There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

17

Transcript of There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

Page 1: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.
Page 2: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

There are three stages for house wiring:›Underground stage›Rough stage›Electrical stage

Page 3: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

•From the power company, we get:•two hot wires•one neutral wire.

•The two major voltages available in our homes are:

•115 VAC

•230 VAC

•Most of the receptacles in our homes are 115 VAC.•Washer, Dryer, Oven, etc. use the 230 VAC receptacle.

Page 4: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

VOLTAGE RECEPTACLES

115 VAC 230 VAC

Neutral Hot

Ground Hot wires

Ground wire

Page 5: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

115 VAC 230 VAC

Wires:◦ Hot (red/black wire)◦ Neutral (white wire)◦ Ground (bare copper

wire)

Screws:◦ Brass (for hot wire)◦ Silver (for neutral wire)◦ Green with green dot

(ground wire)

Wires:◦ Hot (red wire)◦ Hot (black wire)◦ Ground (bare copper

wire) Screws:

◦ Brass (for hot wire)◦ Brass (for hot wire)◦ Green with green dot

(ground wire)

Page 6: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

HOUSEHOLD WIRING FOR ROOMS:

For rooms:Within the first 6ft of an entrance into a room, there should be an 120volt receptacle outlet and then for every other 12ft there should be an outlet.

For the kitchen:The outlets should be a minimum of 2ft apart.

Receptacle connection: On the side of ground the 2 neutral wires are stripped ½

inch and pushed in the hole. Make sure to pull on it to check that it does not come out. Now strip the black wires ¼ inch, push them into the hole opposite of ground.

14 W gauge for bedrooms, hallways, living rooms, and all ceilings.

Page 7: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

Duplex Receptacles: Some duplexes have 5 wires going into the receptacle, while

others have 3 wires going into the receptacle. If a circuit is a feeder to the other circuits, then it has 5 wires: 2

neutral (white), 2 hot (black/red), 1 ground (bare copper wire). The 5 wires you see are actually power coming in and coming out.

If it is the end of a circuit, then it has 3 wires: 1 neutral (white), 1 hot (black/red), 1 ground (bare copper wire)

Every receptacle holds 15 Amperes of Current. Kitchen appliances have 20 Amperes of Current and Dryers have 30 Amperes of Current.

Every wire has an adjacent screw

Page 8: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

-GFCI: Stands for Ground Fault Circuit Interrupt. This receptacles is different from conventional receptacles. In the event of a ground fault, a GFCI will trip and quickly stop the flow of electricity to prevent serious injury.-For kitchens and bathrooms with sinks, GFI protection receptacles are required for anything between 6ft from water. Make sure everything is grounded for safety purposes.-When does a ground fault occur? It occurs when electricity passes through a persons body to reach the ground instead of following its normal path.-GFCI receptacles protect against circuit overloads, short circuits, or shocks. -For GFCI’s, a 12 W gauge is required which is thicker than the 14 W gauge.

GFCI

Page 9: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

GFCI CONTINUED… The GFCI receptacle itself has the Test and

Reset buttons. The reciprocal feeling into the GFCI main no reciprocal has no Reset/Test buttons, but will indicate GFCI stickers on them.

not GFCI GFCI

Page 10: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

• A single pole (one location) or a 3 way (multiple locations) can be put only on the incandescent.•You will see 4 colored wires on the dimmer. Blue, yellow, black and green.

Connecting wires for dimmer:• Green dimmer Ground leads to Green or

copper wire in wall box.•Black dimmer lead to Line (hot) wall box

wire removed from old switch. •Blue Dimmer lead to remaining wall box wire

(Load)•Cap Yellow dimmer lead with appropriate

size wire nut.

Page 11: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

•REGULAR MEDIUM BASE: used in regular fixtures

•MOGUL BASE: is thicker and is used for street lights

•CANDELABRA BASE: is smaller and is used in paddle/ceiling fan fixtures

*On a ceiling fan which has lights, always use a A15 lamp because the filament is thicker and it will last

longer even though the fan causes vibration**G-style lamps are used in bathrooms*

*Fluorescent lamps are used under cabinets and countertops, and are available only up to a wattage of

32 Watts instead of 40 Watts*

Page 12: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

Gang Box •The Gang Box must be UL listed in approval for electrical work. Deep Gang Boxes are maximum of 22.5cubic inches. •Inside the house : All gang boxes must be UL approved.•Outside the house the gangs used must be UL approved and suitable for dampness/wet conditions. •According to Title 24 everything in the home i.e. Bathroom, Kitchen, underneath the cabinets, laundry room, outside light should have incandescent lights.

Page 13: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

Low Voltage Wires

Red……Computer-CAT5

White….RG6-TV, SAT, DSL, Cameras

Black…..RG6-””

Blue……Phone-CAT5

You can use red alone but to differentiate between computer wires and phone wires you use different colors.

Page 14: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

High Voltage Wires

14/ 2- 15A :is a 14G wire black, white, and ground used for lighting wiring bedroom plug switches. anything rated up to 15A.

12/ 2- 20A :is a 12G wire, black, white, ground, yellow wire for identification.

12/ 3- 20A :is a 12G wire black (hot) white (neutral), red (hot), and ground. In this there are

2 hot wires in one wire. If you have two circuits in the same area then you could use black for one circuit & jump the other circuits through red wires especially in General appliances.

Page 15: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

High Voltage wires Continued 10 Gauge/30 A: is Orange in color used

for Dryers or Ovens if under 30 A. it is also used for Air conditioning if no more than 30A is required

8 Gauge/40/50 A: is a Black wire and is used in ovens that are over 30 A.

6 Gauge/50/60 A: is used only in Air Conditioners and Ovens that have very high amperage

Page 16: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

Low voltage enclosure: TV, Telephone, computers, cameras, speaker DVR, i.e. communication, run one main limit is 2RG6 (TV coax) cat 5- phone line or computer line. When it says TV run 1RG6 i.e. Black wire.

……………..Phone

P…………………PlugTV……………….TVOn/Q…………….All 4 wires drop (2cat5 and 2RG6)

High Voltage……Stapled every 4ft 6in Low Voltage…….Not stapled tightly 1RG6……………TV Only 2RG6……………TV & DVR & HD

Page 17: There are three stages for house wiring: › Underground stage › Rough stage › Electrical stage.

RG6-Quad shield: a type of wire that helps to give a better signal, but not a better picture.

(You could run High Definition signals like Comcast Internet Company with RG6)

The wires going into every gang box should be stapled within 6 inches of the box, on the wood.

The wires going into Double or Triple boxes, should be 12 inches away from the box on the wood.

Rough Stage Continued…Rough Stage Continued…