1
Reception station 2
Reception station n
Reception station 1
Maintenance
station
System managementdatabase
Mobile subscriber
database
Mobile subscriber
database
...
Reception s tation service module
System maintenance
service module
Operation & maintenance server
HLR/AUC STRUCTURE
-
7/27/2019 05 HLR System Structure(CDMA)
37/48
Agenda
Overall system structure
CPM HSM
HDM
OMM
Service Agent
OMM (O & M module)
-
7/27/2019 05 HLR System Structure(CDMA)
38/48
O
M
MClient terminal subsystem
Sever subsystem
Service agent subsystem
OMM is used to manage HLR/AUC, mainly including the
authority management, data configuration, security
management, performance statistics, fault management,diagnosis & test, signaling tracing, version management, file
management, traffic observation, clock management and
database management.
OMM (O & M module)
OMM (O & M module)
-
7/27/2019 05 HLR System Structure(CDMA)
39/48
Server
(Windows NT server)
Client
(Windows NT client)
. . . . .Client
(Windows NT client)
background
CPM
component
service
handlingcomponent
database
component
Service agent
Foreground
OMM (O & M module)
-
7/27/2019 05 HLR System Structure(CDMA)
40/48
Agenda
Overall system structure
CPM HSM
HDM
OMM
The Agent system
The agent system
-
7/27/2019 05 HLR System Structure(CDMA)
41/48
The agent system
Omm partsomm
serverserviceAgent
Local
ommCPM
Service
Processing
parts
Data base
partsrouter
DDN/FR/X.25/PSTN
Remote
Omm console
Remote
service AgentNetwork
Management
center
The agent system
-
7/27/2019 05 HLR System Structure(CDMA)
42/48
System architecture of service agent
The agent system
-
7/27/2019 05 HLR System Structure(CDMA)
43/48
The DBIO module in OMM manages the requests
from the agent and maintenance console, running the user
data in database node group in C/S mode, and returning
the operation results to the agent and maintenance console.
The successful operations are recorded in user log.
Access mode of service agent
-
7/27/2019 05 HLR System Structure(CDMA)
44/48
HLR/AUCDB
140129 server
204 203 205
Remote service agent
The agent can be located either at the near end, or at the far end,
realizing system accessing through different communicationmodes (X.25, the Ethernet, PSTN).
Access mode of service agent
network
X.25,
the Ethernet
PSTN
201
202
-
7/27/2019 05 HLR System Structure(CDMA)
45/48
Detailed function include:
1. Msdata:add ms,query/modify ms,delete ms,change MDN,query MS
location,query ms status;
2. Authentication
add/delete authentication data singly,query/modify authenticationdata, authentication indication;
3. Batchprocess
add/modify bulk authentication data; add /delete/modify bulk ms;
-
7/27/2019 05 HLR System Structure(CDMA)
46/48
The step of opening an account:
1. Add authentication data :single/batch
2. Add ms:
the number allocation operation means to match the MDN and MIN
and meanwhile set subscription data of the mobile subscribers.(1) input MIN and MDN
(2) set service data
(3) after correct data setting,click the ok button to add ms.
-
7/27/2019 05 HLR System Structure(CDMA)
47/48
-
7/27/2019 05 HLR System Structure(CDMA)
48/48