03 Distribution Board DC Isolator 40-55A-EN€¦ · DISTRIBUTION BOARD DC ISOLATOR CONTACT...
Transcript of 03 Distribution Board DC Isolator 40-55A-EN€¦ · DISTRIBUTION BOARD DC ISOLATOR CONTACT...
1、Reliable switching up to 1500V DC21B.
2、Single-channel current can up to 40-55A.
3、Lever operated with safety lock.
4、03_Distribution Board installation.
5、Modular design, optional 2-8 levels.
6、Pass through the international certification like IEC/SAA / CE/TUV etc.
7、Imported seals make sure the installation machines reach IP66 standard.
Product Features
PEDS40/55-DB-X
Dimensions
PEDS40/55-DB-X
DISTRIBUTION BOARD DC ISOLATOR
CONTACT CONFIGURATION
KNOB 03
Projoy Electric Co., Ltd.
XinTang Industrial Zone, PingJiang District, Suzhou, China Tel : +86 512 6878 6489 Fax: +86 512 6878 6489 www.projoy-electric.com
46
46
PEDS40/55-DB-XPEDS40/55-DB-X
Technical data Technical data
Ding rail mounting and base mounting
500V 600V 700V 800V 900V 1000V 1200V 1500V19
25
40
55
40
55
72
85
40
55
40
55
40
55
40
55
40
55
40
55
15
20
40
55
40
55
64
80
40
55
40
55
40
55
40
55
40
55
40
55
10
15
35
55
35
55
35
55
35
55
40
55
40
55
40
55
35
55
35
55
8
10
30
45
30
45
30
45
30
45
40
55
40
55
40
55
30
45
30
45
6
8
25
35
25
35
25
35
25
35
40
55
40
55
40
55
25
35
25
35
4
6
20
25
20
25
20
25
20
25
40
55
40
55
40
55
20
25
20
25
/
/
10
15
10
15
10
15
10
15
40
55
40
55
40
55
10
15
10
15
/
/
6
8
6
8
6
8
6
8
30
40
30
40
30
40
6
8
6
8
1
1
2
2
3
3
2
2
4
4
2
2
2
2
2
2
6
6
8
8
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
3
3
4
4
+1+1
-1-1
+1+1
+1+1
-1-1
+1+1
-1-1
+2+2
-2-2
+1
+1
-1-1
+1
+1
-1
-1
+1
+1
-1
-1
+1+1
-1-1
+2+2
-2-2
+3+3
-3-3
+1+1
-1-1
+2+2
-2-2
+3+3
-3-3
+4+4
-4-4
+1+1
-1/-2
+2+2
-1/-2
Data according to IEC60947-3(ed.3.2):2015, utilization category DC-PV0/DC-PV1 Poles inseries
No.ofStrings
PartNumber
ContactConfiguration
Data according to IEC60947-3(ed.3.2):2015, utilization category DC-PV0/DC-PV1
Main ParametersRated insulation voltage Rated thermal current rated impulse withstand voltage
rated short-time withstand current (1s)
rated short-circuit making capacity
rated conditional short-circuit currentMax. fuse sizeMaximum cable cross sections (incl. jumper)solid or standardflexibleflexible (+ multicore cable end)TorqueTightening torque terminal screws M4.Tightening torque panel mounting screws ST4.2(304 stainless steel)Tightening torque single hole mounting nut M16Tightening torque knob screws M3Switching on or off torquePower loss per switch Max.24682H3H4HGeneral parametersmethod of mounting
type of knob
knob positionsMechanical lifenumber of DC polesDistance of contacts (per pole)Operation temperatureStorage temperaturePollution degreeOvervoltage categoryIP rating of shafte and mounting nut
Ui
Ithe
Uimp
Icw
Icm
Icc
gL (gG)
Type DB40 DB55
2, 4, 6, 82H, 3H, 4H2, 4, 6, 82H, 3H, 4H
VAVAAAAAA
mm2
mm2
mm2
NmNmNmNmNm
WWWWWWW
1500V40V
8000VA2,A4:1200A2+2:2000
A2,A4:1200A2+2:2000
5000A125
4-164-104-10
481216234
61218243
4.56
1500V55V
8000VA2,A4:1400A2+2:2400
A2,A4:1400A2+2:2400
5000A160
4-164-104-10
1.2-1.3NA
2.0-2.30.5-0.70.9-1.9
A B
OFF at 12 hr,ON at 3 hr;( OFF at 9 hr,ON at 12 hr optional)10,000
2 or 4(6/8 pole optional)8
-40 to +70-40 to +85
2III
IP66
mm
℃
℃
PEDS150-DB40-1
PEDS150-DB55-1
PEDS150-DB40-2
PEDS150-DB55-2
PEDS150-DB40-3
PEDS150-DB55-3
PEDS150-DB40-2H
PEDS150-DB55-2H
PEDS150-DB40-4
PEDS150-DB55-4
PEDS150-DB40-4S
PEDS150-DB55-4S
PEDS150-DB40-4T
PEDS150-DB55-4T
PEDS150-DB40-4B
PEDS150-DB55-4B
PEDS150-DB40-6
PEDS150-DB55-6
PEDS150-DB40-8
PEDS150-DB55-8
40
55
40
55
40
55
40
55
40
55
40
55
40
55
30
40
4
4
2
2
PEDS150-DB40-8(4S*2)
PEDS150-DB55-8(4S*2)
+1
+1
-1-1
+2
+2
-2-2