> Port size: 1/4” or 3/8” (ISO G/PTF) > Excelon design...

4
F72G-˙˙˙-˙˙˙ F72G - EXCELON® Modular System General purpose filter 12/16 en 8.160.100.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8028g) © 2015 Norgren Inc. > Port size: 1/4” or 3/8” (ISO G/PTF) > Excelon design allows in-line installation or modular installation with other Excelon products > Quick release bayonet bowl Technical features Technical data - standard models Symbol Port size Size Drain Filter element (µm) Bowl Weight (kg) Model (lbs) G1/4 Basic Manual 40 PC (transparent) 0,49 1.0 F72G-2GN-QT3 G3/8 Manual 40 PC (transparent) 0,49 1.0 F72G-3GN-QT3 G1/4 Basic Manual 5 PC (transparent) 0,49 1.0 F72G-2GN-QT1 G3/8 Manual 5 PC (transparent) 0,49 1.0 F72G-3GN-QT1 G1/4 Basic Automatic 40 PC (transparent) 0,49 1.0 F72G-2GN-AL3 G3/8 Automatic 40 PC (transparent) 0,49 1.0 F72G-3GN-AL3 G1/4 Basic Automatic 5 PC (transparent) 0,49 1.0 F72G-2GN-AL1 G3/8 Automatic 5 PC (transparent) 0,49 1.0 F72G-3GN-AL1 Option selector Port size Substitute 1/4” 2 3/8” 3 Thread form Substitute PTF A ISO G parallel G Service life indicator Substitute Without (Standard) N With D Drain Substitute Manual Q Semi automatic S Automatic A *1) *1) Supplied with long bowl option only Filter element Substitute 5 μm (Standard) 1 40 μm (Standard) 3 Bowl *1) Substitute Metal with liquid level indicator D Metal (long) with liquid level indicator E Transparent T Transparent (long) L Transparent with guard (long) W Medium: Compressed air only Maximum operating pressure: Transparent bowls: 10 bar (150 psi) Metal bowls: 17 bar (250 psi) Metal bowls with automatic drain: 10 bar (150 psi) Filter element: 40 or 5 μm Port size: G1/4, G3/8, 1/4” or 3/8” PTF Flow: 28 dm 3 /s at port size: G1/4 Operating pressure: 6,3 bar (91 psi) Δp: 0,5 bar (7.2 psi) Filter element: 40 µm Drain: Manual, automatic or semi automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 0,35 bar (5 psi) Bowl pressure required to open drain: ≤ 0,2 bar (3 psi) Minimum air flow required to close drain: 0,1 dm 3 /s (0.2 scfm) Manual operation: depress pin inside drain outlet to drain bowl Semi automatic drain operating conditions (pressure operated): Bowl pressure required to close drain: Greater than 0,1 bar (1.5 psi) Bowl pressure required to open drain: Less than 0,1 bar (1.5 psig) Minimum air flow required to close drain: 0,5 dm 3 /s (1 scfm) Service life indicator: Available on request Ambient/Media temperature: Transparent bowl: -34 ... +50°C (-30 ... +125°F) Metal bowl: -34 ... +65°C (-30 ... +150°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Body: die cast zinc Bowl: transparent PC or die cast zinc or transparent with zinc bowl guard Liquid level indicator lens (metal bowl): transparent PA Filter element: sintered PP Elastomers: CR & NBR

Transcript of > Port size: 1/4” or 3/8” (ISO G/PTF) > Excelon design...

Page 1: > Port size: 1/4” or 3/8” (ISO G/PTF) > Excelon design ...cdn.norgren.com/pdf/en_8_160_100_F72G.pdf · General purpose filter 12/16 en 8.160.100.03 Drawings Dimensions in mm Projection/First

F72G-˙˙˙-˙˙˙

F72G - EXCELON® Modular System General purpose filter

12/16en 8.160.100.01

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8028g) © 2015 Norgren Inc.

> Port size: 1/4” or 3/8” (ISO G/PTF)

> Excelon design allows in-line installation or modular installation with other Excelon products

> Quick release bayonet bowl

Technical features

Technical data - standard modelsSymbol Port size Size Drain Filter element

(µm)Bowl Weight

(kg)Model

(lbs)G1/4 Basic Manual 40 PC (transparent) 0,49 1.0 F72G-2GN-QT3

G3/8 — Manual 40 PC (transparent) 0,49 1.0 F72G-3GN-QT3

G1/4 Basic Manual 5 PC (transparent) 0,49 1.0 F72G-2GN-QT1

G3/8 — Manual 5 PC (transparent) 0,49 1.0 F72G-3GN-QT1

G1/4 Basic Automatic 40 PC (transparent) 0,49 1.0 F72G-2GN-AL3

G3/8 — Automatic 40 PC (transparent) 0,49 1.0 F72G-3GN-AL3

G1/4 Basic Automatic 5 PC (transparent) 0,49 1.0 F72G-2GN-AL1

G3/8 — Automatic 5 PC (transparent) 0,49 1.0 F72G-3GN-AL1

Option selectorPort size Substitute

1/4” 2

3/8” 3

Thread form Substitute

PTF A

ISO G parallel G

Service life indicator

Substitute

Without (Standard) N

With D

Drain Substitute

Manual Q

Semi automatic S

Automatic A *1)

*1) Supplied with long bowl option only

Filter element Substitute

5 μm (Standard) 1

40 μm (Standard) 3

Bowl *1) Substitute

Metal with liquid level indicator D

Metal (long) with liquid level indicator

E

Transparent T

Transparent (long) L

Transparent with guard (long) W

Medium:Compressed air onlyMaximum operating pressure:Transparent bowls: 10 bar (150 psi) Metal bowls: 17 bar (250 psi) Metal bowls with automatic drain: 10 bar (150 psi)Filter element:40 or 5 μmPort size:G1/4, G3/8, 1/4” or 3/8” PTFFlow:28 dm3/s at port size: G1/4 Operating pressure: 6,3 bar (91 psi) Δp: 0,5 bar (7.2 psi) Filter element: 40 µmDrain:Manual, automatic or semi automatic

Automatic drain operatingconditions (float operated):Bowl pressure required toclose drain: > 0,35 bar (5 psi)Bowl pressure required toopen drain: ≤ 0,2 bar (3 psi)Minimum air flow required toclose drain: 0,1 dm3/s (0.2 scfm)Manual operation: depress pininside drain outlet to drain bowlSemi automatic drain operating conditions (pressure operated):Bowl pressure required to close drain: Greater than 0,1 bar (1.5 psi)Bowl pressure required to open drain: Less than 0,1 bar (1.5 psig)Minimum air flow required to close drain: 0,5 dm3/s (1 scfm)

Service life indicator:Available on requestAmbient/Media temperature:Transparent bowl:-34 ... +50°C (-30 ... +125°F) Metal bowl: -34 ... +65°C (-30 ... +150°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).

Materials:Body: die cast zinc Bowl: transparent PC or die cast zinc or transparent with zinc bowl guardLiquid level indicator lens (metal bowl): transparent PAFilter element: sintered PPElastomers: CR & NBR

Page 2: > Port size: 1/4” or 3/8” (ISO G/PTF) > Excelon design ...cdn.norgren.com/pdf/en_8_160_100_F72G.pdf · General purpose filter 12/16 en 8.160.100.03 Drawings Dimensions in mm Projection/First

00 10 20 30 40 50

0,2

0,4

0,6

0,8

10,04,0 8,02,5 6,3

∆ p (bar)

Qn (dm3/s)0

0 10 20 30 40 50

0,2

0,4

0,6

0,8

10,04,0 8,02,5 6,3

∆ p (bar)

Qn (dm3/s)

F72G - EXCELON® Modular System General purpose filter

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8028g) © 2015 Norgren Inc.en 8.160.100.02

12/16

Flow characteristics

Pre

ssur

e d

rop

Δp

Pre

ssur

e d

rop

Δp

Element 40 μmPort size G1/4

Element 5 μmPort size G1/4

Air flow Air flow

Inlet pressure bar (psi) Inlet pressure bar (psi)

Accessories

Service kitsPorting block for pressure switch

Pressure switch(0,5 ... 8 bar)

0523109000000000 0881300000000000

Padlock (brass) with two keys *1)

0613633000000000

*1) for shut-off valves

Pressure switch PadlockManual drain Automatic drain Replacement

element

F72G-KITM40 (40 µm) F72G-KITA40 (40 µm) 5925-02 (40 µm)

F72G-KITM05 (5 µm) F72G-KITA05 (5 µm) 5925-03 (5 µm)

Wall mounting bracket

Page 3

Quikclamp®

Page 3

Quikclamp with wall bracket®

Page 3

Quikmount pipe adaptor *1)

Page 3

Porting block with three alternative 1/4” ports

Page 3

2/2 Shut-off valves (for full technical specification see datasheet 8.160.600)

Page 3

3/2 Shut-off valves (for full technical specification see datasheet 8.160.600)

Page 3

4224-50 4214-51 4214-52 G1/4: 4215-08 G1/4: 4216-52 G1/4: T72B-2GA-P1N G1/4: T72T-2GA-P1N

G3/8: 4215-09 1/4 PTF: 4216-50 G3/8: T72B-3GA-P1N G3/8: T72T-3GA-P1N

1/4 PTF: 4215-02 1/4 PTF: T72B-2AA-P1N 1/4 PTF: T72T-2AA-P1N

3/8 PTF: 4215-03 3/8 PTF: T72B-3AA-P1N 3/8 PTF: T72T-3AA-P1N

*1) Please use a Quikmount pipe adaptor if the Quikclamp be mounted at inlet or outlet side.

Page 3: > Port size: 1/4” or 3/8” (ISO G/PTF) > Excelon design ...cdn.norgren.com/pdf/en_8_160_100_F72G.pdf · General purpose filter 12/16 en 8.160.100.03 Drawings Dimensions in mm Projection/First

134

185

#

19

53

176

214

#

ø 9,5

3

2

4

141

192

#

R1/8

50,5

42

48,5

1 1

R1/8

134

185

#

19

53

176

214

#

ø 9,5

3

2

4

141

192

#

R1/8

50,5

42

48,5

1 1

R1/8

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8028g) © 2015 Norgren Inc.

F72G - EXCELON® Modular System General purpose filter

en 8.160.100.0312/16

Drawings Dimensions in mm Projection/First angle

# Minimum clearance required to remove bowl1 Main ports 1/4” or 3/8” 2 Service life indicator optional 3 Transparent bowl 4 Metal bowl with liquid level indicator lens

Manual drain

Semi-automatic drain

Automatic drain

Page 4: > Port size: 1/4” or 3/8” (ISO G/PTF) > Excelon design ...cdn.norgren.com/pdf/en_8_160_100_F72G.pdf · General purpose filter 12/16 en 8.160.100.03 Drawings Dimensions in mm Projection/First

40

57

G1/2

40

3

44

32

+-

14

13

3

14

36,5

36,5

90°

74 59

14

38

4,5

56

ø 5

,3

3 36,5

36

36

3

28,5

2010

29

29

16A

1

46

18,5

8

35

38

60

8

39 51

7

42

1,51

48,5

50,5

42

67

25

16

1421

11

1

1

F72G - EXCELON® Modular System General purpose filter

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8028g) © 2015 Norgren Inc.en 8.160.100.04

12/16

Warning

These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren Inc.

Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.

EN - Englisch

AccessoriesQuikclamp®

Porting block

Quikclamp® with wall bracket

Pipe adapter Wall mounting bracket

Shut-off valves Porting block for pressure switch

10 Ports 1/4” (ISO G/PTF) plugged 1 Main ports 3/8”, 1/2” or 3/4” (ISO G/PTF)

1 Main ports

1 Main ports 1/4” or 3/8” (ISO G/PTF)

11 Exhaust port M5 at 3/2 valve only

13 Pressure switch is not in scope of delivery 14 Alternative G1/4 ports plugged