+Discussion on outliers

Information from Antonella Succurro – list of outliers Oleg – list of pathologies seen in monoCis phase scans

Page 2: + Discussion on outliers Information from Antonella Succurro – list of outliers Oleg – list of pathologies seen in monoCis phase scans.

+LBA - digitizers LBA05 1 digitizer chan18-23 offset -25.5ns

LBA08 1 digitizer chan 32-35 offset -6.5ns

LBA10 1 digitizer chan 12-17 offset 9ns Large Tfit RMS 2.3ns Beam2

LBA25 1 digi chan 24-29 offset -25ns

LBA31 1 digi chan 42-47 offset -24.7ns

LBA37 1 digi chan 36-41 offset 21.9ns Tagged by Oleg MonoCis phase scan does not affect Tfit possible bad TTCRx address

LBA40 1 digi chan 18-23 offset 4ns Large Tfit RMS 1.2ns Beam 2

LBA56 chan 24-29 offset 35.4ns

LBA56 chan 36-41 offset -35.5ns

LBA60 chan 12-17 offset -25.5ns

Page 3: + Discussion on outliers Information from Antonella Succurro – list of outliers Oleg – list of pathologies seen in monoCis phase scans.

+LBC – digitizers / drawers LBC03 chan 32-35 offset 4ns Tagged by Oleg

wrong time at few Dskews...

LBC10 chan 18-23 offset -5.9ns Tagged by Oleg stuck bit in dskew setting?

LBC11 chan 18-23 offset 3.3ns

LBC29 chan 0-11 offset -2.3ns

LBC29 chan 12-17 offset -10.9ns

LBC29 chan 18-47 offset -2.3ns

LBC30 chan 18-23 offset 6.3ns

LBC31 chan 12-17 offset -7.3ns

LBC33 all digis offset -4.4ns

LBC34 all digis offset -2.7ns

Page 4: + Discussion on outliers Information from Antonella Succurro – list of outliers Oleg – list of pathologies seen in monoCis phase scans.

+EBC - digitizers EBC16 chan 30-35 12ns Large Tfit RMS

3.7ns Beam 2

EBC21 chan 20-23 -24.8ns

EBC33 chan 30-35 12ns Large Tfit RMS 3.5ns Beam 2

EBC56 chan 30-35 13ns Large Tfit RMS 3.9ns Beam 2

Page 5: + Discussion on outliers Information from Antonella Succurro – list of outliers Oleg – list of pathologies seen in monoCis phase scans.

+Special pathologies

LBA29 chan 0-5 all the digi needs to be shifted amount not completely clear

due to large spread among Tfits. Possible take offset from channels 3,4,5 for beam which have Tfit~19.5 and small RMS,

but need a look, laser, monoCis with phase scan

LBA30 chan 12-14 (half digi!) could it be that it is full digi but the other half did not pass

some selections used to look at outliers? Under discussion with Antonella

Page 6: + Discussion on outliers Information from Antonella Succurro – list of outliers Oleg – list of pathologies seen in monoCis phase scans.

+Single Channels with non zero Tfits LBA

LBA21 chan 19 Tfit RMS =2.1ns

LBA30 chan 5

LBA45 chan 29

LBA48 chan 23

LBA49 chan 23

LBA49 chan 32

Channel with less than 10 events for <Tfit> determination

Page 7: + Discussion on outliers Information from Antonella Succurro – list of outliers Oleg – list of pathologies seen in monoCis phase scans.

+Single Channels with non zero TfitsLBC LBC49 chan 5

Page 8: + Discussion on outliers Information from Antonella Succurro – list of outliers Oleg – list of pathologies seen in monoCis phase scans.

+Single Channels with non zero TfitsEBA EBA3 chan 1

EBA4 chan 1

EBA12 chan 1

EBA 13 chan 1

EBA 47 chan 6

EBA60 chan 1

EBA61 chan 1

Page 9: + Discussion on outliers Information from Antonella Succurro – list of outliers Oleg – list of pathologies seen in monoCis phase scans.

+Single Channels with non zero TfitsEBC EBC12 chan 1

EBC13 chan 1

EBC18 chan 4 Large RMS 2.3ns

EBC36 chan 1

EBC37 chan 1

EBC46 chan 1

EBC55 chan6

EBC64 chan31 Large RMS 7ns

Page 10: + Discussion on outliers Information from Antonella Succurro – list of outliers Oleg – list of pathologies seen in monoCis phase scans.

+Conclusion All offsets that are per digitizers or per module or per

channel that are not in Oleg's list of problematic digitizers have small RMS on Tfits. => UPDATE OFFLINE RESIDUALS

Others study further with Laser runs in the gap Physics runs monoCis with phase scans

Missing the outliers in standard format thus writing script for conversion the updated residuals should be updated tonight