004687
-
Upload
feraselnggar -
Category
Documents
-
view
221 -
download
0
Transcript of 004687
-
8/2/2019 004687
1/4
G D X T M
T h e r e is n o s u b s t it u t e
f o r y o u r c h a lle n g in g
e n v ir on m e n t
-
8/2/2019 004687
2/4
Se lf-clea ning fi lt e rSe lf-clea ning fi lt e rThe GDX downflow airflow design, com-
bined with pa tented Spider-Web filter media
technology, enhance the pulse cleaning
performance:
Minimum filter service requirements.
Low filter operating pressure drop over
the life of the filter.
Featu ring Spider-Web or Spider-Web
XP filter media for high performanceand long life.
Versat i leVersat i leGDX, now used on thousands of turbines
and generators aroun d the w orld, is ideally
suited for protecting turbines from a wide
variety of harsh environments:
Remote locations that need long filter
service life.
Environments with high dust concentra-
tions that need a self-cleaning filter.
Desert and arctic climates
Pulse system performs perfectly on both
sand and frost.
In cold and arctic climate condition s there
is no n eed for a nti-icing systems.
A ir inle t fi lt e rA ir inle t fi lt e re n ha n ce m e n t se n h a n c e m e n t s Inlet silencing systems and at tenua tion
hood s especially useful in urb an
areas where noise must be muted.
Evaporat ive coolers to opt imize air
inlet temperatures so as to increase power
output from gas turbines operating in high
temperature environments.
Chiller coils chiller coils can p rovide
additional power output from gas turbines
operating in humid environments where
evaporative cooling systems may be less
effective.
Downstream/inlet heating For control
of icing and NOx emissions when used with
advanced turbine control systems. Transition and ducting Lined or
unlined ducting, angled or straight.
G DX T M S e lf-cle a ning p ulse
Donaldsons GDX
Air Inlet Filtra tion System
s currently the defac to
standard self-cleaning
filter for gas turbines
around the w orld.
High e f fi c iency , long- lif e fi lt e rs m ade w ith Sp ider -W eb o r
S p id e r -W e b X P
Spider-Web is Do naldsons pro prietary filter media
treatment, a fine, even web of n anofibers bonded
to a filter media substrate (either purely synthetic
or a natural/ synthetic blend). Th is nanofiber web
increases filter efficiency, especially on very small
corrosive particulate that cause compressor foul-ing, and enhances particle release during pulse
cleaning.
In this pho to from the scanning electron microscope @ 2500 X magnification you can see the larger
fibers of the substrate under the web o f fine fi bers.
Donaldson often provides the ducting to
the turbine along with the filter house for
all type of filters.
Don aldson designs and m anufactures a
full line of replacement filter elements, f or
Don aldson systems, as well as for other
brands.
-
8/2/2019 004687
3/4
H ow it w o rk sH ow it w o rk sAir is drawn into th e GDX system through inlet hoods that pro-
tect the filters from the effects of rain, snow and sun. These inlet
hoods contain deflectors that direct the incoming air downw ard.
The incoming air is cleaned by pairs of filters installed horizon-
tally against a tube sheet, using an outside-to-inside airflow path.
Cleaned air then passes to the turbine.
A walkwa y behind t he inlet hoods provides easy service access to
the filters and inlet treatment accessories, such as moisture elimi-
nators, bird/trash screens, and inlet heaters.
When the pressure drop across the filters reaches a certain point,
monitoring devices trigger a strong, brief reverse blast of air,which knocks much of the accumulated dust off the filters sur-
face. The operator can set this point to fit the conditions of the
environment.
De signe d for lowDe signe d for low PPa n d lo w m a in t e n a n c ea n d lo w m a in t e n a n c eThanks to the automatic pulse cleaning design, the GDX oper-
ates almost maintenance free, making GDX the best choice even
for remot e or d ifficult-to-access locations. And, because the pulse
cleaning operation keeps system pressure drop ( P) low, the tur-
bine can run at p eak efficiency to max imize power outpu t.
D o w n w a r d a ir fl o w d e s ig nD o w n w a r d a ir fl o w d e s ig nA p e r f o r m a n ce a d v a n t a g e
If a gas turbine is operating in applications with high concen-
trations of very fine dust particles, GDX performance is highly
desired. The GDX has a layered downward airflow design, which
offers performance advan tages over trad itional pu lse-cleaning sys-
tems that pull air in an u pward direction. The down ward a irflow
design forces dust that has been dislodged during the cleaning
process down into the hopper below and minimizes dust migra-
tion back into the filters.
M o d u la r c o n s t r u c t io nM o d u la r c o n s t r u c t io nModules are 4 filters wide and range in height from 8 to 25 filters
high. Th ese are the bu ilding blocks used to crea te GDX self-clean-
ing filter systems to suit your specific requirements.
fi lt e r sy st e m
H e a r t o f t h e sy s t e mH e a r t o f t h e sy s t e mTo maximize filtering area, conical and cylindrical
elements are paired and mounted horizon-
tally. The blue color of the media indi-
cates Spider-Web, our patented
nanofiber technology that yields
best protection for turbines.
Global capabi l i tyGlobal capabi l i tyDonaldson Gas Turbine Systems has developed a network of
qualified vendors to complement Donaldsons worldwide produc-
tion and engineering capab ilities.
Dona ldson has the ability to meet local content requirements thro ugh
the combination of the vendor network and own facilities located
throughout the world.T h e m o d u la r d e s ig n o f t h e G D XT h e m o d u la r d e s ig n o f t h e G D Xs y s t e m p r o v id e ss y st e m p r o v id e s Custom d esigns to fit any site, as well as specifications
at pr ices and lead times that can normally be found onlyon standard product.
Efficient on-site erection.
Donaldsons modular approach to system design m akes on-site erection
simpler and faster anyw here in the w orld.
D i r t yD i r t ya ira ir C l e a nC l e a n e de d a ira ir
C l e a nC l e a n a ira irs e c t i o ns e c t i o nD i r t yD i r t y a ira irs e c t i o ns e c t i o nS e r v i c ew a lk w a y
T u b e s h e e t
In le t h oods Filt e r ca r t ridge p a ir C om pre sse d
air pulse
Drawing of how it
works w ith dirty
air/cleaned air
C o m p r e s s e d a ir
m a n i f o ld
H o p p e r
-
8/2/2019 004687
4/4
Regional Headquar ters
Europe, Middle East and Africa
Dona ldson Europe b.v.b.a.
Research Park Zone 1
Interleuvenlaan 1
B-3001 Leuven
Belgium
Tel. + 32 16 38 39 40
Fax + 32 16 38 39 39
Email: GT [email protected]
Regiona l Headqua rter s-Asia Pacific
Donaldson Filtration Pte. Ltd.
No.3, Chan gi Business Park Vista # 02-0 0
Singapore 486051
Tel. + 65 6311 7373
Fax + 65 6311 7398
Email:[email protected]
Worldwide H eadquarters
Donaldson Company Inc.
1400 W. 94th Street
PO Box 1299
Minneapolis
M innesota 55440
USA
Tel. + 1 952 887 3131
Fax + 1 952 887 3843
Email: [email protected] ldson.com
www.donaldson.com
Donaldsonreservestherighttochangeand/ord
iscontinueanymodelorspecificationatanytimeandw
ithoutnotice.Copyright2004
-GDXTMisatrademarkofDonaldson.
Spider-Web
isaregisteredtr
ademarkofDonaldson.
GDX GT S - 106