01-243 TW Mechanical Drawings

download 01-243 TW Mechanical Drawings

of 4

Transcript of 01-243 TW Mechanical Drawings

  • 8/13/2019 01-243 TW Mechanical Drawings

    1/4

    SECTI O N B- B

    SECTI O N A - ASpecial Cut to SuitTank Inlet - Straight,

    2

    2

    2Puddle Flange 615 from Socket EndFlanged Spigot Pipe 1150 Long with Welded

    90 d Short Radius Bend Standard

    Qty. Remarks

    F langed Bellm outh S tand ard

    Standardelled Spigot Pipe 1000 Long

    27.550

    R ESER V O I RC O M PA R TM EN T

    NUMBER 1

    R ESER V O I RC O M PA R TM EN T

    NUMBER 2

    Treated WaterWet Well

    TR EATED W ATER PUMP STATION

    Treated Water Storage Tank

    500 LitreAccumulator Vessel

    Service WaterBooster Pumps

    AdministrationRoom

    Pump Room

    PLAN @ EL. 22.16

    S T A N D A R D D E S I G N SP R O G R A M

    MINISTRY OF MUNICIPALITIESP U B L I C W O R K S

    General Notes1. All dimensions in millimeters and all levels in

    meters (GTS) unless shown otherwise.

    Current Issue Information

    TA

    AB

    2

    TA

    GENERAL ARRANGEMENT

    1:100

    TREATED WATER PUMPING STATIONZUBEDIAH

    MWH UoB CONSULTING ENGINEERING BUREAU

    WASSIT

    1000 m3/hr

    ZUBEDIAH

    A1

    2 01-243-5000

    CP1 516654.924 362 4969.785CP2 515883.917 362 2755.221

    Sheet Notes

    Abbreviations

    PoDa

    Us

    F

    4

    SE C T ION A-A

    Treated WaterPumps

    Pump Room

    ElectricalRoom

    Treated WaterPumping Station

    W e t W e l l

    5

    73

    15870

    775

    35100

    A

    A

    Electrical Room

    To ElevatedStorage Tank

    Max. Operating WaterLevel 21.2

    Min. Operating WaterLevel 16.2

    Low HookEl. 14.50

    0m 5 m 10 m

    30,000 Litre Surge TankSee Drawing 01 243 5003For Surge Tank Details

    Treated WaterPumps

    O

    FSL 28.15

    150 NB DI Service Water Network Pipe

    Pipe Thimble (Typ 2)-905

    Te n d e r S ta g e

    Bridge Crane2.0 tonne Traveling

    28.03.06

    DETAILC-302 C-302

    STANDARD DETAILS ARE LOCATED ON 01-203-5000

    73

    37

    ABAH

    STANDARD DETAIL IDENTIFICATION

    DETAIL NUMBER

    Chemical Doser

    Post ChlorinationDosing Chamber

    03.04.06 A Revised SW piping Low Hook El

    700 NB DI InletFrom Chlorine Contact Tank(Typ 2)

    700 NB DIEnd Fitting (Typ 2)

    700 NB DI InletFrom Chlorine Contact Tank(Typ 2)

    500 NB DIDischarge Header

    2 Sealed plant access coverto suite 900x900 clear opening.Refer to Plant Access Cover andFrame standard detail onDrawing 01 299 8010

    2 Sealed plant access coverto suite 1200x1700 clear opening.Refer to Plant Access Cover andFrame standard detail onDrawing 01 299 8010

    EL = ElevationNB = Nominal BoreFSL = Finished Structural LevelF.F. EL = Finished Floor Level

    F.F. EL 22.16

    EL 16.00

    EL 14.50

    2250

    750 x 750Sealed Hatch

    Inv EL 16.80

    7

    800x800UnseatingPenstock

    High HookEl 25.57

    579

    90 NB PE100 Domestic Water

    TA AB Tender Stage9.04.06

    P L A N

  • 8/13/2019 01-243 TW Mechanical Drawings

    2/4

  • 8/13/2019 01-243 TW Mechanical Drawings

    3/4

    S E C T I O N B -B

    27.550

    S T A N D A R D D E S I G N SP R O G R A M

    MINISTRY OF MUNICIPALITIESP U B L I C W O R K S

    General Notes1. All dimensions in millimeters and all levels in

    meters (GTS) unless shown otherwise.

    Current Issue Information

    28.03.06

    01-243-5002 2

    A1

    ZUBEDIAH

    1000 m3/hr

    WASSIT

    MWH UoB CONSULTING ENGINEERING BUREAU

    CP1 516654.924 3624 969.785CP2 515883.917 362 2755.221

    Sheet Notes

    Abbreviations

    ZUBEDIAHTREATED WATER PUMPING STATION

    PoDa

    Us

    F

    4

    Pu mp H o u se

    TW.CRN-60.1000

    Maximum Operat ing Water Level 21.2

    Minimum Operating Water Level 16.2

    M-210

    M - 1 0 9

    M-804

    243-04

    EL 16.00

    EL 14.50

    58

    5

    60-V-05

    243-0760-V-06

    243-03243-02

    243-01

    Roof Hatch (Above Each Pump)

    Intake for ServiceWater Foot Valve EL 15.50

    IE 16.20

    243-05

    60-SDG-01

    SECTION

    1 : 301 m 2 m

    C 22.73LC 22.76L

    SECTION A-A

    O

    579

    FSL 28.15

    Service WaterSuct ion Piping

    243-42

    243-43

    Pipe SupportPlinth

    ElectricalRoom

    P u m pRoom 2.0 tonne TravelingBridge Crane

    5 0 N B A i r V acu u mAir Release Valve (Typ)

    300 NB DI

    500 NB DI

    M-135

    150 NB DI ServiceWater Suct ion Piping

    Te n d e r S ta g e

    1. See drawing 01-203-5000 for standardmechanical details.

    TW P-6 0 . 1 0 1 0Treated Water Pump

    EL = ElevationFSL = Finished Structural LevelIE = Invert Elevat ion

    FF 22.16

    1025

    2. Indicates dimension to be specified by pumpmanufacturer.

    3

    Vertical Pump SupportPlinth (Typ 4)

    ABAH

    DETAILC-302 C-302

    STANDARD DETAIL IDENTIFICATION

    DETAIL NUMBER

    STANDARD DETAILS ARE LOCATED ON 01-203-5000

    2. Dimensions as recommended by pumpmanufacturer.

    XXX

    XXX

    60-V-04Footvalve

    No2

    (Note 2)Low HookEl 14.50

    M-105

    2250

    50 NB PVCA i r V acu u m A i rRelease Valve VentPiping to Wet Wel l

    60-AR-01

    (At base of60-AR-01)

    60-V-95

    TWSTC ompar tmen t N o . 1

    450 x 450 Opening ThroughFloor For Valve Access

    TW.SP-60.1001Sa m p l e Pu m p(Contractor to pipe from ServiceWater suction pipe to sample pumpand from sample pump discharge to DP11.)

    TA AB

    02.04.06 A Revision to SW and Sample Pump

    243-06

    750 X 750Sealed Hatch

    243-40

    243-41

    60-V-85

    High HookElevat ion 25.57

    800 x 800 UnseatingPenstock

    OverheadPipe Support(Typ 8 places)

    19.04.06 TA 2A AB Tender Stage

  • 8/13/2019 01-243 TW Mechanical Drawings