04 Mki Process Slave Preparation

1
MASTER KEY INJECTOR PREPARATION AND SLAVE KEY LOADING PROCESS 1) Take a blank Vx520 Gprs Terminal to Prepare a Master Key Injector terminal. 2) Load the Key Injection application through Pc / Pen drive in the Vx520 Master Key Injector terminal. 3) After Downloading the Application in the Master Key Injector Terminal it will display menu CONFIGURE ABOUT on the main screen. 4) Go to the CONFIGURE option Select CONNECTIVITY as GPRS. 5) In CONFIGURE option Select CONFIGURE PARAMS to enter TID,MID,NII,TXN IP,TXN PORT,APN Note: MID TID should be of MASTER Terminal only & IP PORT of GPRS. 6) For Master Key Injection terminal fresh key is required if already allocated kindly deactivate & reallocate. 7) In CONFIGURE option Select KEY INJECTION for Loading Keys in the Master Key injection terminal from Insight through Normal Key injection Process Note: Only the First Key is required (i.e. Normal Key) and not the (Le Key). 8) Prepare a Slave terminal with Application & Rev in it & connect it through the T2T cable. 9) Now in the slave terminal go to BANK FUNCTION > SETUP > KEY INJECTION > Load via MKI in slave terminal. 10) Slave Terminal will get connected through T2T cable with Master Key Injector terminal and Fetch Normal Key & Le Key from Insight. 11) Master Key Injector Terminal Will show Series : VERIX Serial No: ?????????? Master : TMK download and will print a Chargeslip Date, Time, Key Download Report, Slave Serial Number, Slave Key KVC (Check Digit). 12) Slave Terminal will show Load Pin Key... Key Injection Successful... Press Enter. 13) Slave Terminal will show Load Line Key... Key Injection SuccessfulPress Enter. 14) Slave terminal will print INJECTED KEY KVC : (Check Digit)

description

xczdfdfsd

Transcript of 04 Mki Process Slave Preparation

Page 1: 04 Mki Process Slave Preparation

MASTER KEY INJECTOR PREPARATION AND SLAVE KEY LOADING PROCESS

1) Take a blank Vx520 Gprs Terminal to Prepare a Master Key Injector terminal. 2) Load the Key Injection application through Pc / Pen drive in the Vx520 Master Key Injector terminal. 3) After Downloading the Application in the Master Key Injector Terminal it will display menu CONFIGURE ABOUT on the main screen. 4) Go to the CONFIGURE option Select CONNECTIVITY as GPRS. 5) In CONFIGURE option Select CONFIGURE PARAMS to enter TID,MID,NII,TXN IP,TXN PORT,APN Note: MID TID should be of MASTER Terminal only & IP PORT of GPRS. 6) For Master Key Injection terminal fresh key is required if already allocated kindly deactivate & reallocate. 7) In CONFIGURE option Select KEY INJECTION for Loading Keys in the Master Key injection terminal from Insight

through Normal Key injection Process Note: Only the First Key is required (i.e. Normal Key) and not the (Le Key).

8) Prepare a Slave terminal with Application & Rev in it & connect it through the T2T cable. 9) Now in the slave terminal go to BANK FUNCTION > SETUP > KEY INJECTION > Load via MKI in slave terminal. 10) Slave Terminal will get connected through T2T cable with Master Key Injector terminal and Fetch Normal Key &

Le Key from Insight. 11) Master Key Injector Terminal Will show

Series : VERIX Serial No: ?????????? Master : TMK download and will print a Chargeslip Date, Time, Key Download Report, Slave Serial Number, Slave Key KVC (Check Digit).

12) Slave Terminal will show Load Pin Key... Key Injection Successful... Press Enter. 13) Slave Terminal will show Load Line Key... Key Injection Successful… Press Enter. 14) Slave terminal will print INJECTED KEY KVC : (Check Digit)