006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having...

26
97 Sensors LCN Sensors Perfection. ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu High-End Building Management 1992 2017 YEARS LCN

Transcript of 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having...

Page 1: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

97

Sen

so

rs

LCN Sensors

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

High-End Building Management

1992 2017YEARS

LCN

Page 2: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

98

The LCN-TS is an especially small and high precision digital temperature sensor. It has its own processor and is almost completely silent in operation. The measured data is sent through the I-Port connection to an intelligent bus module.

Description:

The temperature sensor is used for measuring the room temperature. By connecting further sensors to the LCN bus, an energy-saving and user-friendly single-room heating regulation system can be implemented which, among other things, includes control of the ventilation system.

The LCN-TS can be operated in parallel with any other group on the I-Port connection of the LCN intelligent bus modules (UPP, UPS, UP24, SH, HU, LD). The modules allow for two continuous control circuits plus 5 switch thresholds which can also be automatically controlled.During operation, measured values can be exchanged among LCN modules and differences can be calculated.

Hardware equipment:

Temperature sensor with adhesive pad

Housing for wall and ceiling assembly

Cable with plug for the I-Port connection

Note:

When positioning the sensor, care is to be taken with regard to heat ra-diating from lighting and airflow as these can effect the measured va-lue.

For more detailed information please refer to the installation instruc-tions

Prec.-temperature sensor (0,1°C) for I-Port

LCN-TS

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Page 3: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

Prec.-temperature sensor (0,1°C) for I-Port

LCN-TS

D

L

N

PE

D

L

N

PE

45

mm

25

mm

30mm11

mm

I

LCN-TS

99

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

45 mm x 25 mm

30 mm x 11 mm x 4mm

400 mm

Dimensions:

Case

Sensor (L x B x H):

Supply Cable:

(ø x H):

ceiling- or wall assemblyon 35mm wall light box

Assembly:

Circuit diagram

LCN Bus Module

Technical Data:

Sensor data:Measuring range:Resolution: Accuracy:

General details:Operating temperature:Humidity:Environmental conditions:

Safety classification:

-20°C to +85°C 0,1°C +15°C to +30°C: typical 0,3°C -20°C to +85°C: typical 0,6°C

o o-20 C bis +85 Cmax. 80% rel., no condensationstationary installation according to VDE 632, VDE637

IP 20

Page 4: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

The LCN-TSA is an especially small, high precision, digital temperature sensor for outdoors.With its own processor it records almost noiseless measurements and sends them via the I-Port connector to the connected LCN module.

Description:

The temperature sensor is used for determining outdoor temperature. By connecting further sensors to the LCN bus, an energy saving and user friendly single room heating regulation system can be implemented which, among other things, includes control of the ventilation system.

It additionally allows for the calculation of indoor and outdoor temperature differences (e.g. for passive nocturnal cooling and conservatory control).

The LCN-TSA can operate in parallel with all other modules connected to the I-port connector on all intelligent LCN modules (UPP, UPS, UP24, SH, HU).The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used for regulating purposes.Measured values can be exchanged between operational LCN modules and their differences calculated.

Hardware equipment:

LCN-TSA:

Temperature sensor, in protective mould

Wall or ceiling mounting with PVC clip

2m connecting cable with plug to I-Port connector

LCN-IV:

Cable with plug for the I-Port connection

2 spare I-Port sockets for connection of further peripherals

Screw terminals for cable up to 0,8mm Ø

Note:The assembly position and location may influence the recorded valu-es: air-streams, mounting height and heat sources (heat radiating from lighting) are all to be considered.

If the supply cable is to be extended outdoors, then a terminal connec-tor in IP65 protective casing is to be used.

The supply cable can be extended up to 50m.

For more detailed information please refer to the installation instruc-tions.

Prec.-temperature sensor (0,1°C) for outdoor application

LCN-TSA

100

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Page 5: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

I

LCN-IV LCN-TSA

Prec.-temperature sensor (0,1°C) for outdoor application

LCN-TSA

D

L

N

PE

D

L

N

PE

65mm

ø1

5m

m

101

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Circuit diagram

LCN Bus Module

Assembly: LCN-TSA:Roof or wall mount using cableclip

LCN-IV:Decentral Installation

65 mm x 15 mm ø

22 mm x 12 mm x 13 mm

2 m

Dimensions:

Sensor LCN-TSA

LCN-IV (L x W x H):

Supply cable:

(L x ø):

Technical Data:

Sensor data:Mesured range:Resolution: Accuracy:

Supply cable:

General details:

Operating temperature:Enviromental conditions:

Safety classification:Sensor LCN-TSA:LCN-IV

-20°C to +85°C 0,1°C +15°C to +30°C: typical 0,3°C -20°C to +85°C: typical 0,6°C -2 m, LiYCY, multi core

o o-20 C to +85 CStationary installation according to VDE632, VDE637

IP 65IP 20

Page 6: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

The motion detector LCN-BMI recognizes motion by thermal radiation emitted from the body. It is used for switching on various lighting (hallways, offices, toilets). Additionally, it can work as an alarm function in building surveillance.

Description:

The LCN-BMI is a PIR motion detector designed for use indoors. It must be connected to an intelligent LCN-module.

The sensor works according to the PIR principle (passive infra-red). It registers changes in thermal radiation due to human presence.

Hardware equipment:

Jumper for the parallel operation of several LCN-BMIs

Casing for wall or ceiling assembly IP 20 Cable with plug for the I-Port connection

Note:The LCN-BMI and LCN-B8x cannot be used on one module at the sa-me time.

A maximum of 4 LCN-BMI can be operated and separately evaluated on one I-port. Therefore the BMI’s need to be coded.

The position of the sensor essentially influences its sensitivity. It has to be installed in such a way so that warm parts of the body (face) are detected. The main direction of motion should be at right angles to the sensor. It is therefore advisable to mount the sensor pointing sideways rather than centrally when fixing to a ceiling. For more detailed infor-mation please refer to the installation instructions.

PIR motion detector

LCN-BMI

102

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Functional Specifications:

Operating programs:

The presence and motion sensor triggers a 'hold' command to the bus module the moment motion is detected. If the object is only within the detection field for a short time < 2sec, the 'release' command is initiated after 4 seconds. If the object is registered over a longer period of time, the “release” command is initiated 8 seconds after the last detected motion. The LCN-BMI also transmits status reports automatically without parametrisation.

Page 7: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

PIR motion detector

LCN-BMI

D

L

N

PE

D

L

N

PE

I

103

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

LCN Bus Module

Circuit diagram

Assembly:

45 mm x 25 mm

300 mm

Dimensions:

(ø x H):

Supply Cable:

45

mm

25

mm

ceiling- or wall assemblyon 35mm wall light box

Sensor:Range:Mode of operation:Seizing range:

General details:Operating temperature:Humidity:Environmental conditions:

Safety classification:

max. 10m PIR (passive infrared)110°

o o-10 C to +40 Cmax. 80% rel., no condensationstationary installment according to VDE 632,VDE 637

IP 20

Technical Data:

Page 8: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

LCN-GRTTemperature sensor and IR receiver in glass design (LCN-GT series)

The LCN-GRT is a temperature sensor and IR receiver for surface mounting in LCN-GT series design.In combination with the integrated logic, the digital temperature sensor supplies almost noiseless measured values, which it transmits to the connected LCN module via the I port.

Description:

The LCN-GRT is used for the measurement of room temperatures and the integration of the LCN-RT remote control and LCN-EFS humidity sensor. It can be linked to additional sensors on the LCN bus in order to implement an energy-efficient and user-friendly control system for individual rooms, heating, air conditioning and ventilation.

The integrated LCN-RR IR receiver allows the LCN-GRT to process the signals of LCN remote controls. It can receive and forward up to 48 commands, 16 million access codes and 3333 key codes.The LCN-GRT can be combined with any I port peripheral equipment at the I port of all intelligent LCN modules (-UPP, -UPS, -UP24, -SH, -SHS, -HU, -LD). The LCN-GRT can take effect on the R1 and R2 controllers as well as the signal thresholds 1-5.Measured values can be exchanged between LCN modules and used for arithmetic operations.

Hardware equipment:

Temperature sensor

Infrared receiver

Installation space for LCN-EFS

Housing for wall and ceiling mounting

Cable with plug for I port

Screw terminal for connection via I-Y(St)Y

Note:The installation location and position have an influence on the mea-sured values and the reception range: the air currents, installation height and heat sources (lamp radiation) are to be observed.

The supply line can be extended by up to 50 m.

Detailed information can be found in the installation instructions.

LCN-EFS humidity sensor:

A humidity sensor (LCN-EFS), which can be subsequent installed, is optionally available for the LCN-GRT. The LCN-EFS supplies humidity and dew point values.

Modells:

LCN-GRT

Color: white LCN-GRTWblack LCN-GRTB

104

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Page 9: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

Temperature sensor and IR receiver in glass design (LCN-GT series)

LCN-GRT

D

L

N

PE

D

L

N

PE

I

LCN-GRT

105

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Technical data:

ConnectionSupply voltage:Power consumption:

Temperature range:Effective range:Resolution: Accuracy:

not necessary ( I-port-connection)<0,1W

-10°C to +60°C 0,1°C typ. 0,3°C from +15°C to +30°Ctyp. 0,6°C from -20°C to +85°C,max. 2°C for the complete range

IR receiver:Carrier frequency:

Installation moisture sensor:Resolution: Accuracy at 20-80% humidity: Out of range:

Dew pointResolution: Accuracy at 20-80% humidityand 10-40°C ambient temperature:

Ports:I-port:

General data:Operating temperature:Humidity:Environmental conditions:

Safety classification:

40kHz

(Order separately where appropriate)1% humidity

±4%±6%

0,1°C

±2°C

Circuit connectors or spring clips

o o-10 C to +60 Cmax. 80% rel., no condensationstationary installation VDE 632,VDE 637IP20Assembly:

60mm x 60mm x 24mm 12mm280mm

Dimensions:

Housing (W x L x H):Depth:Supplied flat cable:

60

mm

Wall- or ceiling-mounted on 35mm light outlet box or screw mounting

60mm

LCN-bus module

Circuit diagram

Frame: Available in white and black,

customised special colours on

request.

Page 10: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

The LCN-GBL is a presence detector with integrated light sensor for surface mounting in LCN-GT series design.The presence detector works according to the passive infrared principle. It registers changes to the thermal radiation of a (human) body.

Description:

The light sensor is used to register the brightness in rooms. The measured value can be used for constant light control in order to achieve ideal lighting conditions with simultaneous energy saving.The brightness value can be used to control the shading system.The presence/motion detector identifies the motion of persons and objects by their thermal radiation. It can be used, optionally with the integrated light sensor, to switch lightings and for alarm functions in the building security area.The integrated light sensor covers a very large measurement range of 5 decades (1-100,000 lux).

The LCN-GBL can be combined with any I port peripheral equipment at the I port of all intelligent LCN modules (-UPP, -UPS, -UP24, -SH, -SHS, -HU, -LD). The LCN-GBL can take effect on the R1 and R2 controllers as well as the signal thresholds 1-5.

Measured values can be exchanged between LCN modules and used for arithmetic operations.

A humidity sensor (LCN-EFS), which can be subsequent installed, is optionally available for the LCN-GRT. The LCN-EFS supplies humidity and dew point values.

Hardware equipment:

Presence detector

Light sensor

Installation space for LCN-EFS (option)

Housing for wall and ceiling mounting

Cable with plug for I port

Screw terminal for connection via I-Y(St)Y (saves one LCN-IV)

Note:The installation location and position have an influence on the measu-red values: the installation height and variable heat sources are to be observed. For ideal measurement sensitivity, it is recommended to in-stall the LCN-GBL under the ceiling. The supply line can be extended by up to 50 m.

Detailed information can be found in the installation instructions.

LCN-GBLPresence detector and light sensor in glass design (LCN-GT series)

LCN-EFS humidity sensor:

A humidity sensor (LCN-EFS), which can be subsequent installed, is optionally available for the LCN-GBL. The LCN-EFS supplies humidity and dew point values.

Modells:

LCN-GBL

Color: white LCN-GBLW

black LCN-GBLB

106

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Page 11: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

LCN-GBLPresence detector and light sensor in glass design (LCN-GT series)

D

L

N

PE

D

L

N

PE

I

LCN-GBL

107

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Assembly:

60mm x 60mm x 30mm18mm280mm

Dimensions:

Housing (W x L x H):Depth:Supplied flat cable:

60

mm

Wall- or ceiling-mounted on 35mm light outlet box or screw mounting

60mm

Frame: Available in white and black,

customised special colours on

request.

LCN-bus module

Circuit diagram

ConnectionSupply voltage:Power consumption:

Presence detector:Scope:Method:Detection area:Debouncing time:

Light sensor:Measurement spectrum:Measurement range:Accuracy:Resolution:

Ports:I-port:

Recessed moisture sensor:HumidityResolution: Accuracy at 20-80% humidity: Out of range:

Dew pointResolution: Accuracy at 20-80% humidity and 10-40°C ambient temperature:

General data:Operating temperature:Humidity:Environmental conditions:

Safety classification:

not necessary ( I-port-connection)<0,1W

typ. 10m PIR (passive infrared)110°5 seconds

450-650nm1-100.000Lx±15% out of range1% of Lux-value

Circuit connectors or spring clips

1%

±4%±6%

0,1°C

±2°C

o o-10 C to +60 Cmax. 80% rel., no condensationstationary installation VDE 632,VDE 637IP 20

Technical data:

Page 12: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

ISSENDORFF KG Magdeburger Str.3 30880 Rethen Tel: 05066 99 80 www.LCN.eu

LCN-GUS / LCN-GUS68

Perfection.

Sensor for temperature, light, humidity, motion & IR receiver in glass design

Sen

so

rs

ConfigurationThe LCN-GUS is detected automatically. The measured values can be seen in the status window of LCN-PRO.

DIP switch

The parallel operation of several LCN-GUS is possible with different positions of DIP switches.

Models:

LCN-GUS

60mm x 60mm

Colour: white LCN-GUSWchampagne LCN-GUSC

LCN-GUS68:

90mm x 90mm

Colour: white LCN-GUS68Wchampagne LCN-GUS68C

108

The LCN-GUS is a temperature, light, humidity, motion sensor and IR receiver for surface mounting in LCN-GT series design.The LCN-GUS can be operated to of any LCN bus module with firmware 1702... (Feb. 2013) or after.

Field of application:

The digital temperature sensor with its own processor it records almost noiseless measurements and sends them via the I-Port connector to the connected LCN module.

The integrated LCN-RR IR receiver allows the LCN-GUS to process the signals of LCN remote controls.

The light sensor is used to register the brightness in rooms. The measured value can be used for constant light control in order to achieve ideal lighting conditions with simultaneous energy saving. The integrated light sensor covers a very large measurement range of 5 decades (1-100,000 lux).

The presence/motion detector identifies the motion of persons and objects by their thermal radiation. It can be used, optionally with the integrated light sensor, to switch lightings and for alarm functions in the building security area.

The LCN-GUS can take effect on the controllers as well as the signal thresholds .Measured values can be exchanged between LCN modules and used for arithmetic operations.

Hardware equipment:

Presence detector, light sensor, temperature sensor,

IR receiver and humidity sensor

Housing for wall mounting

Cable with plug for I port

Screw terminal for connection via I-Y(St)Y (saves one LCN-IV)

Note:The installation location and position have an influence on the measu-

red values: the installation height and variable heat sources are to be

observed.

For ideal measurement sensitivity, it is recommended to install the LCN-GUS on the wall.

The LCN-GUS can be combined with any I port peripheral equipment at the I port of all intelligent LCN modules (-UPP, -UPS, -UP24, -SH, -SHS, -HU, -LD) with firmware 1702... (Feb. 2013) or after. The supply cable can be extended up to 50m.

Detailed information can be found in the installation instructions.

Page 13: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

ISSENDORFF KG Magdeburger Str.3 30880 Rethen Tel: 05066 99 80 www.LCN.eu Perfection.

Sensor for temperature, light, humidity, motion & IR receiver in glass design

LCN-GUS / LCN-GUS68

Circuit diagram

D

L

N

PE

D

L

N

PE

Technical data

Sen

so

rs

Assembly:

Dimensions:

Housing (L x B x H):

Frame: Available in white or champagnecustomised special colours on request

LCN-bus module

I

LCN-GUS/.GUS68

109

ConnectionSupply voltage:Power consumption:I-port:

Presence detector:Scope:Method:Detection area:Debouncing time:

Temperature sensor:Effective range:Resolution: Accuracy:

Light sensor:Measurement spectrum:Measurement range:Accuracy:

Humidity sensor:Measurement range:Resolution: Accuracy:

Dew point:Resolution: Accuracy at 20-80% humidity and 10-40°C

General data:Operating temperature:Environmental conditions:

Safety classification:

not necessary ( I-port connection)6mW circuit connectors or spring clips

typ. 12m PIR (passiv infrared)100°x360°5-8 seconds

-10°C bis +60°C 0,1°C typ. 0,2°C from +5°C to +60°C

450-650nm, typ. 560nm1-100.000Lx, +/-15%, 1Lx of 1000Lx

0-100%, non condensing1% (relative humidity)+/3% from 20% to 80%

0,1°C

+/-2°C

-10°C to +60°Cstationary installation VDE

IP 20

I-port

LCN-GUS:

60mm x 60mm x 15,5mm

(3mm)

LCN-GUS68:

90mm x 90mm x 18mm

(5mm)

60

mm

60mm

90

mm

90mm

LCN-GUS LCN-GUS68

LCN-GUS: Wall mounted on 35mmlight outlet box or screw mounting. With the LCN-A6835 the adapter frame, 68mm flush mounted boxes and cavity wall boxes can be reduced to the size of a 35mm lamp outlet box.

LCN-GUS68: With mounting plate for a 68mm flush mounted wall-box.

Page 14: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

LCN-IVI-Port extension for LCN

The LCN-IV is used for multiplying the I-Port connections on an in-telligent bus module. This allows for several sensors to be connec-ted to the module.

Description:

The LCN-IV is used for connecting more than one sensor to an intelligent bus module and for separating the sensors locally from the module.

In this way for example, remote-control receivers, temperature sen-sors and a binary sensors can be decentrally installed together on site. In doing so, each room has its own functional unit (e.g. lighting, alarm system and temperature regulation).

Additionally the LCN-IV allows sensors to be strategically placed which is useful when considering such factors as heat radiated from lights, field of view etc.

By using the screw terminals, the LCN-IV can be coupled with a se-cond LCN-IV. The IY(ST)Y 2x2x0.6mmØ is recommended as the supply cable which must not exceed a max. length of 50m.

Alternatively, the LCN-IV can be used as an impulse counting device for fast signals (max. 500Hz, e.g. wind sensor).

Hardware equipment:

Cable with plug for the I-Port connection

2 spare I-Port sockets for connecting further peripherals

Screw terminals for cable up to 2 x 0,6mm Ø or 1 x 0,8mmØ

Note:When the LCN-IV is used as an impulse sensor, the utilisation of other devices on the LCN-IV is not possible. For more detailed information please refer to the installation instructions.

110

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Functional specifications:

Serving as either an extension for the I-Port connector or as an adapter for further I - Port connections, the LCN-IV has no active function.When used as an impulse counter it provides the module with its counter value. This can then be evaluated via the switching threshold.

Page 15: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

LCN-IVI-Port extension for LCN

Max.50m0,8mm²

321G

321G

321G

D

L

N

PE

D

L

N

PE

111

I

I

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Dimensions:

(L x W x H):

Supply Cable:

Assembly:

Circuit diagram

22 mm x 12 mm x 13 mm

300mm

22 mm

12

mm

de-centralized installation in deep flush-mounted box

Technical Data:

Connection:Wiring option:Conductor type:

Cable length:

Ports:T-Connection:I-Connection:P-Connection:

General details:Operating temperature:Humidity:Environmental conditions:

Safety classification:

for screwingmassive or multi-phase (max.

0,8mmØ), with and without insulated pin terminals

max. 50m

not available available, 2-waynot available

o o-10 C to +40 Cmax. 80% rel., no condensationstationary installation according to VDE 632,VDE 637

IP 20

LCN-bus module

LCN-bus module

to peripherals

impulse meter

example application 1:extension / expansion

example application 2:counting with potential-free contacts

Page 16: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

LCN-IVHAdapter for I-port extension / duplication for DIN rail mounting

112

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

The LCN-IVH is used for extending and splitting the I-Port connection so that sensors for the I-Port (e.g temp sensor, remoter control receiver) can be decentrally installed

Description:

The LCN-IVH is used for expanding the I-port connections on an intelligent bus module, so several sensors can be operated by one intelligent module.By using the screw terminals the port can be extended up to 50m using the IY(ST)Y 2x2x0.6 cable.Alternatively, the LCN-IVH can be used as an impulse- counting device for fast signals (max. 500Hz, e.g. wind sensor).

Hardware equipment:

1 I-Port connection cable

1 I-Port connection for further peripherals

Screw terminals for connection extension.

Note:

When the LCN-IVH is used as an impulse sensor, the utilisation of ot-her devices on the LCN-IVH is not possible. When deploying LCN peri-pherals such as RR, BMI, TS etc., an LCN-IV is additionally necessa-ry.

For more detailed information please refer to the installation instruc-tions.

Functional specifications:

Serving as either an extension for the I-Port connector or as an adapter for further I-Port connections, the LCN-IVH has no active function.When used as an impulse counter it provides the module with its counter value. This can then be evaluated via the switching threshold.

Page 17: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

LCN-IVH

D

L

N

PE

D

L

N

PE

max. 50m0,8mm²

LCNLCN-IVH

I-PortVerteiler

HutschieneLmax=100m

123

Gnd

LCNLCN-IVH

I-PortVerteiler

HutschieneLmax=100m

123

Gnd

I I

113

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Circuit diagram

Dimensions:

(L x W x H):

Supply Cable:

Assembly:

Space requirement:

17,5 mm x 92 mm x 66 mm

300mm

1TE

66 m

m

37 mm

61 mm

17,5 mm

92 m

m

REG on 35 mm mounting rail(DIN 50022)

impulse meter

LCN-bus module

to peripherals

LCN-bus module

Technical Data:

Connection:Wiring option:Conductor type:

Cable length:

Ports:I-connection:

General Details:Operating temperature:Humidity:

Environmental conditions:

Safety classification:

for screwingmassive or multi-phase (max.

0,8mmØ), with and without insulated pin terminals

max. 50m

available 1-way, with screw terminals

o o-10 C to +40 Cmax. 80% rel., no condensation

stationary installation according to VDE 632,VDE 637

IP 20

I-Port extension for DIN rail mounting

Page 18: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

The LCN-CO2 is a CO sensor for the indoor area. It can measure CO 2 2

concentrations of 1-5000 ppm.

Description:

The LCN-CO2 measures the carbon dioxide content (CO ) of the air in 2

the interior of buildings. This enables the energy-efficient control of ventilation and air conditioning systems and thus demand-oriented supply of fresh air.

In this way, the LCN-CO2 makes an active contribution towards healthy room air quality.

The sturdy, compact sensor uses an infrared-based spectroscopic measurement method to measure the carbon dioxide content of the air. It responds even to slightest changes to the air composition.

The LCN-CO2 can be combined with any I-port peripheral equipment at the I port of all intelligent LCN modules (-UPP, -UPS, -UP24, -SH, -SHS, -HU, -LD). The LCN-CO2 can take effect on the R1 and R2 controllers as well as the signal thresholds 1-5.

Measured values can be exchanged between LCN modules and used for arithmetic operations.

Hardware equipment:

CO sensor for determining the room air quality2

Housing for mounting on 68 mm flush-mounted socket

Cable with plug for I ports

LCN-NU16 (power supply unit)

Note:For more detailed information please refer to the installation instructions.

LCN-CO2Carbon dioxide sensor (CO ) for the I-port2

114

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Page 19: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

LCN-CO2

• CO2 sensor for indoor air quality determination• captures CO2 concentrations of 1-5000 ppm

Carbon dioxide sensor (CO ) for the I-port2

80

mm

79mm

D

L

N

PE

D

L

N

PE

I

LCN-NU16

+-

115

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

79mm x 80mm x 26mm

280 mm

Assembly: on 68 mm flush-mounted socketor screw fixture

Dimensions:

(L x W x H):

Supply Cable:

Circuit diagram

to the I-Port

LCN-module

up

Connection:Power Supply:

Measuring range:Input potential:Resolution:

Ports:I-Port

General details:Operating temperature:Humidity:

Environmental conditions:

Safety classification:

via LCN-NU16(scope of delivery)

1-5000ppm±30ppm ±5% vom Messwert1ppm

available / already in use

o o-10 C to +40 Cmax. 80% rel., no condensation

stationary installation VDE 632,VDE 637

IP 20

Technical Data:

Page 20: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

The LCN-AD2 is a 2 way analog to digital converter with a 12 Bit trigger for the I-port connection.

Description:

The LCN-AD2 is applied for the recognition of signals, for those that are not equipped with special sensors. for example sensors with very high temperatures, hygrometres, etc. The LCN-AD2 can be applied universally, because its inputs can be adjusted as follows:

Voltage: 0-10VElectric current: 0(4)-20mATemperature: Pt100/Pt1000 (Platinum-temperature-sensors).

The measured values are entered into the module as R1 and R2 variables. They work optional on the 5 threshold values or on both regulators.

Hardware equipment:

Analogue input

DIP-switch for setting the signal type

Status-LED

Flat cable for I-port connection

Note:The LCN-AD2 can be connected to an I-port of an LCN module manufactured after series number 170206 , This cable connection can be lengthened by using a LCN-IV - see also "TD I-port peripherals" (www.LCN.de/Downloads). For detailled information please read the installation guide.

LCN-AD22-way analogue to digital converter for DIN rail mounting

116

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Page 21: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

LCN-AD2

• Analog - to-digital converter• 12-bit resolution• universally applicable for : Voltage: 0 - 10V Current: 0(4) - 20 mA Temperature : Pt100 / Pt1000• Connected to the I- port

2-way analogue to digital converter for DIN rail mounting

D

L

N

PE

D

L

N

PE

38mm

92m

m

66m

m

61m

m

- +

L L N N

I ON

1 2

ON

1 2

PtIU

- +

LCN

2-ChannelA/D Converter

In:0-10V, 0/4-20mA, Pt100(0)

LCN-AD2

117

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Dimensions:

(L x W x H):

Supply Cable:

113 x 38 x 66 mm

300 mm

Assembly:

Space requirement: 2TE

Height: 66mm 61mm via DIN rail

REG on 35 mm mounting rail(DIN 50022)

Circuit diagram

230V AC ±15%, 50Hz(115V AC ±15% type available)screwlessmassive or multi-phase

2(max.2,5mm ) or with insulated pin terminals

2 (max.1,5mm )

I-Port

2max. 500V towards N0-10V, 0/4-20mA, Pt100, Pt100012 Bitscrewlessmassive or multi-phase(0,2-1,5mmØ) or withInsulated pin terminals (0,5-1,38mmØ)

o o-10 C to +40 Cmax. 80% rel., no condensation

stationary installation VDE 632,VDE 637

IP 20

Connection:Power Supply:

Wiring option:Conductor type:

LCN-Port:

Inputs:Number:Input potential:Measuring range:

Resolution:Wiring option:Conductor type:

General details:Operating temperature:Humidity:

Environmental conditions:

Safety classification:

Technical Data:

LCNbus module

Page 22: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

The LCN-ZEA is a time receiver (GPS) for the I-port

Description:

The central european time (CET) is calculated from the UTC signal of the receiver. For operating in other time zones worldwide, the settings can be changed with the LCN-PRO. The toggling between summer and winter time is carried out automatically in all time zones. The LCN-ZEA is recognized automatically. With normal receptional conditions, the sensor sends the central european time (CET) after around 3 min., over the I-port to the module, then into the LCN bus. The LCN-ZEA can be operated on the I-port of any LCN bus module with firmware 1702... (Feb. 2013) or after.

Note:The LCN-AD2 can be connected to an I-port of an LCN module manufactured after series number 170206 , This cable connection can be lengthened by using a LCN-IV - see also "TD I-port peripherals" (www.LCN.de/Downloads). For detailled information please read the installation guide.

GPS-receiver time zone:

Delivery status: central european time (CET), configuarable. All

worldwide summer time changes are supported.

LCN-ZEATime receiver (GPS) for the I-port

118

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Page 23: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

LCN-ZEA

• receives the GPS signal• sends precise time in the LCN bus• connected to the I-port

Time receiver (GPS) for the I-port

Assembly screw fixture

51mm x 51mm x 36mm

51m

m

51mm

51mm

36m

m

51mm 119

max. 50m!

Circuit diagram

D

L

N

PE

D

L

N

PE

Power supplyLCN-NUI

LCN-Bus modul

I II I LCN-IV

LCN-ZEA

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Dimensions:

(L x W x H):

Connectionpower supply: LCN-NUI/-NIH (over I-Port)power consumption : 0,2WLCN-connection: I-Port extension

2terminals/wire type: screwless terminals 0,2-0,75mm

GPS-receivertime zone: delivery status: central european

time (CET), configurableall worldwide summer time

changes are supported.General details:Operating temperature: -20°C to +50°CEnvironmental conditions: use as stationary installation

according to VDE632, VDE637Safety classification: IP 65

Technical Data:

Page 24: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

120

Fingerprint sensor in GT-design

LCN-GFPS

LCN-WSThe protection cover including sealing ring is provided for outdoor installation of LCN-GFPS.

Field of application:The weather protection cover incl. the sealing ring allows the outdoor installation of the LCN GFPS, without splashing occurs .

Modells:

LCN-GFPS• Size: 90mm x 90mm

Color: white LCN-GFPSWblack LCN-GFPSB

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

The LCN-GFPS is a fingerprint sensor for the I-port of any LCN module with version 190512 (Mai 2015). The LCN-GFPS scans fingerprints and transfers an assigned code over the LCN bus.

Description:

The LCN-GFPS can be used for all types of access control. Besides automatic opening and closing of doors, gates and windows, the alarm systems can be also activated or deactivated. Using the LCN-GFPS you may combine the access control with switching the light in the office.

A Corona® surrounding light with 16 white LEDs serves as a decorative accent lighting and as a discreet orientation light, so that the LCN-GFPS can be comfortably operated even with a low environmental light.

Hardware equipment:

LCN-GFPS

LCN-NUI power supply unit

I-port & mounting plate

Note:To avoid interference, the supply voltage of the power supply unit should be identical to the voltage of the intelligent LCN module.

For more detailed information please refer to the installation manual.

Page 25: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

121

Technical Data

Fingerprint sensor in GT-design

LCN-GFPS90m

m

90mm

16,9mm

90

mm

D

L

N

PE

D

N

PE

LCN-Busmodulmit I-Anschluss

NetzteilLCN-NUI

I II I

LCN-GFPS

L

max.50m

max.20mI-Anschluss Verlängerung

44mm

44

mm

Perfection.ISSENDORFF KG Magdeburger Str.3 30880 Rethen/Germany Tel: +49 (0)5066 99 80 www.LCN.eu

Sen

so

rs

Connectionpower supply: over

LCN connection: on the I-port of an LCN bus module with firmware 190512... (May 2015) or after, for bidirectional communication

Functionsensor: fingerprint scanner für max. 999 fingers

with living finger recognition

LED´s: 4 LED´s for showing the sensor status ®16 white corona -LED´s controllable over the command „LED

GT-brightness” in 10 steps

Installationdimensions (W x H x D): 90mm x 90mm x 16,9mm (5mm glass thickness)operating temperature: -10°C to +50°Cair humidity: max. 80% rel., non condensingenvironmental conditions: for use as stationary installation according to VDE632, VDE637protection art: IP20 a please make sure when installing outdoors, that the

LCN-GFPS is not exposed to direct dampness (splash water or

rain) and direct sunlight!

installation: installation over a flush mounted box

the I-port (LCN-NUI)

Technical Data (LCN-NUI)

input voltage: 110V - 230V AC, 50/60Hz2connection input voltage: 2 wires with wire end-sleeves 0,75mm

output voltage: 5V DC (stable)

power output: max. 2,5W

connection input voltage: 3 I-port connectors

environmental temperature: -10°C to + 40°C, air humidity: max. 80% rel., non condensing

usage: stationary installation according to VDE632, VDE637

protection art: IP20

dimensions: ø 50mm x 22mm

Note: to avoid interference, the power supply (live phase) must be identical to the intelligent

module, on which the supplied periphery is being operated on. 90mm x 90mm x 16,9mm

Dimensions:

(L x W x H):

Circuit diagram

Page 26: 006 Handbuch 2017 Sensors eng - LCN · UPS, UP24, SH, HU). The module enables the option of having two continuous action control circuits plus 5 thresholds which can also be used

Sen

so

rs

122