- ECCO Supply. Controls/Armstrong Monitoring.pdf · ECCO is proud to be a member of: ASHRAE...

14
ARMSTRONG MONITORING www.armstrongmonitoring.com ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. www.ashrae.org HRAI Heating, Refrigeration and Air Conditioning Institute of Canada www.hrai.ca HARDI Heating, Airconditioning & Refrigeration Distributors International www.hardinet.org SMACNA Sheet Metal and Air Conditioning Contractors’ National Association www.smacna.org SPIDA Spiral Duct Manufacturers Association www.spida.org ECCO Supply www.eccosupply.ca 7-1 Effective: March 2010 INDEX ACCESSORIES AMC C SERIES CALIBRATION KIT ....................................................................................................................... 7-14 AMC IM331 (INTERFACE MODULE) DISPLAY AND RELAY MODULE ................................................... 7-13 AMC RAM3 REMOTE ALARM/ACKNOWLEDGE MODULE ........................................................................ 7-13 GAS CYLINDER (SOLD SEPARATELY) ................................................................................................................ 7-14 INTRODUCTION ................................................................................................................................................................ 7-2 MONITORS 1A SERIES SINGLE/DUAL CHANNEL GAS MONITOR..................................................................................... 7-3 AMC 1400 FOUR CHANNEL GAS MONITOR ..................................................................................................... 7-4 AMC 1800 MULTI CHANNEL CONTROLLER ...................................................................................................... 7-5 SENSORS AND TRANSMITTERS AMC DTR SERIES NON-INTRUSIVE MAGNETIC CALIBRATION MULTI-SENSOR/TRANSMITTER ..................................................................................................................... 7-11 AMC GENIR SERIES INFRARED REFRIGERANT SENSOR/TRANSMITTER ............................................ 7-12 AMC VERSATOX GAS SENSOR/TRANSMITTER CO, NO 2 , 0 2 , CL 2 ............................................................. 7-10 SYSTEMS AMC 1220 SERIES MULTI DROP GAS SENSOR MODULE ............................................................................. 7-7 AMC-1AD1/D2 SINGLE/DUAL ZONE MULTIDROP GAS MONITOR ......................................................... 7-6 AMC-CD-2 HUMAN OCCUPANCY DETECTOR ................................................................................................. 7-9 AMC 122 DUAL CARBON MONOXIDE AND NITROGEN DIOXIDE MULTI FUEL EXHAUST SENSING MODULE............................................................................................................................ 7-8 This section contains product and technical information only. For additional information and product pricing please contact your local ECCO Supply Sales Branch.

Transcript of - ECCO Supply. Controls/Armstrong Monitoring.pdf · ECCO is proud to be a member of: ASHRAE...

Page 1: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

ARMSTRONG MONITORINGwww.armstrongmonitoring.com

ECCO is proud to be a member of:

ASHRAEAmerican Society of

Heating, Refrigerating, and Air-Conditioning Engineers, Inc.

www.ashrae.org

HRAIHeating, Refrigeration and Air Conditioning Institute of Canada

www.hrai.ca

HARDIHeating, Airconditioning &Refrigeration Distributors

International www.hardinet.org

SMACNASheet Metal and Air

Conditioning Contractors’ National Association www.smacna.org

SPIDASpiral Duct

Manufacturers Association

www.spida.org

ECCO Supply www.eccosupply.ca 7-1

Effective: March 2010

INDEXaccessories

amc c series calibration kit ....................................................................................................................... 7-14amc im331 (interface module) display and relay module ................................................... 7-13amc ram3 remote alarm/acknowledge module ........................................................................ 7-13gas cylinder (sold separately) ................................................................................................................ 7-14

introduction ................................................................................................................................................................ 7-2monitors

1a series single/dual cHannel gas monitor ..................................................................................... 7-3amc 1400 four cHannel gas monitor ..................................................................................................... 7-4amc 1800 multi cHannel controller ...................................................................................................... 7-5

sensors and transmittersamc dtr series non-intrusive magnetic calibration multi-sensor/transmitter ..................................................................................................................... 7-11amc genir series infrared refrigerant sensor/transmitter ............................................ 7-12amc versatoX gas sensor/transmitter co, no2, 02, cl2 ............................................................. 7-10

systemsamc 1220 series multi drop gas sensor module ............................................................................. 7-7amc-1ad1/d2 single/dual zone multidrop gas monitor ......................................................... 7-6amc-cd-2 Human occupancy detector ................................................................................................. 7-9amc 122 dual carbon monoXide and nitrogen dioXide multi fuel eXHaust sensing module............................................................................................................................ 7-8

This section contains product and technical information only.for additional information and product pricing please contact your local ecco supply sales branch.

Page 2: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

ECCO Supply7-2 www.eccosupply.ca

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

ARMSTRONG MONITORINGas a leading manufacturer of gas detection and hazardous gas monitoring equipment, armstrong monitoring's commitment to ensuring safer environments, healthier air, and reduced environmental impact has helped forge their reputation as a trusted gas monitoring and detection solution provider with global reach.intrinsic adaptability combined with a wide variety of gas sensor options means that armstrong monitoring systems can be tailored to meet the requirements of almost any application. from mines to refineries, naval vessels to schools, automotive dealerships and parking garages to municipal water/sewer facilities, armstrong monitoring has the solution for your gas detection requirements.

ApplIcATIONSby combining years of experience with inherently flexible gas detection products, armstrong monitoring is able to support one of the broadest arrays of gas detection and hazardous gas monitoring applications in the industry.• Automotivedealerships• Parkinggarages• Schools• Municipalwater/sewerfacilities• Mines• Refineries• Navalvessels• Manymore

WARRANTyall armstrong equipment is warranted against defects in materials and workmanship for two years from date of delivery, except sensors. please contact ecco supply for sensor warranty. during the warranty period, armstrong monitoring will repair or replace components that prove, in their opinion, to be defective. armstrong monitoring is not liable for auxiliary interfaced equipment, nor consequential damage. all warranty items must be returned by prepaid freight.

Page 3: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

www.eccosupply.ca 7-3ECCO Supply

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

Enclosure: asa 61 gray enameled 16 gauge steelSupply Voltage: 120 vac or 240 vac, 60 HzRelay contacts: up to 5 dpdt 10a @ 250 vac, res max

relays, up to two set points per channel and optional fault relay

calibration: factory calibrated in lel, ppm or % by volumeDimensions: 20.32cm H x 20.32cm w × 12.70cm d

(8" × 8" × 5")Weight: 4.54 kg (10 lb)Operating Temperature: -20°c to 40°c (-4°f to 104°f)Storage Temperature: -40°c to 65°c (-40°f to 149°f)Monitor Warranty: two yearsIndicators per channel:red led – Alarmyellow led – Warninggreen led• LEDOn–Run• LEDFlashing–Fault• LEDOff–OffFunctional Features: alarms disabled during warm up system test switch user selectable: • Activationdelays,fiveminutesforWarning

and/or alarm set points • MinimumRunTimer • 95dBaAudioalarmwithWarning

and/or alarm set points 4 external mounting holes Hinged door optional latching relays with manual reset optional enclosure key lock optional dual 4-20ma analog outputconcentration Display – optionalApprovals: csa 22.2 no. 205 and ul 508a

the gas monitor 1a series is a monitor with one or two channels incorporating state of the art sensing technology using micro-controller based design to provide accurate gas detection capabilities within a compact package.the gas monitor 1a delivers up to two channels of gas detection. it offers low cost and versatility, turning even the simplest job into big savings. the monitor has a robust enclosure designed to provide optimal gas flow ensuring optimum response. the gas monitor 1a is a small package with big capabilities.

Key Features:• Detectionforover30typesofgases• Flexiblesensorinterfacesperchannel • 4-20mAtransmitterinput • Voltageinput • Externalsensor • Onboardsensor• Upto16AMC122Xseriesmultidropmodules

within up to two zones• Easytoinstallandoperate• Upto5relayswithratingsupto10A@250VAC,Res. • Upto4alarmrelays • Upto1faultrelays• RS232COMportforloggingandtrending• Replacementsensorscanbepre-calibrated,

providing quick and easy maintenanceNorth American Made

MONITORS1A SERIES SINGlE/DUAl cHANNEl GAS MONITOR

Page 4: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

ECCO Supply7-4 www.eccosupply.ca

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

Inputs: up to 4 × 4-20maAnalog Outputs: up to 4 × 4-20maDisplay: vfd provides continuous readout of gas

concentration, alarm and failure conditions, and is used as a display for changing programming parameters. leds indicate alarms and sensor failure.

Display Engineering Units: gas concentrations in ppm, ppb, %lel, % by volume

Alarm Activation Delay: adjustable 0-60 minutesRelay Outputs: up to 16 × spdt 6 amp dry contacts.

programmable normally energized or de-energized, latching or non-latching, voting logic, and minimum run timer, up to 60 minutes

Audible Alarm: optional external alarm, programmable to energize on all or any detected alarms

Fail Relay: a normally energized global fail relay output (low voltage only), not affected by programmed delays or run times

Keypad: internal keypads for unit programming and user interface (external optional)

Enclosure: water resistant fiberglass enforced polyesterDimensions: 27cm w × 35cm × H × 19cm d

(10.5” w × 14” H × 7.5” d)Supply Voltage Requirement: 110 vac, 60 HzOperating Temperature: 0°c to 40°c (32°f to 104°f)Monitor Warranty: two years

a compact system for up to four sensor/transmitters, the amc 1400 monitoring panel provides features normally found in much larger, more expensive packages.an easy to read vacuum fluorescent display provides continuous gas concentration and alarm indication for each of four sensors. Housed in a fiberglass enforced polyester enclosure, the fully programmable amc 1400 is designed to permit the user to configure relays, alarms and timers to specific applications.engineering units are selectable from an internal memory library, including ppm, ppb, %lel, and % volume.the versatile amc 1400 can be used with any of armstrong’s wide array of hazardous gas sensor/transmitters.

MONITORS (cont’d)AMc 1400 FOUR cHANNEl GAS MONITOR

Page 5: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

www.eccosupply.ca 7-5ECCO Supply

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

the amc 1800 is a programmable multi-channel gas monitor. combined with armstrong’s wide selection of gas sensor/transmitters, it provides an economical and powerful gas monitoring system. standard features include powerful programming capabilities, a digital display, up to 32* sensor/transmitter inputs, and internal audible alarm.powerful programming capabilities allow the end-user maximum flexibility. the unit can be programmed with up to three levels of ascending or descending alarm concentration threshold modes. engineering units and gas labels are selectable from an internal memory library including ppm (parts per million), ppb (parts per billion), %lel (lower explosive limit), %vol. (volume) and other external parameters such as multi-drop sensor modules. also available is a bar graph representation of full scale for non-numeric thresholds.full-scale is field adjustable when alarming parameters change. an adjustable hysteresis, from 0 to 5% of full scale, is provided to prevent alarm and relay oscillation when a threshold concentration is present. there are up to four dedicated relays per sensor/transmitter input. each of three alarm levels are programmable with up to 60 minutes of time delay and/or minimum run time per level. output relays can be programmed energized or de-energized permitting true fail-safe operation and a minimum count value may be activated before the relay is energized to provide voting logic.the digital display not only scrolls through the various sensor/transmitter inputs and alarm conditions but allows program review by the user in the field. equipped with security codes, the display is used in conjunction with the adjacent programming keypad to edit the available monitoring options. the amc 1800’s standard display is a highly visible vfd (vacuum fluorescent display), but an “optional” lcd (liquid crystal display) is also available.

each i/o (input/output) card can accept up to eight sensor/transmitter inputs and manage 32 relays outputs. display cards can accept up to four* i/o cards for a maximum of 32* sensor/transmitters and 256 relays. a mirrored 4-20 ma output corresponding to each input is also standard.a common fail relay output is standard to provide remote annunciation system fail conditions. an internal audible alarm interfaces with the systems alarm conditions to provide local indications.AMc-1800-41 up to 8 inputsAMc-1800-42 up to 16 inputsAMc-1800-43 up to 24 inputsAMc-1800-44 up to 32 inputs*Custom units up to 64 inputs are available.

MONITORS (cont’d)AMc 1800 MUlTI cHANNEl cONTROllER

Page 6: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

ECCO Supply7-6 www.eccosupply.ca

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

Enclosure: asa 61 gray enameled 16 gauge steelSupply Voltage: 120 vac, 60 HzRelay contacts: up to 4 dpdt 10a @ 250 vac res. max

relays, up to two thresholds per channel and optional fault relay

calibration: see amc-122X sensor module manualDimensions: 20.32cm H × 20.32cm w × 12.70cm d

(8" × 8" × 5")Weight: 4.54 kg (10 lb)Operating Temperature: -20°c to 40°c (-4°f to 104°f)Storage Temperature: -40°c to 65°c (-40°f to 149°f)Monitor Warranty: two yearsIndicators per Zone:red led – Alarmyellow led – Warninggreen led • LEDOn–Run • LEDFlashing–Fault • LEDOff–OffFunctional Features: alarms disabled during warm up system test switch user selectable: • Activationdelays,fiveminutesforWarning

and/or alarm set points • MinimumRunTimer • 95dBaAudioalarmwithWarningand/orAlarmset

points Hinged door optional latching relays with manual reset optional enclosure key lockconcentration Display – optionalApprovals: csa 22.2 no. 205 and ul 508a

the amc-1ad1/2 monitor provides one or two zones of detection in conjunction with the amc-122X series of multidrop sensor modules. it incorporates state of the art sensing technology using micro-controller based design to provide accurate gas detection capabilities within a compact package.delivering up to two zones of gas detection, the amc- 1ad1/2 offers low cost and versatility, turning even the simplest job into big savings.Key Features:• Upto8AMC-122Xseriesmultidropmodulesperzonefor

a maximum of 16 for two zones• Easytoinstallandoperate•Upto4relayswithratingsupto10A@250VACRes.• RS232COMportforloggingandtrendingOrdering codes:AMc-1AD1 (single zone, two relay version)AMc-1AD2 (dual zone, four relay version)

North American Made

SySTeMSAMc-1AD1/D2 SINGlE/DUAl ZONE MUlTIDROp GAS MONITOR

Page 7: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

www.eccosupply.ca 7-7ECCO Supply

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

for gas monitoring applications requiring a large number of sensors, installation costs represent a significant share of total project expenses. in an effort to lower these costs, amc developed the amc 1220 series multi drop gas sensor module. compatible with the amc 1022d series, sensors can be wired in series utilizing low power, three wire cabling. dual wiring inputs combined with multi zone capabilities, permit an unlimited range of configurations, thereby minimizing both installation time and materials.up to eight amc 1220s of different sensor types can be connected to a single 1022d zone with a maximum of 150ft between sensors and panel. power supplies can be upgraded allowing more sensors per zone. local indications for low and high alarm, as well as, power and sensor failure make the amc 1220 an economical solution to your gas monitoring needs.

Note: This system is for use in non-hazardous locations.

SySTeMS (cont’d)AMc 1220 SERIES MUlTI DROp GAS SENSOR MODUlE

amc 1225 amc 1228-28 amc 1228-20 Detectable Gas: Combustible gas* Nitrogen dioxide Carbon monoxideSensor Type Solid state Electrochemical cell Electrochemical cellRange: 0-50% LEL 0-10 PPM 0-100 PPMSensor Warranty Two years One year Three yearsEnclosure: PVCInstallation Wiring: Three wire 18 awg shieldedDimensions: 10.2 cm H × 10.2 cm W × 6 cm D (4" W × 4" H × 2.25" D)Operating Temperature: 0°C to 40°COperating Humidity: 0-99% non-condensing

LED Indication:High alarm – red LED, Low alarm – yellow LED,Power – green LED (on), Fail – green LED (off )

Page 8: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

ECCO Supply7-8 www.eccosupply.ca

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

Sensor Types: dual electrochemical co, no2

Output Signal: standard stepped, common for co, no2 and “comfort zone” Fail: 0 vdc or 0 ma* Normal: 1 vdc or 4 ma* low: 2 vdc or 8 ma* High: 3 vdc or 12 ma* comfort Zone: 2 vdc or 8 ma*

*Max 250 Ω load on current signallED Indicators: Green: power (steady)/fail (flashing) Red: co high (steady)/low (flashing) Red: no2 high (steady)/low (flashing) Amber: comfort zone alarmStandard Alarms/Signal Trip points: cO: low 25 or 35 ppm, high 100 ppm NO2: low 1 ppm, high 3 ppm comfort Zone: alarm trip point is user adjustable at nuisance

concentrations. active when diesel fumes are present.Range: cO: 0-100 ppm

NO2: 0-3 ppmTime Delays: minimum run time: five minutes,

user selectable alarm delay: five minute, user selectable delay on power up: 30 seconds

Operating Temperature Range: -20°c to +40°cAmbient Humidity: 10%-95% rH non-condensingSensor life: > five years in air for co (three year warranty)

> three years in air for no2 (one year warranty)Wiring: three conductor, shielded cablepower Requirement: 12-24 vdc 35 ma (voltage configuration)

55 ma (current configuration)Sensor Response Time: co: 90% response in less than

two minutes no2: 90% response in less than 30 seconds

central Monitor Requirement: designed for compatibility with existing amc and most

competitors’ analog, digital or computer interfaced systems, including a majority of present installations.

Enclosure: pvc, standard venting, optional water resistant venting

the amc 1222 combines electrochemical carbon monoxide and nitrogen dioxide sensors to provide the ultimate solution to any vehicle exhaust monitoring application.providing cost effective solutions for single or multi-point applications, the amc 1222’s voltage or current output can be interfaced with standard armstrong panels, and most competitors’ equipment for cost effective upgrades. Dual sensor and multidrop-ready configuration ensure that wiring and controller requirements are substantially reduced when compared to standard systems.

cOMFORT ZONE TEcHNOlOGy:diesel exhaust has historically been very difficult to monitor. due to the wide variety of pollutants, including carbon monoxide, oxides of nitrogen, sulfur compounds, as well as carcinogenic particulates, it is impractical to attempt to monitor for all possible toxins. carbon monoxide, nitrogen dioxide, and carbon dioxide have been historically used as general indicators of air quality in these applications. because of the widely varying composition of diesel exhaust, this method has resulted in inconsistent ventilation control as well as worker discomfort and complaints.by applying a combination of carbon monoxide and nitrogen dioxide sensing, with an interactive logic function, an effective solution can be provided cost effectively for diesel as well as varied fuel facilities. simple user adjustment allows subjective sensitivity adjustment for control of air quality issues.in using this logic, increased sensitivity is engaged only when trace nitrogen dioxide levels are present, indicating the presence of diesel vehicles. this acts as an effective energy saving feature, active only with diesel exhaust.

SySTeMS (cont’d)AMc 122 DUAl cARbON MONOXIDE AND NITROGEN DIOXIDE MUlTI FUEl EXHAUST SENSING MODUlE WITH cOMFORT ZONE TEcHNOlOGy

Page 9: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

www.eccosupply.ca 7-9ECCO Supply

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

Applications: • ContainerPorts • SecurityAgencies • CorrectionalFacilities • TransportSecurity • LawEnforcement • SearchandRescue • HomelandSecurity

Features: • SpecifictoCO2 with no interferences

or poisons • Internalhighgrade,lowpowersample

draw pump • Quickconnectsamplinghardware • Longliferechargeablebattery • Self-resealing,kinkresistant

sample hose • Assortedprobetipssuitedforvarious

applications • 2yearwarrantyfor organizations involved in cross border shipments, stowaways can present an increasingly costly problem. under current law, carriers often become liable for a fine, plus the stowaways’ housing, food, healthcare, supervision, legal representation and repatriation costs.this has led the armstrong monitoring corporation to develop the amc-cd-2 Human occupancy detector. by monitoring for elevated co2 levels in shipping containers, a reliable indication of human occupancy is provided, allowing early detection at the point of departure.the amc-cd-2 uses state-of-the-art infrared sensing technology to provide accurate, parts per million indication in a low maintenance package. an internal pump extracts an air sample through a customized probe assembly. numerous attachments allow samples to be taken through small apertures or rubber seals in a wide variety of vessels, without compromising integrity of either container or cargo.time means money, and when cargo terminals are loading two or three containers per minute, the amc-cd-2 permits quick and easy testing, realizing savings in both the short and long term.the sensor uses a beam of infrared light to probe a sample of air. the amount of light absorbed is a function of the concentration of co2 in the sample. the process is specific to the absorption bands of co2, and will therefore not respond to any other gases.

armstrong’s amc-cd-2 has been credited with saving countless lives through rescue facilitated by the rapid detection of concealed personnel. in addition to being a powerful analytical tool, the amc-cd-2 has proven itself as a strong deterrent to incidents of human concealment in locations where the technology has been employed.

Specifications:Measurement Technique: non-dispersive infrared (ndir)Range: 0-5000 ppm co2

Sample Rate: approximately 500 ml/minbattery life: 12 hours per rechargeDimensions: 7cm × 14cm × 19cm

2.76” × 5.51” × 7.48”Operating Temperature: 10°c to 50°cOperating Humidity: 0-95% rHAccuracy: ±5% of full scaleRepeatability: ±2% of full scaleWeight: 1.6 kg

3.5 lbs

Optional:Recorder Output: 0.1-2.5 vdc

parts list:AMc-cD2-01: probe assembly complete with handle,

fittings, filter and tubingAMc-cD2-03: leather caseAMc-cD2-06: 120 vac/12 dc adapter/ re-chargerAMc-cD2-07: shoulder strapAMc-cD2-09: chest pack harnessAMc-cD2-10: needle assortment (includes 6 needles,

various gauge)AMc-cD2-11: tip adaptorAMc-cD2-126: particulate filter

SySTeMS (cont’d)AMc-cD-2 HUMAN OccUpANcy DETEcTOR

Page 10: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

ECCO Supply7-10 www.eccosupply.ca

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

product Specifications:Sensor Type: electrochemical sensorSignal Output: 4-20ma analog outputEnclosure: absSupply Voltage: 12-30 vdc, optional12-24 vaccalibration: field calibration or quick-connect

return to factoryDimensions: 3.75" diameter × 2.2"HOptional Alarm Relay: spst 2a@ 30vdc resistive.

configurable for no or ncWeight: 150 g (0.33 lbs)Versatile Detection. the amc versatox has the capacity to provide gas detection for a wide range of hazardous conditions. carbon monoxide and nitrogen dioxide from sources of combustion, oxygen deficiency and chlorine from pool chlorination, are all common applications for this versatile device.the optional features on the amc versatox include concentration readout, ac power, onboard alarm relay, and duct mountable enclosure.

Features: • Standard4-20mAoutput • 2-wirelooppoweredbasemodel • Long-lifecarbonmonoxidesensor • RoHScompliant • Factorycalibrationformanygasesandranges • Optional3-digitconcentrationreadout • Highimpactplasticenclosure(ABS)

for surface mounting • Knock-outsforfieldwiring • Lowcostselfcontainedmonitoringsolution • Accurateandreliable • Easytoinstallandmaintainthe amc versatox is designed to be fully compliant with roHs* guidelines.* The RoHS Directive stands for ”the restriction of the use of certain

hazardous substances in electrical and electronic equipment”. This Directive bans the use of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants.

SeNSORS AND TRANSMITTeRSAMc VERSATOX GAS SENSOR/TRANSMITTER cO, NO2, 02, cl2

common versatox versions

sensor eLement Part # range

oPerating Humidity

sensor warranty

tyPicaL sensor

LiFe:oPerating

temPeratureAMC VersaTox CO 91AG 0-100, 0-200 and

0-300 PPM CO15-90% RH (constant)0-98% RH (intermittent)

3 years > 4 years -20°C to 50°C*

AMC VersaTox NO2 98AE 0-10 PPM NO2 15-90% RH (constant)0-98% RH (intermittent)

1 year > 2 years -20°C to 50°C*

* Display rated for low temp of 0°C

AMc VersaTox part Numbering Schemeestablishing a product order code for your amc versatox is quick and easy. simply use the matrix below or contact your ecco supply sales representative for assistance or additional information.

amc-vt disPLayreLay/ac voLtage encLosure range sensor Part #

1 = No 1 = No 1 = Wall Mount A = 0 to 1 91AG (CO)2 = Yes 2 = Yes 2 = Duct Mount B = 0 to 3 98AE (NO2)

3 = WM PCB only C = 0 to 10 70AD (O2)4 = DM PCB only D = 0 to 25 97AC (CI2)

E = 0 to 50F = 0 to 100G = 0 to 200H = 0 to 300I = 0 to 400J = 0 to 500K = 0 to 999

Examples:amc-vt111f-91ag 0 to 100 ppm co, wall mount, no display, no relay

amc-vt211c-98ac 0 to 10 ppm no2, wall mount with display and relay/ac

Page 11: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

www.eccosupply.ca 7-11ECCO Supply

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

the armstrong monitoring corporation’s dtr transmitter is a truly “state of the art” device. it accepts low power sensors and functions in a two wire 4-20 ma “sink” mode, or provides excitation for higher power consuming sensors in a three wire 4-20 ma “source” mode. inputs include electrochemical toxic/o2 sensors, catalytic lel sensors, resistive bridge sensors and many other voltage and current input sources.a dual transmitter mode allows one electrochemical sensor and one lel sensor into the same dtr. sensor data is scaled into the appropriate engineering units and displayed numerically, or graphically as bar-graphs and trends, on a backlit graphic lcd.a “smart sensor” 12c interface allows a tiny memory chip in the sensor head to provide the dtr with parameters such as calibration, range, engineering units and important dates. a real time clock and calendar allow logging events such as alarms and calibrations. calibration offset and gain factors may be viewed and are useful for predicting sensor “end of life” conditions.traditional “simple sensors” without integrated data storage are also easily accepted. operator interface is via a menu driven magnetic keypad allowing complete control of the system without opening the enclosure. there are no potentiometers and all adjustments are performed through the keypad.dtr options include 5a form c relays for the two level alarms and fault alarm. this pcb includes a modbus® rs-485 serial port. visual led alarm & rs-485 tx / rx indicators located on the front panel are standard.users may program power warm up and calibration exit delays to avoid false alarms. delays hold outputs at zero until sensor signals stabilize. in/out alarm trip delays may also be programmed. a security menu allows entry of an authorization code to lock critical parameters.

Features: • Availableinelectrochemical,LEL,anddual

electrochemical/lel models. lel channel also accepts 4-20 ma with special order factory configuration.

• “Smart”sensorinterfaceallowscalibrationdata,sensortype, range and many other variables to be stored inside the sensor head. new or recently calibrated sensors are automatically recognized.

• Allows“oneman”sensorcalibrationinhazardousareaswithout area declassification

• Requiresonlyasimplemagneticwand.Nootherspecial electronic devices are needed

• Providescontinuousreadoutwith.6"tallengineeringunits and graphically as a 30 minute trend or bar-graph

• FrontpanelalarmLEDindicatorsarestandardequipment

• Availableoptionincludesacombined5Aform“c” HigH-warn-fault alarm contacts and rs-485 modbus® interface

• 4-20mAoutputsendsconstant3.0mA“InCal”signalduring calibration periods

• Userprogrammable“Powerup”&“PostCal”Delaymodes lock output at zero to allow sensor stabilization and prevent erroneous alarm trips

• Standard“FaultSupervision”circuitrycontinuouslymonitors for failed sensor; 4-20 ma output transmits 2 ma during failures

• Securitymodeallowslockingofcriticalparameters • TheNEMA7(Explosionproof )instrumentenclosure

also meets nema 4 requirements with the standard “o” ring

Analog Outputs: dtr/ec has standard 2-wire 4-20 ma current sink output.

(2-wire 4-20 ma not available with dtr/lel or 10-0234 option) dtr lel models have 3-wire 4-20 ma current source output. with nominal 24 vdc power supply, 2-wire max loop r is 500 ohms and 3-wire max loop r is 750 ohms.

Temperature Drift: less than .1% per °c over ambient temperature range

Display: 64 × 128 pixel lcd displays 30 minute trend, bargraph & large engineering units. backlight active in 3-wire 4-20 ma mode.

power Supply: 10-30 vdc at less than .75 watts in 2-wire 4-20 ma 10-30 vdc at less than 3 watts in 3-wire 4-20 ma with relays

calibration Range and Resolution: zero = ±15% of full scale range with .1% resolution span = with .1% resolutionHousing: instrument enclosures suitable for class 1, div 1, 2

group bcd (nema 4×/7)Ambient Temperature Range: -40°c to 60°c (-40°f to 140°f)

(sensor dependant)Transmitter Warranty: two yearsRelay/Digital Output Option: -10-0234 relays are form c 5a @ 30 vdc resistive rs-485 is 2-wire modbus® rtu

SeNSORS AND TRANSMITTeRS (cont’d)AMc DTR SERIES NON-INTRUSIVE MAGNETIc cAlIbRATION MUlTI-SENSOR/TRANSMITTER

Page 12: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

ECCO Supply7-12 www.eccosupply.ca

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

Sensing Method: ndir (non-dispersive infrared)Gas: HalocarbonsRange: 0-1000 ppmSensitivity: ± 1 ppm at 25°c, 45% rHResolution: 1 ppmExternal power Source: 10-24 vdcOutput Signals: 4-20 maOperating Temperature: -40°c to 50°c (-40°f to 120°f)Ambient Humidity: 0% to 85% rH (non-condensing)Storage Temperature: -40°c to 70°c (-40°f to 158°f)External Dimensions: 21 cm × 12 cm × 6.4 cm

(8.25” × 4.75” × 2.5”)

the amc genir is a gas sensor/transmitter for the continuous monitoring of any halocarbon in the air. it is the ideal sensor/transmitter for the detection of any of common cfc, Hfc, Hcfc, or Halon compounds.it is available factory calibrated using a selection of refrigerants. a ventilated wall mount enclosure houses the sensor.

SeNSORS AND TRANSMITTeRS (cont’d)AMc GENIR SERIES INFRARED REFRIGERANT SENSOR/TRANSMITTER

reFrigerant gas

amc Part number

r-11 genir-r11 r-12 genir-r12 r-22 genir-r22 r-23 genir-r23 r-114 genir-r114 r-123 genir-r123 r-134a genir-r134a r-402a genir-r402a r-404a genir-r404a r-407c genir-r407c r-408a genir-r408a r-409a genir-r409a r-410a genir-410a r-500 genir-r500 r-502 genir-r502 r507a genir-r507a ammonia – nH3 genir-nH3

Note: If refrigerant of concern is not shown, please contact ECCO Supply.

Page 13: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

www.eccosupply.ca 7-13ECCO Supply

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

power Requirements: 12 vdcDimensions: 6.6"H × 3.8"w × 3.9"d

(16.8cm H × 9.7cm × 9.9cm d)Material construction: f.r p.Relay: spdt, 10a @ 240 vdc /30 vdcVisual Alarm: red, incandescent lightAudio Alarm: buzzer with user acknowledgeWarranty: two year, parts and labour (subject to standard amc

terms and conditions)the AMc RAM3 provides an all-in-one solution to your remote alarm requirements.Features: • Flashingredvisualalarm • Alarmbuzzerwithuseracknowledge

(allows user to silence buzzer while unit is still in alarm). visual alarm can not be acknowledged.

• On-boardrelayforactivationofauxiliaryalarms • Nema4Xpackaging

Supply Voltage Range: 12-24 vdc nominalOperating Temperature Range: -20°c to +50°cInput: 4-20 ma dcOutput: 4-20 ma dc into 250 ohmsRelays: fail, low, high

1a @30 vdc resistive 300 ma @ low voltage

Display: 0.37” led, 3½ digital ledAlarm Indication: leds for fail, low, high alarm statescalibration: factory calibrated trip pointsModule Warranty: two yearsa compact module housed in a class 1, division 1, group b, c, d three hub explosion proof enclosure or within nema 1, 12 or 4X enclosures. outputs of 4-20 ma from a variety of gas sensor/transmitters are accepted to offer local or remote concentration readouts, alarm indication and contacts. the im331 features a 3½ digit led display for indicating gas concentrations and has relay outputs for fail, low and high alarms. there is also a 4-20 ma repeater output which matches the input signal. as a din rail mounted unit, this module can be combined with a wide assortment of monitoring instruments for local indication and alarm functions.

AcceSSORIeSAMc RAM3 REMOTE AlARM/AcKNOWlEDGE MODUlE

AMc IM331 (INTERFAcE MODUlE) DISplAy AND RElAy MODUlE

Page 14: - ECCO Supply. Controls/Armstrong Monitoring.pdf ·  ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and ... amc c series calibration kit ...

– E.&O.E. – May not be in stock at all branches, if so please allow 10 days for delivery. – – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra –

ECCO Supply7-14 www.eccosupply.ca

ARMSTRONG MONITORING

www.armstrongmonitoring.com

Effective: March 2010

calibration kits are essential in ensuring that your gas sensor accuracy is at its peak. sensors should be calibrated on a regular basis to compensate for signal loss or drift and to guarantee optimal performance.amc calibration kits are durable, economical and easily operated. cal kits include a carry case, regulator, flow adapter, calibration hose and a calibration jack. our gas cylinders are available in numerous standard gases including co, cH4, nH3, co2 and cl2.

1) cARRy cASEour calibration kit carrying cases are constructed of moulded high impact resistant plastic ensuring its vigorous durability. this will protect your amc calibration equipment from the harshest, most volatile environments ensuring that your calibration kit is damage-free and fully operational when needed.

2) REGUlATORthe regulator control valve is the intermediary connecting the hose to the gas cylinder. the regulator’s function is to control the amount of gas fed from the cylinder, through the calibration unit and ultimately onto the sensor. standard regulators flow at one litre per minute.

3) FlOW ADApTERthe flow adapter is designed to fit comfortably onto the sensor. constructed of flexible yet durable material, the flow adapter ensures that the sensor receives proper exposure to the calibration gas. flow adapters are specific to sensor type.

4) cAlIbRATION HOSEmade of vinyl or teflon, the calibration hose linking the regulator to the flow adapter must be made of materials that will not absorb gas, altering the concentration.

5) cAlIbRATION JAcKthis device interconnects simple 4-20ma transmitters to standard multimeters.

GAS cylINDER (SOlD SEpARATEly)gas cylinders are available from amc in a variety of sizes and gas types. many gas mixtures are available only in specific gas cylinder sizes. following is a listing of common calibration/replacement gas cylinders:

large cylinders (103 or 58 liters) AMc cO100-103 100 ppm co in air or nitrogen (103 liters) AMc NO210-58 10 ppm no2 in air or nitrogen (58 liters) AMc cl210-58 10 ppm cl2 in air or nitrogen (58 liters) AMc NH3100-58 100 ppm nH3 in air or nitrogen (58 liters) AMc cH450-103 50% lel methane (103 liters) AMc H2S25-58 25 ppm H2s in air or nitrogen (58 liters) AMc SO210-58 10 ppm so2 (58 liters) AMc 4cM-58 four component mix (co, o2, cH4, n2) (58 liters)

Small cylinders (15 or 17 liters) AMc cO100-17 100 ppm co in air AMc cH450-17 50% lel methane AMc 4cM-17 four component mix

Note: For other gas mixtures or permeation systems, please contact your ECCO Supply sales representative.

AcceSSORIeS (cont’d)AMc c SERIES cAlIbRATION KIT

calibration kit carry case

regulator

calibration Hose

flow adaptor

calibration Jack

17l gas cylinder

58-103l gas cylinder