002 HEATSINK ACCESS CEILING MIN. 225 [8.9] PANEL AIRSPACE OUTLET B 130 B...
Transcript of 002 HEATSINK ACCESS CEILING MIN. 225 [8.9] PANEL AIRSPACE OUTLET B 130 B...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
C
D
E
F
G
H
J
K
L
M
B
C
D
E
F
G
H
J
K
L
M
A
CRITICAL CHARACTERISTICSKEY CHARATERISTICSINSPECTIONMUST COMPLY TO ROHS DIRECTIVE 2011/65/EU
A_
29811.7[ ]
40415.9[ ]
105.0�$�
MIN. AIRSPACEOUTLET
225 8.9[ ]
161763.7[ ]
38115.0[ ]
1154.5[ ]
230.9[ ]
32512.8[ ]
30612.1[ ]
27610.9[ ]1807.1[ ]
1305.1[ ]
145257.2[ ]
55922.0[ ]
1305.1[ ]
783.1[ ]
2007.9[ ]
1234.8[ ]
783.1[ ]
2007.9[ ]
1234.8[ ]
161563.6[ ]
166365.5[ ]
251.0[ ]
150.6[ ]
4X 110.4[ ]
2007.9[ ]
240.9[ ]9
0.3[ ]200.8[ ]
110.4[ ]
144757.0[ ]
MIN AIRSPACEINLET
225 8.9[ ]
90935.8[ ]
1596.3[ ]
1817.1[ ]
63.53[ ]
632.5[ ]
100939.7[ ]
43317.0[ ]
2188.6[ ]
1 OF 5P454-1018
CONFIDENTIAL: PROPERTY OF DANFOSS A/S NORDBORG, DENMARK. NOT TO BE HANDED OVER TO BE COPIED OR BE USED BY A THIRD PARTY. TWO OR THREE DIMENSIONAL REPRODUCTION OF CONTENTS TO BE AUTHORIZED BY DANFOSS A/S.
SHEETMODEL002177R0491
REVDRAWING NUMBER
INSTALLATION DRAWING, D6H, IP21/54
CHECKED
04/05/12NDDESIGNED
08/24/16BCCHANGED
NOT VALID WITHOUT FROZEN DATE IN ID STAMP
DESCRIPTION
N/AFINISHA10.175
INTERPRET DIM. & TOL. PER ASME Y14.5M-1994ALL DIMENSIONS ARE IN MILLIMETERS
TOLERANCES UNLESS OTHERWISE SPECIFIED.X�#�1.0 .XX�#�0.50 �a��#�1.0
N/AMATERIALSIZESCALETHIRD ANGLE PROJECTION
USE M10 MTG BOLT OR 3/8" MTG BOLT
1. MAX AIRFLOW (BACKCHANNEL) - 7 M³ / MIN (250 CFM)2. MAX AIRFLOW (CABINET) - 1.7 M³ / MIN (60 CFM)3. MAX WEIGHT = 128 KG (283 LBS)4. CENTER OF GRAVITY: APPROXIMATE LOCATION ONLY, LOCATION MAY VARY BASED ON POWER RATING AND OPTIONS ORDERED.
HEATSINK ACCESSPANEL
SEE DETAIL A
SEE DETAIL B
CEILING
FLOOR
DETAIL ATOP MOUNTING HOLES
USE M10 MTG BOLT OR3/8" MTG BOLT
DETAIL BBOTTOM MOUNTING HOLES
002
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
C
D
E
F
G
H
J
K
L
M
B
C
D
E
F
G
H
J
K
L
M
A
963.8[ ]
00.0[ ]
1957.7[ ]
2278.9[ ]
GROUND 3X1686.6[ ]
45818.0[ ]
46 1.8
[]
00.0
[]
50 2.0
[]
99 3.9
[]
1475.8
[]
1827.2
[]
1937.6
[]
2218.7
[]2499.8
[]
26010.2
[]1465.8
[] 242
9.5[ ]
431.7[ ]
1214.8[ ]
2248.8[ ]
1114.4[ ]
321.3[ ]
160.6[ ]
130.5[ ]
251.0[ ]
130.5[ ]
130.5[ ]
321.3[ ]
160.6[ ]
130.5[ ]
285.6
11
[]
0.00
[]
2068.1
[]
00.0
[]
1134.4
[]
2 OF 5P454-1018SHEETMODEL
002177R0491REVDRAWING NUMBER
BRAKE / REGEN TERMINAL
MOTOR TERMINAL
CONTACTOR ONLY
NOTES: 1. PLACE CABLES THROUGH MARKED AREAS2. 95MM² (310 MCM) MAX WIRE SIZE
3X M10X20 STUDWITH NUT
R
S T UV
W
MAINS TERMINAL
SECTION B-BMOTOR TERMINALS
BRAKE / REGEN TERMINALS
MOTOR SIDECABLE ENTRY
MAINS SIDE CABLE ENTRY
BOTTOM VIEW
M10
MOTOR TERMINAL
M10
BRAKE / REGEN TERMINAL
M10 NUT AND BOLT
MAINS TERMINAL
SECTION A-AMAINS TERMINALS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
C
D
E
F
G
H
J
K
L
M
B
C
D
E
F
G
H
J
K
L
M
A
00.0
[]
99 3.9
[]
1536.0
[]
2258.9[ ]
00.0[ ]
30311.9[ ]
00.0[ ]
45 1.8
[]
251.0[ ]
120.5[ ]
150.6[ ]
2118.3
[]
00.0
[]
28611.2
[]
00.0
[]
3 OF 5P454-1018SHEETMODEL
002177R0491REVDRAWING NUMBER
MAINS TERMINAL
CONTACTOR AND DISCONNECT
NOTES: 1.REFER TO SHEET 2 FOR BRAKE AND MOTOR TERMINAL DETAILS
R S T
SECTION A-AMAINS TERMINALS
MAINS TERMINAL
M10 NUT ANDBOLT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
C
D
E
F
G
H
J
K
L
M
B
C
D
E
F
G
H
J
K
L
M
A
56522.2[ ]
00.0[ ]
00.0[ ]
00.0
[]
00.0
[]
52 2.1
[]
99 3.9
[]
1455.7
[]
1696.7
[]
42616.8[ ]
31.81[ ]
15.01[ ]
15.91[ ]
78 3.1
[]
00.0
[]
4 OF 5P454-1018SHEETMODEL
002177R0491REVDRAWING NUMBER
MAINS TERMINAL
CIRCUIT BREAKER
R S T
NOTES: 1.REFER SHEET 2 FOR BRAKE AND MOTOR TERMINAL DETAILS
SECTION A-AMAINS TERMINALS
MAINS TERMINALSCALE 1.500
M10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
C
D
E
F
G
H
J
K
L
M
B
C
D
E
F
G
H
J
K
L
M
A
690V D6H D6H D6H
525V D6H D6H D6H D6H
500V D6H D6H D6H
400V D6H D6H D6H
KW NORMAL OVERLOAD
90 110 132 160 200
KW HIGH OVERLOAD
75 90 110 132 160
KW RATED DRIVES
575V D6H D6H D6H
460V D6H D6H D6H
HP NORMAL OVERLOAD
125 150 200 250
HP HIGH OVERLOAD
100 125 150 200
HORSEPOWER RATED DRIVES
PLATFORM VOLTAGE MODEL/TYPECODE FRAME(IP21/IP54)
HVAC
T4
FC-102N110T4
D6H
FC-102N132T4
FC-102N160T4
T7
FC-102N110T7
FC-102N132T7
FC-102N160T7
AQUA
T4
FC-202N110T4
FC-202N132T4
FC-202N160T4
T7
FC-202N110T7
FC-202N132T7
FC-202N160T7
AUTOMATION
T5
FC-302N90KT5
FC-302N110T5
FC-302N132T5
T7
FC-302N90KT7
FC-302N110T7
FC-302N132T7
5 OF 5P454-1018SHEETMODEL
002177R0491REVDRAWING NUMBER
THE TABLES BELOW ARE USED TO DETERMINE THE FRAME SIZE FOR A GIVEN POWER AND VOLTAGE RATING, WITH A CIRCUIT BREAKER, CONTACTOR OR CONTACTOR+DISCONNECT.1) IDENTIFY THE POWER IN NORMAL OVERLOAD (N.O.) OR HIGH OVERLOAD (H.O.), KILOWATTS (KW) OR HORSEPOWER (HP). 2) READ DOWN THE COLUMN TO THE ROW WITH THE CORRECT VOLTAGE TO IDENTIFY THE FRAME SIZE.THIS DRAWING IS FOR D6H FRAMES,
THE TABLE BELOW CAN BE USED TO DETERMINE THE FRAME SIZE IF THE SPECIFIC MODEL/TYPE CODE WITH A CIRCUIT BREAKER, CONTACTOR OR CONTACTOR+DISCONNECT.