    6Managing Alarms of the GGSN9811About This Chapter

    This functionis used to detect the hardware or software fault during the running of the

    GGSN9811. The information concerning the detected fault is displayed. The information is

    transferred tothe alarm box through the convert management system. Then, the alarm box sends

    the visual andaudible signals to inform the maintenance personnel of the fault.

    6.1 Related Concepts

    This part describes the concepts of the alarm type, alarm severity level, alarm time, and alarm

    box concerning the alarm management.

    6.2 BrowsingAlarmsThe Browse Alarmwindow displays the fault alarm and the event alarm reported in the system.

    6.3 QueryingAlarm Logs

    The system can display the information of the history alarm that meets the querying

    requirements. Thus, you can know the historical running state of the device. After the command

    to query the alarm log is issued, the real-time alarm can be automatically added in the query

    alarm log window.

    6.4 Saving Alarms

    The alarm management of the local maintenance terminal (LMT) provides the functions of

    saving all results and selected results.

    6.5 Printing Alarm InformationThis part describes how to print the alarm information on the local maintenance terminal (LMT).

    The alarm information can be saved as a file of which the suffix is .prnby selecting Print To

    Filein the Printdialog box.

    6.6 Processing An Alarm

    This part describes how to process the single alarm and modify the alarm configuration

    information that is pre-determined by the system.

    6.7 Managing the Convert Management System

    The convert management system runs on the computer where the local maintenance terminal

    (LMT) is installed. The computer is connected to the alarm box through the serial port. The

    convert management system can transfer the alarm commands and the alarm information

    reported from the back administration module (BAM) to the alarm box. Thus, the alarm box can

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-1

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    2/30

    send the visual and audible signals. In this manner, you can manage the monitoring of the alarm

    box.

    6.8 Operating the Alarm Box

    The GGSN9811 adopts the universal alarm box of Huawei. When an alarm is generated, the

    alarm box sends the visual and audible signals to inform the maintenance personnel of the fault.

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-2 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    3/30

    6.1 Related Concepts

    This part describes the concepts of the alarm type, alarm severity level, alarm time, and alarm

    box concerning the alarm management.

    6.1.1 Alarm Types

    The alarms contain event alarms and fault alarms (active alarms and cleared alarms).

    6.1.2 Alarm Severity Levels

    The alarm severity level is used to identify how serious the alarm is. The alarm severity level

    can be critical, major, minor, and warning.

    6.1.3 Categories of Alarm Events

    The event alarms can be triggered by the following: power system, environment system,

    signaling system, trunk system, hardware system, software system, running system,

    communication system, service quality, and processing error.

    6.1.4 Alarm Box

    The GGSN9811 uses the universal alarm box of Huawei Technologies Co., Ltd (hereinafter

    referred to as Huawei).

    6.1.1 Alarm Types

    The alarms contain event alarms and fault alarms (active alarms and cleared alarms).

    Fault Alarms and Event Alarms

    l

    Fault alarmsThe fault alarm is caused by hardware fault such as board fault. The fault alarm can be

    cleared after the hardware fault is rectified. In this case, the system reports the cleared alarm

    notifying that the fault is rectified. Each fault alarm corresponds to one cleared alarm. The

    severity level of the fault alarm is higher than that of the event alarm.

    l Event alarms

    The event alarm is an occasional alarm during the running of the device. It indicates that

    the system is abnormal at the moment, for example, path congestion. Some event alarms

    are reported periodically. After the event alarm is cleared, the cleared alarm does not occur.

    Active Alarms and Cleared Alarms

    The active alarm and the cleared alarm are fault alarms.

    l Cleared alarms

    The fault alarm can be cleared after the hardware fault is rectified. In this case, the system

    reports the cleared alarm notifying that the fault is rectified.

    l Active alarms

    The active alarm refers to the fault alarm that is not cleared.

    6.1.2 Alarm Severity Levels

    The alarm severity level is used to identify how serious the alarm is. The alarm severity levelcan be critical, major, minor, and warning.

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-3

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    4/30

    Table 6-1lists the definitions of the alarm severity levels and the handling measures.

    Table 6-1Definitions of the alarm severity levels and the handling measures

    Alarm Severity Level Definition Remark

    Critical The critical alarm

    indicates that the fault

    affects the system

    service. Therefore,

    you must handle the

    alarm immediately

    even though the alarm

    occurs during non-

    working hours. For

    example, if an alarm

    occurs regarding theunavailability of the

    device or the

    resource, take

    immediate measures

    to clear the alarm.

    This alarm must be cleared immediately.

    Otherwise, the system breaks down.

    Major The major alarm

    affects the service

    quality. You must

    handle the alarm

    during working

    hours, for example,the alarm regarding

    the degraded service

    quality or unavailable

    resources. Otherwise,

    some important

    functions cannot be

    realized. Therefore,

    take immediate

    measures to clear the

    alarm.

    This alarm must be cleared immediately.

    Otherwise, some important functions

    cannot be realized.

    Minor The minor alarm doesnot affect the service

    quality. To avoid

    severe damage,

    handle the alarm

    properly.

    The minor alarm can remind themaintenance personnel of locating the

    alarm cause and eliminating the hidden

    troubles.

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-4 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    5/30

    Alarm Severity Level Definition Remark

    Warning The warning alarm

    can indicate the

    potential faults that

    may affect services.

    Take appropriate

    measures to handle

    the alarm.

    The warning alarm requires only the

    general knowledge of the running state

    of the device.

    6.1.3 Categories of Alarm Events

    The event alarms can be triggered by the following: power system, environment system,

    signaling system, trunk system, hardware system, software system, running system,

    communication system, service quality, and processing error.

    l Power system alarms concern the power system.

    l Environment system alarms concern the environment of the equipment room such as

    temperature, humidity, and access control.

    l Signaling system: alarms concern the signaling system.

    l Trunk system alarms concern the trunk circuit or trunk board.

    l Hardware system alarms concern the hardware such as the clock and CPU.

    l Software system alarms concern the software.

    l Running system alarms concern the running system.

    l Communication system alarms concern the communication system.

    l Service quality alarms concern the service quality.

    l Processing errors concern alarms caused by other abnormalities.

    6.1.4 Alarm Box

    The GGSN9811 uses the universal alarm box of Huawei Technologies Co., Ltd (hereinafter

    referred to as Huawei).

    Appearance of the Alarm Box

    The GGSN9811 uses the universal alarm box of Huawei. Figure 6-1shows the appearance of

    the alarm box.

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-5

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    6/30

    Figure 6-1Alarm Box

    Functions of the Alarm Box

    The alarm box reports only those alarms that reach the threshold and are not shielded.

    When the fault alarm occurs, the alarm box sounds. When the fault alarm is cleared, the sound

    stops. You can manually mute the alarm box on the local maintenance terminal (LMT).

    The alarm box is populated with four alarm indicators that correspond to four severity levels.

    When the alarms of the same severity level occur, the related indicator flashes. When all those

    alarms are cleared, the indicator is constantly on. You can manually switch off the indicator on

    the LMT.

    Meaning of Alarm Indicators

    The alarm indicators with different colors represent different severity levels.

    l The red indicator represents critical alarms.

    l The orange indicator represents major alarms.

    l The yellow indicator represents minor alarms.

    l The green indicator represents warning alarms.

    6.2 Browsing Alarms

    The Browse Alarmwindow displays the fault alarm and the event alarm reported in the system.

    Prerequisite

    l The local maintenance terminal (LMT) is started.

    l The user logs in to the GGSN9811.

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-6 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    7/30

    Context

    The record of the reported alarm contains Serial No., Alarm Name, Alarm Severity, Raised/

    Clear Time, Alarm ID, Event Type, Module ID, Location Info, Alarm Type, and Office

    Name. You can get a general knowledge of the fault alarm and event alarm reported in the system

    by browsing the Browse Alarmwindow, and thus knowing the running state of the system.

    On Local Maintenance Terminal, you can browse the Browse Alarmwindow in the following

    ways.

    Procedure

    l Choose Fault Management > Browse Alarm.

    l Click the shortcut icon in the toolbar.

    l Double-click the system icon in the taskbar.

    lRight-click the system icon in the taskbar. Then, choose Browse Alarm.

    ----End

    Result

    The Browse Alarmwindow is displayed. In this window, Faultand Eventare included. Refer

    to Figure 6-2.

    Figure 6-2Alarm Browsewindow

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-7

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    8/30

    NOTE

    When the LMT is started, the system icon is displayed in the taskbar. In addition, the alarm prompt

    blinks.

    6.3 Querying Alarm Logs

    The system can display the information of the history alarm that meets the querying

    requirements. Thus, you can know the historical running state of the device. After the command

    to query the alarm log is issued, the real-time alarm can be automatically added in the query

    alarm log window.

    Prerequisite

    l The local maintenance terminal (LMT) is started.

    l The user logs in to the GGSN9811.

    Context

    The alarm log to be queried is determined by the following such as Alarm Type, Alarm

    Severity, Alarm Time, Return Amount, Alarm ID, and Serial No..

    The returned information includes Alarm Name, Alarm Severity, Raised/Clear Time,

    Location Info, Event Type, and Alarm Type.

    You can query the alarm log in two ways.

    Procedure

    l Through the menu

    1. In Local Maintenance Terminal GGSN9811, choose Fault Management > Query

    Alarm Log. Alternatively, click shortcut icon . The Query Alarm Logdialog box

    is displayed. Refer to Figure 6-3.

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-8 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    9/30

    Figure 6-3Querying Alarm Logs (General Option)

    2. Choose Detailed Optionand Physical Optionrespectively in the dialog box to set

    the query conditions. Figure 6-4and Figure 6-5shows the query items that can be

    set in Detailed Optionand Physical Option.

    Figure 6-4Querying Alarm Logs (Detailed Option)

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-9

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    10/30

    Figure 6-5Querying Alarm Logs (Physical Option)

    3. Click OK. The system displays the query result of the alarm log. Refer to Figure

    6-6.

    Figure 6-6Query alarm log

    l Through MML commands

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-10 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    11/30

    1. Run LST ALMLOGin the man machine language (MML) command lines to query

    the alarm logs.

    ----End

    6.4 Saving Alarms

    The alarm management of the local maintenance terminal (LMT) provides the functions of

    saving all results and selected results.

    Prerequisite

    l The LMT is started.

    l The user logs in to the GGSN9811.

    l The Browse Alarmwindow or Query Alarm Logwindow is displayed.

    Context

    You can query the reported alarm in the system through the Browse Alarmwindow or Query

    Alarm Logwindow. The available alarm information can be saved in the following files:

    l CSV file (The default format. The suffix is csv)

    l HTML file (with suffix as htm)

    l Text file (with suffix as txt)

    Procedure

    Step 1 Choose the alarms to be saved in the query result of the alarm logs in the Browse Alarmwindow.

    Step 2 Right-click, and then choose shortcut menu Save Selected Alarms...to save the selected alarms.Alternatively, choose shortcut menu Save All Alarms...to save all alarms.

    Then, the Savedialog box is displayed. Refer to Figure 6-7.

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-11

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    12/30

    Figure 6-7Savedialog box

    Step 3 In the dialog box, choose the files to be saved by browsing the alarms or enter the file names.

    Step 4 Click Save.

    ----End

    6.5 Printing Alarm Information

    This part describes how to print the alarm information on the local maintenance terminal (LMT).

    The alarm information can be saved as a file of which the suffix is .prnby selecting Print To

    Filein the Printdialog box.

    6.5.1 Printing Realtime Alarm Information

    This part describes how to print the realtime alarm information.

    6.5.2 Printing Information of Generated AlarmsThis part describes how to print the information of generated alarms.

    6.5.1 Printing Realtime Alarm Information

    This part describes how to print the realtime alarm information.

    Prerequisite

    l The local maintenance terminal (LMT) is started.

    l The user logs in to the GGSN9811.

    l The Browse Alarmwindow or Query Alarm Logwindow is displayed.

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-12 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    13/30

    Context

    The alarm information can be printed on a piece of paper or saved as an electrical form.

    Procedure

    Step 1 In the LMT window, click or choose Fault Management> Alarm Realtime Print.... Then,the Printdialog box is displayed. Refer to Figure 6-8.

    Figure 6-8Printdialog box

    Step 2 Click Printto print the information of newly generated alarms.

    Step 3 In the Printdialog box, select Print To File, and then click Print. The Print To Filedialogbox is displayed. Refer to Figure 6-9.

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-13

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    14/30

    Figure 6-9Print To Filedialog box

    Step 4 In the dialog box, choose the files to be saved by browsing the files or enter a new file name.

    Step 5 Click OK. The information of the newly generated alarms is saved to the file in real time.

    ----End

    6.5.2 Printing Information of Generated Alarms

    This part describes how to print the information of generated alarms.

    Prerequisite

    l The local maintenance terminal (LMT) is started.

    l The user logs in to the GGSN9811.

    l The Browse Alarmwindow or Query Alarm Logwindow is displayed.

    Procedure

    Step 1 Choose the alarms to be saved in the Browse Alarmor Query Alarm Logwindow in the LocalMaintenance Terminal GGSN9811.

    Step 2 Right-click, and then choose shortcut menu Print Selected Alarms...to print the selectedalarms. Alternatively, choose shortcut menu Print All Alarms...to print all alarms.

    Then, the Printdialog box is displayed. Refer to Figure 6-8.

    Step 3 Click Print.

    Step 4 Alternatively, select Print To Filein the Printdialog box. Then, click Print.

    Then, the Print To Filedialog box is displayed. Refer to Figure 6-9.

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-14 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    15/30

    Step 5 In the dialog box, choose the files to be saved by browsing the files or enter a new file name.

    Step 6 Click OKto save the alarm information. Shut down the Print To Fileand Printdialog boxes.

    ----End

    6.6 Processing An Alarm

    This part describes how to process the single alarm and modify the alarm configuration

    information that is pre-determined by the system.

    6.6.1 Clearing Alarms Manually

    This part describes how to manually clear the fault alarms that exist in the system.

    6.6.2 Clearing Recovery Alarms

    This part describes how to clear the recovery alarms. This function is used to clear the

    information of the recovery alarms in Faultin the Browse Alarmwindow to reduce theunnecessary information, which facilitates the alarm browsing, fault analysis and locating.

    6.6.3 Querying Alarm Information

    This part describes how to query the alarm records displayed in the Browse Alarmwindow or

    the Query Alarm Logwindow.

    6.6.4 Querying More Alarm Details

    This part describes how to query more details in alarm records displayed in the Browse

    Alarmwindow or the Query Alarm Logwindow.

    6.6.5 Querying Alarm Configuration Information

    You can query the configuration information of an alarm by setting the querying conditions such

    as Alarm ID, Alarm Name, Alarm Type, Alarm Severity, Shielded Flag, To Alarm BoxFlag, and Modification Flag.

    6.6.6 Modifying Alarm Configuration Information

    This part describes how to modify the configuration information (Alarm Severity, Shield

    Flag, and ToAlarm Box Flag) of an alarm.

    6.6.7 Restoring Alarm Configuration Information

    This part describes how to restore the configuration information of an alarm to the factory default

    values.

    6.6.8 Refreshing Alarm Information

    This part describes how to refresh the alarm information.

    6.6.1 Clearing Alarms Manually

    This part describes how to manually clear the fault alarms that exist in the system.

    Prerequisite

    The Browse Alarmwindow is displayed on the local maintenance terminal (LMT).

    Context

    The cleared alarms are not prompted or do not exist as activity alarms.

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-15

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    16/30

    Procedure

    Step 1 Select the alarms to be cleared in Faultin the Browse Alarmwindow on the LMT.

    NOTE

    You can select multiple alarms to be cleared manually by using Ctrlor Shift.

    Step 2 Right-click, and then choose Manually Recover Alarm. Alternatively, press Ctrl+Deletetomanually clear the selected alarms.

    ----End

    6.6.2 Clearing Recovery Alarms

    This part describes how to clear the recovery alarms. This function is used to clear the

    information of the recovery alarms in Faultin the Browse Alarmwindow to reduce the

    unnecessary information, which facilitates the alarm browsing, fault analysis and locating.

    Prerequisite

    The Browse Alarmwindow is displayed on the local maintenance terminal (LMT).

    Procedure

    Right-click in Faultin the Browse Alarmwindow, and then choose Clear All Recovery

    Alarms.

    ----End

    6.6.3 Querying Alarm InformationThis part describes how to query the alarm records displayed in the Browse Alarmwindow or

    the Query Alarm Logwindow.

    Prerequisite

    l The local maintenance terminal (LMT) is started.

    l The user logs in to the GGSN9811.

    l The Browse Alarmwindow or the Query Alarm Logwindow is displayed.

    ContextThe alarm details include Serial No., Alarm Name, Alarm Severity, Raised/Clear Time,

    Location Info, Alarm ID, Module ID, Event Type, Alarm Type, Cleared Type, and Office

    Name.

    Procedure

    Step 1 Choose an alarm record in the Browse Alarmwindow or the Query Alarm Logwindow in theLocal Maintenance Terminal GGSN9811.

    Step 2 Double-click the alarm record.

    ----End

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-16 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    17/30

    Result

    The Alarm Detailed Informationdialog box is displayed. Refer to Figure 6-10.

    Figure 6-10Alarm Detailed Information

    6.6.4 Querying More Alarm Details

    This part describes how to query more details in alarm records displayed in the Browse

    Alarmwindow or the Query Alarm Logwindow.

    Prerequisite

    l The local maintenance terminal (LMT) is started.

    l The user logs in to the GGSN9811.

    l The Browse Alarmwindow or Query Alarm Logwindow is displayed.

    Context

    The details include alarm definition, impact on the system, automatic processing, possiblecauses, and handling suggestions. All the information is helpful in locating and rectifying the

    fault.

    Procedure

    Step 1 Choose an alarm record in the Browse Alarmwindow or the Query Alarm Logwindow in theLocal Maintenance Terminal GGSN9811.

    Step 2 Double-click the alarm record.

    Step 3 The Alarm Detailed Informationdialog box is displayed. Click Help....

    ----End

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-17

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    18/30

    Result

    The system is indexed to the LMT help to display the alarm details.

    6.6.5 Querying Alarm Configuration InformationYou can query the configuration information of an alarm by setting the querying conditions such

    as Alarm ID, Alarm Name, Alarm Type, Alarm Severity, Shielded Flag, To Alarm Box

    Flag, and ModificationFlag.

    Prerequisite

    l The local maintenance terminal (LMT) is started.

    l The user logs in to the GGSN9811.

    ContextYou can query the alarm configuration information in two ways.

    Procedure

    l Through the menu

    1. In the Local Maintenance Terminal GGSN9811 window, choose Fault

    Management > Query Alarm Configuration. The Query Alarm Configuration

    dialog box is displayed. Refer to Figure 6-11.

    Figure 6-11Query Alarm Configurationdialog box

    2. Set the query conditions in the dialog box.

    3. Click OK. The Query Alarm Configurationwindow is displayed. Refer to Figure

    6-12. Alternatively, the No matching recordprompt is displayed.

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-18 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    19/30

    Figure 6-12Query Alarm Configurationwindow

    NOTE

    If the Modification Flagin the Query Alarm Configurationdialog box is set to Modified

    or All, you can query the configuration information of the modified alarms, including Current/

    Original Alarm Severity, Current/Original Shield Flag, and Current/Original Alarm Box

    Flagin the Query Alarm Configurationwindow.

    l Through the MML command

    1. Run LST ALMCFGon the LMT to query the current and original configuration

    information of the alarm.

    ----End

    6.6.6 Modifying Alarm Configuration Information

    This part describes how to modify the configuration information (Alarm Severity, Shield

    Flag, and To Alarm Box Flag) of an alarm.

    Prerequisite

    l The local maintenance terminal (LMT) is started.

    l The user logs in to the GGSN9811.

    Context

    l Shield flag

    Shieldedindicates that the SRU does not process the alarms and the alarms cannot be

    queried.

    Unshieldedindicates that the SRU processes the alarms and the alarms can be queried.

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-19

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    20/30

    l To alarm box flag

    Reportindicates that the alarm can be reported to the alarm box, that is, the visual and

    audible alarm is reported.

    Not reportindicates that the alarm cannot be reported to the alarm box, that is, the

    visual and audible alarm is not reported.

    Procedure

    Step 1 Choose Fault Management > Query Alarm Configurationin the Local MaintenanceTerminal GGSN9811 window.

    Step 2 Set the query conditions in the Query Alarm Configurationdialog box. Then, click OK.

    Step 3 Select an alarm record to be modified in the Query Alarm Configurationwindow displayed.Right-click, and then select Modify Alarm Configuration.... The Modify Alarm

    Configurationdialog box is displayed. Refer to Figure 6-13.

    Figure 6-13Modify Alarm Configurationwindow

    Step 4 Modify Alarm Severity, Shield Flag, and To Alarm Box Flagin the dialog box. Then, clickOK. The modified Query Alarm Configurationwindow is displayed.

    ----End

    6.6.7 Restoring Alarm Configuration InformationThis part describes how to restore the configuration information of an alarm to the factory default

    values.

    Prerequisite

    l The local maintenance terminal (LMT) is started.

    l The user logs in to the GGSN9811.

    Context

    You can restore the alarm configuration information in two ways.

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-20 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    21/30

    Procedure

    l Through the menu

    1. Choose Fault Management> Query Alarm Configurationin the Local

    Maintenance Terminal GGSN9811 window.

    2. Set the query conditions in the Query Alarm Configurationdialog box. Then, click

    OK.

    3. Select an alarm record to be restored in the Query Alarm Configurationwindow

    displayed. Right-click, and then select Restore Alarm Configuration.

    4. Click Yes. Then, the system displays the Query Alarm Configurationwindow. Click

    Noto cancel the restoration.

    l Throughthe MML command

    1. RST ALMCFGon the LMT to restore the alarm configuration information.

    ----End

    6.6.8 Refreshing Alarm Information

    This part describes how to refresh the alarm information.

    Prerequisite

    l The local maintenance terminal (LMT) is started.

    l The user logs in to the GGSN9811.

    l The Browse Alarmwindow or Query Alarm Logwindow is displayed.

    Procedure

    Step 1 Select one or more alarm records in the Browse Alarmwindow or the Query Alarm Logwindow in the Local Maintenance Terminal GGSN9811.

    Step 2 Right-click, and then select Manually Refreshto get the latest alarm information from the SRU.

    ----End

    6.7 Managing the Convert Management System

    The convert management system runs on the computer where the local maintenance terminal

    (LMT) is installed. The computer is connected to the alarm box through the serial port. The

    convert management system can transfer the alarm commands and the alarm information

    reported from the back administration module (BAM) to the alarm box. Thus, the alarm box can

    send the visual and audible signals. In this manner, you can manage the monitoring of the alarm

    box.

    6.7.1 Starting the Convert Management System

    This part describes how to start the convert management system of the local maintenance

    terminal (LMT) on the computer that is connected to the alarm box.

    6.7.2 Configuring Alarm Transfer Parameters

    This part describes how to configure the alarm transfer parameters.

    6.7.3 Saving Printouts

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-21

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    22/30

    This part describes how to save the printouts. The printouts can help you analyze the running

    status of the convert management system.

    6.7.4 Exiting from the Convert Management System

    This part describes how to exit from the convert management system. When the alarm box is

    not used to send visual and audible signals, you can exit from the convert management systemon the computer that is connected to the alarm box.

    6.7.1 Starting the Convert Management System

    This part describes how to start the convert management system of the local maintenance

    terminal (LMT) on the computer that is connected to the alarm box.

    Prerequisite

    l The LMT is connected to the GGSN9811.

    l The computer where the LMT is installed is connected to the alarm box through the serial

    port.

    Procedure

    Choose start > Programs > HUAWEI Local Maintenance Terminal > Convert

    Management System.

    ----End

    6.7.2 Configuring Alarm Transfer Parameters

    This part describes how to configure the alarm transfer parameters.

    Prerequisite

    l The convert management system of the local maintenance terminal (LMT) is started.

    l The communication between the LMT and the back administration module (BAM) is

    normal.

    l The communication between the LMT and the alarm box is normal.

    Procedure

    Step 1 Double-click in the status bar to display the Convert Management Systeminterface. Notethat the icon is when the communication on the serial port is abnormal.

    Step 2 Choose Operate> Configurationor click .

    Step 3 The Configurationdialog box is displayed. Refer to Figure 6-14. Configure the alarm transferparameters.

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-22 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    23/30

    Figure 6-14Alarm convert configuration

    Step 4 Configure the alarm transfer parameters in the Configurationdialog box displayed. Refer toTable 6-2.

    Table 6-2Configuring alarm transfer parameters

    Field Name Description

    Host IP Specifies the IP address of the SRU

    connected to the convert management

    system. The default value is 127.0.0.1.

    COM port Specifies the port of the computer where

    the LMT is installed. The convert

    management system is connected to the

    alarm box through the port. The default

    COM port is COM1.

    NOTE

    When the alarm transfer parameters are configured successfully, the configurations are recorded in the

    configuration file. The alarm transfer parameters are automatically configured according to the

    configuration file when the convert management system is started again. The available alarm transfer

    parameters can be modified through this operation.

    Step 5 Click OK. If the information similar to the following is displayed in the Convert ManagementSystemwindow, it indicates that the alarm transfer parameters are configured successfully.

    +++Begin2007-09-14 17:33:18 Prompt: COM communication exception, please check the

    connection. +++End

    ----End

    6.7.3 Saving Printouts

    This part describes howto save the printouts. The printouts can help you analyze the running

    status of the convert management system.

    Prerequisite

    l The convert management system is started and the communication is normal.

    l The alarm transfer parameters are configured.

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-23

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    24/30

    Procedure

    Step 1 Choose Operate> Saveon the menu of Convert Management System. Alternatively, click

    . In addition, you can choose Operate> Save as....

    Step 2 Enter the file name and select the save type in the Save as...dialog box.

    Step 3 Click Save.

    ----End

    6.7.4 Exiting from the Convert Management System

    This part describes how to exit from the convert management system. When the alarm box is

    not used to send visual and audible signals, you can exit from the convert management system

    on the computer that is connected to the alarm box.

    Prerequisite

    The convert management system is started.

    Procedure

    Step 1 You can exit from the convert management system through the following ways.

    l Choose Operate> Exit.

    l Click .

    l Right-click in the taskbar, and then choose Exit. Note that the icon is when the

    communication on the serial port is abnormal.

    Step 2 The Convert Management Systemdialog box is displayed. Click OK.

    ----End

    6.8 Operating the Alarm Box

    The GGSN9811 adopts the universal alarm box of Huawei. When an alarm is generated, the

    alarm box sends the visual and audible signals to inform the maintenance personnel of the fault.

    6.8.1 Connecting the Alarm Box

    The alarm box is connected to the computer where the LMT is installed through serial port

    RS232. After the parameters are configured through Convert Management System, the alarm

    box can work at normal level.

    6.8.2 Resetting the Alarm Box

    This part describes how to reset the alarm box. The alarm box can be reset only by the admin

    user, operator, administrator, and custom user granted with certain authority.

    6.8.3 Stopping the Alarm Sound

    When the alarm occurs, the alarm box sounds to inform the operator of the fault. When the alarm

    is cleared, the alarm sound stops. For the alarm that is not cleared, you can manually prevent

    the alarm box from sounding.

    6.8.4 Stopping the Alarm Indicator Manually

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-24 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    25/30

    When the alarm occurs, the alarm indicator on the alarm box flashes to inform the operator of

    the fault. When the alarm is cleared, the alarm indicator is constantly on. For the alarm that is

    not cleared, you can manually stop the alarm indicator from flashing through the local

    maintenance terminal (LMT). Then, the related indicator is constantly on.

    6.8.5 Querying the Alarm Box VersionThis part describes how to query the alarm box version.

    6.8.6 Querying the Status of the Alarm Indicator

    The operator can judge the alarm severity level through the status of the alarm indicator.

    6.8.1 Connecting the Alarm Box

    The alarm box is connected to the computer where the LMT is installed through serial port

    RS232. After the parameters are configured through Convert Management System, the alarm

    box can work at normal level.

    Prerequisite

    The idle serial port is available on the computer where the LMT is installed.

    Procedure

    Step 1 Connect the alarm box to the computer where the LMT is installed through serial port RS232by using user-supplied serial cables.

    Step 2 Choose start> Programs> HUAWEI Local Maintenance Terminal > ConvertManagement System. The Convert Management Systemis displayed. The similar

    information is as follows:+++Begin2007-09-14 17:33:39 Prompt: COM communication exception, please check the

    connection. +++End

    Step 3 Choose Operate> Configurationin the Convert Management Systemwindow. TheConfigurationdialog box is displayed. Refer to Figure 6-15.

    Figure 6-15Alarm convert configuration

    Step 4 Enter the IP address of the maintenance network port of the GGSN9811, and then choose a COMport through which the LMT is connected to the alarm box.

    Step 5 Click OK.

    ----End

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-25

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    26/30

    6.8.2 Resetting the Alarm Box

    This part describes how to reset the alarm box. The alarm box can be reset only by the admin

    user, operator, administrator, and custom user granted with certain authority.

    Prerequisite

    l The local maintenance terminal (LMT) is started.

    l The user logs in to the GGSN9811 as an operator with the operation authority.

    l The LMT is connected to the alarm box and the communication is normal.

    l The convert management system of the LMT is started and the communication is normal.

    Context

    You can reset the alarm box in two ways.

    Procedure

    l Through the menu

    1. Choose Fault Management > Alarm Box Operation> Alarm Box Control... on

    the LMT. Alternatively, click . The Alarm Box Controldialog box is displayed.

    Refer to Figure 6-16.

    Figure 6-16Alarm Box Controldialog box

    2. Select Reset Alarm Box.

    3. Click OK.

    l Through the MML command

    1. Run RST ALMBOXto reset the alarm box.

    ----End

    6.8.3 Stopping the Alarm Sound

    When the alarm occurs, the alarm box sounds to inform the operator of the fault. When the alarm

    is cleared, the alarm sound stops. For the alarm that is not cleared, you can manually preventthe alarm box from sounding.

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-26 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    27/30

    Prerequisite

    l The local maintenance terminal (LMT) is started.

    l The user logs in to the GGSN9811 as an operator with the operation authority.

    l The LMT is connected to the alarm box.

    l The convert management system is started and the communication is normal.

    Context

    When the back administration module (BAM) reports the fault alarm to the LMT, the alarm box

    sounds.

    l When the fault alarm is cleared, the alarm sound stops automatically.

    l When the fault alarm is not cleared, you can manually stop the alarm sound.

    The alarm sound can be stopped only by the admin user, operator, administrator, and custom

    user granted with certain authority.

    You can stop the alarm sound in two ways.

    Procedure

    l Through the menu

    1. Choose Fault Management > Alarm Box Operation> Alarm Box Control... on

    the LMT. Alternatively, click . The Alarm Box Controldialog box is displayed.

    2. Select Stop Alarm Sound. Refer to Figure 6-17.

    Figure 6-17Alarm Box Controldialog box

    3. Click OK.

    l Through the MML command

    1. Run STP BOXSNDto stop the alarm sound.

    ----End

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-27

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    28/30

    6.8.4 Stopping the Alarm Indicator Manually

    When the alarm occurs, the alarm indicator on the alarm box flashes to inform the operator of

    the fault. When the alarm is cleared, the alarm indicator is constantly on. For the alarm that is

    not cleared, you can manually stop the alarm indicator from flashing through the localmaintenance terminal (LMT). Then, the related indicator is constantly on.

    Prerequisite

    l The LMT is started.

    l The user logs in to the GGSN9811 as an operator with the operation authority.

    l The LMT is connected to the alarm box.

    l The convert management system is started and the communication is normal.

    Context

    When the back administration module (BAM) reports the fault alarm to the LMT, the related

    alarm indicator on the alarm box flashes.

    l When the fault alarm is cleared, the alarm indicator is constantly on.

    l When the fault alarm is not cleared, you can manually stop the indicator from flashing.

    Then, the related indicator is constantly on.

    The alarm indicator can be stopped from flashing only by the admin user, operator, administrator,

    and custom user granted with certain authority.

    You can manually stop the alarm indicator from flashing in two ways.

    Procedure

    l Through the menu

    1. Choose Fault Management > Alarm Box Operation> Alarm Box Control... on

    the LMT. Alternatively, click . The Alarm Box Controldialog box is displayed.

    2. Select Stop Alarm Status Lampand Alarm Severity. Refer to Figure 6-18.

    Figure 6-18Alarm Box Controldialog box

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide

    6-28 Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    Issue 03 (2008-04-10)

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    29/30

    3. Click OK.

    l Through the MML command

    1. Run CLR BOXLGTto stop the alarm indicator from flashing.

    ----End

    6.8.5 Querying the Alarm Box Version

    This part describes how to query the alarm box version.

    Prerequisite

    l The local maintenance terminal (LMT) is started and the user logs in to the GGSN9811.

    l The LMT is connected to the alarm box.

    l The convert management system is started and the communication is normal.

    Context

    You can query the alarm box version in two ways.

    Procedure

    l Through the menu

    1. Choose Fault Management > Alarm Box Operation> Alarm Box Version... on

    the LMT.

    2. Click OK. The Query Resultwindow disappears.

    l Through the MML command

    1. Run LST BOXVERto query the alarm box version.

    ----End

    6.8.6 Querying the Status of the Alarm Indicator

    The operator can judge the alarm severity level through the status of the alarm indicator.

    Prerequisite

    l The local maintenance terminal (LMT) is started and the user logs in to the GGSN9811.

    l The LMT is connected to the alarm box.

    l The convert management system is started and the communication is normal.

    Context

    When the back administration module (BAM) reports the fault alarm to the LMT, the related

    alarm indicator on the alarm box flashes. When multiple alarms at the same severity level occur,

    the operator cannot know how many alarms occur through the status of the indicator.

    You can query the status of the alarm indicator in two ways.

    Procedure

    l Through the menu

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide 6 Managing Alarms of the GGSN9811

    Issue 03 (2008-04-10) Huawei Proprietary and Confidential

    Copyright Huawei Technologies Co., Ltd

    6-29

  • 7/25/2019 01-06 Managing Alarms of the GGSN9811

    30/30

    1. Choose Fault Management > Alarm Box Operation> Alarm Lamp Stateon the

    LMT. The Query Resultdialog box is displayed. The numbers of the alarms at

    different severity levels are displayed in the dialog box.

    l Through the MML command

    1. Run LST BOXLGTto query the number of alarms specified by the status of the alarmindicator.

    ----End

    6 Managing Alarms of the GGSN9811

    HUAWEI GGSN9811 Gateway GPRS Support Node

    Operation Guide