Objectives

- Overview On Simatic S7 Product.

- Familiar With S7-200, S7-300 & S7-400.

- Different Between Siemens Programming Device.

Page 3: 02

April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved

3/2

SIMATIC PRODUCT OVERVIEW

SIEMENS

Page 4: 02

April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved

4/2

SIMATIC OVERVIEW

SIEMENS

SIMATIC NET

Operating PanelPG

S7-400S7-300S7-200

ProfiBusEthernet

MPI

DP Slaves

ProfiBus DPBus System

PC Panel

DP/PA

Page 5: 02

April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved

5/2

Bus System

SIEMENS

Page 6: 02

April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved

6/2

SIMATIC S7-200

• The micro PLC that offers maximum automation at minimum cost.• Extremely simple installation, programming and operation.• Large-scale integration, space-saving, powerful.• Can be used both for simple and complex automation tasks.

• Suitable for applications where programmable controllers would not have been economically viable in the past.• With powerful communication options (PPI, PROFIBUS DP, AS-Interface)• Digital inputs/outputs to supplement the onboard I/Os of the CPUs

• EM 277: For connecting S7-22x to PROFIBUS DP and MPI• EM 253: Function modules for simple positioning tasks (1 axis)• EM 231: For user-friendly, high precision temperature detection

CPU’s

DI/DOAI/AO

EM 231 thermocouple module

EM 253 positioning module

EM 277 PROFIBUS DP module

SIEMENS

Page 7: 02

April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved

7/2

CPU 313C-2 DPCPU 319-3 PN/DP

CPU 317T-2 DP CPU 315-2 DP

CPU 313C-2 DP The compact CPU with integrated digital I/Os and PROFIBUS DP master/slave interface.

CPU 315-2 DP The CPU with medium to large program memory, High processing performance in binary and floating-point arithmetic, PROFIBUS DP master/slave interface.

CPU 319-3 PN/DP The CPU with high command processing performance, large program memory and quantity framework for demanding applications, Used as central controller in production lines with central and distributed I/O on PROFIBUS and PROFINET.

CPU 317T-2 DP The CPU with integrated technology/motion control functionality, For multi-sector automation tasks in the construction of series machines, special machines and plants.

SIMATIC S7-300

SIEMENS

Page 8: 02

April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved

8/2

SIMATIC S7-300

CPU IM DI DO AI AO FM CP

CPU S7-300

Signal Modules:Digital input modulesDigital output moduleAnalog input modules Analog output modules

Interface Modules: The IM360/IM361 and IM365 make multi-tier configurations possible.

Function Module (FM) - Counting

- Positioning

- Closed-loop control.

Communication Processors (CP) - Point-to-Point connections

- PROFIBUS - Industrial Ethernet.

SIEMENS

Page 9: 02

April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved

9/2

CPU 313C-2 DP:• The compact CPU with integrated digital I/Os • PROFIBUS DP master/slave interface• With process-related functions• For tasks with special functions• For the connection of standalone I/O devicesNote: Micro memory card required to operate the CPU.

Signal Modules:Digital input modules

Digital output module

Analog input modules

Analog output modules

Memory Card A slot is provided for a memory card. The memory card saves the program contents in the event of a power outage without the need for battery.

• RAM cards are available with a capacity of: 64KByte, 256KByte, 1MByte, 2MByte.• Flash EPROM cards are available with a capacity of: 64KByte, 256KByte, 1MByte, 2MByte, 4MByte, 8MByte, 16MByte.

CPU DI DO AI AO

Training Unit Hardware

SIEMENS

Page 10: 02

April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved

10/2

Mode Selector:

MRES =Memory reset function (Module Reset) STOP = Stop mode, the program is not executed. RUN = Program execution

Status Indicators.SF = Internal CPU fault or fault in module.BATF = Battery fault; battery empty or non-existent.DC5V = Internal 5 VDC voltage indicator.FRCE = FORCE; indicates that at least one input or output is forced.RUN = Flashes when the CPU is starting up, then a steady light in Run mode.STOP = Shows a steady light in Stop mode.

Flashes slowly for a memory reset request, Flashes quickly when a memory reset is being carried out, Flashes slowly when a memory reset is necessary because a memory card has been inserted.

Training Unit Hardware

SIEMENS

Page 11: 02

April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved

11/2

SIMATIC S7-400

CPU 416-2CPU 414-4H

CPU 414-4FH

• High-performance CPUs in the high-end performance range• Applicable for plants with high requirements in the high-end performance range

CPU 416-2

CPU 414-4H• Fault-tolerant automation system with redundant configuration• For applications with high failure safety requirements•Processes with high restart costs, expensive downtimes, little supervision, and few maintenance options• Hot standby: Automatic reaction-free switching to the standby unit in the event of a fault

CPU 414-4FH• Failsafe automation system for plant with high safety requirements• If required, also fault tolerant through redundant configuration

SIEMENS

Page 12: 02

April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved

12/2

Rack UR2-H (18 Slot) Rack UR2 (9 Slot)

PS CPU DI DO FM CP IM

• The power PLC for the mid to upper performance range• Performance-graded range of CPUs• Extensive selection of modules• Expandable design to over 300 modules•Backplane bus integrated in the modules•Can be networked with - (MPI) - PROFIBUS - Industrial Ethernet

• UR1 (Universal Rack) with up to 18 modules• UR2 (Universal Rack) with up to 9 modules • UR2-H (Universal Rack For H-SYS)• ER1 (Expansion Rack) with up to 18 modules •ER2 (Expansion Rack) with up to 9 modules

S7-400 Rack

SIMATIC S7-400

SIEMENS

Page 13: 02

April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved

13/2

Fault LEDsLEDs for the CPU‘s statuses and faults, both internal and external

Memory Cards

Mode SelectorMRES = Memory reset function (Module RESet)STOP = STOP modeRUN = Program execution, read-only access possible from PG.RUN-P= Program execution, read/write access possible from PG.

MPI / DP Interface

DP InterfaceFor connecting to distributed peripherals

EXT-BATT

SIMATIC S7-400

SIEMENS

Page 14: 02

April 17, 2023SIMATIC S7SIEMENS LTD EGYPT 2007All Rights Reserved

14/2

Field PGIntel Pentium M processor.

Power PG

SIMATIC Programming Device

SIEMENS