April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
1/2
SIMATIC PRODUCT SIMATIC PRODUCT OVERVIEWOVERVIEW
SIEMENS
SIEMENS
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
2/2
SIEMENS
Objectives
- Overview On Simatic S7 Product.
- Familiar With S7-200, S7-300 & S7-400.
- Different Between Siemens Programming Device.
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
3/2
SIMATIC PRODUCT OVERVIEW
SIEMENS
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
4/2
SIMATIC OVERVIEW
SIEMENS
SIMATIC NET
Operating PanelPG
S7-400S7-300S7-200
ProfiBusEthernet
MPI
DP Slaves
ProfiBus DPBus System
PC Panel
DP/PA
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
5/2
Bus System
SIEMENS
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
6/2
SIMATIC S7-200
• The micro PLC that offers maximum automation at minimum cost.• Extremely simple installation, programming and operation.• Large-scale integration, space-saving, powerful.• Can be used both for simple and complex automation tasks.
• Suitable for applications where programmable controllers would not have been economically viable in the past.• With powerful communication options (PPI, PROFIBUS DP, AS-Interface)• Digital inputs/outputs to supplement the onboard I/Os of the CPUs
• EM 277: For connecting S7-22x to PROFIBUS DP and MPI• EM 253: Function modules for simple positioning tasks (1 axis)• EM 231: For user-friendly, high precision temperature detection
CPU’s
DI/DOAI/AO
EM 231 thermocouple module
EM 253 positioning module
EM 277 PROFIBUS DP module
SIEMENS
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
7/2
CPU 313C-2 DPCPU 319-3 PN/DP
CPU 317T-2 DP CPU 315-2 DP
CPU 313C-2 DP The compact CPU with integrated digital I/Os and PROFIBUS DP master/slave interface.
CPU 315-2 DP The CPU with medium to large program memory, High processing performance in binary and floating-point arithmetic, PROFIBUS DP master/slave interface.
CPU 319-3 PN/DP The CPU with high command processing performance, large program memory and quantity framework for demanding applications, Used as central controller in production lines with central and distributed I/O on PROFIBUS and PROFINET.
CPU 317T-2 DP The CPU with integrated technology/motion control functionality, For multi-sector automation tasks in the construction of series machines, special machines and plants.
SIMATIC S7-300
SIEMENS
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
8/2
SIMATIC S7-300
CPU IM DI DO AI AO FM CP
CPU S7-300
Signal Modules:Digital input modulesDigital output moduleAnalog input modules Analog output modules
Interface Modules: The IM360/IM361 and IM365 make multi-tier configurations possible.
Function Module (FM) - Counting
- Positioning
- Closed-loop control.
Communication Processors (CP) - Point-to-Point connections
- PROFIBUS - Industrial Ethernet.
SIEMENS
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
9/2
CPU 313C-2 DP:• The compact CPU with integrated digital I/Os • PROFIBUS DP master/slave interface• With process-related functions• For tasks with special functions• For the connection of standalone I/O devicesNote: Micro memory card required to operate the CPU.
Signal Modules:Digital input modules
Digital output module
Analog input modules
Analog output modules
Memory Card A slot is provided for a memory card. The memory card saves the program contents in the event of a power outage without the need for battery.
• RAM cards are available with a capacity of: 64KByte, 256KByte, 1MByte, 2MByte.• Flash EPROM cards are available with a capacity of: 64KByte, 256KByte, 1MByte, 2MByte, 4MByte, 8MByte, 16MByte.
CPU DI DO AI AO
Training Unit Hardware
SIEMENS
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
10/2
Mode Selector:
MRES =Memory reset function (Module Reset) STOP = Stop mode, the program is not executed. RUN = Program execution
Status Indicators.SF = Internal CPU fault or fault in module.BATF = Battery fault; battery empty or non-existent.DC5V = Internal 5 VDC voltage indicator.FRCE = FORCE; indicates that at least one input or output is forced.RUN = Flashes when the CPU is starting up, then a steady light in Run mode.STOP = Shows a steady light in Stop mode.
Flashes slowly for a memory reset request, Flashes quickly when a memory reset is being carried out, Flashes slowly when a memory reset is necessary because a memory card has been inserted.
Training Unit Hardware
SIEMENS
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
11/2
SIMATIC S7-400
CPU 416-2CPU 414-4H
CPU 414-4FH
• High-performance CPUs in the high-end performance range• Applicable for plants with high requirements in the high-end performance range
CPU 416-2
CPU 414-4H• Fault-tolerant automation system with redundant configuration• For applications with high failure safety requirements•Processes with high restart costs, expensive downtimes, little supervision, and few maintenance options• Hot standby: Automatic reaction-free switching to the standby unit in the event of a fault
CPU 414-4FH• Failsafe automation system for plant with high safety requirements• If required, also fault tolerant through redundant configuration
SIEMENS
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
12/2
Rack UR2-H (18 Slot) Rack UR2 (9 Slot)
PS CPU DI DO FM CP IM
• The power PLC for the mid to upper performance range• Performance-graded range of CPUs• Extensive selection of modules• Expandable design to over 300 modules•Backplane bus integrated in the modules•Can be networked with - (MPI) - PROFIBUS - Industrial Ethernet
• UR1 (Universal Rack) with up to 18 modules• UR2 (Universal Rack) with up to 9 modules • UR2-H (Universal Rack For H-SYS)• ER1 (Expansion Rack) with up to 18 modules •ER2 (Expansion Rack) with up to 9 modules
S7-400 Rack
SIMATIC S7-400
SIEMENS
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
13/2
Fault LEDsLEDs for the CPU‘s statuses and faults, both internal and external
Memory Cards
Mode SelectorMRES = Memory reset function (Module RESet)STOP = STOP modeRUN = Program execution, read-only access possible from PG.RUN-P= Program execution, read/write access possible from PG.
MPI / DP Interface
DP InterfaceFor connecting to distributed peripherals
EXT-BATT
SIMATIC S7-400
SIEMENS
April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved
14/2
Field PGIntel Pentium M processor.
Power PG
SIMATIC Programming Device
SIEMENS