002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series...

11
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice. ISP ’12 A 003 003 A 002 002 Signal Conditioners Product Selection Guide Signal Conditioners Product Selection Guide Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote I/O Paperless Recording System PC Recorder Electric Actuators & Position Sensors Lightning Surge Protectors Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote I/O Paperless Recording System PC Recorder Electric Actuators & Position Sensors Lightning Surge Protectors Signal Conditioners Product Selection Guide Signal Conditioners Mini-M Series Mini-MW Series M6 Series M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT Series K-UNIT Series F-UNIT Series H-UNIT Series Rack-mounted 10-RACK Series 18-RACK Series 38-RACK Series Signal Conditioners Product Selection Guide Mini-M Series Signal Conditioners Mini-MW Series M6 Series M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT Series K-UNIT Series F-UNIT Series H-UNIT Series 10-RACK Series Rack-mounted 18-RACK Series 38-RACK Series Compact Plug-in Mini-M Series Compact Plug-in Signal Splitters Mini-MW Series Ultra-Slim M6 Series Low Profile M5-UNIT Series Low Profile Signal Splitters W5-UNIT Series Thin Profile M3-UNIT Series Thin Profile M3S-UNIT Series Hybrid IC Isolation Amplifiers 20 Series P.008 P.106 P.138 P.184 P.202 P.214 P.234 P.246 Construction Plug-in Plug-in Ultra-slim Terminal block Terminal block Front terminal access Front terminal access Connection M3 screw terminal M3 screw terminal Tension-clamp, M3 screw terminal Euro terminal M3.5 screw terminal Input: M3.5 screw terminal Output & power: M3 screw terminal Removable terminal block Removable terminal block Isolation Three ways Four ways Three / four ways Three ways Four ways Three ways Three / Four ways Dielectric Strength 2000V AC 2000V AC 2000V AC DC powered: 2000V AC AC powered: 1500V AC 2000V AC DC powered: 2000V AC AC powered: 1500V AC 2000V AC Range Selectability Specified when ordering or PC / One-Step Cal programming Specified when ordering or PC programming Specified when ordering or PC programming Specified when ordering Specified when ordering or DIP switch programming PC / One-Step Cal programming Specified when ordering or PC programming Dual Output Yes Selected models Yes Selected models Power Input AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC (universal) Operating Temperature -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -20 to +55°C (-4 to +131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -25 to +65°C (-13 to +149°F) -10 to +55°C (14 to 131°F) Mounting Surface or DIN rail Surface or DIN rail DIN rail DIN rail DIN rail DIN rail DIN rail Dimensions W23 [29.5] × H76 × D124 mm (0.91” [1.16”] × 2.99” × 4.88”) W29.5 × H89 × D124 mm (1.16” × 3.51” × 4.88”) M6D/S: W5.9 × H94 × D102 mm (0.23” × 3.70” × 4.02”) M6N: W7.5 × H102 × D102 mm (0.30” × 4.02” × 4.02”) W25 × H97 × D41 mm (0.98” × 3.82” × 1.61”) W45 × H97 × D41 mm (1.77” × 3.82” × 1.61”) W18 × H106 × D110.5 mm (0.71” × 4.17” × 4.35”) W12 × H106 × D110.5 mm (0.47” × 4.17” × 4.35”) Standards & Approvals CE / UL / C-UL for selected models / RoHS for selected models CE / UL / C-UL for selected models / RoHS for selected models CE / UL / C-UL for selected models / RoHS CE for selected models / RoHS CE for selected models / RoHS CE / UL / C-UL for selected models / RoHS for selected models CE / RoHS for selected models Mini-M Series Mini-MW Series M6 Series M5-UNIT W5-UNIT M3-UNIT M3S-UNIT Input Loop Powered Isolator M2SN M6xSN M5SN Universal Input M2XU, M2XUM M6xXU M3LU2, M3LU DC Input M2XV2, M2LV, M2VS, M2FV M2VF, M2VF2, M2VF3, M2VV W2VS, W2VF M6xYV, M6xXV, M6xVS, M6xVF, M6xWVS M5VS, M5MV, M5VF, W5VSH W5VS, W5FV M3LV M3SYV, M3SXV, M3SVS, M3SWVS High Current Output Thermocouple Input M2XT2, M2TS W2XT, W2TS M6xXT M5TS W5TS M3LT M3SXT RTD Input M2XR2, M2LR, M2RS, M2RR W2XR, W2RS M6xXR M5RS W5RS M3LR M3SXR, M3SRS Potentiometer Input M2XM2, M2LPM, M2MS W2XM, W2MS M6xXM M5MS W5MS M3LM M3SXM, M3SMS Current Loop Supply M2D, M2D2, M2DYS, M2DY, M2DL, M2DNY, M2DYH2, M2DYH, M2DYHR, M2DU W2DYS, W2DY, W2DNY, W2DYH M6xDY M5DY W5DY M3LDY, M3DY M3SDY Self-Synch Input Strain Gauge Input M2LCS W5LCS M3LLC AC Input M2TG, M2AC W2TG, W2AC PT Input M2PA, M2PE W2PA, W2PE M5PT CT Input M2CA, M2CE, M2CEC W2CA, W2CE M6xCTC M5CT, M5CTC Power Transducer Frequency Input M2XPA3, M2SP W2SP M6xPA M5PA W5PA M3LPA2 Encoder Input M2XRP2 Frequency Output M2AP W2AP M6xAP Pulse Isolator M2PP W2PP M6xPP Pulse Scaler M2PRU P/I Transducer M2PV W2PV I/P Transducer Limit Alarm M2AVS, M2SED, M2AS, M2AS1 M6xXAS, M6xXAT, M6xXAR BCD Transducer Math Function M2ADS, M2SBS, M2MLS, M2DIS W2VABS M6xXF2 Ratio/Bias M2REB, M2RTS Process Function M2XF2, M2FL, M2FLS, M2LMS, M2UDS2, M2UDS W2XF M6xXF1 Filter/Lag M2CDS, M2CRS M6xXF1 Hold M2AMS2, M2AMS, M2PHS2, M2PHS M6xXF3 Signal Selector M2SES2, M2SES, M2MNV M6xXF2 Signal Generator M2MST Valve Positioner Control Backup Others Only typical models and specs are mentioned in this table. Please refer to the data sheet for the detailed specs. 2-Port Isolation Input Isolation 20VF-1 20VS2-1 20VS2-3 20VS4-384 20VS5-150 20VS5-200 20VS5-500 Output Isolation 20VF-2 20VS2-2 20VS2-4 20VS5-140 20VS5-170 Bidirectional Isolation 20VS5-100 3-Port Isolation 20VS1A 20VS2-01 20VS2-02 20VS3 20VS8-210

Transcript of 002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series...

Page 1: 002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice.ISP ’12

A

003

003A

002

002 Signal Conditioners Product Selection GuideSignal Conditioners Product Selection GuideSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal ConditionersProduct Selection Guide

Signal Conditioners

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

20 Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

Rack-mounted

10-RACK Series

18-RACK Series

38-RACK Series

Signal ConditionersProduct Selection Guide

Mini-M Series

Signal Conditioners

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

20 Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

Rack-mounted

18-RACK Series

38-RACK Series

Compact Plug-in Mini-M Series

Compact Plug-in Signal Splitters Mini-MW Series

Ultra-Slim M6 Series

Low Profile M5-UNIT Series

Low Profile Signal Splitters W5-UNIT Series

Thin Profile M3-UNIT Series

Thin Profile M3S-UNIT Series

Hybrid IC Isolation Amplifiers 20 Series

P.008 P.106 P.138 P.184 P.202 P.214 P.234 P.246

Construction Plug-in Plug-in Ultra-slim Terminal block Terminal block Front terminal access Front terminal access

Connection M3 screw terminal M3 screw terminal Tension-clamp, M3 screw terminal Euro terminal M3.5 screw terminal Input: M3.5 screw terminal

Output & power: M3 screw terminal Removable terminal block Removable terminal block

Isolation Three ways Four ways Three / four ways Three ways Four ways Three ways Three / Four ways

Dielectric Strength 2000V AC 2000V AC 2000V AC DC powered: 2000V AC AC powered: 1500V AC 2000V AC DC powered: 2000V AC

AC powered: 1500V AC 2000V AC

Range Selectability Specified when ordering or PC / One-Step Cal programming

Specified when ordering or PC programming

Specified when ordering or PC programming Specified when ordering Specified when ordering or

DIP switch programming PC / One-Step Cal programming Specified when ordering or PC programming

Dual Output – Yes Selected models – Yes – Selected models

Power Input AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC (universal)

Operating Temperature -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -20 to +55°C (-4 to +131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -25 to +65°C (-13 to +149°F) -10 to +55°C (14 to 131°F)

Mounting Surface or DIN rail Surface or DIN rail DIN rail DIN rail DIN rail DIN rail DIN rail

Dimensions W23 [29.5] × H76 × D124 mm (0.91” [1.16”] × 2.99” × 4.88”)

W29.5 × H89 × D124 mm (1.16” × 3.51” × 4.88”)

M6D/S: W5.9 × H94 × D102 mm (0.23” × 3.70” × 4.02”) M6N: W7.5 × H102 × D102 mm (0.30” × 4.02” × 4.02”)

W25 × H97 × D41 mm (0.98” × 3.82” × 1.61”)

W45 × H97 × D41 mm (1.77” × 3.82” × 1.61”)

W18 × H106 × D110.5 mm (0.71” × 4.17” × 4.35”)

W12 × H106 × D110.5 mm (0.47” × 4.17” × 4.35”)

Standards & Approvals CE / UL / C-UL for selected models / RoHS for selected models

CE / UL / C-UL for selected models / RoHS for selected models CE / UL / C-UL for selected models / RoHS CE for selected models / RoHS CE for selected models / RoHS CE / UL / C-UL for selected models /

RoHS for selected models CE / RoHS for selected models

Mini-M Series Mini-MW Series M6 Series M5-UNIT W5-UNIT M3-UNIT M3S-UNIT

Input Loop Powered Isolator M2SN – M6xSN M5SN – – –Universal Input M2XU, M2XUM – M6xXU – – M3LU2, M3LU –

DC Input M2XV2, M2LV, M2VS, M2FV M2VF, M2VF2, M2VF3, M2VV W2VS, W2VF M6xYV, M6xXV, M6xVS,

M6xVF, M6xWVSM5VS, M5MV, M5VF, W5VSH W5VS, W5FV M3LV M3SYV, M3SXV, M3SVS,

M3SWVSHigh Current Output – – – – – – –Thermocouple Input M2XT2, M2TS W2XT, W2TS M6xXT M5TS W5TS M3LT M3SXT

RTD Input M2XR2, M2LR, M2RS, M2RR W2XR, W2RS M6xXR M5RS W5RS M3LR M3SXR, M3SRSPotentiometer Input M2XM2, M2LPM, M2MS W2XM, W2MS M6xXM M5MS W5MS M3LM M3SXM, M3SMS

Current Loop SupplyM2D, M2D2, M2DYS, M2DY,

M2DL, M2DNY, M2DYH2, M2DYH, M2DYHR, M2DU

W2DYS, W2DY, W2DNY, W2DYH M6xDY M5DY W5DY M3LDY, M3DY M3SDY

Self-Synch Input – – – – – – –Strain Gauge Input M2LCS – – – W5LCS M3LLC –

AC Input M2TG, M2AC W2TG, W2AC – – – – –PT Input M2PA, M2PE W2PA, W2PE – M5PT – – –CT Input M2CA, M2CE, M2CEC W2CA, W2CE M6xCTC M5CT, M5CTC – – –

Power Transducer – – – – – – –Frequency Input M2XPA3, M2SP W2SP M6xPA M5PA W5PA M3LPA2 –Encoder Input M2XRP2 – – – – – –

Frequency Output M2AP W2AP M6xAP – – – –Pulse Isolator M2PP W2PP M6xPP – – – –Pulse Scaler M2PRU – – – – – –

P/I Transducer M2PV W2PV – – – – –I/P Transducer – – – – – – –

Limit Alarm M2AVS, M2SED, M2AS, M2AS1 – M6xXAS, M6xXAT, M6xXAR – – – –BCD Transducer – – – – – – –Math Function M2ADS, M2SBS, M2MLS, M2DIS W2VABS M6xXF2 – – – –

Ratio/Bias M2REB, M2RTS – – – – – –

Process Function M2XF2, M2FL, M2FLS, M2LMS, M2UDS2, M2UDS W2XF M6xXF1 – – – –

Filter/Lag M2CDS, M2CRS – M6xXF1 – – – –

Hold M2AMS2, M2AMS, M2PHS2, M2PHS – M6xXF3 – – – –

Signal Selector M2SES2, M2SES, M2MNV – M6xXF2 – – – –Signal Generator M2MST – – – – – –Valve Positioner – – – – – – –Control Backup – – – – – – –

Others – – – – – – –Only typical models and specs are mentioned in this table. Please refer to the data sheet for the detailed specs.

◆ 2-Port Isolation ❚ Input Isolation

20VF-120VS2-120VS2-320VS4-38420VS5-15020VS5-20020VS5-500

❚ Output Isolation20VF-220VS2-220VS2-420VS5-14020VS5-170

❚ Bidirectional Isolation20VS5-100

◆ 3-Port Isolation20VS1A20VS2-0120VS2-0220VS320VS8-210

Page 2: 002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice.ISP ’12

A

005

005A

004

004 Signal Conditioners Product Selection GuideSignal Conditioners Product Selection GuideSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal ConditionersProduct Selection Guide

Signal Conditioners

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

20 Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

Rack-mounted

10-RACK Series

18-RACK Series

38-RACK Series

Signal ConditionersProduct Selection Guide

Mini-M Series

Signal Conditioners

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

20 Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

Rack-mounted

18-RACK Series

38-RACK Series

Dual Output Super-mini Signal Conditioners Pico-M Series

Plug-in Front Configurable MX-UNIT Series

Plug-in M-UNIT Series

Plug-in Signal Splitters W-UNIT Series

Plug-in K-UNIT Series

Space-saving Plug-in F-UNIT Series

Space-saving Plug-in H-UNIT Series

Construction Connector on the base Plug-in Plug-in Plug-in Plug-in Plug-in Plug-in

Connection M3.5 screw terminal, DCS M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal

Isolation Four ways Three ways Three ways Four ways Three / four ways Three ways Three ways

Dielectric Strength 1500V AC 2000V AC 2000V AC 2000V AC 2000V AC 1000V AC 500V AC

Range Selectability Specified when ordering or PC programming Front key programming Specified when ordering or

PC / Programming unit programmingSpecified when ordering or

PC / Programming unit programming Specified when ordering Specified when ordering or PC / Programming unit programming

Specified when ordering or PC / Programming unit programming

Dual Output Yes – – Yes Selected models – –

Power Input AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC DC

Operating Temperature 0 to 55°C (32 to 131°F) -5 to +55°C (23 to 131°F) -5 to +60°C (23 to 140°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F)

Mounting Installation Base (Surface) Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail

Dimensions W17.5 × H48 × D75 mm (0.69” × 1.89” × 2.95”)

W50 × H80 × D123 [132] mm (1.97” × 3.15” × 4.84” [5.20”] )

W50 × H80 × D127 [136] mm (1.97” × 3.15” × 5” [5.35”] )

W50 × H80 × D136 mm (1.97” × 3.15” × 5.35”)

W50 × H80 × D123 [132] mm (1.97” × 3.15” × 4.84” [5.20”] )

W26 × H100 × D137 mm (1.02” × 3.94” × 5.39”)

W26 × H93 × D137 mm (1.02” × 3.66” × 5.39”)

Standards & Approvals CE for selected models / RoHS for selected models

CE for selected models /RoHS for selected models

CE / UL / C-UL for selected models /RoHS for selected models

CE for selected models / RoHS for selected models

CE for selected models /RoHS for selected models RoHS for selected models RoHS for selected models

Pico-M Series MX-UNIT M-UNIT W-UNIT K-UNIT F-UNIT H-UNIT

Input Loop Powered Isolator – – SN – KSN FSN HSNUniversal Input – – JUA – – – –

DC Input M8YV1, M8XV3, M8VS1, M8YS1, M8YC1 MXV, MXF JV, SV, SVF, CV, OT2, OR2, SVB WJV, WVS, WVS2, WVF KYV, KVS, KWVS,

KWVS2, KSF, KV FJV, FVS, FVF, FV HJV, HVS, HVF, HV

High Current Output – – VA, SVA, 99SVA – – – –Thermocouple Input M8XT3, M8TS1 MXT JT, TCS, OTT2, OTR2 WJT, WTS KTS, KWTS FJT, FTS HJT, HTS

RTD Input M8XR3, M8RS1 MXR JR, RB, RBS, DR, DRS, CVRTD WJR, WRS, WRS2 KR, KRS, KWRS, KWRS2 FJR, FR, FRS HJR, HR, HRSPotentiometer Input M8XM3, M8MS1 – JM, PM, PMS, CVR1, PM2W WJM, WMS, WMS2 KM, KMS, KWMS, KWMS2 FJM, FM, FMS HJM, HM, HMS

Current Loop Supply M8DY1 – DS, DS-48, DS-824, JDL, YVD, YVDU, FND, FNDS WDY, WDNY KD, KDY, KWDY, KWDNY,

KWLD FD, FJDL, FDY2, FDL, FDU HD, HJDL, HDY2, HDL, HDU

Self-Synch Input – MXS JS WJS – – –Strain Gauge Input M8LCS MXLC, MXLCF LC, LCS, LC2, LCS2, LCF, MLV – KG, KGS FLC, FLCS –

AC Input – – TG, AC WTG, WAC KTG, KAC FTG, FAC –PT Input M8PT – PT, PTPH, PTAF WPT KP, KPE, KPNA, KPNE FPA, FPE HPA, HPE

CT Input M8CT1, M8CTC – CTH, CTC, CTCS, CTS, CT, CTPH,CTAF WCT KCEC, KC, KCE,

KCNA, KCNE, KCEZ FCA, FCE HC, HCE

Power Transducer – – MUWT, MEWT, MEWTF, MERP, MEPF, MEPA, HZ

WEWT, WERP, WEPF, WEPA, WHZ – – –

Frequency Input M8PA1 MXPA JPA, JPA2, MPAU, JPQ2, EP, SP, JTY2 WJPA, WSP KEP, KSP, KPAU FJPA, FSP HJPA, HSPEncoder Input – – JRP2, JRQ2, RPPD – – – –

Frequency Output M8AP1 MXAP AP, APU, JARP, MTD – KAP, KAPU FAP HAP, HAPUPulse Isolator M8PP1 – PP, PPD, YPD, RPPD, MNS WYPD KMT, KYPD, KWYPD FPP HPPPulse Scaler – – JPR2, PRU, JFR2, PDU, JPS3 – KPRU – HPR

P/I Transducer – – PV – – – HPVI/P Transducer – – VP – – – HVP, HVPN

Limit Alarm M8SED1 –AS4V, AS4T, AS4R, AS4M, AS4CT,

AS4LC, MSEF, AS, ASW, ASW2, ASL, ASWL, ASWL2, AYAV, AYDV, ASD1, ASD

– KS2V, KS2TR, KSED, KSE, KS, KS2, KSL, KSL2 FAS, FASD HAS

BCD Transducer – – AD3V, AD2LC, DA3 – – – –Math Function – – JF, JFK, ADS, SBS, MLS, DIS WJF, WJFK, WADS KADS, KSBS, KMLS, KDIS FJF HJF

Ratio/Bias – – REB, REBS, RT, RTS – KB, KBS FRT, FRTS, FRTD –

Process Function – MXF JFX, JFX1, FN, FNS, LM, LMS, UD, UDS, MLG WJFX KX, KN, KNS, KL, KLS, KU, KUS FJFX, FFL, FLM, FLMS, FUD,

FUDS HJFX, HN

Filter/Lag M8CD1 – JFT, JFTS, CD, CDS, CR, CRS WJFT KF, KFS FJFT, FCR, FCRS HJFTHold – – AM, AMS, PH, PHS – KA, KAS, KH, KHS – –

Signal Selector – – SE, SES, JFKM, MNV – – FSE, FSES –Signal Generator – MXMS MS, MFS, MFS2 – – – –

Valve Positioner – – ABM, MP, MEX-B, MEX-C, MEX-D, MEX-E, MEX-F, MEX-M1 – – – –

Control Backup – MXAB, MXCB JB2, AB2, ABF3, CB2 – – – –Others – – MDC (Excitation Supply), ABS2 – – – –

Only typical models and specs are mentioned in this table. Please refer to the data sheet for the detailed specs.

Page 3: 002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice.ISP ’12

A

007

007A

006

006 Signal Conditioners Product Selection Guide Signal Conditioners Product Selection GuideSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal ConditionersProduct Selection Guide

Signal Conditioners

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

20 Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

Rack-mounted

10-RACK Series

18-RACK Series

38-RACK Series

Signal ConditionersProduct Selection Guide

Mini-M Series

Signal Conditioners

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

20 Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

Rack-mounted

18-RACK Series

38-RACK Series

Dual Output 10-RACK Series

DCS Front End 18-RACK Series

Interposing Relays 38-RACK Series

Construction Rack-mounted Rack-mounted Rack-mounted

Connection M3.5 screw terminal, DCS M3.5 screw terminal, DCS M3.5 screw terminal

Isolation Four ways Four ways –

Dielectric Strength 500V AC 1500V AC –

Range Selectability Specified when ordering or PC / Programming unit programming

Specified when ordering or PC / Programming unit programming –

Dual Output Yes Yes –

Power Input AC / DC AC / DC DC

Operating Temperature -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F)

Mounting Standard rack Standard rack Standard rack

Dimensions W25 × H99 × D180 mm (0.98” × 3.90” × 7.09”)

W24 × H110 × D110 mm (0.94” × 4.33” × 4.33”)

W24 × H110 × D110 mm (0.94” × 4.33” × 4.33”)

Standards & Approvals – – –

10-RACK 18-RACK 38-RACK

Input Loop Powered Isolator 10SN 18SNUniversal Input – –

DC Input 10VS4, 10YS, 10YK, 10JV, 10VS, 10VK, 10VF

18YS, 18YK, 18YC, 18JV, 18VS, 18VK

High Current Output – –Thermocouple Input 10JT, 10TS, 10TK 18JT, 18TS, 18TK

RTD Input 10JR, 10JRE, 10RS, 10RK 18JR, 18RS, 18RKPotentiometer Input 10JM, 10MS, 10MK 18JM, 18MS, 18MKCurrent Loop Supply 10D, 10JDL, 10DY, 10DNY, 10DU 18JDL, 18DY, 18JDN, 18DU

Self-Synch Input – –Strain Gauge Input 10LCS, 10LCK –

AC Input 10TG, 10AC 18TG, 18ACPT Input 10PA, 10PE 18PECT Input 10CA, 10CE 18CE

Power Transducer 10EWT, 10ERP, 10EPF, 10EPA, 10EHZ 18WT, 18RP, 18PF, 18PA, 18HZFrequency Input 10JPA, 10SP 18JPAEncoder Input – –

Frequency Output 10AP –Pulse Isolator 10PP 18PPPulse Scaler 10PR 18PR

P/I Transducer 10PV 18PVI/P Transducer 10VP, 10VPN 18VP

Limit Alarm 10AS 18AS2, 18AT, 18ARBCD Transducer – –Math Function 10JF 18JF

Ratio/Bias – –Process Function 10JFX, 10FNS 18JFX, 18JN

Filter/Lag 10JFT –Hold – –

Signal Selector – –Signal Generator – –Valve Positioner – –Control Backup 10ABS –

Others 10BOS 18DI, 18DO, 18APT, 18YVT

Visit M-System Web Site.

Only typical models and specs are mentioned in this table. Please refer to the data sheet for the detailed specs.

n PC Configurator SoftwareM-System’s PC Configurator programs are packed with advanced features. Not only the I/O ranging, but also linearization, fine calibration, filters, diagnostics are available depending on the signal conditioner’s function. In addition, many configurators are provided with monitoring and simulating functions to help you confirm the module’s proper operation, calibrate it at the field site and commissioning the receiving instrument at the same time.

This type of programming is especially convenient when an identical configuration setting is required for multiple modules. It saves you a considerable time by simply calling a pre-defined setting and downloading it from the PC software.

The PC configuration is available with various signal conditioner series including M2X, W2X, M3L, M3SX and M6X Series.

n “One-Step Cal” ConfigurationEven when you do not have a PC at your disposal, a simulator and a multimeter can help you program I/O ranges.

The internal DIP switches are used to configure input and output type. Once the module is configured, precise ranges can be set with the front control buttons using a simulator connected to the input terminals and a multimeter connected to the output terminals as a reference.

For example, suppose that the DIP switches are configured for the J type thermocouple. Turn the power supply to the transmitter on and press MODE button to enter to the Input Calibration Mode. Apply the desired minimum (e.g. 0°C) and maximum (e.g. 400°C) input levels and push the DOWN (zero) and UP (span) respectively to set the input range to 0 to 400°C. Then the output range can be calibrated in a similar manner after moving to the Output Calibration Mode.

The front LED’s colors and flashing patterns help you easily identify the transmitter’s status and confirm the setup actions in each step of Calibration Modes.

“One-Step Cal” configuration is available with the M3L and M2L Series signal conditioners.

n Front Control Buttons with Local DisplayThe MX Series signal conditioners and the AS4 Series limit alarms are provided with two displays on the front face: 4-digit DATA display and 2-digit ITEM display. Using Up/Down buttons, configuration is simple by calling parameters’ ID numbers (ITEM) and choosing values (DATA).

The M7E Series limit alarms are provided with a multi-line LCD display, which shows the parameters and selections in text to guide you through the programming procedure: intuitive, easy programming just like operating your mobile phone. You won’t need to consult the instruction manual.

These displays indicate process values once commissioned at the field site, and the soft-ware’s “programmable” mode can be locked out in order to prevent unwanted changes in the setting.

Configurable Signal Conditioners — Choose your way of configuration.

Basic Setting View Trend Graph View

MODE Button

DOWN Button

UP Button

LCD Display

Mode Button

Set Button

PC ConfiguratorJack

Up Button

Down ButtonITEM No. Display

DATA UP-DOWN Keys

ITEM No. UP-DOWN Keys

DATA Display

ProgrammingError LED

Polarity LED

MX Series Front Panel M7E Series Front Panel

Connect the M3LU to a simulator and a multimeter and to a power source.

SimulatorMultimeter

Power Source

Input Output

M3SX Series

M3L Series Front Panel

Page 4: 002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice.ISP ’12

B

253

253B

252

252 Two-wire Signal Conditioners Product Selection GuideTwo-wire Signal Conditioners Product Selection GuideSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Two-wire Product Selection Guide

27-UNIT Series

Two-w

ire Signal Conditioners

26-UNIT Series

B6-UNIT Series

B3-UNIT Series

B5-UNIT Series

6-UNIT Series

T-UNIT Series

B-UNIT Series

Two-wire Product Selection Guide

Two-w

ire Signal Conditioners

27-UNIT Series

26-UNIT Series

B6-UNIT Series

B3-UNIT Series

B5-UNIT Series

6-UNIT Series

T-UNIT Series

B-UNIT Series

Only typical models and specs are mentioned in this table. Please refer to the data sheet for the detailed specs.

Head-mount, Programmable 27-UNIT Series

Head-mount 26-UNIT Series

Field-mount B6-UNIT Series

DIN Rail Mount B3-UNIT Series

Low Profile B5-UNIT Series

Hockey-puck Style 6-UNIT Series

Compact Size T-UNIT Series

Space-saving, Plug-in B-UNIT Series

P.254 P.266 P.272 P.278 P.290

Construction Sensor head-mounting Sensor head-mounting Outdoor enclosure (IP65) Front terminal access Terminal block Hockey-puck style Stand-alone; terminal access at the front Plug-in

Connection M3 screw terminal Terminal block M3.5 screw terminal Removable terminal block M3.5 screw terminal M3 screw terminal DIN terminal block M3.5 screw terminal

Isolation Input to output Input to output Input to output to outdoor enclosure Input to output Input to output Input to output Input to output Input to output

Dielectric Strength 1500V AC 1500V AC 1500V AC 2000V AC 2000V AC 500V AC 500V AC 500V AC

Range Selectability PC or HART programming Specified when ordering HART (PC) programmingSpecified when ordering or

HART (PC) / PROFIBUS-PA (PC) / DIP switch programming

Specified when ordering Specified when ordering or DIP switch programming Specified when ordering Specified when ordering

Operating Temperature -40 to +85°C (-40 to +185°F)

-40 to +85°C (-40 to +185°F)

-40 to +85°C (-40 to +185°F)

-40 to +85°C(-40 to +185°F)

-40 to +80°C (-40 to +176°F)

-5 to +70°C (23 to 158°F)

-5 to +60°C (23 to 140°F)

-5 to +55°C (23 to 131°F)

Mounting Head mount or Field mount Head mount Field mount DIN rail DIN rail DIN rail

with mounting plate A-31 Surface or DIN rail Surface or DIN rail

Dimensions 44 dia. × 20.7 mm (1.732 dia. × 0.81”)

43.5 dia. × 26.5 mm (1.71 dia. × 1.04”) 110 (4.33”) dia. W18 × H106 × D110.5 mm

(0.71” × 4.17” × 4.35”)W25 × H97 × D41 mm (0.98” × 3.82” × 1.61”)

W76 × H52.5 × D61 mm(2.99” × 2.07” × 2.40”)

W25 × H60 × D70 mm (0.98” × 2.36” × 2.76”)

W26 × H93 × D137 mm (1.02” × 3.66” × 5.39”)

Standards & Approvals CE / ATEX / FM / SIL2, RoHS for selected models

CE / ATEX for selected models / RoHS CE / ATEX / FM / SIL CE / UL / C-UL /

ATEX, FM, RoHS for selected models CE / RoHS – – CE for selected models

27-UNIT 26-UNIT B6-UNIT B3-UNIT B5-UNIT 6-UNIT T-UNIT B-UNIT

Input Loop Powered Isolator – – – – B5SN 6SN TSN BSN

DC Input – – – B3VS/1 (single channel) B3VS/2 (dual channel) B5VS – TV, TVS BV, BVS

DC Input (programmable) – – – B3FV – 6VS – –

Universal Temperature Input(HART, outdoor enclosure) 27HU-B – B6U-B – – – – –

Universal Temperature Input (HART) 27HU – B6U B3HU – – – –

Universal Temperature Input (PROFIBUS-PA) – – – B3PU – – – –

Universal Temperature Input 27U – – – – – – –Thermocouple Input – 26TS1 – – B5TS 6TS – BT, BTSThermocouple Input

(programmable) 27TS – – B3FT – 6TS1 – –

RTD Input – 26REX, 26R1, 26RS – – B5RS – TR BRRTD Input

(programmable) 27R, 27RS – – B3FR – 6R – –

Potentiometer Input 27PM – – – B5MS 6M TM BMStrain Gauge Input – – – – – 6LC – BLC

Frequency Input – – – – – – – BSPFrequency Input (programmable) – – – B3FP – 6PA – –

Square Root Extractor – – – – – 6FN – –AC Input – – – – – 6AC – –PT Input – – – – – 6PT – BPTCT Input – – – – – 6CT – BCT

P/I Transducer – – – – – – TPV BPV

6BX-E

Page 5: 002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice.ISP ’12

C

299

299C

298

298 Power Transducers Products Selection GuidePower Transducers Products Selection GuideSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Power Transducers Product Selection Guide

LT-UNIT Series

Power Transducers

54U /53U /52U /51U

L-UNIT Series

LSMT4

K-UNIT Series

CLS Series

Power TransducersProduct Selection Guide

Power Transducers

LT-UNIT Series

54U /53U /52U /51U

L-UNIT Series

LSMT4

K-UNIT Series

CLS Series

M4 Screw Connection LT-UNIT Series

M3.5 Screw Connection L-UNIT Series

Plug-in K-UNIT Series

P.300

Construction Terminal access at the front Terminal access at the front Plug-in

Connection M4 screw terminal M3.5 screw terminal M3.5 screw terminal

Dielectric Strength 2000V AC 2000V AC 2000V AC

Auxiliary Power AC / DC AC / DC AC / DC

Self Powered Type Available Available Available

Operating Temperature -10 to +55°C (14 to 131°F)

-10 to +55°C (14 to 131°F)

-10 to +55°C (14 to 131°F)

Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail

Dimensions W39 [72] × H111 × D143 mm (1.54” [2.83] × 4.37” × 5.63”)

W75 × H80 × D112 mm (2.95” × 3.15” × 4.41”)

W50 [72] × H80 × D123 [132] mm (1.97” [5.20”] × 3.15” × 4.84” [2.83”])

IEC 60688 Yes – –

Standards & Approvals CE / RoHS for selected models RoHS for selected models RoHS for selected models

LT-UNIT L-UNIT K-UNIT

n PT TransducerAverage – LPNA KP, KPNA

RMS LTPE LPE, LPNE KPE, KPNE2 channels, Average – L2PA, L2PNA –

2 channels, RMS – L2PE, L2PNE –3 channels – L3PK –

n CT TransducerClamp-on Current Sensor;

RMS sensing LTCEC – KCEC

Average – LCNA KC, KCNARMS LTCE, LTCNE LCE, LCNE KCE, KCNE

2 channels, Average – L2CA, L2CNA –2 channels, RMS – L2CE, L2CNE –

3 channels – L3CK –

n PT/CT TransducerAverage – LPCA –

RMS – LPCE –

n Watt / Var / Power Factor / Phase Angle / Frequency / Bidirectional Current Transducer

Watt LTWT, LTWTN LWT, LWTNKEWT, KEWTN,KUWT, KUWTN,KUWE, KUWEN

Var LTRP, LTRPN LRP, LRPN KERP, KERPN,KURE, KUREN

Power Factor LTPF, LTPFN LPF, LPFN KEPF, KEPFNPower Factor

(for unbalanced load) LTPFU, LTPFUN LPFU, LPFUN KEPFU, KEPFUN

Phase Angle(self-powered) LTPA, LTPAN LPA, LPAN KEPA, KEPAN

Phase Angle(for unbalanced load) LTPAU, LTPAUN LPAU, LPAUN KEPAU, KEPAUN

Frequency LTHZ, LTHZN LHZ, LHZN KEHZ, KEHZNBidirectional Current – LCY –

Phase Angle(between two voltages) – LPD –

n ZCT TransmitterZCT

(zero-phase current transformer) – – KCEZ

n Limit AlarmQuad DC Alarm – L4AS –

Multi Power Monitor 53U

Multi Power Monitor 54U / 54UC / 54UL

P.328 P.329

Construction 96-mm square (1/4 DIN size) 110-mm square panel flush mounted

Connection;Voltage input Connector type terminal block M4 screw terminals (torque 1.4 N·m)

Dielectric Strength 2500V AC 2000 V AC @ 1 minute

Auxiliary Power AC / DC (universal) AC / DC (universal)

Operating Temperature -10 to +55°C (14 to 131°F)

-10 to +55°C (14 to 131°F)

Mounting Panel Flush Mounting Panel flush mounting

Dimensions W96 × H96 × D115 mm (3.78” × 3.78” × 4.53”)

W110 × H110 × D125* mm (4.33” × 4.33” × 4.92”)

Degree of protection IP 52 (Front panel) IP 52 (Front panel)

Standards & Approvals CE / RoHS RoHS

Configuration Single-phase / 2-wire and 3-wire,3-phase / 3-wire and 4-wire Single-phase / 2-wire and 3-wire, 3-phase / 3-wire and 4-wire

External Interface

•Modbus, Do × 1, Di × 1• 4 – 20mA DC × 4• 1 – 5V DC × 4• 4 – 20mA DC × 2, Do × 1, Di × 1• 1 – 5V DC × 2, Do × 1, Di × 1• 4 – 20mA DC × 2, Do × 2• 1 – 5V DC × 2, Do × 2•Modbus, Do × 3•Do × 4

54U 54UC 54UL

•Modbus, Do × 1, Di × 1• 4 – 20 mA DC × 4, Do × 1, Di × 11 – 5V DC × 4• 1 – 5 V DC × 4, Do × 1, Di × 1• Modbus, Do × 2• 4 – 20 mA DC × 4, Do × 2• 1 – 5 V DC × 4, Do × 2• 4 – 20 mA DC × 4 (isolated), Do × 1, Di × 1• 1 – 5 V DC × 4 (isolated), Do × 1, Di × 1• 4 – 20 mA DC × 4 (isolated), Do × 2• 1 – 5 V DC × 4 (isolated), Do × 2

• CC-Link, Do × 1, Di × 1• CC-Link, Do × 2

• LONWORKS, Do × 1, Di × 1• LONWORKS, Do × 2

Multi Power Transducer LSMT4

Multi Power Transducer L53U

P.328

Construction Terminal access at the front

Connection;Voltage input

M4 screw terminals (torque 1.4 N·m) Connector type terminal block

Dielectric Strength 2000V AC 2500V AC

Auxiliary Power AC / DC

Operating Temperature -10 to +55°C (14 to 131°F)

Mounting Surface or DIN rail DIN rail

Dimensions W125 × H140 × D116 mm(4.92” × 5.51” × 4.57”)

W60 × H105 × D120 mm (2.36” × 4.13” × 4.72”)

Standars & Approvals RoHS

Configuration Single-phase / 2-wire and 3-wire,3-phase / 3-wire and 4-wire

Single-phase / 2-wire and 3-wire, 3-phase / 3-wire and 4-wire

Output

Current Voltage

•Modbus, Do × 1, Di × 1 • 4 – 20 mA DC × 4 • 1 – 5 V DC × 4

4 – 20mA DC 0 – 10V DC0 – 5V DC1 – 5V DC

Energy count output

Only typical models and specs are mentioned in this table. Please refer to the data sheet for the detailed specs.

P.335

Clamp-on Current Sensor CLS Series

* 140 (5.51") for Configuration code 2

Page 6: 002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice.ISP ’12

D

339

339D

338

338 Indicators Product Selection GuideIndicators Product Selection GuideSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Indicators Product Selection Guide

Bargraph Indicators

47 Series Digital Panel Meters

40 Series

46 Series

6DV Series

43 Series

IndicatorsProduct Selection Guide

Bargraph Indicators

Digital Panel Meters

47 Series

40 Series

46 Series

6DV Series

43 Series

Bargraph Indicator 48NV

Bargraph Indicating Alarm 48NAVx

Bargraph Indicating Alarmwith 4-digit digital meter

48NDVx

Bargraph Indicating Alarm(Sensor Input)

48NAx

Bargraph Indicating Alarm with 4-digit digital meter (Sensor Input)

48NDx

Bargraph Indicator 48SV

Bargraph Indicating Alarm 49AV2

P.342 P.342 P.342 P.342 P.342 P.342 P.343

Bargraph 101-segment LED 101-segment LED 101-segment LED 101-segment LED 101-segment LED 51-segment LED 51-segment LED

Scale Length 100 mm (3.96”) long,3.00 mm (.12”) wide

100 mm (3.96”) long,3.00 mm (.12”) wide

100 mm (3.96”) long,3.00 mm (.12”) wide

100 mm (3.96”) long,3.00 mm (.12”) wide

100 mm (3.96”) long,3.00 mm (.12”) wide 50 mm (1.97”) long 89 mm (3.50”) long,

angle 120°

Scale Custom Custom Custom Custom Custom 0 – 100% 0 – 100%

Bar Color Red, Amber, Green, Blue Red, Amber, Green, Blue, Multi-color

Red, Amber, Green, Blue, Multi-color

Red, Amber, Green, Blue, Multi-color

Red, Amber, Green, Blue, Multi-color Red Multi-color

(Red, Orange and Green)

Digital Meter – – 4 digits, Red LED – 4 digits, Red LED – 4 digits, Red LED

Connection M3 screw terminal M3 screw terminal M3 screw terminal M3 screw terminal M3 screw terminal Connector(leadwires soldered) M4 screw terminal

Direct Sensor Input – – – Yes Yes – –

Alarm Output – 2 or 4 points 2 or 4 points 2 or 4 points 2 or 4 points – 2 or 4 points

Power Input AC / DC AC / DC AC / DC AC / DC AC / DC DC AC / DC

Mounting Direction Vertical / Horizontal Vertical / Horizontal Vertical Vertical / Horizontal Vertical Vertical / Horizontal Vertical

Dimensions W36 × H144 × D103 mm(1.42” × 5.67” × 4.06”)

W36 × H144 × D103 mm(1.42” × 5.67” × 4.06”)

W36 × H144 × D103 mm (1.42” × 5.67” × 4.06”)

W36 × H144 × D103 mm(1.42” × 5.67” × 4.06”)

W36 × H144 × D103 mm(1.42” × 5.67” × 4.06”)

W18 × H72 × D118 mm (0.71” × 2.83” × 4.65”)

W96 × H96 × D116 mm (3.78” × 3.78” × 4.61”)

Degree of Protection IP65 front cover IP65 front cover IP65 front cover IP65 front cover IP65 front cover – –

Standards & Approvals CE / RoHS CE / RoHS CE / RoHS CE / RoHS CE / RoHS – –

48NV 48NAVx 48NDVx 48NAx 48NDx 48SV 49AV2

n Bargraph IndicatorDC Input 48NV – – – – 48SV –

n Bargraph Indicating AlarmDC Input – 48NAV – – – – –

Transmitter Output – 48NAVA – – – – –2-wire Transmitter Excitation – 48NAVD – – – – –

Thermocouple Input – – – 48NAT – – –RTD Input – – – 48NAR – – –

Potentiometer Input – – – 48NAM – – –

n Bargraph Indicating Alarm (with 4-digit digital meter)DC Input – – 48NDV – – – 49AV2

Transmitter Output – – 48NDVA – – – –2-wire Transmitter Excitation – – 48NDVD – – – –

Thermocouple Input – – – – 48NDT – –RTD Input – – – – 48NDR – –

Potentiometer Input – – – – 48NDM – –

Page 7: 002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice.ISP ’12

D

341

341D

340

340 Indicators Product Selection GuideIndicators Product Selection GuideSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Indicators Product Selection Guide

Bargraph Indicators

47 Series Digital Panel Meters

40 Series

46 Series

6DV Series

43 Series

IndicatorsProduct Selection Guide

Bargraph Indicators

Digital Panel Meters

47 Series

40 Series

46 Series

6DV Series

43 Series

* 42mm (1.65”) for one block terminal

LCD Display 47D Series

LED Display 47L Series

LED Display 40 Series

LED Display 46 Series

Small Size 43DV2/43DV1

Loop Powered 6DV/6DVI

Loop Powered 6DV-B/6DVI-B

Loop Powered 43AL Series

P.372 P.373 P.408 P.408 P.418 P.412 P.412 P.418

Display 5 1/2 digitsRed / Green LCD

4, 4 1/2 or 6 digits Red, Orange, Green,

Bluegreen, Blue, White LED(47LYV: Red/Orange only)

3 1/2 digits (40LV) , 4 digits (40DV, 40DR)

Red LED

4 digitsRed / Green LED

4 digitsRed LED

3 1/2 digitsRed LED

4 digitsRed LED

4 digitsRed LED

4 digitsRed LED

3 1/2 digitsRed LED

ConnectionM3 screw terminal /

Euro Type Connector Terminal / 50-pin connector

M3 screw terminal M3 screw terminal M3 screw terminal

Screwless spring terminal or Separable screwless

spring terminal

Connector(leadwires soldered)

Euro terminal Euro terminal block or M3 screw terminal

Screwless spring terminal or Separable

screwless spring terminal

Terminal block Euro terminal

Scaling Yes Yes Yes (40DV only) – Yes Yes Yes Yes

Direct Sensor Input Yes Yes Yes – – – – –

Alarm Output Optional, 2 or 4 points Optional, 2 or 4 points – Optional, 2 or 4 points – – – –

BCD Output Optional – – Optional – – – –

Network Interface Optional, RS-485 / Modbus RTU – – Optional – – – –

Analog Output Optional Optional for selected models – Optional – – – –

Power Input AC / DC AC / DC AC (40DV) / DC AC / DC DC None None None

Dimensions W96 × H48 × D98.5 mm(3.78” × 1.89” × 3.88”)

W96 × H48 × D98.5 mm(3.78” × 1.89” × 3.88”)

W96 × H48 × D96 mm(3.78” × 1.89” × 3.78”)

W102.5 × H48 × D104 mm(4.04” × 1.89” × 4.09”)

W48 × H24 × D42*, 58 mm

(1.89” × 0.94” × 1.65”, 2.28”)

W48 × H24 × D72 mm

(1.89” × 0.94” × 2.83”)

70 (2.76”) dia. 110 (4.33”) dia.

W48 × H24 × D42*, 58 mm

(1.89” × 0.94” × 1.65”, 2.28”)

W48 × H24 × D40 mm

(1.89” × 0.94” × 1.57”)

110 (4.33”) dia.

Degree of Protection IP66 front panel IP66 front panel – – – – IP66 / IP67 – IP66 / IP67

Standards & Approvals RoHS CE for selected models / RoHS CE / RoHS – CE / RoHS – CE / ATEX / FM / RoHS CE / ATEX / FM / RoHS CE / RoHS CE / UL / RoHS CE / ATEX / FM

47D Series 47L Series 40 Series 46 Series 43DV Series 6DV Series 6DV-B Series 43AL Series

DC Input (indicator only) – 47LYV 40LV, 40DV 46DL2 43DV2, 43DV1 – – 43AL1, 43AL

DC Input (indicator only / intrinsically safe)

– – – – – 6DV, 6DVI – –

DC Input (indicator only / explosion-proof)

– – – – – – 6DV-B, 6DVI-B 43AL-B

DC Input 47DV 47LV – 46DV2 – – – –Thermocouple Input 47DT 47LT – – – – – –

RTD Input 47DR 47LR 40DR – – – – –Potentiometer Input 47DM 47LM – – – – – –

AC Input 47DAC 47LAC – – – – – –Strain Gauge Input – 47LLC – – – – – –

VT Input – 47LPT – – – – – –CT Input – 47LCT – – – – – –

Frequency Input – 47LPA, 47LHZ, 47LPQ – – – – – –

43DV2 43DV1 43AL1 43AL

43AL-B

Page 8: 002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT

Limit Alarms Product Selection Guide

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice.ISP ’12

E

425

425E

424

424 Limit Alarms Product Selection GuideSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Limit AlarmsProduct Selection Guide

Limit AlarmsProduct Selection Guide

n Digital Adjustments n Digital Adjustments n Rotary Switch / Potentiometer / Various Setpoint AdjustmentsDigital Adjustments

AS4 SeriesLCD Display

M7E-UNIT SeriesUltra-Slim

M6 Series MSEFRotary Switch Adj. AL-UNIT Series

Potentiometer Adj. A-UNIT Series

Three-turn screwdrivers, Remote dial potentiometer or DC input

M-PAC Series

Construction Plug-in Plug-in Ultra-slim Plug-in Plug-in Plug-in Plug-in

Connection M3.5 screw terminal M3 screw terminalTension-clamp (M6S),

M3 screw terminal (M6N), Euro terminal (M6D)

M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal

Isolation Input to output to power Input to output to power Input to output to power Input to output to power Input to output to power Input to output to power Input to output to powerDielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 1000V AC

Input Range Selectability Front key programming Front control buttons or PC software

Specified when ordering or PC programming Front control buttons Specified when ordering Specified when ordering Specified when ordering

No. of Alarm Point 2, 4 2, 4 1 2 2 2 1 or 2Relay Form Dual SPDT or Quad NO or NC Dual SPDT or Quad NO or NC SPDT SPDT SPDT SPDT SPDT or DPDT

Alarm Setting Front key programming Front control buttons or PC software PC software Front control buttons 10-position rotary switches 270°-turn screwdrivers

Three-turn screwdrivers, Remote dial potentiometer or

DC inputAlarm Setpoint 0 – 100% 0 – 100% -2 to +102% -14 to +113.5% 0 – 99% 0 – 100% 0 – 100%

Deadband (Hysteresis) Adj. FS FS 0 – 99.9999% 0.5 – 15% – 1 – 100% 1 – 100%Latching Output Yes Yes – Yes – – Yes

Setpoint Accuracy ±0.1% FS ±0.1% FS ±0.05% FS ±0.5% ±0.5% ±0.5% ±0.2%Alarm Test – Yes Yes – – – –DC Output – – – – – – Optional

Power Input AC / DC AC / DC DC AC / DC AC / DC AC / DC AC / DC

Operating Temperature -5 to +55°C (23 to 131°F)

-5 to +55°C (23 to 131°F)

-20 to +55°C (-4 to +131°F)

-5 to +55°C (23 to 131°F)

-5 to +60°C (23 to 140°F)

-5 to +60°C (23 to 140°F)

-5 to +60°C (23 to 140°F)

Mounting Surface or DIN rail Surface or DIN rail DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface (DIN rail available for 11-pin base)

Dimensions W50 × H80 × D132 mm(1.97” × 3.15” × 5.20”)

W29.5 × H83 × D124 mm(1.16” × 3.27” × 4.88”)

M6D/S : W5.9 × H94 × D102 mm (0.23” × 3.70” × 4.02”) M6N : W7.5 × H102 × D102 mm (0.30” × 4.02” × 4.02”)

W50 × H80 × D136 mm (1.97” × 3.15” × 5.35”)

W50 × H80 × D132 mm (1.97” × 3.15” × 5.20”)

W50 × H80 × D132 mm (1.97” × 3.15” × 5.20”)

W50 × H80 × D132 mm(1.97” × 3.15” × 5.20”)

W80 × H101 × D136 mm (3.15” × 3.98” × 5.35”)

Standards & Approvals CE / UL / C-UL for selected models / RoHS for selected models CE / RoHS CE / RoHS CE / UL / C-UL RoHS for selected models – –

AS4 Series M7E-UNIT M6 Series MSEF AL-UNIT A-UNIT M-PAC

DC Input AS4V M7EASV M6SXAS, M6NXAS, M6DXAS MSEF ALV ACV MP1000Thermocouple Input AS4T – M6SXAT, M6NXAT, M6DXAT – ALT ATC MP1200

RTD Input AS4R – M6SXAR, M6NXAR, M6DXAR – ALR ARB MP1400Potentiometer Input AS4M – – – ALM APOT MP1800Two-wire Transmitter – M7EASDY – – ALDY, ALDN ADY, ADN MP1100Strain Gauge Input AS4LC – – – – – –

AC Input – – – – ALTG, ALAC ATG, AAC MP1600PT Input – – – – ALPT APTA, APTE –CT Input AS4CT – – – ALCT ACTA, ACTE –

Frequency Input – – – – ALSP ASP MP1700Others – – – – ALNR (Angle Sensor) ANR (Angle Sensor) –

Front View

L1

L2

L3

L4ALARM

DATA

ITEM

DATAITEM

ITEM No. Display

DATA UP-DOWN KeysITEM No. UP-DOWN Keys

Monitor LEDs

DATA Display

LCD Display

Mode ButtonSet ButtonPC ConfiguratorJack

Up ButtonDown Button Up

Down

Mode

Set

No.1 Setpoint Rotary SW (x10%)No.1 Setpoint Rotary SW (x1%)No.2 Setpoint Rotary SW (x10%)No.2 Setpoint Rotary SW (x1%)

No.1 LED

No.2 LED

No.1 LED

No.1 Hysteresis (Deadband) Adj.No.2 Hysteresis (Deadband) Adj.

No.2 LED

No.1 Setpoint Adj.

No.2 Setpoint Adj.

Zero Adj.

Span Adj.No.1 LED

No.1 Hysteresis (Deadband) Adj.No.2 Hysteresis (Deadband) Adj.

No.2 LED

No.1 Setpoint Adj.

No.2 Setpoint Adj.

Zero Adj.

Span Adj.

Status Indicator LED

Alarm Monitor LED

Configurator Jack

Power LED

MODE Selector

Digital Display

DOWN ControlUP Control

L1 MonitorLED

L2 MonitorLED

Only typical models and specs are mentioned in this table. Please refer to the data sheet for detailed specs.

AS4V,AS4T,AS4R,AS4M,AS4LC,AS4CT,M7EASV,M7

EASDY,M6SXAS,M6NXAS,M6DXAS,M6SXAT,M6NX

AT,M6DXAT,M6SXAR,M6NXAR,M6DXAR,

AS4V,AS4T,AS4R,AS4M,AS4LC,AS4CT,M7EASV,M7EASDY,M6SXAS,M6NXAS,M6DXAS,M6SXAT,M6NXAT,M6DXAT,M6SXAR,M6NXAR,M6DXAR,

MSEF,ALV,ALT,ALR,ALM,ALDY,ALDN,ALTG,ALAC,ALPT,ALCT,ALSP,ALNR,ACV,ATC,ARB,APOT,ADY,ADN,ATG,AAC,APTA,APTE,ACTA,ACTE,ASP,ANR,MP1000,MP1200,MP1400,MP1800,-MP1100,MP1600,MP1700

MSEF,ALV,ALT,ALR,ALM,ALDY,ALDN,ALTG,ALAC,ALP

T,ALCT,ALSP,ALNR,ACV,ATC,ARB,APOT,ADY,ADN,AT

G,AAC,APTA,APTE,ACTA,ACTE,ASP,ANR,MP1000,MP1

200,MP1400,MP1800,MP1100,MP1600,MP1700

Page 9: 002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT

Limit Alarms Product Selection GuideLimit Alarms Product Selection Guide

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice.ISP ’12

E

427

427E

426

426Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Limit AlarmsProduct Selection Guide

Limit AlarmsProduct Selection Guide

n Potentiometer / Dial Adjustments n Thumbwheel Switch Adjustments

M2AVS KSE L4ASExtra DC Output

AE-UNIT Series ASD1 KSED M2SED

Construction Plug-in Plug-in Discrete box; terminal access at the front Plug-in Plug-in Plug-in Plug-in

Connection M3 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3 screw terminal

Isolation Input to output to power Input to output to power Input to output to power Input to DC output to relay output to power Input to output to power Input to output to power Input to output to power

Dielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 2000V ACInput Range Selectability Specified when ordering Specified when ordering Specified when ordering Specified when ordering Specified when ordering Specified when ordering Specified when ordering

No. of Alarm Point 2 1, 2 2, 4 2 2 2 2Relay Form NO SPDT SPDT SPDT SPDT SPDT SPDT

Alarm Setting Multi-turn screwdriver Dials Single-turn screwdrivers or dials Thumbwheel switches Thumbwheel switches Thumbwheel switches Thumbwheel switchesAlarm Setpoint 0 – 100% -15 to +120% -15 to +115% 0 – 99% 0 – 99% 0 – 99% 0 – 99%

Deadband (Hysteresis) Adj. – – – 9% 14% – –Latching Output – – – – Yes – –

Setpoint Accuracy ±0.5% (monitor 0 – 1V) ±0.3% ±0.3% ±0.5% ±0.5% ±0.5% ±0.5%Alarm Test – – – – – – –DC Output – – – Yes – – –

Power Input AC / DC AC AC / DC AC / DC AC AC AC / DC

Operating Temperature -5 to +55°C (23 to 131°F)

-5 to +55°C (23 to 131°F)

-5 to +55°C (23 to 131°F)

-5 to +55°C (23 to 131°F)

-5 to +60°C (23 to 140°F)

-5 to +55°C (23 to 131°F)

-5 to +55°C (23 to 131°F)

Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail

Dimensions W23 × H76 × D124 mm (0.91” × 2.99” × 4.88”)

KSE-x1: W50 × H80 × D136 mm (1.97” × 3.15” × 5.35”) KSE-x2: W50 × H80 × D145 mm (1.97” × 3.15” × 5.71”)

W75 × H80 × D112 mm (2.95” × 3.15” × 4.41”)

D126 mm (4.96”) with dial adjustments

W72 × H80 × D132 mm (2.83” × 3.15” × 5.20”)

W50 × H80 × D132 mm (1.97” × 3.15” × 5.20”)

W50 × H80 × D132 mm(1.97” × 3.15” × 5.20”)

W29.5 × H76 × D124 mm (1.16” × 2.99” × 4.88”)

Standards & Approvals CE / RoHS CE RoHS – CE / UL / C-UL / RoHS CE / UL / C-UL / RoHS CE / UL / C-UL / RoHS

M2AVS KSE L4AS AE-UNIT ASD1 KSED M2SED

DC Input M2AVS KSE-x1, KSE-x2 L4AS AEV,AEAD (two-input addition) ASD1 KSED M2SED

Thermocouple Input – – – AET – – –RTD Input – – – AER – – –

Potentiometer Input – – – AEM – – –Two-wire Transmitter – – – AEDY, AEDN – – –Strain Gauge Input – – – – – – –

AC Input – – – AETG, AEAC – – –PT Input – – – AEPT – – –CT Input – – – AECT – – –

Frequency Input – – – AESP – – –Others – – – – – – –

Front View

Monitor LED•Output 1

Setpoint Adj.9 9

Setpoint Adj.•Output 2

9 9

Monitor LED

Deadband & Latching Control

Deadband & Latching Control

Hi Monitor LED

Hi Setpoint Adj.

Lo Setpoint Adj.

Lo Monitor LED

9 9

9 9

Hi Monitor LED

Hi Setpoint Adj. Dial

100

50 %

0

■ KSE-x1

Lo Monitor LED

Hi Setpoint Adj. Dial

Lo Setpoint Adj. Dial

Hi Monitor LED

100

50 %

SET1

0100

50 %

SET20

■ KSE-x2

1 2 3 4

Monitor LED

Setpoint Adj.

■ Dial Adjustments

1 2 3 4

Monitor LED

Setpoint Adj.

■ Screwdriver Adjustments

1 2 3 4

Monitor LED

Setpoint Adj.

■ Dial Adjustments

1 2 3 4

Monitor LED

Setpoint Adj.

■ Screwdriver Adjustments

Hysteresis (Deadband)Adj. Thumbwheel SW

Setpoint Adj.Thumbwheel SW

Monitor LED

Monitor LEDHysteresis (Deadband)Adj. Thumbwheel SW

• Output 2

• Output 1

Setpoint Adj.Thumbwheel SW

9 99

9 99

Span Adj.Zero Adj.

Output 1 Setpoint Adj.

Output 2 Setpoint Adj.

Output 1 Monitor LED

Output 2 Monitor LED

9 9

9 9

Output 2Setpoint Adj.

Output 2Monitor LED

Output 1Setpoint Adj.

Output 1Monitor LED

Output 2Setpoint Monitor (A2) COM

Output 1Setpoint Monitor (A1)

Only typical models and specs are mentioned in this table. Please refer to the data sheet for detailed specs.

M2AVS,KSE1,KSE2,L4AS M2AVS,KSE1,KSE2,L4AS

AEV,AEAD,AET,AER,AEM,AEDY,AEDN,

AETG,AEAC,AEPT,AECT,AESP,ASD1,K

SED,M2SED

AEV,AEAD,AET,AER,AEM,AEDY,AEDN,AETG,AEAC,AEPT,AECT,AESP,ASD1,KSED,M2SED

Page 10: 002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT

Limit Alarms Product Selection Guide

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

E

428

428Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Limit AlarmsProduct Selection Guide

n Thumbwheel Switch Adjustments n Deviation Alarm

M2AS M2AS1 AYDV

Construction Plug-in Plug-in Plug-inConnection M3 screw terminal M3 screw terminal M3.5 screw terminal

Isolation Input to output to power Input to output to power Input to output to powerDielectric Strength 2000V AC 2000V AC 2000V AC

Input Range Selectability Specified when ordering Specified when ordering Specified when orderingNo. of Alarm Point 1 1 2

Relay Form DPDT SPDT SPDTAlarm Setting Thumbwheel switches Thumbwheel switches Multi-turn screwdriversAlarm Setpoint 0 – 99% 0 – 99% -50 to +50%

Deadband (Hysteresis) Adj. FS FS –Latching Output Yes Yes –

Setpoint Accuracy ±0.5% ±0.5% ±0.5%Alarm Test – – –DC Output – – –

Power Input AC / DC AC / DC AC / DC

Operating Temperature -5 to +55°C (23 to 131°F)

-5 to +55°C (23 to 131°F)

-5 to +60°C (23 to 140°F)

Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail

Dimensions W29.5 × H76 × D124 mm (1.16” × 2.99” × 4.88”)

W23 × H76 × D124 mm (0.91” × 2.99” × 4.88”)

W50 × H80 × D132 mm (1.97” × 3.15” × 5.20”)

Standards & Approvals CE / RoHS CE / RoHS –

M2AS M2AS1 AYDV

DC Input M2AS M2AS1 AYDVThermocouple Input – – –

RTD Input – – –Potentiometer Input – – –Two-wire Transmitter – – –Strain Gauge Input – – –

AC Input – – –PT Input – – –CT Input – – –

Frequency Input – – –Others – – –

Front View Setpoint 1 Adj. & LED

Setpoint 2 Adj. & LED

Setpoint 2 Monitor

Setpoint 1 Monitor

COM.

Output Setpoint Adj.

Deadband Adj.

Output Monitor LED

Reset Control

9 9

9 9

Output Setpoint Adj.

Deadband Adj.

Output Monitor LED

Reset Control

9 9

9 9

M2AS,M2AS1,AYDV M2AS,M2AS1,AYDV

Page 11: 002A Product Selection Guide Signal Conditioners Product ... · M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series 20 Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice.ISP ’12 431430

F431F430 Gateway, Remote I/O Product Selection GuideGateway, Remote I/O Product Selection GuideSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Gateway, Remote I/OProduct Selection Guide

Gateway, Rem

ote I/O

R6 Series

R7 Series

R3 Series

R5 Series

R1 Series

60-UNIT Series

61-UNIT Series

M2BC / M2BD

D3 Series

DLA Series

Gateway, Remote I/OProduct Selection Guide

R6 Series

Gateway, Rem

ote I/O

R7 Series

R3 Series

R5 Series

R1 Series

60-UNIT Series

61-UNIT Series

M2BC / M2BD

D3 Series

DLA Series

R3-BS,R3-BSW,R3-US4,R3-SV4,R3-SV4A,R3-SV4B,R3-

SV4C,R3-SV8,R3Y-SV8,R3-SV8A,R3-SV8B,R3-SV8C,R3-

SV8N,R3Y-SV8N,R3S-SV8N,R3-SV16N,R3Y-SV16,R3-

SS4,R3-SS8,R3Y-SS8,R3-SS8N,R3Y-SS8N,R3S-

SS8N,R3-SS16N,R3Y-SS16N,R3-YV4,R3S-YV4,R3-

YV8,R3Y-YV8,R3-YS4,R3Y-YS4,R3S-YS4,R3-TS4,R3-

TS8,R3-RS4,R3-RS4A,R3S-RS4A,R3-RS8,R3Y-RS8,R3-

RS8A,R3-RS8B,R3-MS4,R3-MS8,R3Y-MS8,R3-DS4,R3-

DS4A,R3-DS8N,R3Y-DS8N,R3-LC2,R3-CT4,R3-

CT4A,R3-CT4B,R3-CT4C,R3-CT8A,R3-CT8B,R3-

CT8C,R3-CZ4,R3-PT4,R3-WT4,R3-WT4A,R3-WT4B,R3-

WT1,R3-WT1A,R3-WT1B,R3-WTU,R3-PA8,R3S-

PA8,R3-PA16,R3Y-PA16,R3-PA4,R3-PA4A,R3-PA4B,R3-

PA2,R3-PC16A,R3-AV4,R3-AV8,R3-AS4,R3-AS8,R3-

AT4,R3-AR4,R3-AD4,R3-DA16,R3Y-DA16,R3S-

DA16,R3-DA16A,R3Y-DA16A,R3-DA16B,R3-DA32A,R3-

DA64A,R3-DC16,R3Y-DC16,R3-DC16A,R3-DC16B,R3-

DC16C,R3-DC32A,R3-DC32C,R3-DC64A,R3-DC64C,R3-

DAC16,R3S-DAC16,R3-DAC16A,R3S-DAC16A,R3-

PD16,R3-PD16A,R3-PD16B,R3-PD16C,R3-RR8,R3S-

RR8,R3-BA32A,R3-BC32A,R3-PS1,R3-PS3,R3-

NC1,R3-NC2,R3-NC3,R3-ND1,R3-ND2,R3-ND3,R3-

NM1,R3-NE1,R3-NP1,R3-NF1,R3-NL1,R3-NL2,R3-

NFL1,R3-GM1,R3-GE1,R3-GD1,R3-GC1,R3-GFL1,R5-

BS,R5-EX1,R5-SV,R5T-SV,R5-SS,R5T-SS,R5-YV,R5T-

YV,R5-YS,R5T-YS,R5-TS,R5T-TS,R5-RS,R5T-RS,R5-

RSA,R5-MS,R5-DS,R5T-DS,R5T-CT,R5T-CTA,R5T-

CTB,R5T-PT,R5-PA2,R5T-PA2,R5-PC2,R5T-PC2,R5-

SV1A,R5-SS1A,R5-TS1A,R5-RS1A,R5-MS1A,R5-

DS1A,R5-DA4,R5T-DA4,R5-DA16,R5-DC4,R5T-

DC4,R5-DC16,R5-PS,R5-NC1,R5-NC2,R5-ND1,R5-

ND2,R5-NM1,R5-NP1,R5-NP2,R5-NE1,R5-NF1,R6D-

BS8A,R6D-BS8B,R6D-BS8P,R6D-PF1,R6D-SV2,R6D-

SS2,R6D-TS2,R6D-RS2,R6D-DS1,R6D-YV2,R6D-

YS2,R6D-DA4,R6D-DC4A,R6D-DC4B,R6-PSM,R6N-

BS8A,R6N-BS8B,R6N-BS8P,R6N-PF1,R6N-SV2,R6N-

SS2,R6N-TS2,R6N-RS2,R6N-DS1,R6N-YV2,R6N-

YS2,R6N-DA4,R6N-DC4A,R6N-DC4B,R6S-BS8A,R6S-

BS8B,R6S-BS8P,R6S-PF1,R6S-SV2,R6S-SS2,R6S-

TS2,R6S-RS2,R6S-DS1,R6S-YV2,R6S-YS2,R6S-

DA4,R6S-DC4A,R6S-DC4B,R6-NC1,R6-NC3,R6-

ND1,R6-NE1,R6-NE2,R6-NM1,R6-NM2,R6-NP1,R6-

NF1,R7M-DA16,R7M-DC16A,R7M-DC16B,R7M-

DC8C,R7M-SV4,R7M-TS4,R7M-RS4,R7M-MS4,R7M-

CT4E,R7M-YV2,R7M-YS2,R7M-EA8,R7M-EA16,R7M-

EC8A,R7M-EC16A,R7M-EC8B,R7M-EC16B,R7E-

DA16,R7E-DC16A,R7E-DC16B,R7E-SV4,R7E-TS4,R7E-

RS4,R7E-MS4,R7E-CT4E,R7E-YV2,R7E-YS2,R7E-

EA8,R7E-EA16,R7E-EC8A,R7E-EC16A,R7E-EC8B,R7E-

EC16B,R7D-DA16,R7D-DC16A,R7D-DC16B,R7D-

DC8C,R7D-SV4,R7D-TS4,R7D-RS4,R7D-MS4,R7D-

CT4E,R7D-YV2,R7D-YV2A,R7D-YS2,R7D-YS2A,R7D-

EA8,R7D-EA16,R7D-EC8A,R7D-EC16A,R7D-EC8B,R7D-

EC16B,R7C-DA16,R7C-DC16A,R7C-DC16B,R7C-

DC8C,R7C-DC8E,R7C-RR4,R7C-SV4,R7C-TS4,R7C-

RS4,R7C-RT4A,R7C-MS4,R7C-CT4E,R7C-YV2,R7C-

YS2,R7C-EA8,R7C-EA16,R7C-EC8A,R7C-EC16A,R7C-

EC8B ,R7C-EC16B ,R7C-EC8C,R7L-DA16 ,R7L-

DC16A,R7L-DC16B,R7L-DAC16,R7L-SV4,R7L-

TS4,R7L-RS4,R7L-YV2,R7L-YS2,R7L-RR8,R7L-

EA8 ,R7L -EA16 ,R7L -EC8A ,R7L -EC16A ,R7L -

EC8B,R7L-EC16B,R7ML-DA16,R7ML-DC16A,R7ML-

DC16B,R7ML-SV4,R7ML-TS4,R7ML-RS4,R7ML-

YV2,R7ML-YS2,R7ML-EA8,R7ML-EA16,R7ML-

EC8A,R7ML-EC16A,R7ML-EC8B,R7ML-EC16B,R7FN-

D A 1 6 , R 7 F N - D C 1 6 A , R 7 F N - D C 1 6 B , R 7 F N -

DAC16A,R7FN-DAC16B,R7FN-DC8C,R7FN-SV4,R7FN-

SVF4 ,R7FN-TS4 ,R7FN-RS4 ,R7FN-YV2 ,R7FN-

YS2,R7HL-DA16,R7HL-DC16A,R7HL-DC16B,R7HL-

DAC16A,R7HL-DAC16B,R7HL-DAC16ES,R7HL-

DC8C,R7HL-SV4,R7HL-SVF4,R7HL-TS4,R7HL-

RS4,R7HL-YV2,R7HL-YS2,R7G,R1M-GH,R1MS-

GH3,R1M-J3,R1M-A1,R1M-D1,R1M-P4,R1C-GH,R1D-

GH2,RZMS-U9

External Dimensions mm (inch)Series and Features Networks

1 2

T1T2T3T4 T5T6T7

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1819 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

105

(4.1

3)

175 (6.89) 40 (1.57)

Modbus

Compact, Multi-point Remote I/O

R1 SeriesR1

116 (4.57)

5 6 7 8

1 2 3 4

72 (2.83)

99 (

3.90

)

Ultra-Slim, Mixed Signal Remote I/O

R6 Series■ R6S

■ R7C

■ R3-BS08, R3-BSW08

■ R5-BS08, R5-BS09

R6

231 (9.09)

90 (

3.54

)

106.5 (4.19)

Compact, Mixed Signal Remote I/O

R5 SeriesR5

EthernetModbus

LONWORKS

FL-net

EthernetModbus

Multi-channel, Mixed Signal Remote I/O

R3 Series

130

(5.1

2)

224 (8.82)

1

2

3

4

5

6

1

2

3

4

5

6

1

2

3

4

5

6

519

20

21

22

15

16

17

18

23

24

25

26

27

28

6

7

8

9

10

11

12

13

14

1

2

3

4

1

2

3

4

5

6

7

8

9

10

111121314151617181920

2345678910

111121314151617181920

2345678910

120 (4.72)

R3

30 (1.18)

54 (2.13)

2 3 41 5

107 8 964 5 6 7

1 2 3

115 (4.53)

50 (

1.97

)

Expandable, Compact Remote I/O

R7 SeriesR7

LONWORKS

EthernetModbus

EthernetModbus

HLS is the abbreviation for “High-speed Link System” of Step Technica Co., Ltd.

◆ Only 78 mm (3.07 in) wide with the minimum system of 8 modules (for R6S / R6D)

◆ Selectable connection method – Tension-Clamp, Screw terminal or Euro terminal

◆ Analog I/O range selectable with the built-in DIP switches◆ Low power consumption

High-density remote I/O system using ultra-slim I/O modules.

◆ Palm-top size compact module can handle 4 analog input, 2 analog output or 8/16 discrete signals

◆ 8 or 16 discrete input/output module can be attached to the base module

◆ 1500 Vac isolation

Analog and discrete signals can be mixed by combining a discrete I/O module with an analog module.

◆ Wide selection of I/O modules including DC, AC, temperature, strain gauge, pulse trains, AC power, etc.

◆ Selections of AC power, CT and VT modules suitable for energy monitoring applications

◆ Dual redundant communication networks and power supplies

The removable terminal block is convenient for maintenance.

◆ Free combination of I/O modules, network modules and power modules

◆ Dual redundant communication networks and power supplies◆ 2 fully-isolated analog I/O per module◆ Re-transmitted output modules suitable for extra field monitoring

The slanted I/O terminals are easily accessible even with high-density wiring.

◆ Economical all-in-one module for Modbus, DeviceNet and CC-Link◆ 12-point universal input module◆ 8-point RTD/Pot input module◆ 4-point totalized counter input, 8 contact I/O module◆ 32-point discrete I/O modules◆ Trigger contact input and alarm contact output · Except for RZ series

P.432

P.433

P.434

P.434

P.432