DK Cable Junction Boxes
DK Cable Junction Boxes- 1.5 up to 240 mm
- Degree of protection IP 54-67
- Cable Junction Boxes are VDE tested in accordance with IEC 60670-22
i
Assembling videos
-
16
DK Cable Junction Boxes Content
Criteria for selecting 18 - 19Box walls 20
Box walls without knockoutsfrom 1.5 up to 50 mm2
IP 65box walls without knockouts, can be drilled individually for customized requirements- without terminals 33 - 34- without terminals, for electrical equipment up to 63 A 35 - 36- Accessories 37 - 39
With or without terminalsfrom 1.5 up to 240 mm2
IP 65/IP 55cable entry via metric knockouts- with terminals for copper conductors 24 - 29- without terminals 30 - 31
With FIXCONNECT plug-in technology for copper conductorsfrom 1.5 up to 16 mm2
IP 65/IP 55cable entry via metric knockouts 22
For aluminium- (Alu) and copper (Cu) conductorsfrom 1.5 up to 240 mm2
IP 65/55cable entry via metric knockouts- with terminal blocks for aluminium- (Alu) and copper (Cu) conductors 54 - 60
Cable entry via elastic membranes and integrated M20 threadup to 4 mm2
IP 55- without terminals 41- with terminals for copper conductors 41
Cable entry via cable, cable trunking and conduitsfrom 1.5 up to 4 mm2
IP 54- with terminals for copper conductors 43 - without terminals, Accessories 44
Cable entry via elastic membranesfrom 1.5 up to 4 mm2
IP 55- with terminals for copper conductors, grey RAL 7035 46- without terminals, grey RAL 7035 47- with terminals for copper conductors, white RAL 9016 48- without terminals, white RAL 9016, Accessories 49
Cable entry via elastic membranes from the rear and by box walls and lidfrom 1.5 up to 2.5 mm2
IP 55for the clip-on attachment- with terminals for copper conductors, grey RAL 7035 51- without terminals, grey RAL 7035 51- with terminals for copper conductors, white RAL 9016 52- without terminals, white RAL 9016 52
"Weatherproof" - for outdoor installation - harsh environment and/or outdoorfrom 1.5 up to 50 mm2
IP 66cable/conduit entry via metric knockouts- with / without terminals, colours grey RAL 7032, black RAL 9011 62 - 69box walls without knockouts - without terminals, colours grey RAL 7032, black RAL 901 71 - 74
-
17
DK Cable Junction Boxes Content
Additional information and planning tools (e.g. CAD parts libraries) can be found on the Internet at www.hensel-electric.in
"Waterproof" - for outdoor installation - harsh environment and/or outdoorfrom 1,5 up to 10 mm2 cable entry via metric knockouts- for encapsulating, colours grey RAL 7032, black RAL 9011 NEW 80 - 84
Tested for intrinsic fire resistance from 0.5 up to 16 mm2IP 65 / IP 66- material: duroplast, cable entry via included grommets, IP 65 94 - 95, 101- material: sheet steel, powder-coated, cable entry via mounted grommets, IP 66 96 - 100, 101
For special applicationsfrom 1.5 up to 25 mm2
IP 55 / IP 65cable entry via metric knockouts- for security lighting circuits, with red lid 103- for equipotential bonding conductors 104
With main line branch terminals from 25 up to 35 mm2
IP 55 / IP 65cable/conduit entry via metric knockouts- with terminal blocks for copper conductors 25 mm and 35 mm 106 - 107
With terminal blocks for aluminium- (Alu) and copper conductors (Cu) from 1.5 up to 4 mm2
IP 65cable/conduit entry via metric knockouts - Terminal boxes with terminal blocks 109 - 111
Accessories 113 - 121
"Weatherproof" - for outdoor installation - harsh environment and/or outdoorfrom 1.5 up to 50 mm2
IP 66 / IP 65 with UL/CSA approval, (Nema 4X)box walls without knockouts, can be drilled individually- without terminals 76 - 77
For offshore / heavy duty applicationsfrom 1.5 up to 35 mm2
IP 66 / IP 67cable entry via metric knockouts - with / without terminals 86 - 90box walls without knockouts - without terminals 91 - 92
Technical Details 123 - 134
-
18
DK Cable Junction Boxes Criteria for Selecting
Applications FunctionsBranching andconnecting ofcopper conduc-tors
Branching andconnecting ofaluminium and copper conduc-tors
In rooms with dry climate In damp and wet environments Protected outdoors (refer to technical details) On fl ameable parts of buildings In buildings with mainly infl ammable materials In areas with a high risk of fi re
Pages 22-52 Pages 54-60
Cable trunking installation Pages 43-44
Intrinsic fi re resistance Pages 94-101
"Waterproof" for encapsulating Pages 80-84
Weatherproof, for outdoor installation (harsh environment and/or outdoor)
Improved behaviour in cases of fi re ame-resistant and halogen-free
Pages 62-74
Offshore applications Pages 86-92
Security lighting circuits Page 103
Equipotential bonding Page 104
UL Approval Page 76-77
DNV Approval Germanisch Lloyd Russian Maritime Register of Shipping
Pages 62-92
PA
-
19
DK Cable Junction Boxes Criteria for Selecting
Connecting solid conductors and stranded conduc-tors
Combining multi-ple control wires to one control cable
2 circuits in one box
Main line branch terminals
Without terminals Box walls without knockouts
Page 54-55Pages 109-111
Pages 109-111 Pages 43-44DP 9220,DP 9221,DP 9222
Page 106-107 Pages 30-36, Page 41 DN 2000, DN 2030,Page 44, 47Page 48 DE 9321, Page 49,Page 51 DE 9220,Page 52 DE 9221, Pages 64-65, 68-69, 71-74, 76-77, 89-92Page 103 D 9220, D 9240
Pages 33-36all Boxes,Pages 71-74, 76-77Page 91-92
Pages 43-44DP 9220,DP 9221,DP 9222
Page 44
Pages 64-65Pages 68-69Pages 71-74
Pages 71-74
Pages 89-92 Page 91-92
Page 76-77
Pages 64-65, 68-69Pages 71-74, 89-92
Pages 71-74, 89-92
-
20
Assignment of box walls:
The assignment of box walls is effected via wall symbols that are
assigned to each product. The individual figures 2 give an indication,
which wall is concerned.
Wand4
65 5
Wall 18
4 x M 253 x M 40/50
Wall 19
8 x M 324 x M 40/50
Wall 20
2 x M 2010 x M 251 x M 32/40
Wall 21
1 x M 204 x M 251 x M 32/403 x M 40/50
Wall 22
1 x Elastic membranes
Wall 23
2 x Elastic membranes
Wall 24
3 x Elastic membranes
Wall 11 x M 20
Wall 21 x M 20/25
Wand 32 x M 20
Wall 42 x M 20/25
Wall 51 x M 20/251 x M 25/32
Wall 62 x M 25/32
Wall 72 x M 32
Wall 82 x M 32/40
Wall 92 x M 40
Wall 102 x M 20/251 x M 25/32
Wall 112 x M 20/251 x M 32/40
Wall 121 x M 20/251 x M 25/321 x M 40/50
Wall 131 x M 20/252 x M 40/50
Wall 14
3 x M 25/32
Wall 15
2 x M 25/321 x M 40/50
Wall 16
3 x M 32/40
Wall 17
4 x M 25/321 x M 40/50
Wall 25
1 x Removable-system
Wall 26
2 x Removable-system
Wall 27
3 x Removable-system
Wall 28
4 x Removable-system
DK Cable junction boxes Box Walls
All box walls are listed in the fold-out of the coverpages.
Wall 29
1 x M 63
Wall 30
2 x M 50
Wall 31
4 x up to 16 mm1 x up to 35 mm
-
21
DK Cable Junction Boxes with Terminals in Plug-in Technology Cable Entry via Metric Knockouts
Plenty of space for the wiring: Wiring facilities both below the DIN rails and between the terminals.
Different conductor types - rigid (r) and flexible (f) without treatment of conduc-tors - can be connected in one terminal.
Conductors can be directly connected and disconnected with installed terminal.
Stainless steel cover screws with quick fastening metric thread.Reducing cover xing time.
Burning behaviour:Glow wire test according to IEC 60 695-2-11: 750 C, flame-retardant, self-extinguishing
Labelling system for circuit description Label template on the Internet at
www.hensel-electric.de - in the Downloads area.
-
22
DK Cable Junction Boxes with Terminals in Plug-in Technology Cable Entry via Metric Knockouts
KC 9045
Wall10
106 5
1.5-4 mm, Cu 3~
FIXCONNECT plug-in terminal technology 5-pole per pole 4 x 1 x 1,5-4 mm sol/f, terminal technology,
see annex DK Cable junction boxes included cable entry: 4 ESM 25, sealing range 9-17 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 32 A
139
119
70
KC 9255
Wall16
118 8
2.5-10 mm, Cu 3~
FIXCONNECT plug-in terminal technology 5-pole per pole 4 x 1 x 2.5-10 mm r/f included cable entry: 3 ESM 32, sealing range 9-23 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 50 A
98
160
200
KC 9355
Wall13
1315 15
2.5-16 mm, Cu 3~
FIXCONNECT plug-in terminal technology 5-pole per pole 4 x 1 x 2.5-16 mm r/f included cable entry: 3 ESM 40, sealing range 17-30 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 76 A
117260
210
-
23
DK Cable Junction Boxes Cable Entry via Metric Knockouts
Variable terminal mounting positions (5 positions) and new terminal technology
Included accessories as listed: grommets ESM = IP 55
Hensel cable junction boxes can in general also be used in poor environmental conditions by using IP 65 cable glands AKM/ASM.
Stainless steel cover screws with quick fastening metric thread. Reducing cover xing time.
Burning behaviour:Glow wire test according to IEC 60 695-2-11: 750 C / 960 C, flame-retardant, self-extinguishing
Labelling system for circuit description Label template on the Internet at
www.hensel-electric.de - in the Downloads area.
-
24
DK Cable Junction Boxes Cable Entry via Metric Knockouts
D 9025
Wall
3
13 3
1.5-2.5 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol included cable entry: 4 ESM 20, sealing range 6-13 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
5388
88
D 9125
Wall
3
13 3
1.5-2.5 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol included cable entry: 4 ESM 20, sealing range 6-13 mm with external fixing for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
5388
88
D 9045
Wall
4
24 4
1.5-4 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol,
2 x 6 mm sol included cable entry: 4 ESM 25, sealing range 9-17 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
98 61
98
D 9145
Wall
3
13 3
1.5-4 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol,
2 x 6 mm sol included cable entry: 4 ESM 20, sealing range 6-13 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
98 61
98
-
25
DK Cable Junction Boxes Cable Entry via Metric Knockouts
K 9065
Wall10
106 5
2.5-6 mm, Cu 3~
with terminals 5-pole per pole 4 x 2.5 mm sol, 4 x 4 mm sol, 3 x 6 mm sol,
2 x 10 mm sol included cable entry: 3 ESM 32, sealing range 9-23 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,5 Nm
139
119
70
K 9105
Wall14
106 6
4-10 mm, Cu 3~
with terminals 5-pole per pole 6 x 2.5 mm sol, 4 x 4 mm sol, 4 x 6 mm sol,
4 x 10 mm sol, 2 x 16 mm s included cable entry: 3 ESM 32, sealing range 9-23 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 63 A tightening torque for terminal 2,0 Nm
82167
125
K 9255
Wall16
118 8
10-25 mm, Cu 3~
with terminals 5-pole per pole 6 x 10 mm sol, 4 x 16 mm s, 4 x 25 mm s,
2 x 35 mm s included cable entry: 3 ESM 40, sealing range 17-30 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 102 A tightening torque for terminal 3,0 Nm
98
160
200
K 9502
Wall12
1217 17
10-35 mm, Cu 3~
with terminals 5-pole per pole 4 x 10 mm sol, 4 x 16 mm s, 4 x 25 mm s,
2 x 35 mm s included cable entry: 3 ESM 40, sealing range 17-30 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 102 A tightening torque for terminal 3,0 Nm
310
210 117
-
26
DK Cable Junction Boxes Cable Entry via Metric Knockouts
K 9504
Wall12
1217 17
16-50 mm, Cu 3~
with terminals 4-pole per polel 6 x 16 mm s, 4 x 25 mm s, 4 x 35 mm s,
4 x 50 mm s cable entry via knockouts,
order AKM/ASM separately (refer to index cable entry systems) for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 150 A tightening torque for terminal 12,0 Nm
310
210 117
K 9505
Wall12
1217 17
16-50 mm, Cu 3~
with terminals 5-pole per pole 6 x 16 mm s, 4 x 25 mm s, 4 x 35 mm s,
4 x 50 mm s cable entry via knockouts,
order AKM/ASM separately (refer to index cable entry systems) for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 150 A tightening torque for terminal 12,0 Nm
310
210 117
K 7055
Wall20
2021 21
16-50 mm, Cu 3~
with terminals 5-pole per pole 6 x 16 mm s, 4 x 25 mm s, 4 x 35 mm s,
4 x 50 mm s sealable Order cable glands, flanges and other accessories separately as
required for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 150 A tightening torque for terminal 12,0 Nm
450
300 170
K 9355
Wall15
1513 13
16-35 mm, Cu 3~
with terminals 5-pole per pole 6 x 16 mm s, 4 x 25 mm s, 4 x 35 mm s,
2 x 50 mm s included cable entry: 3 ESM 40, sealing range 17-30 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 125 A tightening torque for terminal 12,0 Nm
117
260
210
-
27
DK Cable Junction Boxes Cable Entry via Metric Knockouts
K 7004
Wall20
2021 21
16-70 mm, Cu 3~
with terminals 4-pole per pole 4 x 16-70 mm s sealable Order cable glands, flanges and other accessories separately as
required for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 216 A tightening torque for terminal 10,0 Nm
450
300 170
K 7005
Wall20
2021 21
16-70 mm, Cu 3~
with terminals 5-pole per polel 4 x 16-70 mm s sealable Order cable glands, flanges and other accessories separately as
required for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 216 A tightening torque for terminal 10,0 Nm
450
300 170
K 1204
Wall20
2021 21
16-150 mm, Cu/Alu 3~
with terminals 4-pole per pole 2 x 16-150 mm, 4 x 16-70 mm,
conductors can be inserted from the front into the clamping unit, terminal technology, see annex DK Cable junction boxes
sealable Order cable glands, flanges and other accessories separately as
required Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 250 A tightening torque for terminal 20,0 Nm
450
300 170
-
28
DK Cable Junction Boxes Cable Entry via Metric Knockouts
K 1205
Wall20
2021 21
16-150 mm, Cu/Alu 3~
with terminals 5-pole per pole 2 x 16-150 mm, 4 x 16-70 mm,
conductors can be inserted from the front into the clamping unit, terminal technology, see annex DK Cable junction boxes
sealable Order cable glands, flanges and other accessories separately as
required Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 250 A tightening torque for terminal 20,0 Nm
450
300 170
K 2404
Wall20
1819 19
25-240 mm, Cu/Alu 3~
with terminals 4-pole per pole 2 x 25-185/240 mm, 4 x 25-120 mm,
conductors can be inserted from the front into the clamping unit, terminal technology, see annex DK Cable junction boxes
sealable Order cable glands, flanges and other accessories separately as
required Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 400 A tightening torque for terminal 40,0 Nm
600
300 170
-
29
DK Cable Junction Boxes Cable Entry via Metric Knockouts
K 2405
Wall20
1819 19
25-240 mm, Cu/Alu 3~
with terminals 5-pole per pole 2 x 25-185/240 mm, 4 x 25-120 mm,
conductors can be inserted from the front into the clamping unit, terminal technology, see annex DK Cable junction boxes
sealable Order cable glands, flanges and other accessories separately as
required Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 400 A tightening torque for terminal 40,0 Nm
600
300 170
-
30
DK Cable Junction Boxes Cable Entry via Metric Knockouts
D 9020
Wall
3
13 3
without terminals included cable entry: 4 ESM 20, sealing range 6-13 mm for normal environment and protected outdoor
5388
88
D 9120
Wall
3
13 3
without terminals with external fixing included cable entry: 4 ESM 20, sealing range 6-13 mm for normal environment and protected outdoor
5388
88
D 9140
Wall
3
13 3
without terminals included cable entry: 4 ESM 20, sealing range 6-13 mm for normal environment and protected outdoor
98 58
98
D 9040
Wall
4
24 4
without terminals included cable entry: 4 ESM 25, sealing range 9-17 mm for normal environment and protected outdoor
98 61
98
K 9060
Wall10
106 5
without terminals included cable entry: 3 ESM 32, sealing range 9-23 mm for normal environment and protected outdoor
139
119
70
K 9100
Wall14
106 6
without terminals included cable entry: 3 ESM 32, sealing range 9-23 mm for normal environment and protected outdoor
82167
125
-
31
DK Cable Junction Boxes Cable Entry via Metric Knockouts
K 9250
Wall16
118 8
without terminals included cable entry: 3 ESM 40, sealing range 17-30 mm for normal environment and protected outdoor
98
160
200
K 9350
Wall13
1315 15
without terminals included cable entry: 3 ESM 40, sealing range 17-30 mm for normal environment and protected outdoor
117260
210
K 9500
Wall12
1217 17
without terminals cable entry via knockouts, order AKM/ASM separately
(refer to index cable entry systems) for normal environment and protected outdoor
310
210 117
-
32
DK Cable Junction Boxes Box Walls without Knockouts
Cable entries can be drilled individually.
Labelling system for circuit description Label template on the Internet at
www.hensel-electric.de - in the Downloads area.
Burning behaviour:Glow wire test according to IEC 60 695-2-11: 750 C, flame-retardant, self-extinguishing
Stainless steel cover screws with quick fastening metric thread. Reducing cover xing time.
-
33
DK Cable Junction Boxes Box Walls without Knockouts
D 8020
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 20 for normal environment and protected outdoor
wall thickness of the bottom part 2,3 mm
5388
88
D 8120
without terminals with external fixing box walls without knockouts wall surface can be drilled individually for cable entry max. M 20 for normal environment and protected outdoor
wall thickness of the bottom part 2,3 mm
5388
88
D 8040
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 20 for normal environment and protected outdoor
wall thickness of the bottom part 2,3 mm
98 58
98 K 8060
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 32 for normal environment and protected outdoor
wall thickness of the bottom part 2,6 mm
139
119
70
K 8100
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 32 for normal environment and protected outdoor
wall thickness of the bottom part 2,8 mm
82167
125
-
34
DK Cable Junction Boxes Box Walls without Knockouts
K 8250
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 40 for normal environment and protected outdoor
wall thickness of the bottom part 3 mm
98
160
200
K 8350
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 50 for normal environment and protected outdoor
wall thickness of the bottom part 3 mm
117260
210
K 8500
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 50 for normal environment and protected outdoor
wall thickness of the bottom part 3 mm
31
0
210 117
-
35
DK Cable Junction Boxes Box Walls without Knockouts
K 0100
with transparent lid lid fasteners for tool operation box walls without knockouts please order DIN rails or mounting plates additionally for normal environment and protected outdoor
rated current for electrical devices up to 63 A wall thickness of the bottom part 3,5 mm
300 170
150
K 0200
with transparent lid lid fasteners for tool operation box walls without knockouts please order DIN rails or mounting plates additionally for normal environment and protected outdoor
rated current for electrical devices up to 63 A wall thickness of the bottom part 3,5 mm
300 170
300
K 0300
with transparent lid lid fasteners for tool operation box walls without knockouts please order DIN rails or mounting plates additionally for normal environment and protected outdoor
rated current for electrical devices up to 63 A wall thickness of the bottom part 3,5 mm
300 170
450
K 0400
with transparent lid lid fasteners for tool operation box walls without knockouts please order DIN rails or mounting plates additionally for normal environment and protected outdoor
rated current for electrical devices up to 63 A wall thickness of the bottom part 3,5 mm
600
300 170
-
36
DK Cable Junction Boxes Box Walls without Knockouts
K 0101
with opaque lid lid fasteners for tool operation box walls without knockouts please order DIN rails or mounting plates additionally for normal environment and protected outdoor
rated current for electrical devices up to 63 A wall thickness of the bottom part 3,5 mm
300 170
150
K 0201
with opaque lid lid fasteners for tool operation box walls without knockouts please order DIN rails or mounting plates additionally for normal environment and protected outdoor
rated current for electrical devices up to 63 A wall thickness of the bottom part 3,5 mm
300 170
300
K 0301
with opaque lid lid fasteners for tool operation box walls without knockouts please order DIN rails or mounting plates additionally for normal environment and protected outdoor
rated current for electrical devices up to 63 A wall thickness of the bottom part 3,5 mm
300 170
450
K 0401
with opaque lid lid fasteners for tool operation box walls without knockouts please order DIN rails or mounting plates additionally for normal environment and protected outdoor
rated current for electrical devices up to 63 A wall thickness of the bottom part 3,5 mm
600
300 170
-
37
DK Cable Junction Boxes Empty Boxes Accessories for Cable Junction Boxes K0x0x
Mi TS 15
DIN raillength 134 mm in accordance with DIN EN 60 715 for Mi Empty box size 1 for equipment or terminals with clip-on mounting with fixing screws
35
15134
Mi TS 30
DIN raillength 284 mm in accordance with DIN EN 60 715 for Mi empty box sizes 1 to 8 for equipment or terminals with clip-on mounting with fixing screws
35
15284
Mi TS 45
DIN raillength 434 mm in accordance with DIN EN 60 715 for Mi empty box size 3 for equipment or terminals with clip-on mounting with fixing screws
35
15434
Mi TS 60
DIN raillength 584 mm in accordance with DIN EN 60 715 for Mi empty box sizes 4 and 8 for equipment or terminals with clip-on mounting with fixing screws
35
15584
Mi MP 1
Mounting plateW 259 x H 115 mm material thickness 4 mm for Mi-Empty boxes sizes 1, 2, 3, 4 with fixing screws
259
115
Mi MP 2
Mounting plateW 265 x H 265 mm material thickness 4 mm for Mi-Empty boxes sizes 2 to 8 with fixing screws
265
265
-
38
DK Cable Junction Boxes Empty Boxes Accessories for Cable Junction Boxes K0x0x
Mi MP 3
Mounting plateW 265 x H 415 mm material thickness 4 mm for Mi-Empty boxes sizes 3, 4 with fixing screws
415
265
Mi MP 4
Mounting plateW 265 x H 565 mm material thickness 4 mm for Mi-Empty boxes sizes 4, 8 with fixing screws
565
265
Mi PL 2
Sealing cap 2 sealing caps for converting the lid fasteners
Mi SR 4
Conversion setfor manual operation on tool operation 4 fastening covers
Mi SN 4
Conversion setfor converting lid fasteners from tool to manual operation 4 manual actuators
-
39
DK Cable Junction Boxes Empty Boxes Accessories for Cable Junction Boxes K0x0x
Mi DV 01
L ocking device insertion only in connection with Mi PL 2, Mi SR 4 or Mi SN 4
Mi ZS 11
Lid lockwith locking device I Is being used instead of fasteners for hand or tool operation in
order to prevent unauthorised opening of the lids consisting of: cylinder lock, keys, locking device insertion, dust
cover
Mi ZS 12
Lid lockwith locking device II Is being used instead of fasteners for hand or tool operation in
order to prevent unauthorised opening of the lids consisting of: cylinder lock, keys, locking device insertion, dust
cover
Mi DR 04
Lid fastener for tool operationtriangle 8 mm is used instead of fasteners for hand- or tool operation, in order to
make unauthorized opening of lids more difficult 4 locking devices with triangle 8 mm and key
DS 1
Triangular key 8 mm
Mi AL 40
4 stainless steel external brackets for external fixing of enclosures
-
40
DK Cable Junction Boxes Cable Entry via Elastic Membranes and Integrated M 20 Thread
IP 55 with cable entry via elastic membranes.
IP 65 with ADM 20 cable gland without locknut. The gland is secured by an integrated M 20 thread.
Captive cover screws with quick-release lock.
Burning behaviour:Glow wire test according to IEC 60 695-2-11: 750 C, flame-retardant, self-extinguishing
-
41
DK Cable Junction boxes Cable Entry via Elastic Membranes and Integrated M 20 Thread
DN 2035
Wall
3
33 3
1.5-2.5 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol cable entry via elastic membranes and integrated M 20 thread 8 elastic membranes, closed, sealing range 3-12 mm included cable entry: 3 ADM 20, sealing range 6,5-13,5 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
DN 2005
Wall
3
33 3
1.5-2.5 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol cable entry via elastic membranes and integrated M 20 thread 8 elastic membranes, closed, sealing range 3-12 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
DN 2030
Wall
3
33 3
without terminals cable entry via elastic membranes and integrated M 20 thread 8 elastic membranes, closed, sealing range 3-12 mm included cable entry: 3 ADM 20, sealing range 6,5-13,5 mm
DN 2000
Wall
3
33 3
without terminals cable entry via elastic membranes and integrated M 20 thread 8 elastic membranes, closed, sealing range 3-12 mm for normal environment and protected outdoor
ADM 20
ISO thread M 20 x 1.5
sealing range 6,5-13,5 mm with strain relief for indoor - normal environment and (or) protected outdoor installation ambient temperature - 25 to + 35 C glow wire test IEC 60 695-2-11: 750 C
tightening torque 2,0 Nm
-
42
DK Cable Junction Boxes Cable Entry via Knockouts for Cable Trunking and Conduit Installation
Simply cut out cable trunking wall to the required width.
The cables can be inserted from the front! No threading of cables neccessary!
Supplied accessory grommets DPS 02 = IP 54
The clean installation solution for cable trunking!
Removable trunking adapters for connection of cable trunkings to junction boxes.
Stainless steel cover screws with quick fastening metric thread. Reducing cover xing time.
Burning behaviour:Glow wire test according to IEC 60 695-2-11: 750 C, flame-retardant, self-extinguishing
Labelling system for circuit description Label template on the Internet at
www.hensel-electric.de - in the Downloads area.
-
43
DK Cable Junction Boxes Cable Entry via Knockouts for Cable Trunking and Conduit Installation
DP 9025
Wall26
2526 26
1.5-2.5 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol for cable trunking and conduit installation included cable entry: 4 DPS 02, sealing range 10-13,5 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
5088
88
DP 9221
Wall28
2727 27
1.5-2.5 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol for cable trunking and conduit installation included cable entry: 7 DPS 02, sealing range 10-13,5 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
50139
119
DP 9222
Wall28
2727 27
1.5-2.5 mm, Cu 3~
with 2 terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol for cable trunking and conduit installation included cable entry: 7 DPS 02, sealing range 10-13,5 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
50139
119
DPC 9225
Wall28
2727 27
1.5-2.5 mm, Cu 3~
FIXCONNECT plug-in terminal technology 5-pole per pole 4 x 1 x 1.5-2.5 mm sol/f, terminal technology,
see annex DK Cable junction boxes for cable trunking and conduit installation included cable entry: 4 DPS 02, sealing range 10-13,5 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 32 A
50139
119
-
44
DK Cable Junction Boxes Cable Entry via Knockouts for Cable Trunking and Conduit Installation
DP 9020
Wall26
2526 26
without terminals for cable trunking and conduit installation included cable entry: 4 DPS 02, sealing range 10-13,5 mm for normal environment and protected outdoor
5088
88
DP 9220
Wall28
2727 27
without terminals for cable trunking and conduit installation included cable entry: 7 DPS 02, sealing range 10-13,5 mm for normal environment and protected outdoor
50139
119
DPS 02
Removable grommet
degree of protection: IP 54 sealing range 10-13.5 mm for retrofitting for cable junction boxes DP 9020, DP 9220, DP 9025, DP 9221, DP 9222, DP 9026, DPC 9225
ERA 20
Removable conduit adapter
degree of protection: IP 54 sealing range 10-13.5 mm for wiring conduits M 20 for cable junction boxes DP 9020, DP 9220, DP 9025, DP 9221, DP 9222, DP 9026, DPC 9225
EKA 20
Removable trunking adapter
degree of protection: IP 54 sealing range 10-13.5 mm for mini trunking up to 20 x 20 mm for cable junction boxes DP 9020, DP 9220, DP 9025, DP 9221, DP 9222, DP 9026, DPC 9225
-
45
DK Cable Junction Boxes Cable Entry via Elastic Membranes
No punching tool required - insert the conductor and its done
Degree of protection IP 55
Grommet supplied for sealing membra-nes in case of modifications.
Box wall with 3 cable entries Stainless steel cover screws with quick fastening metric thread. Reducing cover xing time.
Burning behaviour:Glow wire test according to IEC 60 695-2-11: 750 C, flame-retardant, self-extinguishing
Labelling system for circuit description Label template on the Internet at
www.hensel-electric.de - in the Downloads area.
-
46
DK Cable Junction Boxes Cable Entry via Elastic Membranes
DE 9325
Wall24
2423 23
1.5-2.5 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol 10 elastic membranes, closed cable entries,
sealing range 6.5-16 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
4788
88
DE 9345
Wall24
2423 23
1.5-4 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol,
2 x 6 mm sol 10 elastic membranes, closed cable entries,
sealing range 6.5-18 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
98
98 52
DE 9335
Wall24
2423 23
1.5-4 mm, Cu 3~
terminals with wire protection 5-pole per pole 4 x 1.5 mm sol/s/f, 4 x 2.5 mm sol/s/f,
2 x 4 mm sol/s/f 10 elastic membranes, closed cable entries,
sealing range 6.5-16 mm with cable retention (2 pc.) for cable tie up to 6.5 mm width for normal environment and protected outdoor
rated insulation voltage AC/DC 500 V rated current 32 A tightening torque for terminal 0,8 Nm Dismantling length 6 mm
4788
88
-
47
DK Cable Junction Boxes Cable Entry via Elastic Membranes
DE 9320
Wall24
2423 23
without terminals 10 elastic membranes, closed cable entries,
sealing range 6.5-16 mm for normal environment and protected outdoor
4788
88
DE 9340
Wall24
2423 23
without terminals 10 elastic membranes, closed cable entries,
sealing range 6.5-18 mm for normal environment and protected outdoor
98
98 52
DE 9330
Wall24
2423 23
without terminals 10 elastic membranes, closed cable entries,
sealing range 6.5-16 mm with cable retention (2 pc.) for cable tie up to 6.5 mm width for normal environment and protected outdoor
4788
88
DE 9350
Wall24
2423 23
without terminals 10 elastic membranes, closed cable entries,
sealing range 6.5-18 mm with cable retention (2 pc.) for cable tie up to 6.5 mm width for normal environment and protected outdoor
98
98 52
-
48
DK Cable Junction Boxes Cable Entry via Elastic Membranes
DE 9326
Wall24
2423 23
1.5-2.5 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol 10 elastic membranes, closed cable entries,
sealing range 6.5-16 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
4788
88
DE 9346
Wall24
2423 23
1.5-4 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol,
2 x 6 mm sol 10 elastic membranes, closed cable entries,
sealing range 6.5-18 mm for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
98
98 52
DE 9336
Wall24
2423 23
1.5-2.5 mm, Cu 3~
terminals with wire protection 5-pole per pole 4 x 1.5 mm sol/s/f, 4 x 2.5 mm sol/s/f,
2 x 4 mm sol/s/f 10 elastic membranes, closed cable entries,
sealing range 6.5-16 mm with cable retention (2 pc.) for cable tie up to 6.5 mm width for normal environment and protected outdoor
rated insulation voltage AC/DC 500 V rated current 32 A tightening torque for terminal 0,8 Nm Dismantling length 11 mm
4788
88
DE 9321
Wall24
2423 23
without terminals 10 elastic membranes, closed cable entries,
sealing range 6.5-16 mm for normal environment and protected outdoor
4788
88
-
49
DK Cable Junction Boxes Cable Entry via Elastic Membranes
DE 9341
Wall24
2423 23
without terminals 10 elastic membranes, closed cable entries,
sealing range 6.5-18 mm for normal environment and protected outdoor
98
98 52
DE 9331
Wall24
2423 23
without terminals 10 elastic membranes, closed cable entries,
sealing range 6.5-16 mm with cable retention (2 pc.) for cable tie up to 6.5 mm width for normal environment and protected outdoor
4788
88
DE 9351
Wall24
2423 23
without terminals 10 elastic membranes, closed cable entries,
sealing range 6.5-18 mm with cable retention (2 pc.) for cable tie up to 6.5 mm width for normal environment and protected outdoor
98
98 52
KHR 01
Cable retentionfor cable diameter 6,5 - 14 mm set with 10 x 6 cable rentention rings 30 pieces for cable diameter 6,5 - 10 mm 30 pieces for cable diameter 10 - 14 mm
KHR 02
Cable retentionfor cable diameter 10 - 16 mm set with 10 x 6 cable rentention rings 30 pieces for cable diameter 10 - 14 mm 30 pieces for cable diameter 13 - 16 mm
DK ZE 10
Cable retention set with 10 pieces for fixing in the bottom part of DK-cable junction boxes cable retention with cable clip up to 6.5 mm
-
50
DK Cable Junction Boxes Cable Entry via Elastic Membranes in Bottom and Box Walls
Cable entry from the rear via elastic membranes in the bottom
Lid for clip-on attachment. Reducing cover xing time
Flexible elastic membranes -no cable glands required. Push through and tight!
Cable entry via elastic membranes in box walls
Burning behaviour:Glow wire test according to IEC 60 695-2-11: 750 C, flame-retardant, self-extinguishing
-
51
DK Cable Junction Boxes Cable Entry via Elastic Membranes in Bottom and Box Walls
DE 9225
Wall23
2324 24
1.5-2.5 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol box walls with 10 elastic membranes, closed, sealing range
3-14 mm, bottom with 2 elastic membranes, closed lid with clip-on attachment for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
DE 9220
Wall23
2324 24
without terminals box walls with 10 elastic membranes, closed, sealing range
3-14 mm, bottom with 2 elastic membranes, closed lid with clip-on attachment with cable retention (2 pc.) for cable tie up to 6.5 mm width for normal environment and protected outdoor
DK ZE 10
Cable retention set with 10 pieces for fixing in the bottom part of DK-cable junction boxes cable retention with cable clip up to 6.5 mm
KHR 01
Cable retentionfor cable diameter 6,5 - 14 mm set with 10 x 6 cable rentention rings 30 pieces for cable diameter 6,5 - 10 mm 30 pieces for cable diameter 10 - 14 mm
KHR 02
Cable retentionfor cable diameter 10 - 16 mm set with 10 x 6 cable rentention rings 30 pieces for cable diameter 10 - 14 mm 30 pieces for cable diameter 13 - 16 mm
DE MB 10
Assembly bracket external brackets 10 units material: thermoplastics for quick installation of cable junction boxes DE 922. and DN 20..
-
52
DK Cable Junction Boxes Cable Entry via Elastic Membranes in Bottom and Box Walls
DE 9226
Wall23
2324 24
1.5-2.5 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol box walls with 10 elastic membranes, closed, sealing range
3-14 mm, bottom with 2 elastic membranes, closed lid with clip-on attachment for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
DE 9221
Wall23
2324 24
without terminals box walls with 10 elastic membranes, closed, sealing range
3-14 mm, bottom with 2 elastic membranes, closed lid with clip-on attachment with cable retention (2 pc.) for cable tie up to 6.5 mm width for normal environment and protected outdoor
DK ZE 10
Cable retention set with 10 pieces for fixing in the bottom part of DK-cable junction boxes cable retention with cable clip up to 6.5 mm
KHR 01
Cable retentionfor cable diameter 6,5 - 14 mm set with 10 x 6 cable rentention rings 30 pieces for cable diameter 6,5 - 10 mm 30 pieces for cable diameter 10 - 14 mm
KHR 02
Cable retentionfor cable diameter 10 - 16 mm set with 10 x 6 cable rentention rings 30 pieces for cable diameter 10 - 14 mm 30 pieces for cable diameter 13 - 16 mm
DE MB 10
Assembly bracket external brackets 10 units material: thermoplastics for quick installation of cable junction boxes DE 922. and DN 20..
-
53
DK Cable Junction Boxes with Terminals for Aluminium and Copper Conductors Cable Entry via Metric Knockouts
Degree of protection up to IP 65. In the case of twisted cables, cable glands are required in principle to achieve the degree of protection IP 54.
Separate clamping units for aluminium and copper conductors
Stainless steel cover screws with quick fastening metric thread. Reducing cover xing time.
Burning behaviour:Glow wire test according to IEC 60 695-2-11: 750 C, flame-retardant, self-extinguishing
Labelling system for circuit description. Label template on the Internet at
www.hensel-electric.de - in the Downloads area.
-
54
DK Cable Junction Boxes with Terminals for Aluminium and Copper Conductors Cable Entry via Metric Knockouts
D 9041
Wall
4
24 4
1.5-2.5 mm, Cu/Alu 3~
with terminals 5-pole per polel 4 x 1.5 mm sol/f, 4 x 2.5 mm sol/f, conductors
are inserted into the screw-type terminal, terminal technology, see annex DK Cable junction boxes
included cable entry: 4 ESM 25, sealing range 9-17 mm In the case of twisted cables, cable glands are required in
principle to achieve the degree of protection IP 54. Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 250 V current carrying capacity 20 A tightening torque for terminal 0,5 Nm
98 61
98
K 9061
Wall10
106 5
1.5-4 mm, Cu/Alu 3~
with terminals 5-pole per pole 4 x 1.5 mm sol/f, 4 x 2.5 mm sol/f, 4 x 4 mm
sol/f, conductors are inserted into the screw-type terminal, terminal technology, see annex DK Cable junction boxes
included cable entry: 3 ESM 32, sealing range 9-23 mm In the case of twisted cables, cable glands are required in
principle to achieve the degree of protection IP 54. Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 400 V current carrying capacity 20 A tightening torque for terminal 0,6 Nm
139
119
70
-
55
DK Cable Junction Boxes with Terminals for Aluminium and Copper Conductors Cable Entry via Metric Knockouts
K 9351
Wall13
1315 15
6-16 mm, Cu/Alu 3~
with terminals 5-pole per polel 4 x 6 mm sol/f, 4 x 10 mm sol/f, 4 x 16 mm
sol/s/f, conductors are inserted into the screw-type terminal, terminal technology, see annex DK Cable junction boxes
included cable entry: 3 ESM 40, sealing range 17-30 mm In the case of twisted cables, cable glands are required in
principle to achieve the degree of protection IP 54. Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 76 A tightening torque for terminal 3,0 Nm
117260
210
KF 9251
Wall16
118 8
1.5-50 mm, Cu/Alu 3~
with connecting terminal 5-pole per pole 2 x 1 x 1.5-50 mm, conductors are inserted into
the screw-type terminal, terminal technology, see annex DK Cable junction boxes
included cable entry: 2 EDK 40, sealing range 11-30 mm Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 160 A tightening torque for terminal 1.5 Nm 1.5-2.5 mm
5.0 Nm 4-10 mm 12,0 Nm 16-50 mm
98
160
200
-
56
DK Cable Junction Boxes with Terminals for Aluminium and Copper Conductors Cable Entry via Metric Knockouts
KF 9501
Wall12
1217 17
1.5-50 mm, Cu/Alu 3~
with connecting terminal 5-pole per pole 2 x 1 x 1.5-50 mm, conductors are inserted into
the screw-type terminal, terminal technology, see annex DK Cable junction boxes
included cable entry: 2 EDK 40, sealing range 11-30 mm Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 160 A tightening torque for terminal 1.5 Nm 1.5-2.5 mm
5.0 Nm 4-10 mm 12,0 Nm 16-50 mm
310
210 117
K 7051
Wall20
2021 21
2.5-50 mm, Cu/Alu 3~
with terminals 5-pole per pole 4 x 2.5-50 mm, conductors are inserted into the
screw-type terminal, terminal technology, see annex DK Cable junction boxes
sealable Order cable glands, flanges and other accessories separately as
required Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 750 V current carrying capacity Cu, 150 A
Alu, 120 A tightening torque for terminal 10,0 Nm
450
300 170
-
57
DK Cable Junction Boxes with Terminals for Aluminium and Copper Conductors Cable Entry via Metric Knockouts
K 7042
Wall20
2021 21
10-95 mm Cu/Alu 3~
with terminals 4-pole per pole 2 x 10-95 mm, conductors can be inserted from
the front into the clamping unit, terminal technology, see annex DK Cable junction boxes
sealable Order cable glands, flanges and other accessories separately as
required Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 160 A tightening torque for terminal 20,0 Nm
450
300 170
K 7052
Wall20
2021 21
10-95 mm Cu/Alu 3~
with terminals 5-pole per pole 2 x 10-95 mm, conductors can be inserted from
the front into the clamping unit, terminal technology, see annex DK Cable junction boxes
sealable Order cable glands, flanges and other accessories separately as
required Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 160 A tightening torque for terminal 20,0 Nm
450
300 170
-
58
DK Cable Junction Boxes with Terminals for Aluminium and Copper Conductors Cable Entry via Metric Knockouts
K 9951
Wall20
2021 21
6-95 mm, Cu/Alu 3~
with terminals 5-pole per pole 4 x 6-95 mm, conductors are inserted into the
screw-type terminal, terminal technology, see annex DK Cable junction boxes
Order cable glands, flanges and other accessories separately as required
Reference to the preparation of aluminum conductors: 1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 490 A tightening torque for terminal 12.0 Nm 6-25 mm
22.0 Nm 35-95 mm
450
300 170
K 1204
Wall20
2021 21
16-150 mm, Cu/Alu 3~
with terminals 4-pole per pole 2 x 16-150 mm, 4 x 16-70 mm, conductors can
be inserted from the front into the clamping unit, terminal technology, see annex DK Cable junction boxes
sealable Order cable glands, flanges and other accessories separately as
required Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 250 A tightening torque for terminal 20,0 Nm
450
300 170
-
59
DK Cable Junction Boxes with Terminals for Aluminium and Copper Conductors Cable Entry via Metric Knockouts
K 1205
Wall20
2021 21
16-150 mm, Cu/Alu 3~
with terminals 5-pole per pole 2 x 16-150 mm, 4 x 16-70 mm,
conductors can be inserted from the front into the clamping unit, terminal technology, see annex DK Cable junction boxes
sealable Order cable glands, flanges and other accessories separately as
required Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 250 A tightening torque for terminal 20,0 Nm
450
300 170
K 2404
Wall20
1819 19
25-240 mm, Cu/Alu 3~
with terminals 4-pole per pole 2 x 25-185/240 mm, 4 x 25-120 mm,
conductors can be inserted from the front into the clamping unit, terminal technology, see annex DK Cable junction boxes
sealable Order cable glands, flanges and other accessories separately as
required Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 400 A tightening torque for terminal 40,0 Nm
600
300 170
-
60
DK Cable Junction Boxes with Terminals for Aluminium and Copper Conductors Cable Entry via Metric Knockouts
K 2405
Wall20
1819 19
25-240 mm, Cu/Alu 3~
with terminals 5-pole per pole 2 x 25-185/240 mm, 4 x 25-120 mm,
conductors can be inserted from the front into the clamping unit, terminal technology, see annex DK Cable junction boxes
sealable Order cable glands, flanges and other accessories separately as
required Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 400 A tightening torque for terminal 40,0 Nm
600
300 170
K 2401
Wall20
1819 19
35-240 mm, Cu/Alu 3~
with terminals 5-pole per pole 4 x 35-240 mm, conductors are inserted into the
screw-type terminal, terminal technology, see annex DK Cable junction boxes
sealable Order cable glands, flanges and other accessories separately as
required Reference to the preparation of aluminum conductors:
1. Clean the bared conductor end carefully by scraping off the oxide film, for example with a knife, (Please do not use rasps, emery paper or brushes!). 2. Immediately after removing the oxide film the conductor end is to rub in with acid and alkali free fat for example vaseline, and immediately to be connected in the terminal. 3. The prementioned processing steps are to be repeated, if the conductor was disconnected and connected again. 4. Due to the disposition to flowing of aluminum the terminals are to be re-tightened before start-up and after the first 200 operation hours.
for normal environment and protected outdoor
rated insulation voltage AC/DC 690 V current carrying capacity 850 A tightening torque for terminal 26.0 Nm 35-120 mm
55.0 Nm 150-240 mm
600
300 170
-
61
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Cable Entry via Metric Knockouts
Degree of protection IP 66 Flame retardant, self-extinguishing,
made of high-grade material:PC-GFS, glass- bre reinforced thermoplastics, impact proof
KF-Cable junction boxes comply with regulatory restrictions for buildings with requirements regarding the structural fire protection!
halogen-free, silicone-free:low toxicity, low fume development
Stainless steel cover screws with quick fastening metric thread. Reducing cover xing time.
Burning behaviour:Glow-wire test 960C according to IEC 60 695-2-11, UL Subject 94: V-0 ame-retardant, self-extinguishing
Degree of protection IP 66 using cable glands ASS.. (colour black) or cable glands ASM.. (colour grey), available as an accessory.
-
62
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Cable Entry via Metric Knockouts
KF 9025
Wall
3
13 3
1.5-2.5 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
5388
88
KF 9045
Wall
4
24 4
1.5-4 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol,
2 x 6 mm sol cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
98 61
98
KF 9065
Wall10
106 5
2.5-6 mm, Cu 3~
with terminals 5-pole per pole 4 x 2.5 mm sol, 4 x 4 mm sol, 3 x 6 mm sol,
2 x 10 mm sol cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,5 Nm
139
119
70
KF 9105
Wall14
106 6
4-10 mm, Cu 3~
with terminals 5-pole per pole 6 x 2.5 mm sol, 4 x 4 mm sol, 4 x 6 mm sol,
4 x 10 mm sol, 2 x 16 mm s cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V current carrying capacity 63 A tightening torque for terminal 2,0 Nm
82167
125
-
63
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Cable Entry via Metric Knockouts
KF 9255
Wall16
118 8
10-25 mm, Cu 3~
with terminals 5-pole per pole 6 x 10 mm sol, 4 x 16 mm s, 4 x 25 mm s,
2 x 35 mm s cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V current carrying capacity 102 A tightening torque for terminal 3,0 Nm
98
160
200
KF 9355
Wall15
1513 13
16-35 mm, Cu 3~
with terminals 5-pole per pole 6 x 16 mm s, 4 x 25 mm s, 4 x 35 mm s,
2 x 50 mm s cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V current carrying capacity 125 A tightening torque for terminal 12,0 Nm
117
260
210
KF 9505
Wall12
1217 17
16-50 mm, Cu 3~
with terminals 5-pole per pole 6 x 16 mm s, 4 x 25 mm s, 4 x 35 mm s,
4 x 50 mm s cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V current carrying capacity 150 A tightening torque for terminal 12,0 Nm
310
210 117
-
64
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Cable Entry via Metric Knockouts
KF 9020
Wall
3
13 3
without terminals cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
5388
88
KF 9040
Wall
4
24 4
without terminals cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
98 61
98
KF 9060
Wall10
106 5
without terminals cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
139
119
70
KF 9100
Wall14
106 6
without terminals cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
82167
125
KF 9250
Wall16
118 8
without terminals cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
98
160
200
-
65
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Cable Entry via Metric Knockouts
KF 9350
Wall13
1315 15
without terminals cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
117260
210
KF 9500
Wall12
1217 17
without terminals cable entry via knockouts, order ASM separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
310
210 117
-
66
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Cable Entry via Metric Knockouts
KF 5025
Wall
3
13 3
1.5-2.5 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
5388
88
KF 5045
Wall
4
24 4
1.5-4 mm, Cu 3~
with terminals 5-pole per pole 6 x 1.5 mm sol, 4 x 2.5 mm sol, 3 x 4 mm sol,
2 x 6 mm sol cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,2 Nm
98 61
98
KF 5065
Wall10
106 5
2.5-6 mm, Cu 3~
with terminals 5-pole per pole 4 x 2.5 mm sol, 4 x 4 mm sol, 3 x 6 mm sol,
2 x 10 mm sol cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V tightening torque for terminal 1,5 Nm
139
119
70
KF 5105
Wall14
106 6
4-10 mm, Cu 3~
with terminals 5-pole per pole 6 x 2.5 mm sol, 4 x 4 mm sol, 4 x 6 mm sol,
4 x 10 mm sol, 2 x 16 mm s cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V current carrying capacity 63 A tightening torque for terminal 2,0 Nm
82167
125
-
67
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Cable Entry via Metric Knockouts
KF 5255
Wall16
118 8
10-25 mm, Cu 3~
with terminals 5-pole per pole 6 x 10 mm sol, 4 x 16 mm s, 4 x 25 mm s,
2 x 35 mm s cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V current carrying capacity 102 A tightening torque for terminal 3,0 Nm
98
160
200
KF 5355
Wall15
1513 13
16-35 mm, Cu 3~
with terminals 5-pole per pole 6 x 16 mm s, 4 x 25 mm s, 4 x 35 mm s,
2 x 50 mm s cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V current carrying capacity 125 A tightening torque for terminal 12,0 Nm
117
260
210
KF 5505
Wall12
1217 17
16-50 mm, Cu 3~
with terminals 5-pole per pole 6 x 16 mm s, 4 x 25 mm s, 4 x 35 mm s,
4 x 50 mm s cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
rated insulation voltage AC/DC 690 V current carrying capacity 150 A tightening torque for terminal 12,0 Nm
310
210 117
-
68
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Cable Entry via Metric Knockouts
KF 5020
Wall
3
13 3
without terminals cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
5388
88
KF 5040
Wall
4
24 4
without terminals cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
98 61
98
KF 5060
Wall10
106 5
without terminals cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
139
119
70
KF 5100
Wall14
106 6
without terminals cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
82167
125
KF 5250
Wall16
118 8
without terminals cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
98
160
200
-
69
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Cable Entry via Metric Knockouts
KF 5350
Wall13
1315 15
without terminals cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
117260
210
KF 5500
Wall12
1217 17
without terminals cable entry via knockouts, order ASS separately
(refer to index cable entry systems) "Outdoor - harsh environment and (or) outdoor"
310
210 117
-
70
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Box Walls without Knockouts
Cable entries can be drilled individually Stainless steel cover screws with quick fastening metric thread. Reducing cover xing time.
Labelling system for circuit description. Label template on the Internet at
www.hensel-electric.de - in the Downloads area.
Burning behaviour:Glow-wire test 960 C according to IEC 60 695-2-11, UL Subject 94: V-0 ame-retardant, self-extinguishing
-
71
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Box Walls without Knockouts
KF 8020
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 20 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 2,3 mm
5388
88
KF 8040
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 20 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 2,3 mm
98 58
98
KF 8060
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 32 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 2,6 mm
139
119
70
KF 8100
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 32 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 2,8 mm
82167
125
-
72
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Box Walls without Knockouts
KF 8250
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 40 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 3 mm
98
160
200
KF 8350
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 50 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 3 mm
117260
210
KF 8500
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 50 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 3 mm
310
210 117
-
73
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Box Walls without Knockouts
KF 4020
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 20 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 2,3 mm
5388
88
KF 4040
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 20 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 2,3 mm
98 58
98
KF 4060
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 32 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 2,6 mm
139
119
70
KF 4100
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 32 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 2,8 mm
82167
125
-
74
DK Cable Junction Boxes Weatherproof, for Outdoor Installation Box Walls without Knockouts
KF 4250
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 40 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 3 mm
98
160
200
KF 4350
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 50 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 3 mm
117260
210
KF 4500
without terminals box walls without knockouts wall surface can be drilled individually for cable entry max. M 50 "Outdoor - harsh environment and (or) outdoor"
wall thickness of the bottom part 3 mm
310
210 117
-
75
Stainless steel cover screws with quick fastening metric thread. Reducing cover xing time.
Labelling system for circuit description. Label template on the Internet at
www.hensel-electric.de - in the Downloads area.
Burning behaviour:Glow-wire test 960 C according to IEC 60 695-2-11, UL Subject 94: V-0 ame-retardant, self-extinguishing
DK Cable Junction Boxes Weatherproof, for Outdoor InstallationApproved for United States and Canada (UL/CSA)Box Walls without Knockouts
Cable junction boxes with external brackets made of stainless steel.
Cable entries can be drilled individually.
Approved for United States and Canada
-
76
DK Cable Junction Boxes Weatherproof, for Outdoor InstallationApproved for United States and Canada (UL/CSA)Box Walls without Knockouts
KF 7020
without terminals with UL/CSA approval box walls without knockouts wall surface can be drilled individually for cable entry M 20,
NPT 3/8" and NPT 1/2"
wall thickness of the bottom part 2,3 mm external brackets 2
5388
88
KF 7040
without terminals with UL/CSA approval box walls without knockouts wall surface can be drilled individually for cable entry M 20,
NPT 3/8" and NPT 1/2"
wall thickness of the bottom part 2,3 mm external brackets 2
98 58
98
KF 7060
without terminals with UL/CSA approval box walls without knockouts wall surface can be drilled individually for cable entry M 20/25/32,
NPT 3/8", NPT 1/2" and NPT 3/4"
wall thickness of the bottom part 2,6 mm external brackets 2
139
119
70
KF 7100
without terminals with UL/CSA approval box walls without knockouts wall surface can be drilled individually for cable entry M 20/25/32,
NPT 3/8", NPT 1/2", NPT 3/4" and 1"
wall thickness of the bottom part 2,8 mm external brackets 2
82167
125
-
77
DK Cable Junction Boxes Weatherproof, for Outdoor InstallationApproved for United States and Canada (UL/CSA)Box Walls without Knockouts
KF 7250
without terminals with UL/CSA approval box walls without knockouts wall surface can be drilled individually for cable entry M 20/25/32,
NPT 3/8", NPT 1/2", NPT 3/4" and 1"
wall thickness of the bottom part 3 mm external brackets 4
98
160
200
-
78
DK Cable Junction Boxes Waterproof , for Encapsulating
Cable junction boxes for encapsulating In case of re-installation or testing the sealing compound can be removed easily
Stainless steel cover screws with quick fastening metric thread. Reducing cover xing time.
Scope of application:Ground level installations
Scope of application:Pump shafts
Scope of application:Flood areas close to rivers orunprotected outdoor installations which are in close proximity to the ground
The ingress of water and formation of condensation are completely prevented.The sealing compound can be easily removed for subsequent installations or inspections.
-
79
DK Cable Junction Boxes Waterproof , for Encapsulating
Permanent waterproof
connection -
Cable junction boxes
for encapsulating
in accordance with
DIN VDE V 0606-22-100
Time and time again, electricians come across installation envi-ronments whereby the ingress of water into an enclosure must be safely excluded. Even enclo-sures which have a high degree of protection cannot guarantee this. The IP degree of protection allows the ingress of non-harmful quantities of water in the interior of an enclosure.
Under extreme environmental conditions, for example, the ac-cumulation of condensation may result in damage to the electrical installation or devices or cause these to malfunction.
Ventilation measures will often suffice to prevent harmful con-densation from forming.
In many cases, however, ventila-tion is not possible, e.g. because the cable junction boxes are in-stalled close to rivers and water could enter through the vent holes.
Which applications require waterproof connections?
Pump shafts Ground-level installation ducts
in outdoor areas
Flood areas close to rivers Unprotected outdoor instal-
lations which are in close proximity to the ground
Why is the IP degree of pro-tection alone not sufficient?
All degrees of protection al-lowed Water ingress
The accumulation of con-densation cannot always be prevented
Ventilation measures cannot be applied in all environments
The waterproof connection
Sealing the cable junction boxes with a fast setting, permanently elastic sealing compound com-pletely the ingress of water and the
excludes forming of condensation.
The sealing compound fea-tures outstanding insula-tion properties. As the com-pound is transparent, it is possible for visual inspections of the installation to be carried out at any time. The durable elastic material is self-sealing, therefore it is also easy for the electrical con-nections to b