01-06 Frame Configuration

download 01-06 Frame Configuration

of 6

Transcript of 01-06 Frame Configuration

  • 8/20/2019 01-06 Frame Configuration

    1/11

    UA5000

    Operation Manual - PVU Volume Contents

     

    Issue 02 (2007-03-20) Huawei Technologies Proprietary i

     

    Contents

    6 Frame Configuration .................................................................................................................6-1 

    6.1 Overview of Frames......................................................................................................................................6-2 

    6.2 Frame Configuration .......................................................... .................................................................... .......6-3 

    6.2.1 Adding a Frame....................................................................................................................................6-3 

    6.2.2 Querying the Information of a Frame .................................................................... ..............................6-4 

    6.2.3 Adding an Inter-frame Connection.......................................................................................................6-4 

    6.2.4 Querying the Information about an Inter-frame Connection................................................................6-4 

    6.2.5 Deleting an Inter-frame Connection.....................................................................................................6-5 

    6.2.6 Deleting a Frame..................................................................................................................................6-5 

    6.3 Configuration Example .................................................................... ............................................................. 6-5 

    6.3.1 Networking ........................................................ ................................................................. .................6-6 

    6.3.2 Adding the Frames ................................................................ ............................................................... 6-6 

  • 8/20/2019 01-06 Frame Configuration

    2/11

    Figures

    UA5000

    Operation Manual - PVU Volume

     

    ii Huawei Technologies Proprietary Issue 02 (2007-03-20)

     

    Figures

    Figure 6-1 Sample connection among the master, slave and extended frames...................................................6-6 

  • 8/20/2019 01-06 Frame Configuration

    3/11

    UA5000

    Operation Manual - PVU Volume Tables

     

    Issue 02 (2007-03-20) Huawei Technologies Proprietary iii

     

    Tables

    Table 6-1 Frames and backplanes.......................................................................................................................6-2 

    Table 6-2 Commands for configuring a frame....................................................................................................6-2 

  • 8/20/2019 01-06 Frame Configuration

    4/11

  • 8/20/2019 01-06 Frame Configuration

    5/11

    UA5000

    Operation Manual - PVU Volume 6 Frame Configuration

     

    Issue 02 (2007-03-20) Huawei Technologies Proprietary 6-1

     

    6 Frame ConfigurationAbout This Chapter

    The following table lists the contents of this chapter.

    Section… Describes…

    6.1 Overview of Frames  The types of the UA5000 frames and the commands for

    configuring a frame

    6.2 Frame Configuration  How to configure a frame

    6.3 Configuration Example  Example of configuring a frame

  • 8/20/2019 01-06 Frame Configuration

    6/11

    6 Frame Configuration

    UA5000

    Operation Manual - PVU Volume

     

    6-2 Huawei Technologies Proprietary Issue 02 (2007-03-20)

     

    6.1 Overview of Frames

    There are three types of the UA5000 frames. They are master frame, slave frame and extendedframe.

      A master frame can be connected with a slave frame and an extended frame to expand thesystem capacity.

      A slave frame can be connected with an extended frame to expand the system capacity.

    The slave frame needs to be added using the frame add command. The slot of the slaveframe is numbered from 0.

      An extended frame can be seen as a logical extension of the master frame or the slaveframe it connects. The slots are numbered sequentially with that of the mater frame or theslave frame.

     

    These three types of frames use different backplanes. See Table 6-1. 

    Table 6-1 Frames and backplanes

    Frame Type Backplane Type Frame Alias

    Rear-access master frame HABA MAIN_HABM_30

    Front-access master frame HABD MAIN_HAFM_30

    Rear-access master frame HABC MAIN_HABM_12

    Front-access slave frame HABE SLAVE_HAFS_32

    Front-access extended frame HABF -

    Table 6-2 lists the commands for configuring a frame.

    Table 6-2 Commands for configuring a frame

    To… Use… In…

    Add a frame frame add Global config mode

    Add an inter-frame connection frame connect Global config mode

    Delete an inter-frame connection [undo] frame connect Global config mode

    Query the setting of inter-frame

    connectiondisplay frame connect Global config mode

    Query the setting of frames display frame info Global config mode

    Delete a frame frame delete Global config mode

    Configure frame attributes frame set Global config mode

  • 8/20/2019 01-06 Frame Configuration

    7/11

    UA5000

    Operation Manual - PVU Volume 6 Frame Configuration

     

    Issue 02 (2007-03-20) Huawei Technologies Proprietary 6-3

     

    6.2 Frame Configuration

    6.2.1 Adding a Frame

    To configure a frame, you need to add it to the system first. To add a frame, use the frame add command. The frame with PVU card is the master frame, and the frame number is fixed as 0.

    For example, to add a master frame whose frame type is MAIN_HAFM_30 (H601HABD), andadd a slave frame whose frame type is SLAVE_HAFS_32 (H602HABE), do as follows:

    huawei(config)#frame add 

    { frameid }:0 

    FrameType:

    0 : MAIN_HAFM_30(H601HABD) 1 : MAIN_HAFM_6(H601HABL)

    2 : MAIN_HABM_30(H601HABA) 3 : MAIN_HAFM_30(H602HABD)

    4 : MAIN_HABM_12(H601HABC) 5 : SLAVE_HAFS_32(H601HABE)

    6 : SLAVE_HABS_32(H601HABB) 7 : SLAVE_HABS_30(H601HABA)

    8 : SLAVE_HAFS_30(H601HABD) 9 : SLAVE_HAFS_30(H602HABD)

    10 : SLAVE_HAFS_32(H602HABE) 11 : RSU_HAFS_30(H601HABD)

    12 : RSU_HABS_30(H601HABA) 13 : RSU_HAFS_6(H601HABL)

    14 : RSU_HAFS_30(H602HABD) 15 : RSP_19(HCB)

    16 : RSP_15(HDB) 17 : RSP_14(HIB)

    18 : RSP_12(HFB) 19 : RSP_10(HGB)

    20 : RSP_6A(HMB) 21 : RSP_6B(HLB)

    22 : UAM_R (HUBM) 23 : UAS_R (HUBS)

    24 : UAFM_R(HUBE) 25 : UAFS_R(HUBF)

    26 : UABM_R(HUBB) 27 : ONU60A_R(HUBO)

    28 : UAFX_R(HUBL)

    Please select frame type (0 ~ 28):0

    Frame add successfullyhuawei(config)#frame add 10 

    FrameType:

    0 : MAIN_HAFM_30(H601HABD) 1 : MAIN_HAFM_6(H601HABL)

    2 : MAIN_HABM_30(H601HABA) 3 : MAIN_HAFM_30(H602HABD)

    4 : MAIN_HABM_12(H601HABC) 5 : SLAVE_HAFS_32(H601HABE)

    6 : SLAVE_HABS_32(H601HABB) 7 : SLAVE_HABS_30(H601HABA)

    8 : SLAVE_HAFS_30(H601HABD) 9 : SLAVE_HAFS_30(H602HABD)

    10 : SLAVE_HAFS_32(H602HABE) 11 : RSU_HAFS_30(H601HABD)

    12 : RSU_HABS_30(H601HABA) 13 : RSU_HAFS_6(H601HABL)

    14 : RSU_HAFS_30(H602HABD) 15 : RSP_19(HCB)

    16 : RSP_15(HDB) 17 : RSP_14(HIB)

    18 : RSP_12(HFB) 19 : RSP_10(HGB)

    20 : RSP_6A(HMB) 21 : RSP_6B(HLB)

    22 : UAM_R (HUBM) 23 : UAS_R (HUBS)

    24 : UAFM_R(HUBE) 25 : UAFS_R(HUBF)

    26 : UABM_R(HUBB) 27 : ONU60A_R(HUBO)

    28 : UAFX_R(HUBL)

    Please select frame type (0 ~ 28):10

    Frame add successfully

    ! FAULT MAJOR 2006-12-25 22:04:14 ALARM NAME :Frame fault

    PARAMETERS :FrameID: 1

  • 8/20/2019 01-06 Frame Configuration

    8/11

    6 Frame Configuration

    UA5000

    Operation Manual - PVU Volume

     

    6-4 Huawei Technologies Proprietary Issue 02 (2007-03-20)

     

      Select correct frame type when adding a frame. Otherwise, the cards in the frame may not function

    normally.

      A slave frame is in fault state after it is added. You need to configure the inter-frame connection for the

    frame to make it work normally.

    6.2.2 Querying the Information of a Frame

    To query the information of one or all frames, use the display frame info command.

    For example, to query the information of all frames, do as follows:

    huawei(config)#display frame info 

    { desc|ts-information }:

    { info|link|connect }:info

    { |frameid }:

    Command:

    display frame info

    ----------------------------------------------------------------------------

    FrameID FrameType FrameState

    ----------------------------------------------------------------------------

    0 MAIN_HAFM_30(H601HABD) Normal

    1 RSU_HAFS_30(H602HABD) Failed

    ----------------------------------------------------------------------------

    Total: 2

    6.2.3 Adding an Inter-frame Connection

    The PVU card provides five 16 Mbit/s HWs to connect slave and extended frames. These HWs

    are numbered 16 to 20. HW 16 is for the extended frame of this master frame. HWs 17 and 18are for the slave frames and their extended frames.

    To add an inter-frame connection, use the frame connect command. In the UA5000 PVU, themaster frame is numbered 0 and the slave frames are numbered 1–8.

    For example, to add an inter-frame connection between frame 0 and frame 1, do as follows:

    huawei(config)#frame connect 

    { upframeid }:0 

    { downframeid }:1 

    Add the frame connection successfully

    huawei(config)#

    ! RECOVERY MAJOR 2006-12-25 22:04:14 ALARM NAME :Frame recovery alarmPARAMETERS :FrameID: 1 

    6.2.4 Querying the Information about an Inter-frame Connection

    To query the information about the inter-frame connection of one or all frames, use the display

    frame connect command.

    For example, to query the information about the inter-frame connections of all frames, do asfollows:

    huawei(config)#display frame connect 

    { |frameid }:

  • 8/20/2019 01-06 Frame Configuration

    9/11

    UA5000

    Operation Manual - PVU Volume 6 Frame Configuration

     

    Issue 02 (2007-03-20) Huawei Technologies Proprietary 6-5

     

    Command:

    display frame connect

    ---------------------------------------------

    Record Upper-frame Lower-frame

    ---------------------------------------------

    6.2.5 Deleting an Inter-frame Connection

    To delete an inter-frame connection, use the undo frame connect command.

    For example, to delete the link between frame 0 and frame 1, do as follows:

    huawei(config)#undo frame connect 

    { upframeid }:0 

    { downframeid }:1 

    Changing the connection between frames will interrupt services,are you sure to

    continue(y/n)[n]: y 

    Delete the frame connection successfully

    ! FAULT MAJOR 2006-12-25 22:04:14 ALARM NAME :Frame fault

    PARAMETERS :FrameID: 1

    6.2.6 Deleting a Frame

    To delete a frame, use the frame delete command.

    Before deleting a frame, you need to delete all configurations associated with the frame,

    including services, line card, environment monitor unit, and inter-frame connections.

    For example, to delete frame 1, do as follows:

    huawei(config)#frame delete 

    { frameid }:1 Are you sure to delete this frame? (y/n)[n]: y 

    Frame 1 delete successfully

    6.3 Configuration Example

    The configuration procedure is as follows:

    Step 1  Add a frame.

    Step 2  Add an inter-frame connection.

    Step 3  Add line cards.

    Step 4  Confirm the line cards.

    ----End

  • 8/20/2019 01-06 Frame Configuration

    10/11

    6 Frame Configuration

    UA5000

    Operation Manual - PVU Volume

     

    6-6 Huawei Technologies Proprietary Issue 02 (2007-03-20)

     

    6.3.1 Networking

    Figure 6-1 shows the connection between the master frame (HABD), the slave frame (HABE)and the extended frames (HABF).

    Figure 6-1 Sample connection among the master, slave and extended frames

    E1/V5

    Slave frame

    Master frame

    Extended frame of the slave frame

    Extended frame of the master frame

    HWOUT0

    HWIN

    HWINHWIN

    HWOUT1

    HWOUT2

     A

    S

    L

     A

    S

    L

    D

    S

    L

    D

    S

    L

    H

    WT

    D

    S

    L

    PSTN

    P

    V

    U

     A

    S

    L

     A

    S

    L

    D

    S

    L

    P

    V

    U

    D

    S

    L

    H

    WC

     A

    S

    L

     A

    S

    L

    D

    S

    L

    D

    S

    L

    H

    W

    T

    D

    S

    L

     A

    S

    L

     A

    S

    L

    D

    S

    L

    D

    S

    L

    H

    W

    T

    D

    S

    L

     

    6.3.2 Adding the Frames

    Step 1  Add a master frame, with the frame number of 0, and frame type of MAIN_HAFM_30(HABD).

    huawei(config)#frame add 

    { frameid }:0 

    FrameType:

    0 : MAIN_HAFM_30(H601HABD) 1 : MAIN_HAFM_6(H601HABL)

    2 : MAIN_HABM_30(H601HABA) 3 : MAIN_HAFM_30(H602HABD)

    4 : MAIN_HABM_12(H601HABC) 5 : SLAVE_HAFS_32(H601HABE)

    6 : SLAVE_HABS_32(H601HABB) 7 : SLAVE_HABS_30(H601HABA)

    8 : SLAVE_HAFS_30(H601HABD) 9 : SLAVE_HAFS_30(H602HABD)

    10 : SLAVE_HAFS_32(H602HABE) 11 : RSU_HAFS_30(H601HABD)

    12 : RSU_HABS_30(H601HABA) 13 : RSU_HAFS_6(H601HABL)

    14 : RSU_HAFS_30(H602HABD) 15 : RSP_19(HCB)

    16 : RSP_15(HDB) 17 : RSP_14(HIB)

    18 : RSP_12(HFB) 19 : RSP_10(HGB)

    20 : RSP_6A(HMB) 21 : RSP_6B(HLB)

    22 : UAM_R (HUBM) 23 : UAS_R (HUBS)

    24 : UAFM_R(HUBE) 25 : UAFS_R(HUBF)

    26 : UABM_R(HUBB) 27 : ONU60A_R(HUBO)

    28 : UAFX_R(HUBL)

    Please select frame type (0 ~ 28): 0

  • 8/20/2019 01-06 Frame Configuration

    11/11

    UA5000

    Operation Manual - PVU Volume 6 Frame Configuration

     

    Issue 02 (2007-03-20) Huawei Technologies Proprietary 6-7

     

    Frame add successfully

    You can use the display board 0 command to query the state of the card in the new frame.

    Step 2  Add a slave frame, with the frame type of SLAVE_HAFS_32 (H602HABE).

    huawei(config)#frame add 

    FrameType:

    0 : MAIN_HAFM_30(H601HABD) 1 : MAIN_HAFM_6(H601HABL)

    2 : MAIN_HABM_30(H601HABA) 3 : MAIN_HAFM_30(H602HABD)

    4 : MAIN_HABM_12(H601HABC) 5 : SLAVE_HAFS_32(H601HABE)

    6 : SLAVE_HABS_32(H601HABB) 7 : SLAVE_HABS_30(H601HABA)

    8 : SLAVE_HAFS_30(H601HABD) 9 : SLAVE_HAFS_30(H602HABD)

    10 : SLAVE_HAFS_32(H602HABE) 11 : RSU_HAFS_30(H601HABD)

    12 : RSU_HABS_30(H601HABA) 13 : RSU_HAFS_6(H601HABL)

    14 : RSU_HAFS_30(H602HABD) 15 : RSP_19(HCB)

    16 : RSP_15(HDB) 17 : RSP_14(HIB)

    18 : RSP_12(HFB) 19 : RSP_10(HGB)

    20 : RSP_6A(HMB) 21 : RSP_6B(HLB)22 : UAM_R (HUBM) 23 : UAS_R (HUBS)

    24 : UAFM_R(HUBE) 25 : UAFS_R(HUBF)

    26 : UABM_R(HUBB) 27 : ONU60A_R(HUBO)

    28 : UAFX_R(HUBL)

    Please select frame type (0 ~ 28):10

    Frame add successfully

    ! FAULT MAJOR 2006-12-25 22:04:14 ALARM NAME :Frame fault

    PARAMETERS :FrameID: 1

    Step 3  Add an inter-frame connection.

    huawei(config)#frame connect 0 1

    Add the frame connection successfully

    Step 4  Add line cards.

    Add line cards for the master, slave and extended frames according to the data planning. The

    command used is board add. Following is an example.

    huawei(config)#board add 0/14 asl 

    huawei(config)#board add 0/25 asl 

    ……

    huawei(config)#board add 1/15 asl 

    huawei(config)#board add 1/25 asl 

    Step 5  Confirm the line cards.

    huawei(config)#board confirm 0 

    huawei(config)#board confirm 1

    ----End