    Se lf-clea ning fi lt e rSe lf-clea ning fi lt e rThe GDX downflow airflow design, com-

    bined with pa tented Spider-Web filter media

    technology, enhance the pulse cleaning

    performance:

    Minimum filter service requirements.

    Low filter operating pressure drop over

    the life of the filter.

    Featu ring Spider-Web or Spider-Web

    XP filter media for high performanceand long life.

    Versat i leVersat i leGDX, now used on thousands of turbines

    and generators aroun d the w orld, is ideally

    suited for protecting turbines from a wide

    variety of harsh environments:

    Remote locations that need long filter

    service life.

    Environments with high dust concentra-

    tions that need a self-cleaning filter.

    Desert and arctic climates

    Pulse system performs perfectly on both

    sand and frost.

    In cold and arctic climate condition s there

    is no n eed for a nti-icing systems.

    A ir inle t fi lt e rA ir inle t fi lt e re n ha n ce m e n t se n h a n c e m e n t s Inlet silencing systems and at tenua tion

    hood s especially useful in urb an

    areas where noise must be muted.

    Evaporat ive coolers to opt imize air

    inlet temperatures so as to increase power

    output from gas turbines operating in high

    temperature environments.

    Chiller coils chiller coils can p rovide

    additional power output from gas turbines

    operating in humid environments where

    evaporative cooling systems may be less

    effective.

    Downstream/inlet heating For control

    of icing and NOx emissions when used with

    advanced turbine control systems. Transition and ducting Lined or

    unlined ducting, angled or straight.

    G DX T M S e lf-cle a ning p ulse

    Donaldsons GDX

    Air Inlet Filtra tion System

    s currently the defac to

    standard self-cleaning

    filter for gas turbines

    around the w orld.

    High e f fi c iency , long- lif e fi lt e rs m ade w ith Sp ider -W eb o r

    S p id e r -W e b X P

    Spider-Web is Do naldsons pro prietary filter media

    treatment, a fine, even web of n anofibers bonded

    to a filter media substrate (either purely synthetic

    or a natural/ synthetic blend). Th is nanofiber web

    increases filter efficiency, especially on very small

    corrosive particulate that cause compressor foul-ing, and enhances particle release during pulse

    cleaning.

    In this pho to from the scanning electron microscope @ 2500 X magnification you can see the larger

    fibers of the substrate under the web o f fine fi bers.

    Donaldson often provides the ducting to

    the turbine along with the filter house for

    all type of filters.

    Don aldson designs and m anufactures a

    full line of replacement filter elements, f or

    Don aldson systems, as well as for other

    brands.

  • 8/2/2019 004687

    3/4

    H ow it w o rk sH ow it w o rk sAir is drawn into th e GDX system through inlet hoods that pro-

    tect the filters from the effects of rain, snow and sun. These inlet

    hoods contain deflectors that direct the incoming air downw ard.

    The incoming air is cleaned by pairs of filters installed horizon-

    tally against a tube sheet, using an outside-to-inside airflow path.

    Cleaned air then passes to the turbine.

    A walkwa y behind t he inlet hoods provides easy service access to

    the filters and inlet treatment accessories, such as moisture elimi-

    nators, bird/trash screens, and inlet heaters.

    When the pressure drop across the filters reaches a certain point,

    monitoring devices trigger a strong, brief reverse blast of air,which knocks much of the accumulated dust off the filters sur-

    face. The operator can set this point to fit the conditions of the

    environment.

    De signe d for lowDe signe d for low PPa n d lo w m a in t e n a n c ea n d lo w m a in t e n a n c eThanks to the automatic pulse cleaning design, the GDX oper-

    ates almost maintenance free, making GDX the best choice even

    for remot e or d ifficult-to-access locations. And, because the pulse

    cleaning operation keeps system pressure drop ( P) low, the tur-

    bine can run at p eak efficiency to max imize power outpu t.

    D o w n w a r d a ir fl o w d e s ig nD o w n w a r d a ir fl o w d e s ig nA p e r f o r m a n ce a d v a n t a g e

    If a gas turbine is operating in applications with high concen-

    trations of very fine dust particles, GDX performance is highly

    desired. The GDX has a layered downward airflow design, which

    offers performance advan tages over trad itional pu lse-cleaning sys-

    tems that pull air in an u pward direction. The down ward a irflow

    design forces dust that has been dislodged during the cleaning

    process down into the hopper below and minimizes dust migra-

    tion back into the filters.

    M o d u la r c o n s t r u c t io nM o d u la r c o n s t r u c t io nModules are 4 filters wide and range in height from 8 to 25 filters

    high. Th ese are the bu ilding blocks used to crea te GDX self-clean-

    ing filter systems to suit your specific requirements.

    fi lt e r sy st e m

    H e a r t o f t h e sy s t e mH e a r t o f t h e sy s t e mTo maximize filtering area, conical and cylindrical

    elements are paired and mounted horizon-

    tally. The blue color of the media indi-

    cates Spider-Web, our patented

    nanofiber technology that yields

    best protection for turbines.

    Global capabi l i tyGlobal capabi l i tyDonaldson Gas Turbine Systems has developed a network of

    qualified vendors to complement Donaldsons worldwide produc-

    tion and engineering capab ilities.

    Dona ldson has the ability to meet local content requirements thro ugh

    the combination of the vendor network and own facilities located

    throughout the world.T h e m o d u la r d e s ig n o f t h e G D XT h e m o d u la r d e s ig n o f t h e G D Xs y s t e m p r o v id e ss y st e m p r o v id e s Custom d esigns to fit any site, as well as specifications

    at pr ices and lead times that can normally be found onlyon standard product.

    Efficient on-site erection.

    Donaldsons modular approach to system design m akes on-site erection

    simpler and faster anyw here in the w orld.

    D i r t yD i r t ya ira ir C l e a nC l e a n e de d a ira ir

    C l e a nC l e a n a ira irs e c t i o ns e c t i o nD i r t yD i r t y a ira irs e c t i o ns e c t i o nS e r v i c ew a lk w a y

    T u b e s h e e t

    In le t h oods Filt e r ca r t ridge p a ir C om pre sse d

    air pulse

    Drawing of how it

    works w ith dirty

    air/cleaned air

    C o m p r e s s e d a ir

    m a n i f o ld

    H o p p e r

  • 8/2/2019 004687

    4/4

    Regional Headquar ters

    Europe, Middle East and Africa

    Dona ldson Europe b.v.b.a.

    Research Park Zone 1

    Interleuvenlaan 1

    B-3001 Leuven

    Belgium

    Tel. + 32 16 38 39 40

    Fax + 32 16 38 39 39

    Email: GT [email protected]

    Regiona l Headqua rter s-Asia Pacific

    Donaldson Filtration Pte. Ltd.

    No.3, Chan gi Business Park Vista # 02-0 0

    Singapore 486051

    Tel. + 65 6311 7373

    Fax + 65 6311 7398

    Email:[email protected]

    Worldwide H eadquarters

    Donaldson Company Inc.

    1400 W. 94th Street

    PO Box 1299

    Minneapolis

    M innesota 55440

    USA

    Tel. + 1 952 887 3131

    Fax + 1 952 887 3843

    Email: [email protected] ldson.com

    www.donaldson.com

    Donaldsonreservestherighttochangeand/ord

    iscontinueanymodelorspecificationatanytimeandw

    ithoutnotice.Copyright2004

    -GDXTMisatrademarkofDonaldson.

    Spider-Web

    isaregisteredtr

    ademarkofDonaldson.

    GDX GT S - 106