Business Strategy of Hyundai with respect to a Fuel Cell car in ...
Главная страница сайта ООО ... - HYUNDAI...
Transcript of Главная страница сайта ООО ... - HYUNDAI...
HYUNDAIINVERTER
Medium Voltage
Hyundai MV inverters feature intelligent vector controls that allowmotors to operate more efficiently and offer customer a full rangefrom 155kW to 6,400kW.
High performance and efficiency
Clean power for motors
Small footprint and economical maintenance
Global standard CE
Model Name Indication >
HYUNDAIMV INVERTER
Series Name Applicable Motor Output (kW) Voltage ClassL: 3300V
M: 4160V
H: 6600V
N5000 3930 H 5Frequency
5: 50Hz
6: 60Hz
www.hyundai-elec.com
Clean PowerHyundai Inverter
www.hyundai-elec.com
C o n t e n t s 04 09 10 11 12 13
Featu
res
Certif
icat
ion
Circuit
Config
uratio
n
Connec
tion
Specific
atio
ns
Outlin
e and
Dim
ensio
ns
High Performance and Efficiency
■ Power Factor: over 0.95No requirements for power factor correction capacitor
■ System Efficiency: over 97%System efficiency is improved by connecting the power
and motor without input-output filter and output
transformer
Clean Power Input
■ A clean input wave is achieved via a secondary
phase-shifted transformer
■Without a filter, N5000 meets the stringent harmonic
requirements of IEEE-519 (1992)
■ Protects the other equipment from harmonic disturbance
Outstanding Operation Features by the Improved Sensorless Vector Control
■ Energy saving V/F control for the fluid load (Fan, Pump)
■ Inherent speed sensorless vector control of N5000
- High starting torque operation
- Control of current, speed and vibration of motor at the low speed
range of light duty
- Quick torque responsiveness and improved speed precision
- Strong control regardless of motor specifications
Supplies of Clean Power for Motors
■Output waveforms, without a filter, are close to sine waves due to
multiple PWM control
- No cable length & motor type restrictions
- Existing motor can be used without modifications
- Reduced noise and vibration of motors
- 3.3kV - 13 level/4.16kV -17 level/6.6kV - 25 level output
(Based on line to line voltage)
Small Footprint and Economical Maintenance
■ Small footprint and reduced installation costs due to no
requirements for ancillary equipments such as input & output filter
and the integral structure incorporating the input transformer and
inverter panel
■ Thanks to the modulized single-phase inverter of draw-out type, easy
maintenance and time saving are achieved.
※Much more improved vector control functions can be achieved
if the encoder is installed (Option).
>> Features
40 50 60 70 80 90 100
100
90
80
70
60
50
40
30
Po
we
r F
act
or/
Eff
icie
ncy
(%
)
Speed (%)
Clean Power Inverter Power Factor
Clean Power Inverter Efficiency
Conventional SCR DRIVE
Input current
Input voltage
Reading Floppy Disk Drive
5 ms
3.00 kV
5 ms
3.00 kV
5 output tooutput to
HARDCOPYHARDCOPY
Int. PrinterFlpyGPIBRS232Centronics
Int. PrinterFlpyGPIBRS232Centronics
backgroundbackground
BlackWhiteBlackWhite
protocolprotocol
HP 7550TIFF b/wTIFF colorBMP colorBMP compr
HP 7550TIFF b/wTIFF colorBMP colorBMP compr
page Feedpage Feed
OFF ONOFF ON
33
5 ms BWL5 ms BWL
DC 94 mVDC 94 mV ± 200 mV± 200 mV
6.6kV output voltage6.6kV output voltage
20 kS/s20 kS/s
STOPPEDSTOPPED11
1234
1234
.1
.130050
.1
.130050
VVmVmV
VVmVmV
DCDC50ΩDC
DCDC50ΩDC
10K
100
10K
100
X
X
[ Conventional System ]
[ Clean Power System ]
InputFilter
OutputFilter
InputTR Inverter
InputFilter
OutputFilter
InputTR Inverter
1 s1 s
Ext AC -5 mV 1MΩExt AC -5 mV 1MΩ
25 kS/s25 kS/s
STOPPEDSTOPPED
1234
1234
24.00.2.5
24.00.2.5
VVVV
VVVV
DCDCDCDC
DCDCDCDC
1K
100
1K
100
X
X
44
33
22
1 1
1
1 s
4.00 V
1 s
4.00 V
22
1 s
200 V
1 s
200 V
33
1 s
50 A
1 s
50 A
44
3-Apr-08
16:10:30
3-Apr-08
16:10:30
1 s
2.00 V
1 s
2.00 VSpeed
Torque
Voltage
Current
04 HYUNDAI INVERTER
HYUNDAI INVERTER 05
Multi-Winding Phase-Shifted Transformer
- Power supply lead-in terminal and output terminal section to the cell inverter
- 3.3kV: 9 phase shift windings
- 4.16kV: 12 phase shift windings
- 6.6kV: 18 phase shift windings
- Free standing panel type
Cell Inverter
- 3, 4 or 6 cells connected in series per inverter output phase
- Modulization of PWM controller and power conversion section
- 13 level (3.3kV)/17 level [4.16kV]/25 level (6.6kV) 3 phase direct output
Control Panel
- Process controller for high speed calculating digital signal process
- Self-Diagnostic
- Extendable I/O board
- CAN communication control and optical signal transmission
- UPS for back-up of control power (Option)
Multi-Winding Phase-Shifted Transformer Cell Inverter Control
Panel
>> Features
06 HYUNDAI INVERTER
Functions for Trip-Free Operation (Option)
W-U Voltage
= 6600V
W-U Voltage
= 6200V
U-V Voltage
= 6600V
U-V Voltage
= 6200V
V-W Voltage
= 6600V
V-W Voltage
= 6200V
U
VW
U
VW
Cell Bypass Operation(with cell U3 out of service)
Normal Operation
Redundant Inverter Controller
If the master controller is out of service during operation, output is generated due to automatic switching to the slave controller
Redundant Control Power
The redundant control power module is equipped with AC
440V and DC 120V and monitors the control power. In case
of the failure of a control power module, an automatic
switching to the reserve module is realized
Redundant Fiber-Optic Cable for CAN Communication
If there are problems with the optic cable during operation, an automatic switching to the standby reserve optical
communication H/W is made (It needs a redundant controller as option)
MASTER
M_
OP
TIC
S_
OP
TIC
AIO
SLAVE DIO
Improved Cell Bypass
In case of cell failure during operation, the faulty cell will be bypassed and the neutral point will be shifted (balance is
restored through angle adjustment). 92% of the rated voltage can be output after the failure of one cell.
HYUNDAI INVERTER 07
Unbalance Control of Phase Angle
Balance can be restored by neutral point shift adjusting phase angles
Equivalent Circuit with 6 Cells Out of Service
Comparison of Output's Characteristic after Unbalance Control
Vector Diagram
Fail
Fail
Fail
Fail
Motor
Fail
바이패스 Circuit
Fail
AA
B
C
Vab
Vab
Vca
A6635V
A6635V
A5635V
A4635V
A3635V
A2635V
A1635VC1
635VB1
635VB2
635VB4
635VB5
635VB6
635V
A5635V
A4635V
A3635V
A2635V
A1635V
C1635V
B1635V
B2635V
B4635V
B5635V
B6635V
Vca
Vbc
120̊
228.9˚
69.2˚61.9˚
120̊
120̊
Vbc
C
B
Before Unbalance Control After Unbalance Control
3 Phase Output Current
Unbalance after Loss of 6 Cells Balance Restored by Neutral Point Shift
>> Features
08 HYUNDAI INVERTER
Inverter Operator with User-friendly Design (10.2inch Color LCD)
- Multi language support (Option)
Easy Touch Key Settings Inverter Fault Display
■ Fault type ■Operating frequency at time of fault
■ Time of Fault ■ Voltage and current at time of fault
Inverter Operation Status Display
■Operation frequency, input-output voltage, output current
■ Input-output of external signals
■MV switchgear on/off status
■Output voltage wave form
>>Certification
HYUNDAI INVERTER 09
Optional User Friendly PC-based Console (Option)
CE (Conformity European)
■Remote operation and monitoring via laptop or desktop
■ Easy parameter setting and monitoring
■ Various communication interfaces (RS-232, RS-485, MODBUS)
■Custom-made MMI display and upgrade support
■Display of Detailed Information
>>Circuit Configuration
10 HYUNDAI INVERTER
3.3kV System Circuit Configuration 6.6kV System Circuit Configuration
PowerCellU1
PowerCellV1
PowerCellW1
PowerCellU2
PowerCellV2
PowerCellW2
PowerCellU3
PowerCellV3
PowerCellW3
3,300VACInduction
Motor
6,600VACInduction
Motor
PowerCellU1 Power
CellV1 Power
CellW1
PowerCellW2
PowerCellW3
PowerCellW4
PowerCellW5
PowerCellW6
PowerCellV2
PowerCellV3
PowerCellV4
PowerCellV5
PowerCellV6
PowerCellU2
PowerCellU3
PowerCellU4
PowerCellU5
PowerCellU6
U U
W V W V
635V
635V
635V
635V
635V
635V
635V
Cell Voltage=635V
Phase Voltage
Vu=1,905V
Interline Voltage
Vuv=3,300V
Cell Voltage=635V
Phase Voltage
Vu=3,810V
Interline Voltage
Vuv=6,600V
Single-phase Cell Inverter (Power Cell)
>>Connection
HYUNDAI INVERTER 11
Motor
9/12 /18 cell inverter
Input Voltage Output VoltageOutput Current
Isol
atio
nTr
ansf
orm
er URMain Power
AC 3-Phase
3300V or 6600V
50/60 Hz
Control Power
AC400V Class
AC200V Class
50/60Hz
DC110V (Option)
Start/Stop Inverter Ready
Inverter Run
Inverter Fault
Inverter Alarm Digital
8ch
Output
Analog
4ch
Output
Digital
16ch
Input
Analog
4ch
Input
DifferentialPG
Encorder Input
Output
Signal
5 or 15V
123456
PG
Emergency Stop
Trip Reset
Input VCB Close
Output VC Close
External Fault
Speed Reference
4-20mA DC
or 0-10V DC
X11 X12
X13X13
X41
1(+)
(-)
(+)
(-)
(+)
(-)
(+)
(-)
(+)
(-)
(+)
(-)
(+)
(-)
(+)
(-)
2
3Spare
4
5
6
7
8
S
T
R1
S1
T1
P
N
V
W
DIO
AIO
COM2
COM3
OperatorRS485
M
Notebook PC
N5000 Multi-level Inverter
Spare
Spare
1
2
34
5
6
7
8
9
10
12
32
11
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
11
12
13
14
15
16
17
18
Output Frequency
4-20mA DC / 0-10V DC
Output Current
4-20mA DC / 0-10V DC
Spare
3 Class Ground
1 Class Ground
More Than 100SQ
G1
G2
Control
Ground
Power
Ground
Output Power
4-20mA DC / 0-10V DC
※ Control Power Capacity 1. 3.3kV-2250kVA (5kVA)
2. 3.3kV-4000kVA (15kVA)
3. 6.6kV-4500kVA (5kVA)
4. 6.6kV-6000kVA (20kVA)
5. 6.6kV-8000kVA (25kVA)
>> Specifications
12 HYUNDAI INVERTER
0-120Hz
120%, 60 sec
3-phase 3300V, 50/60Hz, 3-phase 4160V, 50/60Hz, or 3-phase 6600V, 50/60Hz
3-phase 200V or 400V, 50Hz or 60Hz
Voltage: ±10% , Frequency: ±5%
Approx 95% or more at normal operating speed
Approx 97% (Including transformer)
Sensorless vector control + Multi-level sinusoidal PWM (Pulse Width Modulation)
±0.5% of maximum output frequency (Analog input)
Square torque load, Constant torque load
0.1-3600 sec (depend on GD2 of load machine)
Soft stall (Automatic load reduction control during overload), Ride-through function (0-83ms,
non-torque control), specific frequency evasion function, total run time display function,
non-stop operation during speed reference loss, multiple Acc./Dcc. rate setting, flying start
Current limit, overcurrent, overvoltage, overload, undervoltage, ground fault, CPU error,
cooling fan abnormal, control power abnomal
2ea among RS485/232/modbus (standard), ethernet, profibus-DP (Option)
Color LCD graphic display: Color TFT touch method 10.2 inch LCD
Start, stop, reset fault, interlock (Emergency stop)
Input: 4 channel (DC 0-10V or DC 4-20mA) Output: 4 channel (DC 0-10V or DC 4-20mA)
Input: 16 channel (Dry contact)
Output: 8 channel (Dry contact: AC 250V 5A or DC 30V 5A)
If an inverter cell functions abnormally, continuous operation is possible via reduced power output
When main control device is abnormal, auxiliary control device is communicated with optical siginal
transmitter
In case of power failure AC and DC can be received together for control input power
Temperature class H, dry type, tapping range ±5% for N5000
IP20 (IEC-529), IP42 (Option)
Free standing, front maintenance type, door handle key attached
Air cooled by ventilation fans mounted on panels
Munsell No. 5Y 7/1
0-40 C̊
Max 90% (No condensation)
Max 75dB (A)
1000m above sea level or less
0.5G or less at 10-50Hz
Indoors
Fan, blower, pump, compressor, extruder, mixer etc.
Electrical performance: IEC Components and others: KS
※ 1) As for the non-standard voltage (3.0/6.0/6.3/11/13.8kV) motor or over 8MVA inverter, please contact Hyundai Heavy Industries Co., Ltd.
2) Based on standard squirrel type 4 pole motors.
200
35
155
300
53
245
400
70
325
500
88
410
600
105
490
750
132
620
1000
175
835
1250
219
1040
1500
263
1270
1750
307
1500
2000
350
1710
2250
394
1940
2700
473
2250
3000
525
2500
3500
619
2800
4000
707
3200
3300V 1)
4160V 1)
6600V 1)
Voltage class
3.3kV output capacity (kVA)
Rated output current (A)
Motor power output (kW) 2)
Voltage class
4.16kV output capacity (kVA)
Rated output current (A)
Motor power output (kW) 2)
Voltage class
6.6kV output capacity (kVA)
Rated output current (A)
Motor power output (kW) 2)
Output frequency range (Hz)
Overload capacity
Main circuit
Control circuit
Tolerance
Power factor of main power supply
Efficiency
Control method
Frequency precision
Torque characteristics of load
Acceleration/deceleration time
Main control function
Main protective function
Data transmission
Display
Control method
Analog
Digital
Cell bypass
Control device redundancy
Control power redundancy
Input transformer
Protection degree of enclosure
Panel construction
Cooling
Panel color
Ambient temperature
Humidity
Noise level
Altitude
Vibration
Installation
Applications
Standards
2850
396
2460
3400
473
2930
3750
525
3240
4400
619
3500
5000
707
4000
2500
347
2160
2200
306
1900
1900
264
1630
1550
216
1310
1250
174
1040
950
132
790
750
105
630
640
89
530
500
70
410
380
53
310
250
35
205
400
35
330
600
53
495
800
70
675
1000
88
835
1200
105
1000
1500
132
1270
2000
175
1700
2500
219
2130
3000
263
2590
3500
307
3020
4000
350
3450
4500
394
3930
5400
473
4500
6000
525
5000
7000
619
5600
8000
707
6400
Input
Output
Co
ntr
ol sp
eci
ati
on
Operation
board
Signal
interface
Co
nstr
uct
ion
Mai
n r
elia
bilit
yfu
nct
ion
(Opt
ion)
Am
bie
nt
con
str
uct
ion
s
>>Outline and Dimensions
HYUNDAI INVERTER 13
[ Unit:mm ]
[ Unit:mm ]
[ Unit:mm ]
A A"
W
Front View Side View (Right)
Section A-A"
D50
2300
2350
H
A A"
W D
50
2300
2350 H
Front View Side View (Right)
Section A-A"
Section A-A"
Front View
A A"
W D50
2300
2350 H
Side View (Right)
A Type
B Type
C Type
>>Outline and Dimensions
14 HYUNDAI INVERTER
ModelVoltage W D H
N5000 - 0155 L 5 200 35 A 2000 1200 2800
N5000 - 0245 L 5 300 53 A 2000 1200 2800
N5000 - 0325 L 5 400 70 A 2400 1200 2800
N5000 - 0410 L 5 500 88 A 2400 1200 2800
N5000 - 0490 L 5 600 105 B 3400 1200 2800
N5000 - 0620 L 5 750 132 B 3500 1200 2800
N5000 - 0835 L 5 1000 175 B 3700 1200 2800
N5000 - 1040 L 5 1250 219 B 3800 1200 2800
N5000 - 1270 L 5 1500 263 B 3900 1400 2800
N5000 - 1500 L 5 1750 307 B 3950 1500 2800
N5000 - 1710 L 5 2000 350 B 4000 1500 2800
N5000 - 1940 L 5 2250 394 B 4100 1500 2800
N5000 - 2250 L 5 2700 473 B 4500 1500 3250
N5000 - 2500 L 5 3000 525 B 5000 1500 3250
N5000 - 2800 L 5 3500 619 B 5900 1700 3300
N5000 - 3200 L 5 4000 707 B 5900 1700 3300
N5000 - 0205 M 5 250 35 B 3120 1200 2800
N5000 - 0310 M 5 380 53 B 3220 1200 2800
N5000 - 0410 M 5 500 70 B 3650 1200 2800
N5000 - 0530 M 5 640 88 B 3650 1200 2800
N5000 - 0630 M 5 750 105 C 4360 1200 2800
N5000 - 0790 M 5 950 132 C 4360 1400 2800
N5000 - 1040 M 5 1250 175 C 4560 1400 2800
N5000 - 1310 M 5 1550 219 C 4960 1400 2800
N5000 - 1630 M 5 1900 263 C 5010 1400 2800
N5000 - 1900 M 5 2200 307 C 5210 1500 2800
N5000 - 2160 M 5 2500 350 C 5360 1500 2800
N5000 - 2460 M 5 2850 394 C 5560 1500 2800
N5000 - 2930 M 5 3400 473 C 6100 1500 3250
N5000 - 3240 M 5 3750 525 C 6100 1500 3250
N5000 - 3500 M 5 4400 619 C 7500 1700 3300
N5000 - 4000 M 5 5000 707 C 7500 1700 3300
N5000 - 0330 H 5 400 35 B 3400 1200 2800
N5000 - 0495 H 5 600 53 B 3500 1200 2800
N5000 - 0675 H 5 800 70 B 4000 1200 2800
N5000 - 0835 H 5 1000 88 B 4000 1200 2800
N5000 - 1000 H 5 1200 105 C 5000 1200 2800
N5000 - 1270 H 5 1500 132 C 5000 1400 2800
N5000 - 1700 H 5 2000 175 C 5200 1400 2800
N5000 - 2130 H 5 2500 219 C 5600 1400 2800
N5000 - 2590 H 5 3000 263 C 5650 1400 2800
N5000 - 3020 H 5 3500 307 C 5850 1500 2800
N5000 - 3450 H 5 4000 350 C 6000 1500 2800
N5000 - 3930 H 5 4500 394 C 6200 1500 2800
N5000 - 4500 H 5 5400 473 C 7000 1500 3250
N5000 - 5000 H 5 6000 525 C 7000 1500 3250
N5000 - 5600 H 5 7000 619 C 9200 1700 3300
N5000 - 6400 H 5 8000 707 C 9200 1700 3300
Type[ kVA ] [ A ]
3300V
4160V
6600V
■Panel size for 50Hz
※ As for the non-standard size, please contact Hyundai Heavy Industries Co.,Ltd.
HYUNDAI INVERTER 15
ModelVoltage W D H
N5000 - 0155 L 6 200 35 A 2000 1100 2800
N5000 - 0245 L 6 300 53 A 2000 1100 2800
N5000 - 0325 L 6 400 70 A 2400 1100 2800
N5000 - 0410 L 6 500 88 A 2400 1100 2800
N5000 - 0490 L 6 600 105 B 3300 1100 2800
N5000 - 0620 L 6 750 132 B 3300 1100 2800
N5000 - 0835 L 6 1000 175 B 3600 1200 2800
N5000 - 1040 L 6 1250 219 B 3600 1200 2800
N5000 - 1270 L 6 1500 263 B 3800 1400 2800
N5000 - 1500 L 6 1750 307 B 3800 1400 2800
N5000 - 1710 L 6 2000 350 B 3900 1400 2800
N5000 - 1940 L 6 2250 394 B 3900 1400 2800
N5000 - 2250 L 6 2700 473 B 4500 1500 3250
N5000 - 2500 L 6 3000 525 B 4600 1500 3250
N5000 - 2800 L 6 3500 619 B 5700 1700 3300
N5000 - 3200 L 6 4000 707 B 5800 1700 3300
N5000 - 0205 M 6 250 35 B 3020 1100 2800
N5000 - 0310 M 6 380 53 B 3020 1100 2800
N5000 - 0410 M 6 500 70 B 3410 1100 2800
N5000 - 0530 M 6 640 88 B 3450 1100 2800
N5000 - 0630 M 6 750 105 C 4160 1100 2800
N5000 - 0790 M 6 950 132 C 4160 1100 2800
N5000 - 1040 M 6 1250 175 C 4340 1400 2800
N5000 - 1310 M 6 1550 219 C 4340 1400 2800
N5000 - 1630 M 6 1900 263 C 4440 1400 2800
N5000 - 1900 M 6 2200 307 C 4740 1400 2800
N5000 - 2160 M 6 2500 350 C 5040 1400 2800
N5000 - 2460 M 6 2850 394 C 5040 1400 2800
N5000 - 2930 M 6 3400 473 C 5900 1500 3250
N5000 - 3240 M 6 3750 525 C 5900 1500 3250
N5000 - 3500 M 6 4400 619 C 7200 1700 3300
N5000 - 4000 M 6 5000 707 C 7200 1700 3300
N5000 - 0330 H 6 400 35 B 3300 1100 2800
N5000 - 0495 H 6 600 53 B 3300 1100 2800
N5000 - 0675 H 6 800 70 B 3900 1100 2800
N5000 - 0835 H 6 1000 88 B 3900 1100 2800
N5000 - 1000 H 6 1200 105 C 4900 1100 2800
N5000 - 1270 H 6 1500 132 C 4900 1100 2800
N5000 - 1700 H 6 2000 175 C 5100 1400 2800
N5000 - 2130 H 6 2500 219 C 5100 1400 2800
N5000 - 2590 H 6 3000 263 C 5200 1400 2800
N5000 - 3020 H 6 3500 307 C 5700 1400 2800
N5000 - 3450 H 6 4000 350 C 5900 1400 2800
N5000 - 3930 H 6 4500 394 C 6100 1400 2800
N5000 - 4500 H 6 5400 473 C 7000 1500 3250
N5000 - 5000 H 6 6000 525 C 7000 1500 3250
N5000 - 5600 H 6 7000 619 C 9000 1700 3300
N5000 - 6400 H 6 8000 707 C 9000 1700 3300
Type[ kVA ] [ A ]
3300V
4160V
6600V
■Panel size for 60Hz