WWW.SDCSECURITY.COM SECURITY DOOR CONTROLS
Security Door ControlsACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM 1
Communicating Bathroom PackagePre-specd so you dont have to. One part number covers it all, whether youre looking for a mortise, cylindrical, or electromagnetic locking system. Each Shared Bathroom Package is complete with everything needed to ensure privacy and coordinate emergency access to a common bathroom facility from adjoining rooms in hospitals, long term care facilities, schools and dormitories.
(2) Electrified Locking Devices (Mortise, Cylindrical or ElectroMagnetic)
(1) 1.5 Amp Power Supply with Universal Relay Module (631RFXUR1)
(2) Emergency Access Push Button Switches (CB400-B)
(1) System Activation Push Button Switch (CB400-A)
(2) Build-in Latch or Door Position Status Sensors (DPS , L)
(2) Power Transfer Hinges* *(not required for EMLocks) (PTH)
PACKAGE COMPONENTS:
MODELS
CBP-ME-78 includes Eclipse style mortise locks (Z7850LQDE)
CBP-MG-78 includes Galaxy style mortise locks Z7850LQDG)
MORTISE LOCK OPTION:
CB400-A Series
CB400-B Series
WARRANT
Y
YEAR5
CBP-CE-72 includes Eclipse style cylindrical locks (Z7250EQ)
CBP-CG-72 includes Galaxy style cylindrical locks (Z7250GQ)
CYLINDRICAL LOCK OPTION:
CBP-EM-81 includes EMLock locking devices 650lb (1581VD)
CBP-EM-71 includes EMLock locking devices 1200lb (1571VD)
CBP-EM-11 includes EMLock locking devices 1650lb (1511VD)
ELECTRO MAGNETIC OPTION:
Every Shared Bathroom Package also includes a Riser Diagram, Components List, Method of Operation and Wiring Diagram to help you determine the materials and installation costs to complete your project bid.
2017 SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM
Security Door Controls
LIT-CBP COMMUNICATING BATHROOM PACKAGE 08/17
[t] 800.413.8783 805.494.0622 [f] 866.215.3138 801 Avenida Acaso, Camarillo, CA 93012 PO Box 3670, Camarillo, CA 93011
APPLICATION
Z7850 x DPS Electrified Mortise Lock with Door Status
631RFXUR-1 1.5 Amp, 12/24 VDC Class 2 Output Power Supply w/Comm. Bath Control Module
402-B Emergency Release Button
PTH Power Transfer Hinge
1581 x DPS EMLock 650lb1571 x DPS EMLock 1200lb1511 x DPS EMLock 1650lb
Z7250 Electrified Cylindrical Lock with Latch Status
PTH Power Transfer Hinge
402-A System Activation Button
631RFXUR-1 1.5 Amp, 12/24 VDC Class 2 Output Power Supply w/Comm. Bath Control Module
402-B Emergency Release Button
402-A System Activation Button
631RFXUR-1 1.5 Amp, 12/24 VDC Class 2 Output Power Supply w/Comm. Bath Control Module
401-B Emergency Release Button
401-A System Activation Button
C NO C NO - NO C NC - NO C NC
- +
TRIG A TRIG B RELAY A RELAY B
w
DA
w
DB
J1
UR-1
PWR
PROJECT NAME:
DIST.: DWG. NO.:DRAWN BY: DATE:LOCATION.: CONTACT:
SO NO.: REVTITLE:-801 Avenida Acaso
Camarillo, CA 93012t 805.494.0622 ~ f 805.494.8861
www.sdcsecurity.com
--
--
2-Door Communicating Bath System Electrified Cylindrical Solution
- [email protected] --06/17Page 1 of 3
-
2017 Security Door Controls Printed in U.S.A
Door 1
Door 2
EMERGENCY
RELEASE
PUSHTO UNLOCK DOOR
CB402-B
(OUTSIDE DOOR 2)
CB402-A
ACTIVATION
BUTTON
SWITCH
(INSIDE)
C
N/CN/O
YEL
WHT
C
N/CN/O
YEL
WHT
BATHROOM LOCKBOTH DOORS MUST BE
CLOSED TO LOCK
LIGHT ON DOOR LOCKED
PUSH TO LOCK
EMERGENCY
RELEASE
PUSHTO UNLOCK DOOR
CB402-B
(OUTSIDE DOOR 1)
C
N/CN/O
YEL
WHT
RED
RED
LAMP
RED
RED
LAMP
ROCKER SWITCH SETTINGS:
SWITCH #1 IS ON
ALL OTHER SWITCHES OFF
WET/DRY SELECTION JUMPERS:
Both A & B set to WET
WET
DRY
RED
RED
LAMP
Method of Operation:
Both doors are normally closed and unlocked.
System Activation:
Upon entering the bathroom and closing both doors,
momentarily pressing the Activation Button will lock both
doors and turn ON the indicator lamps on the Activation
and Emergency Release Buttons, indicating the system
is active.
System Deactivation:
Operating the inside lever to retract the latch on either
door will unlock both doors and turn off all indicator
lamps. Using a key override from the outside to enter
either door will also reset the system and unlock both
doors.
Emergency Override:
Momentarily pressing either Emergency Release Button
located outside each door will immediately unlock both
doors and reset the system.
CBP-C Series System Components:
(1) 631RFXUR1 1A Power Supply w/
Comm. Bath Controller
(1) CB402-A Activation Button
(2) CB402-B Emergency Release Button
(2) Z7250EQ or Z7250GQ Electrified
Cylindrical Lock, Eclipse or Galaxy Lever
(2) PTH-4Q 4.5"x4.5" Power Transfer
Hinge
Battery
Charger
Indicator Fuse
AC Power
LED
Primary
Fuse 250V
1.5AmpBattery
Input
System Status
LED
G W B
TO 120VAC PRIMARY
VOLTAGE CONNECTION
(Remove factory installed jumper only
when fire alarm interface is used)
+
-
DC Voltage
Output
Terminals+ - C
12V
S
H
O
R
T
O
P
E
N24V
VOLTAGE
SELECT
Note:
SET TO 24VDC.
Power must be turned
off before changing
voltage jumper631RF
NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE
PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR ITS
CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN THE
WHICH THE EQUIPMENT IS INSTALLED AND OPERATED. ALL
WIRING MUST CONFORM TO NATIONAL, STATE, AND LOCAL CODES
FOR CLASS 2 FIRE PROTECTION AND CONTROL DEVICES.
22/4C
AC
Mains
(3) COND
18/4C
22/4C
18/4C
Z7250EQ/GQ
Electrified Cylindrical Lock
(Fail-Safe)
Z7250EQ/GQ
Electrified Cylindrical Lock
(Fail-Safe)
631RF
Power
Supply
x UR-1
PTH-4Q
Power
Transfer
Hinge
PTH-4Q
Power
Transfer
Hinge
CB402-A
Activation
Button
CB402-B
Emergency
Release
(Outside)
CB402-B
Emergency
Release
(Outside)
Door #1 Door #2
22/4C
C NO C NO - NO C NC - NO C NC
- +
TRIG A TRIG B RELAY A RELAY B
w
DA
w
DB
J1
UR-1
PWR
PROJECT NAME:
DIST.: DWG. NO.:DRAWN BY: DATE:LOCATION.: CONTACT:
SO NO.: REVTITLE:-801 Avenida Acaso
Camarillo, CA 93012t 805.494.0622 ~ f 805.494.8861
www.sdcsecurity.com
--
--
2-Door Communicating Bath System Electrified Mortise Solution
- [email protected] --06/17Page 2 of 3
-
2017 Security Door Controls Printed in U.S.A
Door 1
Door 2
EMERGENCY
RELEASE
PUSHTO UNLOCK DOOR
CB402-B
(OUTSIDE DOOR 2)
CB402-A
ACTIVATION
BUTTON
SWITCH
(INSIDE)
C
N/CN/O
YEL
WHT
C
N/CN/O
YEL
WHT
BATHROOM LOCKBOTH DOORS MUST BE
CLOSED TO LOCK
LIGHT ON DOOR LOCKED
PUSH TO LOCK
EMERGENCY
RELEASE
PUSHTO UNLOCK DOOR
CB402-B
(OUTSIDE DOOR 1)
C
N/CN/O
YEL
WHT
RED
RED
LAMP
RED
RED
LAMP
ROCKER SWITCH SETTINGS:
SWITCH #1 IS ON
ALL OTHER SWITCHES OFF
WET/DRY SELECTION JUMPERS:
Both A & B set to WET
WET
DRY
RED
RED
LAMP
Method of Operation:
Both doors are normally closed and unlocked.
System Activation:
Upon entering the bathroom and closing both doors,
momentarily pressing the Activation Button will lock both
doors and turn ON the indicator lamps on the Activation
and Emergency Release Buttons, indicating the system
is active.
System Deactivation:
Operating the inside lever & opening either door will
unlock both doors and turn off all indicator lamps. Using
a key override from the outside to enter either door will
also reset the system and unlock both doors.
Emergency Override:
Momentarily pressing either Emergency Release Button
located outside each door will immediately unlock both
doors and reset the system.
CBP-M Series System Components:
(1) 631RFXUR1 1A Power Supply w/
Comm. Bath Controller
(1) CB402-A Activation Button
(2) CB402-B Emergency Release Button
(2) Z7850LQDE or Z7850LQDG
Electrified Mortise Lock w/ DPS, Eclipse or
Galaxy Lever
(2) PTH-4Q 4.5"x4.5" Power Transfer
Hinge
Battery
Charger
Indicator Fuse
AC Power
LED
Primary
Fuse 250V
1.5AmpBattery
Input
System Status
LED
G W B
TO 120VAC PRIMARY
VOLTAGE CONNECTION
(Remove factory installed jumper only
when fire alarm interface is used)
+
-
DC Voltage
Output
Terminals+ - C
12V
S
H
O
R
T
O
P
E
N24V
VOLTAGE
SELECT